{"id":"https://openalex.org/W7123339357","doi":"https://doi.org/10.1109/tii.2025.3642608","title":"Mean-Filtering-Based Memory Event-Triggered Overload-Avoiding Secondary Voltage Consensus Control for Microgrids","display_name":"Mean-Filtering-Based Memory Event-Triggered Overload-Avoiding Secondary Voltage Consensus Control for Microgrids","publication_year":2026,"publication_date":"2026-01-12","ids":{"openalex":"https://openalex.org/W7123339357","doi":"https://doi.org/10.1109/tii.2025.3642608"},"language":null,"primary_location":{"id":"doi:10.1109/tii.2025.3642608","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tii.2025.3642608","pdf_url":null,"source":{"id":"https://openalex.org/S184777250","display_name":"IEEE Transactions on Industrial Informatics","issn_l":"1551-3203","issn":["1551-3203","1941-0050"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Informatics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5002903770","display_name":"Jiayue Sun","orcid":"https://orcid.org/0000-0002-7774-2606"},"institutions":[{"id":"https://openalex.org/I9224756","display_name":"Northeastern University","ror":"https://ror.org/03awzbc87","country_code":"CN","type":"education","lineage":["https://openalex.org/I9224756"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jiayue Sun","raw_affiliation_strings":["State Key Laboratory of Synthetical Automation for Process Industries, Northeastern University, Shenyang, China"],"raw_orcid":"https://orcid.org/0000-0002-7774-2606","affiliations":[{"raw_affiliation_string":"State Key Laboratory of Synthetical Automation for Process Industries, Northeastern University, Shenyang, China","institution_ids":["https://openalex.org/I9224756"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101734186","display_name":"Siyu Guo","orcid":"https://orcid.org/0000-0002-0414-818X"},"institutions":[{"id":"https://openalex.org/I9224756","display_name":"Northeastern University","ror":"https://ror.org/03awzbc87","country_code":"CN","type":"education","lineage":["https://openalex.org/I9224756"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Siyu Guo","raw_affiliation_strings":["College of Information Science and Engineering, Northeastern University, Shenyang, Liaoning, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"College of Information Science and Engineering, Northeastern University, Shenyang, Liaoning, China","institution_ids":["https://openalex.org/I9224756"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5026139117","display_name":"Zeyi Liu","orcid":"https://orcid.org/0000-0002-9519-4084"},"institutions":[{"id":"https://openalex.org/I9224756","display_name":"Northeastern University","ror":"https://ror.org/03awzbc87","country_code":"CN","type":"education","lineage":["https://openalex.org/I9224756"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zeyi Liu","raw_affiliation_strings":["College of Information Science and Engineering, Northeastern University, Shenyang, Liaoning, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"College of Information Science and Engineering, Northeastern University, Shenyang, Liaoning, China","institution_ids":["https://openalex.org/I9224756"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5121348402","display_name":"Zhiming Xu","orcid":null},"institutions":[{"id":"https://openalex.org/I9224756","display_name":"Northeastern University","ror":"https://ror.org/03awzbc87","country_code":"CN","type":"education","lineage":["https://openalex.org/I9224756"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhiming Xu","raw_affiliation_strings":["College of Information Science and Engineering, Northeastern University, Shenyang, Liaoning, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"College of Information Science and Engineering, Northeastern University, Shenyang, Liaoning, China","institution_ids":["https://openalex.org/I9224756"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.04617898,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"22","issue":"4","first_page":"3507","last_page":"3516"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9668999910354614,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9668999910354614,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.003700000001117587,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.0034000000450760126,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/robustness","display_name":"Robustness (evolution)","score":0.7767999768257141},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.6895999908447266},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.6032000184059143},{"id":"https://openalex.org/keywords/voltage-regulation","display_name":"Voltage regulation","score":0.5006999969482422},{"id":"https://openalex.org/keywords/synchronization","display_name":"Synchronization (alternating current)","score":0.49619999527931213},{"id":"https://openalex.org/keywords/process","display_name":"Process (computing)","score":0.4771000146865845},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.37619999051094055},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.3522999882698059},{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.3336000144481659}],"concepts":[{"id":"https://openalex.org/C63479239","wikidata":"https://www.wikidata.org/wiki/Q7353546","display_name":"Robustness (evolution)","level":3,"score":0.7767999768257141},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.6895999908447266},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6032000184059143},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5565999746322632},{"id":"https://openalex.org/C196226539","wikidata":"https://www.wikidata.org/wiki/Q7940752","display_name":"Voltage regulation","level":3,"score":0.5006999969482422},{"id":"https://openalex.org/C2778562939","wikidata":"https://www.wikidata.org/wiki/Q1298791","display_name":"Synchronization (alternating current)","level":3,"score":0.49619999527931213},{"id":"https://openalex.org/C98045186","wikidata":"https://www.wikidata.org/wiki/Q205663","display_name":"Process (computing)","level":2,"score":0.4771000146865845},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.41609999537467957},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.38769999146461487},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.37619999051094055},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.3522999882698059},{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.3336000144481659},{"id":"https://openalex.org/C2779585090","wikidata":"https://www.wikidata.org/wiki/Q3457762","display_name":"Resilience (materials science)","level":2,"score":0.32910001277923584},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3255999982357025},{"id":"https://openalex.org/C31531917","wikidata":"https://www.wikidata.org/wiki/Q915157","display_name":"Robust control","level":3,"score":0.32199999690055847},{"id":"https://openalex.org/C46529443","wikidata":"https://www.wikidata.org/wiki/Q7940750","display_name":"Voltage optimisation","level":4,"score":0.30790001153945923},{"id":"https://openalex.org/C204241405","wikidata":"https://www.wikidata.org/wiki/Q461499","display_name":"Transformation (genetics)","level":3,"score":0.3059999942779541},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.2989000082015991},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.29789999127388},{"id":"https://openalex.org/C2986283658","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed power generation","level":4,"score":0.29339998960494995},{"id":"https://openalex.org/C155386361","wikidata":"https://www.wikidata.org/wiki/Q1649571","display_name":"Process control","level":3,"score":0.289000004529953},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.28119999170303345},{"id":"https://openalex.org/C110706871","wikidata":"https://www.wikidata.org/wiki/Q851210","display_name":"Voltage regulator","level":3,"score":0.2791999876499176},{"id":"https://openalex.org/C144655898","wikidata":"https://www.wikidata.org/wiki/Q1161128","display_name":"Voltage source","level":3,"score":0.27649998664855957},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.26820001006126404},{"id":"https://openalex.org/C44351266","wikidata":"https://www.wikidata.org/wiki/Q1465532","display_name":"Voltage reference","level":3,"score":0.2671000063419342},{"id":"https://openalex.org/C2778915421","wikidata":"https://www.wikidata.org/wiki/Q3643177","display_name":"Performance improvement","level":2,"score":0.2599000036716461},{"id":"https://openalex.org/C140501009","wikidata":"https://www.wikidata.org/wiki/Q6692746","display_name":"Low-dropout regulator","level":5,"score":0.2581999897956848},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.2547999918460846}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tii.2025.3642608","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tii.2025.3642608","pdf_url":null,"source":{"id":"https://openalex.org/S184777250","display_name":"IEEE Transactions on Industrial Informatics","issn_l":"1551-3203","issn":["1551-3203","1941-0050"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Informatics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.6001685857772827,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[{"id":"https://openalex.org/G3033528074","display_name":null,"funder_award_id":"62473090","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G8158497768","display_name":null,"funder_award_id":"XLYC2403063","funder_id":"https://openalex.org/F4320329895","funder_display_name":"Liaoning Revitalization Talents Program"}],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"},{"id":"https://openalex.org/F4320329895","display_name":"Liaoning Revitalization Talents Program","ror":null}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"This":[0,44],"article":[1],"presents":[2],"a":[3,67],"novel":[4],"secondary":[5,80],"voltage":[6,33,63,81,91],"consensus":[7],"control":[8,82],"framework":[9,18],"for":[10],"microgrids":[11,97],"equipped":[12],"with":[13,117],"multiple":[14],"distributed":[15],"generators.":[16],"The":[17],"ensures":[19],"that":[20,93,106],"these":[21],"units":[22],"consistently":[23],"achieve":[24],"specified":[25],"performance":[26,39,55,120,126],"levels":[27],"while":[28,87],"demonstrating":[29],"resilience":[30],"to":[31,74,123],"abnormal":[32],"signals.":[34],"First,":[35],"an":[36],"innovative":[37],"overload-avoiding":[38],"transformation":[40],"method":[41],"is":[42,72,104],"proposed.":[43],"approach":[45],"confines":[46],"the":[47,76,79,107,113,118,124,132,135],"synchronization":[48],"errors":[49],"of":[50,78,134],"all":[51],"generators":[52],"within":[53],"prescribed":[54,125],"boundaries":[56],"without":[57],"imposing":[58],"restrictions":[59],"on":[60],"their":[61],"initial":[62],"conditions.":[64],"In":[65],"addition,":[66],"mean-filtering-based":[68],"memory":[69],"event-triggered":[70],"mechanism":[71],"developed":[73],"bolster":[75],"robustness":[77],"process":[83],"against":[84],"non-real-time":[85],"signals,":[86],"also":[88],"mitigating":[89],"undesirable":[90],"fluctuations":[92],"may":[94],"occur":[95],"in":[96],"by":[98],"utilizing":[99],"stored":[100],"stable":[101],"data.":[102],"It":[103],"shown":[105],"generators'":[108],"output":[109],"voltages":[110],"accurately":[111],"track":[112],"desired":[114],"reference":[115],"voltage,":[116],"tracking":[119],"strictly":[121],"adhering":[122],"criteria.":[127],"Simulation":[128],"results":[129],"further":[130],"validate":[131],"efficacy":[133],"proposed":[136],"method.":[137]},"counts_by_year":[],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2026-01-14T00:00:00"}
