{"id":"https://openalex.org/W4416513595","doi":"https://doi.org/10.1109/tie.2025.3626639","title":"Reactive Power Control Strategy for Isolated Single-Stage AC\u2013DC Converter Based on Dual Active Bridge","display_name":"Reactive Power Control Strategy for Isolated Single-Stage AC\u2013DC Converter Based on Dual Active Bridge","publication_year":2025,"publication_date":"2025-11-21","ids":{"openalex":"https://openalex.org/W4416513595","doi":"https://doi.org/10.1109/tie.2025.3626639"},"language":null,"primary_location":{"id":"doi:10.1109/tie.2025.3626639","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2025.3626639","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5052043342","display_name":"Zhiqiang Guo","orcid":"https://orcid.org/0000-0003-1659-2445"},"institutions":[{"id":"https://openalex.org/I125839683","display_name":"Beijing Institute of Technology","ror":"https://ror.org/01skt4w74","country_code":"CN","type":"education","lineage":["https://openalex.org/I125839683","https://openalex.org/I890469752"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhiqiang Guo","raw_affiliation_strings":["School of Automation, Beijing Institute of Technology, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0003-1659-2445","affiliations":[{"raw_affiliation_string":"School of Automation, Beijing Institute of Technology, Beijing, China","institution_ids":["https://openalex.org/I125839683"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5050204842","display_name":"Z Y Zhang","orcid":"https://orcid.org/0009-0006-7674-7225"},"institutions":[{"id":"https://openalex.org/I125839683","display_name":"Beijing Institute of Technology","ror":"https://ror.org/01skt4w74","country_code":"CN","type":"education","lineage":["https://openalex.org/I125839683","https://openalex.org/I890469752"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhiruo Zhang","raw_affiliation_strings":["School of Automation, Beijing Institute of Technology, Beijing, China"],"raw_orcid":"https://orcid.org/0009-0006-7674-7225","affiliations":[{"raw_affiliation_string":"School of Automation, Beijing Institute of Technology, Beijing, China","institution_ids":["https://openalex.org/I125839683"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100624522","display_name":"Bin Zhang","orcid":"https://orcid.org/0000-0002-9237-8144"},"institutions":[{"id":"https://openalex.org/I125839683","display_name":"Beijing Institute of Technology","ror":"https://ror.org/01skt4w74","country_code":"CN","type":"education","lineage":["https://openalex.org/I125839683","https://openalex.org/I890469752"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Bin Zhang","raw_affiliation_strings":["School of Automation, Beijing Institute of Technology, Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Automation, Beijing Institute of Technology, Beijing, China","institution_ids":["https://openalex.org/I125839683"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I125839683"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.29441081,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"73","issue":"3","first_page":"3953","last_page":"3965"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9664999842643738,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9664999842643738,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.010599999688565731,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.00860000029206276,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.8034999966621399},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.6226000189781189},{"id":"https://openalex.org/keywords/power-control","display_name":"Power control","score":0.5467000007629395},{"id":"https://openalex.org/keywords/inductor","display_name":"Inductor","score":0.5166000127792358},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.47940000891685486},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.44769999384880066},{"id":"https://openalex.org/keywords/power-factor","display_name":"Power factor","score":0.4000999927520752},{"id":"https://openalex.org/keywords/three-phase","display_name":"Three-phase","score":0.38530001044273376},{"id":"https://openalex.org/keywords/dual","display_name":"Dual (grammatical number)","score":0.3677000105381012}],"concepts":[{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.8034999966621399},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6226000189781189},{"id":"https://openalex.org/C56685638","wikidata":"https://www.wikidata.org/wiki/Q2300474","display_name":"Power control","level":3,"score":0.5467000007629395},{"id":"https://openalex.org/C144534570","wikidata":"https://www.wikidata.org/wiki/Q5325","display_name":"Inductor","level":3,"score":0.5166000127792358},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.47940000891685486},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.44769999384880066},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.43290001153945923},{"id":"https://openalex.org/C64424096","wikidata":"https://www.wikidata.org/wiki/Q750454","display_name":"Power