{"id":"https://openalex.org/W4408324376","doi":"https://doi.org/10.1109/tie.2025.3544228","title":"Single-Switch Soft-Switched High Step-Up DC\u2013DC Converter With Reduced Voltage Stress","display_name":"Single-Switch Soft-Switched High Step-Up DC\u2013DC Converter With Reduced Voltage Stress","publication_year":2025,"publication_date":"2025-03-11","ids":{"openalex":"https://openalex.org/W4408324376","doi":"https://doi.org/10.1109/tie.2025.3544228"},"language":"en","primary_location":{"id":"doi:10.1109/tie.2025.3544228","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2025.3544228","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5040317737","display_name":"Siamak Khalili","orcid":"https://orcid.org/0000-0001-9511-3232"},"institutions":[{"id":"https://openalex.org/I170013655","display_name":"Isfahan University of Technology","ror":"https://ror.org/00af3sa43","country_code":"IR","type":"education","lineage":["https://openalex.org/I170013655"]}],"countries":["IR"],"is_corresponding":true,"raw_author_name":"Siamak Khalili","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Isfahan University of Technology, Isfahan, Iran"],"raw_orcid":"https://orcid.org/0000-0001-9511-3232","affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Isfahan University of Technology, Isfahan, Iran","institution_ids":["https://openalex.org/I170013655"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5048944575","display_name":"Ehsan Adib","orcid":"https://orcid.org/0000-0002-4794-0054"},"institutions":[{"id":"https://openalex.org/I170013655","display_name":"Isfahan University of Technology","ror":"https://ror.org/00af3sa43","country_code":"IR","type":"education","lineage":["https://openalex.org/I170013655"]}],"countries":["IR"],"is_corresponding":false,"raw_author_name":"Ehsan Adib","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Isfahan University of Technology, Isfahan, Iran"],"raw_orcid":"https://orcid.org/0000-0002-4794-0054","affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Isfahan University of Technology, Isfahan, Iran","institution_ids":["https://openalex.org/I170013655"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5083043422","display_name":"Mohsen Packnezhad","orcid":"https://orcid.org/0000-0003-3648-9074"},"institutions":[{"id":"https://openalex.org/I170013655","display_name":"Isfahan University of Technology","ror":"https://ror.org/00af3sa43","country_code":"IR","type":"education","lineage":["https://openalex.org/I170013655"]}],"countries":["IR"],"is_corresponding":false,"raw_author_name":"Mohsen Packnezhad","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Isfahan University of Technology, Isfahan, Iran"],"raw_orcid":"https://orcid.org/0000-0003-3648-9074","affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Isfahan University of Technology, Isfahan, Iran","institution_ids":["https://openalex.org/I170013655"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5058519950","display_name":"Hosein Farzanehfard","orcid":"https://orcid.org/0000-0002-8232-0248"},"institutions":[{"id":"https://openalex.org/I170013655","display_name":"Isfahan University of Technology","ror":"https://ror.org/00af3sa43","country_code":"IR","type":"education","lineage":["https://openalex.org/I170013655"]}],"countries":["IR"],"is_corresponding":false,"raw_author_name":"Hosein Farzanehfard","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Isfahan University of Technology, Isfahan, Iran"],"raw_orcid":"https://orcid.org/0000-0002-8232-0248","affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Isfahan University of Technology, Isfahan, Iran","institution_ids":["https://openalex.org/I170013655"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5008269852","display_name":"Patrick Wheeler","orcid":"https://orcid.org/0000-0003-0307-581X"},"institutions":[{"id":"https://openalex.org/I142263535","display_name":"University of Nottingham","ror":"https://ror.org/01ee9ar58","country_code":"GB","type":"education","lineage":["https://openalex.org/I142263535"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Patrick Wheeler","raw_affiliation_strings":["Power Electronics, Machines and Control Group, Global Director of the University of Nottingham&#x2019;s Institute of Aerospace Technology, University of Nottingham, Nottingham, U.K"],"raw_orcid":"https://orcid.org/0000-0003-0307-581X","affiliations":[{"raw_affiliation_string":"Power Electronics, Machines and Control Group, Global Director of the University of Nottingham&#x2019;s Institute of Aerospace Technology, University of Nottingham, Nottingham, U.K","institution_ids":["https://openalex.org/I142263535"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5040317737"],"corresponding_institution_ids":["https://openalex.org/I170013655"],"apc_list":null,"apc_paid":null,"fwci":3.9187,"has_fulltext":false,"cited_by_count":6,"citation_normalized_percentile":{"value":0.93191341,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":97,"max":99},"biblio":{"volume":"72","issue":"9","first_page":"9061","last_page":"9070"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9948999881744385,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9948999881744385,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12898","display_name":"Induction Heating and Inverter Technology","score":0.9926999807357788,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.986299991607666,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/charge-pump","display_name":"Charge pump","score":0.5535722374916077},{"id":"https://openalex.org/keywords/stress","display_name":"Stress (linguistics)","score":0.5428026914596558},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.5253664255142212},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.5186533331871033},{"id":"https://openalex.org/keywords/forward-converter","display_name":"Forward converter","score":0.46453720331192017},{"id":"https://openalex.org/keywords/switched-capacitor","display_name":"Switched