{"id":"https://openalex.org/W2625360904","doi":"https://doi.org/10.1109/tii.2017.2714675","title":"Current Sensor Fault-Tolerant Control for Direct Torque Control of Induction Motor Drive Using Flux-Linkage Observer","display_name":"Current Sensor Fault-Tolerant Control for Direct Torque Control of Induction Motor Drive Using Flux-Linkage Observer","publication_year":2017,"publication_date":"2017-06-12","ids":{"openalex":"https://openalex.org/W2625360904","doi":"https://doi.org/10.1109/tii.2017.2714675","mag":"2625360904"},"language":"en","primary_location":{"id":"doi:10.1109/tii.2017.2714675","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tii.2017.2714675","pdf_url":null,"source":{"id":"https://openalex.org/S184777250","display_name":"IEEE Transactions on Industrial Informatics","issn_l":"1551-3203","issn":["1551-3203","1941-0050"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Informatics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5084203694","display_name":"Murli Manohar","orcid":"https://orcid.org/0000-0002-2290-2270"},"institutions":[{"id":"https://openalex.org/I189109744","display_name":"Indian Institute of Technology Dhanbad","ror":"https://ror.org/013v3cc28","country_code":"IN","type":"education","lineage":["https://openalex.org/I189109744"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"Murli Manohar","raw_affiliation_strings":["Indian Institute of Technology (Indian School of Mines) Dhanbad, Dhanbad, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Indian Institute of Technology (Indian School of Mines) Dhanbad, Dhanbad, India","institution_ids":["https://openalex.org/I189109744"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5089312092","display_name":"Sukanta Das","orcid":"https://orcid.org/0000-0002-6697-468X"},"institutions":[{"id":"https://openalex.org/I189109744","display_name":"Indian Institute of Technology Dhanbad","ror":"https://ror.org/013v3cc28","country_code":"IN","type":"education","lineage":["https://openalex.org/I189109744"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Sukanta Das","raw_affiliation_strings":["Indian Institute of Technology (Indian School of Mines) Dhanbad, Dhanbad, India"],"raw_orcid":"https://orcid.org/0000-0002-6697-468X","affiliations":[{"raw_affiliation_string":"Indian Institute of Technology (Indian School of Mines) Dhanbad, Dhanbad, India","institution_ids":["https://openalex.org/I189109744"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5084203694"],"corresponding_institution_ids":["https://openalex.org/I189109744"],"apc_list":null,"apc_paid":null,"fwci":10.4066,"has_fulltext":false,"cited_by_count":135,"citation_normalized_percentile":{"value":0.98628067,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":90,"max":100},"biblio":{"volume":"13","issue":"6","first_page":"2824","last_page":"2833"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9927999973297119,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10504","display_name":"Sensorless Control of Electric Motors","score":0.9926999807357788,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/flux-linkage","display_name":"Flux linkage","score":0.8066784143447876},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.750217616558075},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.6648595333099365},{"id":"https://openalex.org/keywords/current-sensor","display_name":"Current sensor","score":0.6575113534927368},{"id":"https://openalex.org/keywords/induction-motor","display_name":"Induction motor","score":0.6151013970375061},{"id":"https://openalex.org/keywords/direct-torque-control","display_name":"Direct torque control","score":0.5787595510482788},{"id":"https://openalex.org/keywords/fault-tolerance","display_name":"Fault tolerance","score":0.5740424394607544},{"id":"https://openalex.org/keywords/control-reconfiguration","display_name":"Control reconfiguration","score":0.5530029535293579},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.5479554533958435},{"id":"https://openalex.org/keywords/torque","display_name":"Torque","score":0.5457777380943298},{"id":"https://openalex.org/keywords/observer","display_name":"Observer (physics)","score":0.5167214274406433},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.4725225567817688},{"id":"https://openalex.org/keywords/vector-control","display_name":"Vector control","score":0.4587424695491791},{"id":"https://openalex.org/keywords/matlab","display_name":"MATLAB","score":0.4425141513347626},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.4272949695587158},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4257259964942932},{"id":"https://openalex.org/keywords/current","display_name":"Current (fluid)","score":0.2734050154685974},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.17054980993270874},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.17050379514694214},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.08731472492218018},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.06856119632720947}],"concepts":[{"id":"https://openalex.org/C155343825","wikidata":"https://www.wikidata.org/wiki/Q4374882","display_name":"Flux linkage","level":5,"score":0.8066784143447876},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.750217616558075},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.6648595333099365},{"id":"https://openalex.org/C55000061","wikidata":"https://www.wikidata.org/wiki/Q24894777","display_name":"Current sensor","level":3,"score":0.6575113534927368},{"id":"https://openalex.org/C80962145","wikidata":"https://www.wikidata.org/wiki/Q207450","display_name":"Induction motor","level":3,"score":0.6151013970375061},{"id":"https://openalex.org/C109871850","wikidata":"https://www.wikidata.org/wiki/Q1227571","display_name":"Direct torque control","level":4,"score":0.5787595510482788},{"id":"https://openalex.org/C63540848","wikidata":"https://www.wikidata.org/wiki/Q3140932","display_name":"Fault