{"id":"https://openalex.org/W2158658548","doi":"https://doi.org/10.1109/tim.2008.2011088","title":"The Calibration of IEC Standard Flickermeters Using Complex Modulated Signals","display_name":"The Calibration of IEC Standard Flickermeters Using Complex Modulated Signals","publication_year":2009,"publication_date":"2009-01-20","ids":{"openalex":"https://openalex.org/W2158658548","doi":"https://doi.org/10.1109/tim.2008.2011088","mag":"2158658548"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2008.2011088","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2008.2011088","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5110689984","display_name":"Paul Clarkson","orcid":null},"institutions":[{"id":"https://openalex.org/I134421475","display_name":"National Physical Laboratory","ror":"https://ror.org/015w2mp89","country_code":"GB","type":"facility","lineage":["https://openalex.org/I134421475"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"P. Clarkson","raw_affiliation_strings":["National Physical Laboratory, Teddington, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Physical Laboratory, Teddington, UK","institution_ids":["https://openalex.org/I134421475"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5079541661","display_name":"Paul Wright","orcid":"https://orcid.org/0000-0003-3831-3216"},"institutions":[{"id":"https://openalex.org/I134421475","display_name":"National Physical Laboratory","ror":"https://ror.org/015w2mp89","country_code":"GB","type":"facility","lineage":["https://openalex.org/I134421475"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"P.S. Wright","raw_affiliation_strings":["National Physical Laboratory, Teddington, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Physical Laboratory, Teddington, UK","institution_ids":["https://openalex.org/I134421475"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I134421475"],"apc_list":null,"apc_paid":null,"fwci":1.0892,"has_fulltext":false,"cited_by_count":8,"citation_normalized_percentile":{"value":0.81377864,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":97},"biblio":{"volume":"58","issue":"4","first_page":"1017","last_page":"1022"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12564","display_name":"Sensor Technology and Measurement Systems","score":0.9959999918937683,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12564","display_name":"Sensor Technology and Measurement Systems","score":0.9959999918937683,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.9944000244140625,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.986299991607666,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/waveform","display_name":"Waveform","score":0.8626600503921509},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.7846711874008179},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.6405313014984131},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.5238352417945862},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3280831575393677},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.28790974617004395},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.22655275464057922},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.11392298340797424}],"concepts":[{"id":"https://openalex.org/C197424946","wikidata":"https://www.wikidata.org/wiki/Q1165717","display_name":"Waveform","level":3,"score":0.8626600503921509},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.7846711874008179},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.6405313014984131},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5238352417945862},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3280831575393677},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.28790974617004395},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.22655275464057922},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.11392298340797424},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tim.2008.2011088","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2008.2011088","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":9,"referenced_works":["https://openalex.org/W2021545947","https://openalex.org/W2065420076","https://openalex.org/W2097660380","https://openalex.org/W2112248071","https://openalex.org/W2163736485","https://openalex.org/W2985846083","https://openalex.org/W3207220348","https://openalex.org/W3212646446","https://openalex.org/W6803650226"],"related_works":["https://openalex.org/W2899084033","https://openalex.org/W2748952813","https://openalex.org/W1974895211","https://openalex.org/W2176409448","https://openalex.org/W2129841057","https://openalex.org/W3040712279","https://openalex.org/W2364769705","https://openalex.org/W4367555392","https://openalex.org/W2374664672","https://openalex.org/W2056136368"],"abstract_inverted_index":{"Flickermeter":[0],"calibrations":[1],"currently":[2],"rely":[3],"on":[4],"the":[5,25,31,38,59,62],"predicted":[6],"response":[7,39],"of":[8,19,24,40,50,58,61],"a":[9,66],"standard":[10,27],"flickermeter":[11],"to":[12,36,43],"basic":[13],"waveforms.":[14],"A":[15,56],"description":[16,57],"is":[17,74],"given":[18],"an":[20],"interpretation":[21],"and":[22],"implementation":[23],"IEC":[26],"flickermeter,":[28],"developed":[29],"at":[30],"national":[32],"physical":[33],"laboratory":[34],"(NPL),":[35],"assess":[37],"commercial":[41],"flickermeters":[42,70],"more":[44],"complex":[45],"waveforms,":[46],"which":[47],"are":[48],"representative":[49],"signals":[51],"that":[52],"occur":[53],"in":[54],"practice.":[55],"incorporation":[60],"resulting":[63],"model":[64],"into":[65],"calibration":[67],"system":[68],"for":[69],"under":[71],"complex-waveform":[72],"conditions":[73],"given.":[75]},"counts_by_year":[{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":1},{"year":2013,"cited_by_count":3},{"year":2012,"cited_by_count":1}],"updated_date":"2026-06-26T08:34:08.712188","created_date":"2025-10-10T00:00:00"}
