{"id":"https://openalex.org/W4214862803","doi":"https://doi.org/10.1109/tie.2022.3153810","title":"A Novel Detection and Localization Approach of Open-Circuit Switch Fault for the Grid-Connected Modular Multilevel Converter","display_name":"A Novel Detection and Localization Approach of Open-Circuit Switch Fault for the Grid-Connected Modular Multilevel Converter","publication_year":2022,"publication_date":"2022-03-01","ids":{"openalex":"https://openalex.org/W4214862803","doi":"https://doi.org/10.1109/tie.2022.3153810"},"language":"en","primary_location":{"id":"doi:10.1109/tie.2022.3153810","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2022.3153810","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://vbn.aau.dk/ws/files/760304475/A_Novel_Detection_and_Localization_Approach_of_Open_Circuit_Switch_Fault_for_the_Grid_Connected_Modular_Multilevel_Converter.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5013366563","display_name":"Yu Jin","orcid":"https://orcid.org/0000-0003-3861-5089"},"institutions":[{"id":"https://openalex.org/I204983213","display_name":"Harbin Institute of Technology","ror":"https://ror.org/01yqg2h08","country_code":"CN","type":"education","lineage":["https://openalex.org/I204983213"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yu Jin","raw_affiliation_strings":["Department of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin, China"],"raw_orcid":"https://orcid.org/0000-0003-3861-5089","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin, China","institution_ids":["https://openalex.org/I204983213"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5082921193","display_name":"Qian Xiao","orcid":"https://orcid.org/0000-0002-4986-4438"},"institutions":[{"id":"https://openalex.org/I162868743","display_name":"Tianjin University","ror":"https://ror.org/012tb2g32","country_code":"CN","type":"education","lineage":["https://openalex.org/I162868743"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Qian Xiao","raw_affiliation_strings":["Key Laboratory of Smart Grid of Ministry of Education and the Key Laboratory of Smart Energy and Information Technology of Tianjin Municipality, Tianjin University, Tianjin, China"],"raw_orcid":"https://orcid.org/0000-0002-4986-4438","affiliations":[{"raw_affiliation_string":"Key Laboratory of Smart Grid of Ministry of Education and the Key Laboratory of Smart Energy and Information Technology of Tianjin Municipality, Tianjin University, Tianjin, China","institution_ids":["https://openalex.org/I162868743"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5053616362","display_name":"Hongjie Jia","orcid":"https://orcid.org/0000-0003-2907-2895"},"institutions":[{"id":"https://openalex.org/I162868743","display_name":"Tianjin University","ror":"https://ror.org/012tb2g32","country_code":"CN","type":"education","lineage":["https://openalex.org/I162868743"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Hongjie Jia","raw_affiliation_strings":["Key Laboratory of Smart Grid of Ministry of Education and the Key Laboratory of Smart Energy and Information Technology of Tianjin Municipality, Tianjin University, Tianjin, China"],"raw_orcid":"https://orcid.org/0000-0003-2907-2895","affiliations":[{"raw_affiliation_string":"Key Laboratory of Smart Grid of Ministry of Education and the Key Laboratory of Smart Energy and Information Technology of Tianjin Municipality, Tianjin University, Tianjin, China","institution_ids":["https://openalex.org/I162868743"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5103269914","display_name":"Yanchao Ji","orcid":"https://orcid.org/0000-0002-4668-6613"},"institutions":[{"id":"https://openalex.org/I204983213","display_name":"Harbin Institute of Technology","ror":"https://ror.org/01yqg2h08","country_code":"CN","type":"education","lineage":["https://openalex.org/I204983213"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yanchao Ji","raw_affiliation_strings":["Department of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin, China","institution_ids":["https://openalex.org/I204983213"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5078176748","display_name":"Tomislav Dragi\u010devi\u0107","orcid":"https://orcid.org/0000-0003-4755-2024"},"institutions":[{"id":"https://openalex.org/I96673099","display_name":"Technical University of Denmark","ror":"https://ror.org/04qtj9h94","country_code":"DK","type":"education","lineage":["https://openalex.org/I96673099"]}],"countries":["DK"],"is_corresponding":false,"raw_author_name":"Tomislav Dragicevic","raw_affiliation_strings":["Center of Electric Power and Energy, Technical University of Denmark, Kongens Lyngby, Denmark"],"raw_orcid":"https://orcid.org/0000-0003-4755-2024","affiliations":[{"raw_affiliation_string":"Center of Electric Power and Energy, Technical University of Denmark, Kongens Lyngby, Denmark","institution_ids":["https://openalex.org/I96673099"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5019644280","display_name":"Remus Teodorescu","orcid":"https://orcid.org/0000-0002-2617-7168"},"institutions":[{"id":"https://openalex.org/I891191580","display_name":"Aalborg