{"id":"https://openalex.org/W3028404235","doi":"https://doi.org/10.1109/tii.2020.2995997","title":"An Improved Sparse-Measurement Based Fault Location Technology for Distribution Networks","display_name":"An Improved Sparse-Measurement Based Fault Location Technology for Distribution Networks","publication_year":2020,"publication_date":"2020-01-01","ids":{"openalex":"https://openalex.org/W3028404235","doi":"https://doi.org/10.1109/tii.2020.2995997","mag":"3028404235"},"language":"en","primary_location":{"id":"doi:10.1109/tii.2020.2995997","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tii.2020.2995997","pdf_url":null,"source":{"id":"https://openalex.org/S184777250","display_name":"IEEE Transactions on Industrial Informatics","issn_l":"1551-3203","issn":["1551-3203","1941-0050"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Informatics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5014163978","display_name":"Ke Jia","orcid":"https://orcid.org/0000-0001-9140-1050"},"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Ke Jia","raw_affiliation_strings":["State Key Laboratory of Alternative Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Alternative Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China","institution_ids":["https://openalex.org/I153473198"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5035243852","display_name":"Bin Yang","orcid":"https://orcid.org/0000-0001-5963-2844"},"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Bin Yang","raw_affiliation_strings":["State Key Laboratory of Alternative Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Alternative Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China","institution_ids":["https://openalex.org/I153473198"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5077234408","display_name":"Tianshu Bi","orcid":"https://orcid.org/0000-0002-3555-9045"},"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Tianshu Bi","raw_affiliation_strings":["State Key Laboratory of Alternative Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Alternative Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China","institution_ids":["https://openalex.org/I153473198"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5037151071","display_name":"Liming Zheng","orcid":"https://orcid.org/0000-0003-3179-2162"},"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Liming Zheng","raw_affiliation_strings":["State Key Laboratory of Alternative Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Alternative Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China","institution_ids":["https://openalex.org/I153473198"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I153473198"],"apc_list":null,"apc_paid":null,"fwci":3.9358,"has_fulltext":false,"cited_by_count":43,"citation_normalized_percentile":{"value":0.93933845,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":94,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"1"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9977999925613403,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9977999925613403,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10500","display_name":"Sparse and Compressive Sensing Techniques","score":0.9962000250816345,"subfield":{"id":"https://openalex.org/subfields/2206","display_name":"Computational Mechanics"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9927999973297119,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.68180251121521},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5883690714836121},{"id":"https://openalex.org/keywords/metering-mode","display_name":"Metering mode","score":0.5392917394638062},{"id":"https://openalex.org/keywords/noise","display_name":"Noise (video)","score":0.5048821568489075},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.48417192697525024},{"id":"https://openalex.org/keywords/compressed-sensing","display_name":"Compressed sensing","score":0.4524660110473633},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.4460406005382538},{"id":"https://openalex.org/keywords/fault-coverage","display_name":"Fault coverage","score":0.44582709670066833},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.4210677146911621},{"id":"https://openalex.org/keywords/fault-indicator","display_name":"Fault indicator","score":0.4123353362083435},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.4113401770591736},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3511224389076233},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.2790130078792572},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.12048935890197754},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.09358042478561401}],"concepts":[{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.68180251121521},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5883690714836121},{"id":"https://openalex.org/C30905978","wikidata":"https://www.wikidata.org/wiki/Q815598","display_name":"Metering mode","level":2,"score":0.5392917394638062},{"id":"https://openalex.org/C99498987","wikidata":"https://www.wikidata.org/wiki/Q2210247","display_name":"Noise (video)","level":3,"score":0.5048821568489075},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.48417192697525024},{"id":"https://openalex.org/C124851039","wikidata":"https://www.wikidata.org/wiki/Q2665459","display_name":"Compressed sensing","level":2,"score":0.4524660110473633},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4460406005382538},{"id":"https://openalex.org/C126953365","wikidata":"https://www.wikidata.org/wiki/Q5438152","display_name":"Fault coverage","level":3,"score":0.44582709670066833},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.4210677146911621},{"id":"https://openalex.org/C21267803","wikidata":"https://www.wikidata.org/wiki/Q5438159","display_name":"Fault indicator","level":4,"score":0.4123353362083435},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.4113401770591736},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3511224389076233},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.2790130078792572},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.12048935890197754},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.09358042478561401},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C115961682","wikidata":"https://www.wikidata.org/wiki/Q860623","display_name":"Image (mathematics)","level":2,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C134146338","wikidata":"https://www.wikidata.org/wiki/Q1815901","display_name":"Electronic circuit","level":2,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tii.2020.2995997","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tii.2020.2995997","pdf_url":null,"source":{"id":"https://openalex.org/S184777250","display_name":"IEEE Transactions on Industrial Informatics","issn_l":"1551-3203","issn":["1551-3203","1941-0050"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Informatics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":31,"referenced_works":["https://openalex.org/W89716402","https://openalex.org/W1977336398","https://openalex.org/W1977719311","https://openalex.org/W1988976245","https://openalex.org/W2014243485","https://openalex.org/W2015418199","https://openalex.org/W2065513175","https://openalex.org/W2078204800","https://openalex.org/W2105049517","https://openalex.org/W2115606304","https://openalex.org/W2127271355","https://openalex.org/W2149799845","https://openalex.org/W2156315540","https://openalex.org/W2160547390","https://openalex.org/W2296616510","https://openalex.org/W2297838063","https://openalex.org/W2324988224","https://openalex.org/W2342819817","https://openalex.org/W2432545511","https://openalex.org/W2514174482","https://openalex.org/W2612688703","https://openalex.org/W2739002725","https://openalex.org/W2754811822","https://openalex.org/W2779977204","https://openalex.org/W2922319584","https://openalex.org/W2945308371","https://openalex.org/W2998866143","https://openalex.org/W4229881843","https://openalex.org/W4250955649","https://openalex.org/W4285719527","https://openalex.org/W6676940277"],"related_works":["https://openalex.org/W3171530565","https://openalex.org/W3186790058","https://openalex.org/W3148663848","https://openalex.org/W2024194466","https://openalex.org/W2163103195","https://openalex.org/W2051500795","https://openalex.org/W4210447066","https://openalex.org/W2896156965","https://openalex.org/W1974225921","https://openalex.org/W4389064908"],"abstract_inverted_index":{"In":[0],"this":[1],"article,":[2],"a":[3,30,41,98,120],"sparse-measurement-based":[4],"fault":[5,10,38,76],"location":[6],"method":[7,71,94,117],"for":[8,61,74,123],"all":[9],"types":[11],"in":[12,106],"the":[13,17,37,46,49,62,66,70,75,93,107,115],"distribution":[14,102],"networks":[15],"with/without":[16],"distributed":[18],"generators":[19],"access":[20],"is":[21,95,118],"proposed.":[22],"The":[23,90],"pre-":[24],"and":[25,83],"during-fault":[26],"voltage":[27],"samplings":[28],"at":[29],"few":[31],"buses":[32],"are":[33,53,57],"needful":[34],"to":[35],"estimate":[36],"position":[39],"via":[40],"compressed":[42],"sensing":[43],"algorithm.":[44],"Besides,":[45],"principles":[47],"of":[48,58,65,78,86,92,119],"sparse":[50],"meter":[51],"allocation":[52],"theoretically":[54],"deduced,":[55],"which":[56],"directive":[59],"significance":[60],"practical":[63],"implementation":[64],"proposed":[67,116],"method.":[68],"Furthermore,":[69],"possesses":[72],"feasibility":[73],"resistance":[77],"smaller":[79],"than":[80,88],"50":[81],"\u03a9":[82],"metering":[84],"noise":[85],"lower":[87],"1%.":[89],"performance":[91,122],"tested":[96],"on":[97],"12.66":[99],"kV,":[100],"69-bus":[101],"network":[103],"model":[104],"established":[105],"real-time":[108],"digital":[109],"simulator.":[110],"Simulation":[111],"results":[112],"verified":[113],"that":[114],"good":[121],"various":[124],"scenarios.":[125]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":5},{"year":2024,"cited_by_count":10},{"year":2023,"cited_by_count":11},{"year":2022,"cited_by_count":13},{"year":2021,"cited_by_count":3}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
