{"id":"https://openalex.org/W4408399784","doi":"https://doi.org/10.1109/tie.2025.3544195","title":"Systematical Investigation of Transient Response and Fault Clearing Angle Estimation for Delay-Based PLL Inverters During Grid Fault","display_name":"Systematical Investigation of Transient Response and Fault Clearing Angle Estimation for Delay-Based PLL Inverters During Grid Fault","publication_year":2025,"publication_date":"2025-03-13","ids":{"openalex":"https://openalex.org/W4408399784","doi":"https://doi.org/10.1109/tie.2025.3544195"},"language":"en","primary_location":{"id":"doi:10.1109/tie.2025.3544195","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2025.3544195","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100543137","display_name":"Yantao Zhu","orcid":null},"institutions":[{"id":"https://openalex.org/I9842412","display_name":"Nanjing University of Aeronautics and Astronautics","ror":"https://ror.org/01scyh794","country_code":"CN","type":"education","lineage":["https://openalex.org/I9842412"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yantao Zhu","raw_affiliation_strings":["Center for More-Electrical-Aircraft Power System, College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China"],"raw_orcid":"https://orcid.org/0009-0008-3590-7557","affiliations":[{"raw_affiliation_string":"Center for More-Electrical-Aircraft Power System, College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China","institution_ids":["https://openalex.org/I9842412"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5051895369","display_name":"Tianzhi Fang","orcid":"https://orcid.org/0000-0002-4767-3814"},"institutions":[{"id":"https://openalex.org/I9842412","display_name":"Nanjing University of Aeronautics and Astronautics","ror":"https://ror.org/01scyh794","country_code":"CN","type":"education","lineage":["https://openalex.org/I9842412"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Tianzhi Fang","raw_affiliation_strings":["Center for More-Electrical-Aircraft Power System, College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China"],"raw_orcid":"https://orcid.org/0000-0002-4767-3814","affiliations":[{"raw_affiliation_string":"Center for More-Electrical-Aircraft Power System, College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China","institution_ids":["https://openalex.org/I9842412"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5028116670","display_name":"Zhiheng Lin","orcid":"https://orcid.org/0000-0001-6777-1043"},"institutions":[{"id":"https://openalex.org/I154425047","display_name":"University of Alberta","ror":"https://ror.org/0160cpw27","country_code":"CA","type":"education","lineage":["https://openalex.org/I154425047"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Zhiheng Lin","raw_affiliation_strings":["Department of Electrical and Computer Engineering, University of Alberta, Edmonton, Alberta, Canada"],"raw_orcid":"https://orcid.org/0000-0001-6777-1043","affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Alberta, Edmonton, Alberta, Canada","institution_ids":["https://openalex.org/I154425047"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5114155674","display_name":"Jiayue Lyu","orcid":null},"institutions":[{"id":"https://openalex.org/I9842412","display_name":"Nanjing University of Aeronautics and Astronautics","ror":"https://ror.org/01scyh794","country_code":"CN","type":"education","lineage":["https://openalex.org/I9842412"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jiayue Lyu","raw_affiliation_strings":["Center for More-Electrical-Aircraft Power System, College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China"],"raw_orcid":"https://orcid.org/0009-0000-1178-5681","affiliations":[{"raw_affiliation_string":"Center for More-Electrical-Aircraft Power System, College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China","institution_ids":["https://openalex.org/I9842412"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5109783643","display_name":"Yaohan Xia","orcid":null},"institutions":[{"id":"https://openalex.org/I9842412","display_name":"Nanjing University of Aeronautics and Astronautics","ror":"https://ror.org/01scyh794","country_code":"CN","type":"education","lineage":["https://openalex.org/I9842412"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yaohan Xia","raw_affiliation_strings":["Center for More-Electrical-Aircraft Power System, College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China"],"raw_orcid":"https://orcid.org/0009-0002-0264-4291","affiliations":[{"raw_affiliation_string":"Center for More-Electrical-Aircraft Power System, College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China","institution_ids":["https://openalex.org/I9842412"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.7779,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.67877106,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":95},"biblio":{"volume":"72","issue":"10","first_page":"10061","last_page":"10070"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9965000152587891,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9965000152587891,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9947999715805054,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":0.9787999987602234,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/phase-locked-loop","display_name":"Phase-locked loop","score":0.7970210313796997},{"id":"https://openalex.org/keywords/transient","display_name":"Transient (computer programming)","score":0.7009885311126709},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.6916655898094177},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.6043250560760498},{"id":"https://openalex.org/keywords/transient-response","display_name":"Transient response","score":0.5032095313072205},{"id":"https://openalex.org/keywords/transient-analysis","display_name":"Transient