{"id":"https://openalex.org/W7117117231","doi":"https://doi.org/10.1109/tie.2025.3632525","title":"DC Injection Based Fault-Tolerant Control of Modular PMSM Drives Under Single/Hybrid Open-Switch Faults","display_name":"DC Injection Based Fault-Tolerant Control of Modular PMSM Drives Under Single/Hybrid Open-Switch Faults","publication_year":2025,"publication_date":"2025-12-24","ids":{"openalex":"https://openalex.org/W7117117231","doi":"https://doi.org/10.1109/tie.2025.3632525"},"language":"en","primary_location":{"id":"doi:10.1109/tie.2025.3632525","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2025.3632525","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://nottingham-repository.worktribe.com/file/58449828/1/TIE3632525-3","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5121244618","display_name":"Yutao Du","orcid":null},"institutions":[{"id":"https://openalex.org/I142263535","display_name":"University of Nottingham","ror":"https://ror.org/01ee9ar58","country_code":"GB","type":"education","lineage":["https://openalex.org/I142263535"]}],"countries":["GB"],"is_corresponding":true,"raw_author_name":"Yutao Du","raw_affiliation_strings":["Power Electronics, Machines and Control (PEMC) Research Institute, University of Nottingham, Nottingham, U.K"],"raw_orcid":"https://orcid.org/0000-0001-6426-285X","affiliations":[{"raw_affiliation_string":"Power Electronics, Machines and Control (PEMC) Research Institute, University of Nottingham, Nottingham, U.K","institution_ids":["https://openalex.org/I142263535"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5121145066","display_name":"Yongbo Li","orcid":null},"institutions":[{"id":"https://openalex.org/I125839683","display_name":"Beijing Institute of Technology","ror":"https://ror.org/01skt4w74","country_code":"CN","type":"education","lineage":["https://openalex.org/I125839683","https://openalex.org/I890469752"]},{"id":"https://openalex.org/I4210094879","display_name":"Shandong Institute of Automation","ror":"https://ror.org/00qdtba35","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210094879","https://openalex.org/I4210142748"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yongbo Li","raw_affiliation_strings":["School of Automation, and the Key Laboratory for Intelligent Control and Decision on Complex Systems, Beijing Institute of Technology, Beijing, China"],"raw_orcid":"https://orcid.org/0009-0004-0421-2999","affiliations":[{"raw_affiliation_string":"School of Automation, and the Key Laboratory for Intelligent Control and Decision on Complex Systems, Beijing Institute of Technology, Beijing, China","institution_ids":["https://openalex.org/I4210094879","https://openalex.org/I125839683"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Kui Wang","orcid":"https://orcid.org/0000-0003-3928-9318"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Kui Wang","raw_affiliation_strings":["State Key Laboratory of Power System, Department of Electrical Engineering, Tsinghua University, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0003-3928-9318","affiliations":[{"raw_affiliation_string":"State Key Laboratory of Power System, Department of Electrical Engineering, Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Zedong Zheng","orcid":"https://orcid.org/0000-0003-4392-3502"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zedong Zheng","raw_affiliation_strings":["State Key Laboratory of Power System, Department of Electrical Engineering, Tsinghua University, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0003-4392-3502","affiliations":[{"raw_affiliation_string":"State Key Laboratory of Power System, Department of Electrical Engineering, Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5108336866","display_name":"Chris Gerada","orcid":null},"institutions":[{"id":"https://openalex.org/I142263535","display_name":"University of Nottingham","ror":"https://ror.org/01ee9ar58","country_code":"GB","type":"education","lineage":["https://openalex.org/I142263535"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Chris Gerada","raw_affiliation_strings":["Power Electronics, Machines and Control (PEMC) Research Institute, University of Nottingham, Nottingham, U.K"],"raw_orcid":"https://orcid.org/0000-0003-4707-4480","affiliations":[{"raw_affiliation_string":"Power Electronics, Machines and Control (PEMC) Research Institute, University of Nottingham, Nottingham, U.K","institution_ids":["https://openalex.org/I142263535"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5121244618"],"corresponding_institution_ids":["https://openalex.org/I142263535"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":true,"cited_by_count":0,"citation_normalized_percentile":{"value":0.53647599,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"73","issue":"5","first_page":"6646","last_page":"6656"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9122999906539917,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9122999906539917,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.017000000923871994,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10504","display_name":"Sensorless