capacitor","score":0.41954392194747925},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.37519729137420654},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.36206912994384766},{"id":"https://openalex.org/keywords/capacitor","display_name":"Capacitor","score":0.258250892162323},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.23330029845237732},{"id":"https://openalex.org/keywords/boost-converter","display_name":"Boost converter","score":0.22920867800712585}],"concepts":[{"id":"https://openalex.org/C114825011","wikidata":"https://www.wikidata.org/wiki/Q440704","display_name":"Charge pump","level":4,"score":0.5535722374916077},{"id":"https://openalex.org/C21036866","wikidata":"https://www.wikidata.org/wiki/Q181767","display_name":"Stress (linguistics)","level":2,"score":0.5428026914596558},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5253664255142212},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5186533331871033},{"id":"https://openalex.org/C55118286","wikidata":"https://www.wikidata.org/wiki/Q634739","display_name":"Forward converter","level":4,"score":0.46453720331192017},{"id":"https://openalex.org/C103357873","wikidata":"https://www.wikidata.org/wiki/Q572656","display_name":"Switched capacitor","level":4,"score":0.41954392194747925},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.37519729137420654},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.36206912994384766},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.258250892162323},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.23330029845237732},{"id":"https://openalex.org/C78336795","wikidata":"https://www.wikidata.org/wiki/Q760134","display_name":"Boost converter","level":3,"score":0.22920867800712585},{"id":"https://openalex.org/C138885662","wikidata":"https://www.wikidata.org/wiki/Q5891","display_name":"Philosophy","level":0,"score":0.0},{"id":"https://openalex.org/C41895202","wikidata":"https://www.wikidata.org/wiki/Q8162","display_name":"Linguistics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tie.2025.3544228","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2025.3544228","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8600000143051147,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":26,"referenced_works":["https://openalex.org/W2155757149","https://openalex.org/W2464095160","https://openalex.org/W2467134388","https://openalex.org/W2562293332","https://openalex.org/W2593065393","https://openalex.org/W2740041315","https://openalex.org/W2746265495","https://openalex.org/W2777288816","https://openalex.org/W2891717720","https://openalex.org/W2989290499","https://openalex.org/W2996659295","https://openalex.org/W3002448158","https://openalex.org/W3005089847","https://openalex.org/W3017138198","https://openalex.org/W3024355900","https://openalex.org/W3034783394","https://openalex.org/W3119264650","https://openalex.org/W3158143577","https://openalex.org/W3161072482","https://openalex.org/W3161221867","https://openalex.org/W4206523132","https://openalex.org/W4285295364","https://openalex.org/W4312219148","https://openalex.org/W4320920364","https://openalex.org/W4362513527","https://openalex.org/W4399768572"],"related_works":["https://openalex.org/W647588539","https://openalex.org/W2035725872","https://openalex.org/W2075733807","https://openalex.org/W589939256","https://openalex.org/W2547490583","https://openalex.org/W2129218324","https://openalex.org/W1590748692","https://openalex.org/W2260503336","https://openalex.org/W2138243092","https://openalex.org/W4391382458"],"abstract_inverted_index":{"A":[0,42,148],"soft-switched":[1],"nonisolated":[2],"dc\u2013dc":[3],"high":[4,25,54],"step-up":[5],"converter":[6,116,131,146,156,204],"with":[7,69,103,164],"a":[8,159,175,190],"single":[9],"switch":[10,102],"is":[11,61,88,132,151,182,199],"proposed":[12,85,130,195],"in":[13,20,90],"this":[14],"article,":[15],"which":[16,87,134],"can":[17],"be":[18],"applied":[19],"photovoltaic":[21],"systems.":[22],"To":[23],"achieve":[24],"voltage":[26,32,105,167,178],"gain":[27],"and":[28,36,57,107,119,143,158,174,196],"reduce":[29],"the":[30,48,65,70,84,96,115,125,129,136,145,155,186,194,203],"components":[31],"stress,":[33],"coupled":[34],"inductors":[35],"switched":[37],"capacitor":[38],"techniques":[39],"are":[40],"integrated.":[41],"suitable":[43],"lossless":[44,49,76,110],"snubber":[45,50,77,111],"circuit":[46,78,122],"overcoming":[47],"challenges":[51],"such":[52],"as":[53],"component":[55,93],"count":[56,94],"freewheeling":[58],"conduction":[59],"loss":[60],"employed":[62],"to":[63,83,114,153,171,184,201],"alleviate":[64],"switching":[66],"losses":[67],"along":[68],"diodes":[71,82],"reverse":[72],"recovery":[73],"problems.":[74],"The":[75],"adds":[79],"only":[80,100],"two":[81],"structure":[86],"optimum":[89],"terms":[91],"of":[92,128,169,179],"among":[95],"soft-switching":[97],"circuits.":[98],"Using":[99],"one":[101],"reduced":[104,120],"stress":[106],"simple":[108],"passive":[109],"has":[112],"contributed":[113],"efficiency":[117],"improvement":[118],"control":[121],"complexity.":[123],"Furthermore,":[124],"input":[126,166],"current":[127],"continuous,":[133],"facilitates":[135],"maximum":[137],"power":[138],"point":[139],"tracking":[140],"(MPPT)":[141],"realization":[142],"enhances":[144],"performance.":[147],"complete":[149],"analysis":[150],"provided":[152],"verify":[154,185],"operation,":[157],"200":[160,180],"W":[161],"laboratory":[162],"prototype":[163],"an":[165],"range":[168],"20":[170],"30":[172],"V":[173],"fixed":[176],"output":[177],"V,":[181],"implemented":[183],"theoretical":[187],"analysis.":[188],"Also,":[189],"comprehensive":[191],"comparison":[192],"between":[193],"comparative":[197],"topologies":[198],"described":[200],"illustrate":[202],"superiority.":[205]},"counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2025,"cited_by_count":4}],"updated_date":"2026-03-27T05:58:40.876381","created_date":"2025-10-10T00:00:00"}