tolerance","level":2,"score":0.5740424394607544},{"id":"https://openalex.org/C119701452","wikidata":"https://www.wikidata.org/wiki/Q5165881","display_name":"Control reconfiguration","level":2,"score":0.5530029535293579},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5479554533958435},{"id":"https://openalex.org/C144171764","wikidata":"https://www.wikidata.org/wiki/Q48103","display_name":"Torque","level":2,"score":0.5457777380943298},{"id":"https://openalex.org/C2780704645","wikidata":"https://www.wikidata.org/wiki/Q9251458","display_name":"Observer (physics)","level":2,"score":0.5167214274406433},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.4725225567817688},{"id":"https://openalex.org/C152060993","wikidata":"https://www.wikidata.org/wiki/Q1759392","display_name":"Vector control","level":4,"score":0.4587424695491791},{"id":"https://openalex.org/C2780365114","wikidata":"https://www.wikidata.org/wiki/Q169478","display_name":"MATLAB","level":2,"score":0.4425141513347626},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.4272949695587158},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4257259964942932},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.2734050154685974},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.17054980993270874},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.17050379514694214},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.08731472492218018},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.06856119632720947},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tii.2017.2714675","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tii.2017.2714675","pdf_url":null,"source":{"id":"https://openalex.org/S184777250","display_name":"IEEE Transactions on Industrial Informatics","issn_l":"1551-3203","issn":["1551-3203","1941-0050"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Informatics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Peace, Justice and strong institutions","score":0.7400000095367432,"id":"https://metadata.un.org/sdg/16"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":36,"referenced_works":["https://openalex.org/W1906935456","https://openalex.org/W1968000373","https://openalex.org/W1972194661","https://openalex.org/W1975877807","https://openalex.org/W1984786788","https://openalex.org/W1993607986","https://openalex.org/W1993880634","https://openalex.org/W2007576168","https://openalex.org/W2007831174","https://openalex.org/W2008119538","https://openalex.org/W2022731643","https://openalex.org/W2038419241","https://openalex.org/W2041490733","https://openalex.org/W2055319365","https://openalex.org/W2077466628","https://openalex.org/W2083178888","https://openalex.org/W2092161065","https://openalex.org/W2093369143","https://openalex.org/W2103112267","https://openalex.org/W2108182974","https://openalex.org/W2130326526","https://openalex.org/W2130540853","https://openalex.org/W2131299455","https://openalex.org/W2138297575","https://openalex.org/W2139853183","https://openalex.org/W2152659969","https://openalex.org/W2154152725","https://openalex.org/W2161021171","https://openalex.org/W2161634311","https://openalex.org/W2163583509","https://openalex.org/W2180955833","https://openalex.org/W2293758036","https://openalex.org/W2314810091","https://openalex.org/W2597057696","https://openalex.org/W3146533620","https://openalex.org/W4237394575"],"related_works":["https://openalex.org/W2380608580","https://openalex.org/W1976520621","https://openalex.org/W2357927501","https://openalex.org/W2124993922","https://openalex.org/W2351481361","https://openalex.org/W2134656663","https://openalex.org/W2171732752","https://openalex.org/W2038068874","https://openalex.org/W3117954907","https://openalex.org/W2356164680"],"abstract_inverted_index":{"This":[0],"paper":[1],"proposes":[2],"a":[3,89,154],"novel":[4],"fault-tolerant":[5],"control":[6,12,131],"(FTC)":[7],"scheme":[8,32,73,115,138],"for":[9,61],"direct":[10],"torque":[11],"of":[13,36,40,64,77,79,85,164],"induction":[14],"motor":[15,55],"(IM)":[16],"drives":[17],"against":[18],"the":[19,29,34,41,45,54,62,65,75,83,86,94,100,107,162,165],"line":[20,56,80],"current":[21,57,71,81,103,112],"sensor":[22,37,66,113],"failures.":[23],"Three":[24],"major":[25],"steps":[26],"involved":[27],"in":[28,53,120,144],"proposed":[30,111,137],"FTC":[31,114],"are":[33,150],"detection":[35,63],"fault,":[38,67],"isolation":[39],"same,":[42],"and":[43,97,118,141],"finally,":[44],"reconfiguration":[46],"by":[47],"proper":[48],"estimation.":[49],"Third-difference":[50],"operator":[51],"employed":[52],"is":[58,116,139],"found":[59],"suitable":[60],"while":[68],"flux-linkage":[69],"observer-based":[70],"estimation":[72,78],"performs":[74],"task":[76],"post":[82],"occurrence":[84],"fault.":[87],"Furthermore,":[88],"decision-making":[90],"logic":[91],"circuitry":[92],"isolates":[93],"faulty":[95],"signal":[96,104],"simultaneously":[98],"selects":[99],"appropriate":[101],"estimated":[102],"to":[105,160],"make":[106],"drive":[108,157],"fault-tolerant.":[109],"The":[110,136,146],"simple":[117],"unique":[119],"nature.":[121],"Moreover,":[122],"it":[123],"can":[124],"be":[125],"universally":[126],"applied":[127],"with":[128],"any":[129],"speed":[130],"schemes":[132],"involving":[133],"IM":[134,156],"drive.":[135],"simulated":[140],"extensively":[142],"tested":[143],"MATLAB/Simulink.":[145],"obtained":[147],"simulation":[148],"results":[149],"also":[151],"verified":[152],"using":[153],"dSPACE-1104-based":[155],"laboratory":[158],"prototype":[159],"show":[161],"effectiveness":[163],"scheme.":[166]},"counts_by_year":[{"year":2026,"cited_by_count":3},{"year":2025,"cited_by_count":10},{"year":2024,"cited_by_count":12},{"year":2023,"cited_by_count":12},{"year":2022,"cited_by_count":22},{"year":2021,"cited_by_count":25},{"year":2020,"cited_by_count":22},{"year":2019,"cited_by_count":20},{"year":2018,"cited_by_count":8},{"year":2017,"cited_by_count":1}],"updated_date":"2026-05-07T13:39:58.223016","created_date":"2025-10-10T00:00:00"}