Control of Electric Motors","score":0.01360000018030405,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.71670001745224},{"id":"https://openalex.org/keywords/modular-design","display_name":"Modular design","score":0.7059000134468079},{"id":"https://openalex.org/keywords/torque","display_name":"Torque","score":0.6392999887466431},{"id":"https://openalex.org/keywords/direct-torque-control","display_name":"Direct torque control","score":0.46939998865127563},{"id":"https://openalex.org/keywords/copper-loss","display_name":"Copper loss","score":0.46560001373291016},{"id":"https://openalex.org/keywords/residual","display_name":"Residual","score":0.4487000107765198},{"id":"https://openalex.org/keywords/fault-tolerance","display_name":"Fault tolerance","score":0.44130000472068787},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.428600013256073},{"id":"https://openalex.org/keywords/synchronous-motor","display_name":"Synchronous motor","score":0.423799991607666},{"id":"https://openalex.org/keywords/scheme","display_name":"Scheme (mathematics)","score":0.4185999929904938}],"concepts":[{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.71670001745224},{"id":"https://openalex.org/C101468663","wikidata":"https://www.wikidata.org/wiki/Q1620158","display_name":"Modular design","level":2,"score":0.7059000134468079},{"id":"https://openalex.org/C144171764","wikidata":"https://www.wikidata.org/wiki/Q48103","display_name":"Torque","level":2,"score":0.6392999887466431},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5803999900817871},{"id":"https://openalex.org/C109871850","wikidata":"https://www.wikidata.org/wiki/Q1227571","display_name":"Direct torque control","level":4,"score":0.46939998865127563},{"id":"https://openalex.org/C61906436","wikidata":"https://www.wikidata.org/wiki/Q1225223","display_name":"Copper loss","level":3,"score":0.46560001373291016},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.453900009393692},{"id":"https://openalex.org/C155512373","wikidata":"https://www.wikidata.org/wiki/Q287450","display_name":"Residual","level":2,"score":0.4487000107765198},{"id":"https://openalex.org/C63540848","wikidata":"https://www.wikidata.org/wiki/Q3140932","display_name":"Fault tolerance","level":2,"score":0.44130000472068787},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.428600013256073},{"id":"https://openalex.org/C71376005","wikidata":"https://www.wikidata.org/wiki/Q845675","display_name":"Synchronous motor","level":2,"score":0.423799991607666},{"id":"https://openalex.org/C77618280","wikidata":"https://www.wikidata.org/wiki/Q1155772","display_name":"Scheme (mathematics)","level":2,"score":0.4185999929904938},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.40560001134872437},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.38609999418258667},{"id":"https://openalex.org/C76684090","wikidata":"https://www.wikidata.org/wiki/Q3842034","display_name":"DC motor","level":2,"score":0.3644999861717224},{"id":"https://openalex.org/C2777718703","wikidata":"https://www.wikidata.org/wiki/Q6723706","display_name":"Machine control","level":2,"score":0.34880000352859497},{"id":"https://openalex.org/C173161252","wikidata":"https://www.wikidata.org/wiki/Q1435839","display_name":"AC motor","level":3,"score":0.34769999980926514},{"id":"https://openalex.org/C154750914","wikidata":"https://www.wikidata.org/wiki/Q4304910","display_name":"Motor drive","level":2,"score":0.3440000116825104},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.34150001406669617},{"id":"https://openalex.org/C123414225","wikidata":"https://www.wikidata.org/wiki/Q1422221","display_name":"Current loop","level":3,"score":0.3361000120639801},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3255999982357025},{"id":"https://openalex.org/C80551277","wikidata":"https://www.wikidata.org/wiki/Q11210","display_name":"Coordinate system","level":2,"score":0.32260000705718994},{"id":"https://openalex.org/C2986944758","wikidata":"https://www.wikidata.org/wiki/Q845675","display_name":"Permanent magnet synchronous motor","level":3,"score":0.29739999771118164},{"id":"https://openalex.org/C204054776","wikidata":"https://www.wikidata.org/wiki/Q2444432","display_name":"Torque motor","level":5,"score":0.29019999504089355},{"id":"https://openalex.org/C173871940","wikidata":"https://www.wikidata.org/wiki/Q471846","display_name":"Three-phase","level":3,"score":0.2831000089645386},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.28209999203681946},{"id":"https://openalex.org/C158411068","wikidata":"https://www.wikidata.org/wiki/Q2720568","display_name":"Digital