{"id":"https://openalex.org/W4401835712","doi":"https://doi.org/10.1109/tii.2024.3431632","title":"Diagnosis of Inter-Turn Short-Circuit Incipient Fault in Permanent Magnet Synchronous Motors Using Input Current on the Power Side","display_name":"Diagnosis of Inter-Turn Short-Circuit Incipient Fault in Permanent Magnet Synchronous Motors Using Input Current on the Power Side","publication_year":2024,"publication_date":"2024-08-23","ids":{"openalex":"https://openalex.org/W4401835712","doi":"https://doi.org/10.1109/tii.2024.3431632"},"language":"en","primary_location":{"id":"doi:10.1109/tii.2024.3431632","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tii.2024.3431632","pdf_url":null,"source":{"id":"https://openalex.org/S184777250","display_name":"IEEE Transactions on Industrial Informatics","issn_l":"1551-3203","issn":["1551-3203","1941-0050"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Informatics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5113346679","display_name":"Hongjie Li","orcid":null},"institutions":[{"id":"https://openalex.org/I162868743","display_name":"Tianjin University","ror":"https://ror.org/012tb2g32","country_code":"CN","type":"education","lineage":["https://openalex.org/I162868743"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Hongjie Li","raw_affiliation_strings":["School of Electrical and Information Engineering, Tianjin University, Tianjin, China"],"raw_orcid":"https://orcid.org/0009-0002-8691-5924","affiliations":[{"raw_affiliation_string":"School of Electrical and Information Engineering, Tianjin University, Tianjin, China","institution_ids":["https://openalex.org/I162868743"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5049871554","display_name":"Tingna Shi","orcid":"https://orcid.org/0000-0002-5824-9453"},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Tingna Shi","raw_affiliation_strings":["College of Electrical Engineering, Zhejiang University, Hangzhou, China"],"raw_orcid":"https://orcid.org/0000-0002-5824-9453","affiliations":[{"raw_affiliation_string":"College of Electrical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5113346679"],"corresponding_institution_ids":["https://openalex.org/I162868743"],"apc_list":null,"apc_paid":null,"fwci":2.8397,"has_fulltext":false,"cited_by_count":9,"citation_normalized_percentile":{"value":0.90969394,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":96,"max":99},"biblio":{"volume":"20","issue":"12","first_page":"13741","last_page":"13752"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9904000163078308,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9904000163078308,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11222","display_name":"Magnetic Properties and Applications","score":0.9879999756813049,"subfield":{"id":"https://openalex.org/subfields/2504","display_name":"Electronic, Optical and Magnetic Materials"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.9876000285148621,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/synchronous-motor","display_name":"Synchronous motor","score":0.6184148192405701},{"id":"https://openalex.org/keywords/short-circuit","display_name":"Short circuit","score":0.6124215126037598},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.5722277164459229},{"id":"https://openalex.org/keywords/permanent-magnet-synchronous-generator","display_name":"Permanent magnet synchronous generator","score":0.5623117089271545},{"id":"https://openalex.org/keywords/magnet","display_name":"Magnet","score":0.5591381788253784},{"id":"https://openalex.org/keywords/turn","display_name":"Turn (biochemistry)","score":0.5518293976783752},{"id":"https://openalex.org/keywords/current","display_name":"Current (fluid)","score":0.5043538808822632},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.5035867094993591},{"id":"https://openalex.org/keywords/permanent-magnet-synchronous-motor","display_name":"Permanent magnet synchronous motor","score":0.4989583492279053},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.4860720932483673},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.3670821785926819},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.34967154264450073},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.34698283672332764},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3029683828353882},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.2130020558834076},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.17872005701065063},{"id":"https://openalex.org/keywords/nuclear-magnetic-resonance","display_name":"Nuclear magnetic resonance","score":0.09434190392494202},{"id":"https://openalex.org/keywords/geology","display_name":"Geology","score":0.06636089086532593}],"concepts":[{"id":"https://openalex.org/C71376005","wikidata":"https://www.wikidata.org/wiki/Q845675","display_name":"Synchronous motor","level":2,"score":0.6184148192405701},{"id":"https://openalex.org/C68583231","wikidata":"https://www.wikidata.org/wiki/Q206907","display_name":"Short circuit","level":3,"score":0.6124215126037598},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5722277164459229},{"id":"https://openalex.org/C201320609","wikidata":"https://www.wikidata.org/wiki/Q3274420","display_name":"Permanent magnet synchronous