factor","level":3,"score":0.4000999927520752},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3982999920845032},{"id":"https://openalex.org/C173871940","wikidata":"https://www.wikidata.org/wiki/Q471846","display_name":"Three-phase","level":3,"score":0.38530001044273376},{"id":"https://openalex.org/C2780980858","wikidata":"https://www.wikidata.org/wiki/Q110022","display_name":"Dual (grammatical number)","level":2,"score":0.3677000105381012},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.36570000648498535},{"id":"https://openalex.org/C59407501","wikidata":"https://www.wikidata.org/wiki/Q550341","display_name":"Volt-ampere reactive","level":5,"score":0.3521000146865845},{"id":"https://openalex.org/C78336795","wikidata":"https://www.wikidata.org/wiki/Q760134","display_name":"Boost converter","level":3,"score":0.33980000019073486},{"id":"https://openalex.org/C2778512005","wikidata":"https://www.wikidata.org/wiki/Q1545300","display_name":"H bridge","level":4,"score":0.31540000438690186},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.30709999799728394},{"id":"https://openalex.org/C151799858","wikidata":"https://www.wikidata.org/wiki/Q587008","display_name":"Switched-mode power supply","level":3,"score":0.30570000410079956},{"id":"https://openalex.org/C150818752","wikidata":"https://www.wikidata.org/wiki/Q83804","display_name":"Buck converter","level":3,"score":0.29820001125335693},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.295199990272522},{"id":"https://openalex.org/C196226539","wikidata":"https://www.wikidata.org/wiki/Q7940752","display_name":"Voltage regulation","level":3,"score":0.29100000858306885},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.2831999957561493},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.28060001134872437},{"id":"https://openalex.org/C148367217","wikidata":"https://www.wikidata.org/wiki/Q550341","display_name":"Volt-ampere","level":5,"score":0.26190000772476196},{"id":"https://openalex.org/C178911571","wikidata":"https://www.wikidata.org/wiki/Q593143","display_name":"Power electronics","level":3,"score":0.25110000371932983},{"id":"https://openalex.org/C29586797","wikidata":"https://www.wikidata.org/wiki/Q5163663","display_name":"Constant power circuit","level":4,"score":0.2506999969482422}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tie.2025.3626639","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2025.3626639","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G7734870994","display_name":null,"funder_award_id":"52477174","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"}],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"This":[0],"article":[1],"presents":[2],"a":[3,159,195,201,208],"reactive":[4,97,132,178,222],"power":[5,98,114,126,133,179,185,223],"control":[6,22,86,99,134,141,180,190,224],"strategy":[7,135,142,191],"for":[8,88,143],"the":[9,41,45,51,56,65,73,76,89,101,108,113,117,131,140,147,152,167,171,188,216,221],"isolated":[10],"single-stage":[11],"dual":[12],"active":[13],"bridge":[14],"(DAB)":[15],"ac\u2013dc":[16,91,154,198],"converter.":[17],"Triple":[18],"phase":[19,42,77],"shift":[20,78],"(TPS)":[21],"is":[23,60,69,93,174,192],"employed":[24],"to":[25,95,176,194],"achieve":[26,177],"zero-voltage":[27],"switching":[28],"and":[29,48,104,127,207,218],"reduce":[30],"conduction":[31],"losses,":[32],"ensuring":[33],"globally":[34],"optimal":[35,144],"working":[36,122,145],"modes.":[37],"The":[38,119,212],"impact":[39],"of":[40,55,75,116,162,170,220],"difference":[43],"between":[44],"grid":[46,102],"voltage":[47,206],"current":[49,53,67],"on":[50,100,107,139],"input":[52,66,205],"direction":[54,68],"DAB":[57,90,153,197],"dc\u2013dc":[58],"converter":[59,92,155,199],"analyzed.":[61],"Under":[62],"TPS":[63],"control,":[64],"regulated":[70],"by":[71],"adjusting":[72],"polarity":[74],"angle":[79,129],"(i.e.,":[80],"positive":[81],"or":[82],"negative":[83],"values).":[84],"A":[85],"algorithm":[87],"proposed":[94,148,189],"enable":[96],"side":[103],"output":[105,210],"regulation":[106],"load":[109,125,163,184],"side,":[110],"thereby":[111],"improving":[112],"quality":[115],"system.":[118],"variations":[120],"in":[121],"modes":[123],"concerning":[124],"line-frequency":[128],"under":[130],"are":[136],"investigated.":[137],"Based":[138],"modes,":[146],"method":[149],"ensures":[150],"that":[151],"operates":[156],"efficiently":[157],"across":[158],"wide":[160],"range":[161],"power.":[164],"In":[165],"addition,":[166],"design":[168],"methodology":[169],"series":[172],"inductor":[173],"analyzed":[175],"while":[181],"meeting":[182],"target":[183],"requirements.":[186],"Finally,":[187],"applied":[193],"1-kW":[196],"with":[200],"220":[202],"V/50":[203],"Hz":[204],"200-V":[209],"voltage.":[211],"experimental":[213],"results":[214],"validate":[215],"feasibility":[217],"effectiveness":[219],"strategy.":[225]},"counts_by_year":[],"updated_date":"2026-03-01T06:05:34.837733","created_date":"2025-11-23T00:00:00"}