University","ror":"https://ror.org/04m5j1k67","country_code":"DK","type":"education","lineage":["https://openalex.org/I891191580"]}],"countries":["DK"],"is_corresponding":false,"raw_author_name":"Remus Teodorescu","raw_affiliation_strings":["Department of Energy Technology, Aalborg University, Aalborg, Denmark"],"raw_orcid":"https://orcid.org/0000-0002-2617-7168","affiliations":[{"raw_affiliation_string":"Department of Energy Technology, Aalborg University, Aalborg, Denmark","institution_ids":["https://openalex.org/I891191580"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5039395705","display_name":"Frede Blaabjerg","orcid":"https://orcid.org/0000-0001-8311-7412"},"institutions":[{"id":"https://openalex.org/I891191580","display_name":"Aalborg University","ror":"https://ror.org/04m5j1k67","country_code":"DK","type":"education","lineage":["https://openalex.org/I891191580"]}],"countries":["DK"],"is_corresponding":false,"raw_author_name":"Frede Blaabjerg","raw_affiliation_strings":["Department of Energy Technology, Aalborg University, Aalborg, Denmark"],"raw_orcid":"https://orcid.org/0000-0001-8311-7412","affiliations":[{"raw_affiliation_string":"Department of Energy Technology, Aalborg University, Aalborg, Denmark","institution_ids":["https://openalex.org/I891191580"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":4,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":5.7426,"has_fulltext":true,"cited_by_count":70,"citation_normalized_percentile":{"value":0.96977267,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":98,"max":100},"biblio":{"volume":"70","issue":"1","first_page":"112","last_page":"124"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.9930999875068665,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.992900013923645,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/modular-design","display_name":"Modular design","score":0.7723202705383301},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.5823528170585632},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5368725657463074},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.5226454734802246},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.5158973932266235},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.45691874623298645},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.396855890750885},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3102887272834778},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.07438161969184875}],"concepts":[{"id":"https://openalex.org/C101468663","wikidata":"https://www.wikidata.org/wiki/Q1620158","display_name":"Modular design","level":2,"score":0.7723202705383301},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5823528170585632},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5368725657463074},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.5226454734802246},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5158973932266235},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.45691874623298645},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.396855890750885},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3102887272834778},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.07438161969184875},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/tie.2022.3153810","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2022.3153810","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},{"id":"pmh:oai:pure.atira.dk:publications/bffdbdef-108e-4a0b-bfa6-f734a9768784","is_oa":true,"landing_page_url":"https://vbn.aau.dk/da/publications/bffdbdef-108e-4a0b-bfa6-f734a9768784","pdf_url":"https://vbn.aau.dk/ws/files/760304475/A_Novel_Detection_and_Localization_Approach_of_Open_Circuit_Switch_Fault_for_the_Grid_Connected_Modular_Multilevel_Converter.pdf","source":{"id":"https://openalex.org/S4306401731","display_name":"VBN Forskningsportal (Aalborg Universitet)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I891191580","host_organization_name":"Aalborg University","host_organization_lineage":["https://openalex.org/I891191580"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Jin, Y, Xiao, Q, Jia, H, Ji, Y, Dragi\u010devi\u0107, T, Teodorescu, R & Blaabjerg, F 2023, 'A Novel Detection and Localization Approach of Open-Circuit Switch Fault for the Grid-Connected Modular Multilevel Converter', I E E E Transactions on Industrial Electronics, vol. 70, no. 1, 9724129, pp. 112 - 124. https://doi.org/10.1109/TIE.2022.3153810","raw_type":"info:eu-repo/semantics/article"},{"id":"pmh:oai:pure.atira.dk:publications/e32d7e52-41d3-49d0-a8d7-ed8393172d73","is_oa":true,"landing_page_url":"https://orbit.dtu.dk/en/publications/e32d7e52-41d3-49d0-a8d7-ed8393172d73","pdf_url":null,"source":{"id":"https://openalex.org/S4306400705","display_name":"Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I96673099","host_organization_name":"Technical University of Denmark","host_organization_lineage":["https://openalex.org/I96673099"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Jin , Y , Xiao , Q , Jia , H , Ji , Y , Dragicevic , T , Teodorescu , R &amp; Blaabjerg , F 2022 , ' A Novel Detection and Localization Approach of Open-Circuit Switch Fault for the Grid-Connected Modular Multilevel Converter ' , IEEE Transactions