generator","level":3,"score":0.5623117089271545},{"id":"https://openalex.org/C16389437","wikidata":"https://www.wikidata.org/wiki/Q11421","display_name":"Magnet","level":2,"score":0.5591381788253784},{"id":"https://openalex.org/C85641259","wikidata":"https://www.wikidata.org/wiki/Q290042","display_name":"Turn (biochemistry)","level":2,"score":0.5518293976783752},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.5043538808822632},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.5035867094993591},{"id":"https://openalex.org/C2986944758","wikidata":"https://www.wikidata.org/wiki/Q845675","display_name":"Permanent magnet synchronous motor","level":3,"score":0.4989583492279053},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4860720932483673},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.3670821785926819},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.34967154264450073},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.34698283672332764},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3029683828353882},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.2130020558834076},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.17872005701065063},{"id":"https://openalex.org/C46141821","wikidata":"https://www.wikidata.org/wiki/Q209402","display_name":"Nuclear magnetic resonance","level":1,"score":0.09434190392494202},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.06636089086532593},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tii.2024.3431632","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tii.2024.3431632","pdf_url":null,"source":{"id":"https://openalex.org/S184777250","display_name":"IEEE Transactions on Industrial Informatics","issn_l":"1551-3203","issn":["1551-3203","1941-0050"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Informatics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.8600000143051147,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":26,"referenced_works":["https://openalex.org/W2005580246","https://openalex.org/W2111862584","https://openalex.org/W2133238565","https://openalex.org/W2158499370","https://openalex.org/W2765793020","https://openalex.org/W2783819238","https://openalex.org/W2802128760","https://openalex.org/W2904391578","https://openalex.org/W2997802292","https://openalex.org/W3011538722","https://openalex.org/W3023396847","https://openalex.org/W3034195175","https://openalex.org/W3044869293","https://openalex.org/W3046768359","https://openalex.org/W3106483999","https://openalex.org/W3138962322","https://openalex.org/W3141456309","https://openalex.org/W3157339950","https://openalex.org/W3200371711","https://openalex.org/W4206535439","https://openalex.org/W4214684988","https://openalex.org/W4225876525","https://openalex.org/W4289752563","https://openalex.org/W4319302873","https://openalex.org/W4365128558","https://openalex.org/W4375929112"],"related_works":["https://openalex.org/W3010211530","https://openalex.org/W4252156693","https://openalex.org/W2355594986","https://openalex.org/W2144803608","https://openalex.org/W2087042126","https://openalex.org/W4242196303","https://openalex.org/W2990813845","https://openalex.org/W2615749722","https://openalex.org/W4400772239","https://openalex.org/W4387976010"],"abstract_inverted_index":{"Past":[0],"research":[1],"has":[2,120],"shown":[3],"that":[4,129,168],"completing":[5],"diagnosis":[6,55,179],"in":[7,17,30,80],"the":[8,26,31,72,85,92,130,138,143,149,156,161,169,172],"incipient":[9,93,152],"fault":[10,54,77,94,111,131],"stage":[11],"of":[12,36,71,91,160,171],"low-turn,":[13],"high-resistance":[14],"short":[15],"circuits":[16],"permanent":[18,117],"magnet":[19,118],"motors":[20],"is":[21,176],"still":[22],"a":[23,99,114],"challenge.":[24],"Meanwhile,":[25],"motor":[27,40,119],"signals":[28],"employed":[29],"established":[32],"technology":[33],"route":[34],"are":[35],"poor":[37],"practicality":[38],"for":[39,108,123,178],"systems":[41],"with":[42,102],"increasing":[43],"integration.":[44],"For":[45],"these":[46],"reasons,":[47],"this":[48,66,96,164],"article":[49,67,97,165],"proposes":[50],"an":[51,103],"interturn":[52,109,150],"short-circuit":[53,110,151],"method":[56,145],"utilizing":[57],"power-side":[58,73,139],"input":[59,74,140,173],"current":[60,75,174],"and":[61,87,142,180],"channel":[62,105],"attention":[63,106],"mechanism.":[64],"First,":[65],"derives":[68],"harmonic":[69],"features":[70,90],"under":[76],"conditions.":[78],"Then,":[79],"order":[81],"to":[82,137],"sufficiently":[83],"exploit":[84],"spatial":[86],"temporal":[88],"scale":[89],"data,":[95],"develops":[98],"residual":[100],"model":[101],"improved":[104],"mechanism":[107],"diagnosis.":[112],"Finally,":[113],"2.3":[115],"kW":[116],"been":[121],"used":[122],"experimental":[124],"validation.":[125],"The":[126],"results":[127],"show":[128],"information":[132],"can":[133,146],"be":[134],"effectively":[135],"transmitted":[136],"current,":[141],"proposed":[144,162],"accurately":[147],"diagnose":[148],"fault.":[153],"Furthermore,":[154],"through":[155],"feature":[157],"explainability":[158],"analysis":[159],"model,":[163],"also":[166],"finds":[167],"region":[170],"fluctuation":[175],"favorable":[177],"deserves":[181],"attention.":[182]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":8}],"updated_date":"2025-12-21T01:58:51.020947","created_date":"2025-10-10T00:00:00"}