analysis","score":0.4819902777671814},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.461905300617218},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.44580426812171936},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.38333559036254883},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.30467814207077026},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.14007127285003662},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.10614961385726929},{"id":"https://openalex.org/keywords/geology","display_name":"Geology","score":0.08898073434829712}],"concepts":[{"id":"https://openalex.org/C12707504","wikidata":"https://www.wikidata.org/wiki/Q52637","display_name":"Phase-locked loop","level":3,"score":0.7970210313796997},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.7009885311126709},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6916655898094177},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6043250560760498},{"id":"https://openalex.org/C85761212","wikidata":"https://www.wikidata.org/wiki/Q1974593","display_name":"Transient response","level":2,"score":0.5032095313072205},{"id":"https://openalex.org/C2989121073","wikidata":"https://www.wikidata.org/wiki/Q1309019","display_name":"Transient analysis","level":3,"score":0.4819902777671814},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.461905300617218},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.44580426812171936},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.38333559036254883},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.30467814207077026},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.14007127285003662},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.10614961385726929},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.08898073434829712},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C134652429","wikidata":"https://www.wikidata.org/wiki/Q1052698","display_name":"Jitter","level":2,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tie.2025.3544195","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2025.3544195","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Climate action","id":"https://metadata.un.org/sdg/13","score":0.75}],"awards":[{"id":"https://openalex.org/G1735929786","display_name":null,"funder_award_id":"52077102","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"}],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":24,"referenced_works":["https://openalex.org/W1509227760","https://openalex.org/W1981829062","https://openalex.org/W2605543710","https://openalex.org/W2610528666","https://openalex.org/W2612483862","https://openalex.org/W2734336003","https://openalex.org/W2791193733","https://openalex.org/W2899329342","https://openalex.org/W2911026196","https://openalex.org/W2914659810","https://openalex.org/W2970988154","https://openalex.org/W2989648379","https://openalex.org/W3113996206","https://openalex.org/W3212634201","https://openalex.org/W4226325984","https://openalex.org/W4235743092","https://openalex.org/W4312408907","https://openalex.org/W4312739724","https://openalex.org/W4319866397","https://openalex.org/W4362714834","https://openalex.org/W4385656501","https://openalex.org/W4386590704","https://openalex.org/W4392939853","https://openalex.org/W4399057801"],"related_works":["https://openalex.org/W2758798772","https://openalex.org/W2081338125","https://openalex.org/W4406350055","https://openalex.org/W4239924455","https://openalex.org/W2001630809","https://openalex.org/W777979701","https://openalex.org/W2014796125","https://openalex.org/W4244925124","https://openalex.org/W2669128877","https://openalex.org/W1985471711"],"abstract_inverted_index":{"For":[0],"grid-following":[1,69],"inverters,":[2,70],"the":[3,16,23,29,51,65,72,77,84,90,105,131,138],"phase-locked":[4],"loop":[5],"(PLL)":[6],"plays":[7],"a":[8,45,61,163],"critical":[9],"role":[10],"in":[11],"ensuring":[12],"transient":[13,31,53,66,147],"stability.":[14],"From":[15],"perspective":[17],"of":[18,50,64,68,107],"safe":[19],"and":[20,35,47,155,170],"robust":[21],"operation,":[22],"inverter":[24],"must":[25],"remain":[26],"stable":[27],"throughout":[28],"entire":[30,52],"process,":[32],"including":[33,104],"during":[34,55,149,172],"after":[36,113],"grid":[37],"fault.":[38],"However,":[39],"previous":[40],"research":[41],"has":[42],"not":[43,101],"provided":[44],"systematic":[46],"comprehensive":[48],"analysis":[49,88],"response":[54],"fault":[56,114,132,150,173],"events.":[57],"This":[58],"article":[59],"offers":[60],"detailed":[62],"study":[63],"stability":[67,148],"combining":[71],"equal":[73],"area":[74],"criterion":[75],"with":[76],"phase":[78],"portraits":[79],"method":[80,128,154],"that":[81,111],"accounts":[82],"for":[83,129],"frequency-dependent":[85],"impedance.":[86],"The":[87,152],"classifies":[89],"system's":[91],"dynamic":[92],"behavior":[93],"into":[94],"five":[95],"distinct":[96],"cases,":[97],"revealing":[98],"new":[99],"phenomena":[100],"previously":[102],"explored,":[103],"identification":[106],"an":[108,126],"unstable":[109],"region":[110],"emerges":[112],"recovery,":[115],"which":[116],"can":[117],"lead":[118],"to":[119,142],"system":[120],"instability.":[121],"To":[122],"mitigate":[123],"this":[124],"issue,":[125],"advanced":[127],"estimating":[130],"clearing":[133],"angle":[134],"is":[135],"proposed,":[136],"extending":[137],"traditional":[139],"single-interval":[140],"approach":[141],"multiple":[143],"intervals,":[144],"thereby":[145],"enhancing":[146],"recovery.":[151],"proposed":[153],"findings":[156],"are":[157],"validated":[158],"through":[159],"experimental":[160],"tests":[161],"on":[162],"single-phase":[164],"grid-connected":[165],"inverter,":[166],"confirming":[167],"their":[168],"effectiveness":[169],"relevance":[171],"processes.":[174]},"counts_by_year":[{"year":2025,"cited_by_count":1}],"updated_date":"2025-12-28T23:10:05.387466","created_date":"2025-10-10T00:00:00"}