control","level":2,"score":0.2687999904155731},{"id":"https://openalex.org/C4848560","wikidata":"https://www.wikidata.org/wiki/Q1326752","display_name":"Motor controller","level":3,"score":0.2667999863624573},{"id":"https://openalex.org/C137813230","wikidata":"https://www.wikidata.org/wiki/Q2996165","display_name":"Motor control","level":2,"score":0.25600001215934753},{"id":"https://openalex.org/C2778915421","wikidata":"https://www.wikidata.org/wiki/Q3643177","display_name":"Performance improvement","level":2,"score":0.2531999945640564},{"id":"https://openalex.org/C2776617710","wikidata":"https://www.wikidata.org/wiki/Q28454009","display_name":"Permanent magnet motor","level":3,"score":0.25110000371932983}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/tie.2025.3632525","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2025.3632525","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},{"id":"pmh:oai:nottingham-repository.worktribe.com:58449828","is_oa":true,"landing_page_url":"https://nottingham-repository.worktribe.com/output/58449828","pdf_url":"https://nottingham-repository.worktribe.com/file/58449828/1/TIE3632525-3","source":{"id":"https://openalex.org/S4306402483","display_name":"Repository@Nottingham (University of Nottingham)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I142263535","host_organization_name":"University of Nottingham","host_organization_lineage":["https://openalex.org/I142263535"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"acceptedVersion"}],"best_oa_location":{"id":"pmh:oai:nottingham-repository.worktribe.com:58449828","is_oa":true,"landing_page_url":"https://nottingham-repository.worktribe.com/output/58449828","pdf_url":"https://nottingham-repository.worktribe.com/file/58449828/1/TIE3632525-3","source":{"id":"https://openalex.org/S4306402483","display_name":"Repository@Nottingham (University of Nottingham)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I142263535","host_organization_name":"University of Nottingham","host_organization_lineage":["https://openalex.org/I142263535"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"acceptedVersion"},"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G2473988173","display_name":null,"funder_award_id":"U2106217","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"}],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"}],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W7117117231.pdf","grobid_xml":"https://content.openalex.org/works/W7117117231.grobid-xml"},"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"Modular":[0],"permanent":[1],"magnet":[2],"synchronous":[3],"motor":[4,13,158],"drive":[5,159],"systems":[6],"have":[7],"recently":[8],"received":[9],"increasing":[10,31],"attention":[11],"in":[12,95,155],"applications":[14],"with":[15,161],"high-reliability":[16],"requirements.":[17],"The":[18],"traditional":[19],"methods":[20],"make":[21],"it":[22],"difficult":[23],"to":[24],"guarantee":[25],"the":[26,32,55,60,66,72,75,82,99,114,126,134,143,147,150],"postfault":[27],"tolerance":[28],"performance":[29,138,148],"without":[30],"hardware":[33],"or":[34],"controller":[35],"complexity.":[36],"To":[37],"address":[38],"this":[39],"problem,":[40],"a":[41,105,121,156,162],"direct":[42],"current":[43,110,116],"(dc)":[44],"injection-based":[45],"single/hybrid":[46],"open-switch":[47],"fault-tolerant":[48],"control":[49],"strategy":[50],"is":[51,85,102,131,153],"proposed,":[52],"which":[53],"eliminates":[54],"fault-generated":[56],"torque":[57,68],"pulsation,":[58],"reduces":[59],"system":[61,109,160],"copper":[62,129],"loss,":[63],"and":[64,92,113,133,137],"improves":[65],"system's":[67],"output":[69],"capability":[70],"through":[71],"collaboration":[73],"of":[74,125,149,165],"residual":[76],"healthy":[77],"switches":[78],"among":[79],"submodules.":[80],"First,":[81],"injection":[83,101],"scheme":[84],"designed":[86],"separately":[87],"for":[88,142],"single":[89],"switch":[90],"fault":[91],"two-switch":[93],"faults":[94],"different":[96],"bridges.":[97],"Then,":[98],"dc":[100],"achieved":[103],"by":[104],"combined":[106],"static-rotate":[107],"coordinate":[108],"loop":[111],"structure,":[112],"postinjection":[115,127],"characteristics":[117],"are":[118,140],"analyzed.":[119],"Furthermore,":[120],"generalized":[122],"mathematical":[123],"model":[124],"system-submodule-phase":[128],"loss":[130],"established,":[132],"optimal":[135],"solution":[136],"analysis":[139],"derived":[141],"optimization":[144],"objective.":[145],"Finally,":[146],"proposed":[151],"method":[152],"verified":[154],"dual-module":[157],"phase":[163],"difference":[164],"<inline-formula":[166],"xmlns:mml=\"http://www.w3.org/1998/Math/MathML\"":[167],"xmlns:xlink=\"http://www.w3.org/1999/xlink\"><tex-math":[168],"notation=\"LaTeX\">$\\boldsymbol{\\pi}$</tex-math></inline-formula>/6.":[169]},"counts_by_year":[],"updated_date":"2026-05-10T08:33:47.465468","created_date":"2025-12-24T00:00:00"}
