{"id":"https://openalex.org/W4417052264","doi":"https://doi.org/10.1109/tie.2025.3610761","title":"Multimode Fault-Tolerant Predictive Control for Parallel Three-Level Power Converters","display_name":"Multimode Fault-Tolerant Predictive Control for Parallel Three-Level Power Converters","publication_year":2025,"publication_date":"2025-12-05","ids":{"openalex":"https://openalex.org/W4417052264","doi":"https://doi.org/10.1109/tie.2025.3610761"},"language":null,"primary_location":{"id":"doi:10.1109/tie.2025.3610761","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2025.3610761","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100763971","display_name":"Haoyu Chen","orcid":"https://orcid.org/0000-0002-3041-6555"},"institutions":[{"id":"https://openalex.org/I154099455","display_name":"Shandong University","ror":"https://ror.org/0207yh398","country_code":"CN","type":"education","lineage":["https://openalex.org/I154099455"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Haoyu Chen","raw_affiliation_strings":["School of Electrical Engineering, Shandong University, Jinan, China"],"affiliations":[{"raw_affiliation_string":"School of Electrical Engineering, Shandong University, Jinan, China","institution_ids":["https://openalex.org/I154099455"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100332642","display_name":"Zhen Li","orcid":"https://orcid.org/0000-0002-9652-2174"},"institutions":[{"id":"https://openalex.org/I154099455","display_name":"Shandong University","ror":"https://ror.org/0207yh398","country_code":"CN","type":"education","lineage":["https://openalex.org/I154099455"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhen Li","raw_affiliation_strings":["School of Electrical Engineering, Shandong University, Jinan, China"],"affiliations":[{"raw_affiliation_string":"School of Electrical Engineering, Shandong University, Jinan, China","institution_ids":["https://openalex.org/I154099455"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5058838938","display_name":"Zhenbin Zhang","orcid":"https://orcid.org/0000-0002-2453-7502"},"institutions":[{"id":"https://openalex.org/I154099455","display_name":"Shandong University","ror":"https://ror.org/0207yh398","country_code":"CN","type":"education","lineage":["https://openalex.org/I154099455"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhenbin Zhang","raw_affiliation_strings":["School of Electrical Engineering, Shandong University, Jinan, China"],"affiliations":[{"raw_affiliation_string":"School of Electrical Engineering, Shandong University, Jinan, China","institution_ids":["https://openalex.org/I154099455"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5100763971"],"corresponding_institution_ids":["https://openalex.org/I154099455"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.39836504,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"73","issue":"4","first_page":"6014","last_page":"6025"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.8277999758720398,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.8277999758720398,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.057500001043081284,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.046300001442432404,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/model-predictive-control","display_name":"Model predictive control","score":0.6948999762535095},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.6111999750137329},{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.5857999920845032},{"id":"https://openalex.org/keywords/control-reconfiguration","display_name":"Control reconfiguration","score":0.5708000063896179},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.5257999897003174},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.482699990272522},{"id":"https://openalex.org/keywords/fault-tolerance","display_name":"Fault tolerance","score":0.41290000081062317},{"id":"https://openalex.org/keywords/multi-mode-optical-fiber","display_name":"Multi-mode optical fiber","score":0.41100001335144043},{"id":"https://openalex.org/keywords/modulation","display_name":"Modulation (music)","score":0.40209999680519104}],"concepts":[{"id":"https://openalex.org/C172205157","wikidata":"https://www.wikidata.org/wiki/Q1782962","display_name":"Model predictive control","level":3,"score":0.6948999762535095},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6111999750137329},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.5857999920845032},{"id":"https://openalex.org/C119701452","wikidata":"https://www.wikidata.org/wiki/Q5165881","display_name":"Control reconfiguration","level":2,"score":0.5708000063896179},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5558000206947327},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.5257999897003174},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.482699990272522},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4717000126838684},{"id":"https://openalex.org/C63540848","wikidata":"https://www.wikidata.org/wiki/Q3140932","display_name":"Fault tolerance","level":2,"score":0.41290000081062317},{"id":"https://openalex.org/C101645829","wikidata":"https://www.wikidata.org/wiki/Q1781857","display_name":"Multi-mode optical fiber","level":3,"score":0.41100001335144043},{"id":"https://openalex.org/C123079801","wikidata":"https://www.wikidata.org/wiki/Q750240","display_name":"Modulation (music)","level":2,"score":0.40209999680519104},{"id":"https://openalex.org/C56685638","wikidata":"https://www.wikidata.org/wiki/Q2300474","display_name":"Power control","level":3,"score":0.3919999897480011},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3856000006198883},{"id":"https://openalex.org/C152124472","wikidata":"https://www.wikidata.org/wiki/Q1204361","display_name":"Redundancy (engineering)","level":2,"score":0.3831000030040741},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3813000023365021},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.3758000135421753},{"id":"https://openalex.org/C126780896","wikidata":"https://www.wikidata.org/wiki/Q899871","display_name":"Distortion (music)","level":4,"score":0.3682999908924103},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.3537999987602234},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3467999994754791},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.3294999897480011},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.3224000036716461},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.3224000036716461},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.2921000123023987},{"id":"https://openalex.org/C150189527","wikidata":"https://www.wikidata.org/wiki/Q356674","display_name":"Reference model","level":2,"score":0.2838999927043915},{"id":"https://openalex.org/C18762648","wikidata":"https://www.wikidata.org/wiki/Q42213","display_name":"Work (physics)","level":2,"score":0.2768000066280365},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.2761000096797943},{"id":"https://openalex.org/C70452415","wikidata":"https://www.wikidata.org/wiki/Q3182448","display_name":"Predictive maintenance","level":2,"score":0.2648000121116638},{"id":"https://openalex.org/C11930861","wikidata":"https://www.wikidata.org/wiki/Q181417","display_name":"Frequency modulation","level":3,"score":0.2590000033378601},{"id":"https://openalex.org/C2781089630","wikidata":"https://www.wikidata.org/wiki/Q21856745","display_name":"Realization (probability)","level":2,"score":0.2531000077724457},{"id":"https://openalex.org/C2779679103","wikidata":"https://www.wikidata.org/wiki/Q5251805","display_name":"Degradation (telecommunications)","level":2,"score":0.2515000104904175}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tie.2025.3610761","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2025.3610761","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"The":[0],"consistently":[1],"high":[2],"failure":[3],"rates":[4],"of":[5,12,29,41,98,125],"power":[6,61],"devices":[7],"severely":[8],"degrade":[9],"the":[10,118,123,126],"reliability":[11],"parallel":[13],"three-level":[14],"converters,":[15],"requiring":[16],"fault-tolerant":[17,52,86],"control":[18,36,54,106],"to":[19,32],"ensure":[20],"postfault":[21,35],"stability.":[22],"However,":[23],"conventional":[24],"strategies":[25,87],"face":[26],"two":[27],"challenges":[28],"inadequate":[30],"capability":[31],"optimize":[33],"multiple":[34],"objectives":[37],"and":[38,63,84,101,112],"insufficient":[39],"utilization":[40],"healthy":[42,77,119],"components.":[43],"To":[44],"this":[45,47],"end,":[46],"work":[48],"proposes":[49],"a":[50,57,104],"multimode":[51],"predictive":[53,105],"approach.":[55],"First,":[56],"quantitative":[58],"model":[59],"correlating":[60],"factors":[62],"modulation":[64,102],"indices":[65],"with":[66,131],"fault":[67],"current":[68,109,115],"distortion":[69],"ranges":[70],"was":[71],"established,":[72],"revealing":[73],"constraints":[74],"imposed":[75],"by":[76],"component":[78],"freewheeling":[79],"capabilities.":[80],"Next,":[81],"internal-compensation-,":[82],"partial-external-compensation-,":[83],"full-external-compensation-based":[85],"are":[88],"developed":[89],"across":[90],"all":[91],"operational":[92],"modes.":[93],"Then,":[94],"through":[95],"deep":[96],"integration":[97],"reference":[99,110],"generation":[100],"within":[103],"framework,":[107],"dynamic":[108],"reconfiguration":[111],"zero-sequence":[113],"circulating":[114],"reshaping":[116],"maximize":[117],"resource":[120],"utilization.":[121],"Finally,":[122],"effectiveness":[124],"proposed":[127],"method":[128],"is":[129],"verified":[130],"experimental":[132],"results.":[133]},"counts_by_year":[],"updated_date":"2026-03-20T20:47:17.329874","created_date":"2025-12-05T00:00:00"}