on Industrial Electronics , vol. 70 , no. 1 , pp. 112-124 . https://doi.org/10.1109/TIE.2022.3153810","raw_type":"article"}],"best_oa_location":{"id":"pmh:oai:pure.atira.dk:publications/bffdbdef-108e-4a0b-bfa6-f734a9768784","is_oa":true,"landing_page_url":"https://vbn.aau.dk/da/publications/bffdbdef-108e-4a0b-bfa6-f734a9768784","pdf_url":"https://vbn.aau.dk/ws/files/760304475/A_Novel_Detection_and_Localization_Approach_of_Open_Circuit_Switch_Fault_for_the_Grid_Connected_Modular_Multilevel_Converter.pdf","source":{"id":"https://openalex.org/S4306401731","display_name":"VBN Forskningsportal (Aalborg Universitet)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I891191580","host_organization_name":"Aalborg University","host_organization_lineage":["https://openalex.org/I891191580"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Jin, Y, Xiao, Q, Jia, H, Ji, Y, Dragi\u010devi\u0107, T, Teodorescu, R & Blaabjerg, F 2023, 'A Novel Detection and Localization Approach of Open-Circuit Switch Fault for the Grid-Connected Modular Multilevel Converter', I E E E Transactions on Industrial Electronics, vol. 70, no. 1, 9724129, pp. 112 - 124. https://doi.org/10.1109/TIE.2022.3153810","raw_type":"info:eu-repo/semantics/article"},"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G1576455285","display_name":null,"funder_award_id":"T021969","funder_id":"https://openalex.org/F4320334627","funder_display_name":"Engineering and Physical Sciences Research Council"},{"id":"https://openalex.org/G2062492940","display_name":null,"funder_award_id":"52061635103","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G2269071697","display_name":null,"funder_award_id":"52061635103","funder_id":"https://openalex.org/F4320334627","funder_display_name":"Engineering and Physical Sciences Research Council"},{"id":"https://openalex.org/G237320214","display_name":"Multi-energy Control of Cyber-Physical Urban Energy Systems (MC2)","funder_award_id":"EP/T021969/1","funder_id":"https://openalex.org/F4320334627","funder_display_name":"Engineering and Physical Sciences Research Council"},{"id":"https://openalex.org/G2722417226","display_name":null,"funder_award_id":"52107121","funder_id":"https://openalex.org/F4320321543","funder_display_name":"China Postdoctoral Science Foundation"},{"id":"https://openalex.org/G2976905672","display_name":null,"funder_award_id":"EP/T021969/1","funder_id":"https://openalex.org/F4320334627","funder_display_name":"Engineering and Physical Sciences Research Council"},{"id":"https://openalex.org/G5533375901","display_name":null,"funder_award_id":"EP/T021969/1","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G5842815890","display_name":null,"funder_award_id":"2020M680880","funder_id":"https://openalex.org/F4320321543","funder_display_name":"China Postdoctoral Science Foundation"},{"id":"https://openalex.org/G7187598602","display_name":null,"funder_award_id":"52107121","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G7996037212","display_name":null,"funder_award_id":"No. 52107121","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"}],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"},{"id":"https://openalex.org/F4320321543","display_name":"China Postdoctoral Science Foundation","ror":"https://ror.org/0426zh255"},{"id":"https://openalex.org/F4320334627","display_name":"Engineering and Physical Sciences Research Council","ror":"https://ror.org/0439y7842"}],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4214862803.pdf","grobid_xml":"https://content.openalex.org/works/W4214862803.grobid-xml"},"referenced_works_count":29,"referenced_works":["https://openalex.org/W2010969581","https://openalex.org/W2061146253","https://openalex.org/W2129242370","https://openalex.org/W2168306830","https://openalex.org/W2174980551","https://openalex.org/W2215529216","https://openalex.org/W2284778013","https://openalex.org/W2343375316","https://openalex.org/W2566774301","https://openalex.org/W2592429078","https://openalex.org/W2758044484","https://openalex.org/W2768367027","https://openalex.org/W2800143249","https://openalex.org/W2886156789","https://openalex.org/W2892238434","https://openalex.org/W2903369950","https://openalex.org/W2955725153","https://openalex.org/W2964196009","https://openalex.org/W2969336592","https://openalex.org/W2973107558","https://openalex.org/W2991501580","https://openalex.org/W2997280174","https://openalex.org/W2999478524","https://openalex.org/W3004329456","https://openalex.org/W3011926240","https://openalex.org/W3021018218","https://openalex.org/W3030874192","https://openalex.org/W3128123356","https://openalex.org/W3138086999"],"related_works":["https://openalex.org/W2378076731","https://openalex.org/W4286888643","https://openalex.org/W3210795196","https://openalex.org/W2249385795","https://openalex.org/W2088988140","https://openalex.org/W3171015545","https://openalex.org/W2103019253","https://openalex.org/W2951529875","https://openalex.org/W2391453316","https://openalex.org/W4396648495"],"abstract_inverted_index":{"The":[0],"open-circuit":[1,178],"fault":[2,80,119],"detection":[3],"and":[4,40,60,64,104,152,164,175,180],"localization":[5,33],"(FDL)":[6],"technique":[7],"can":[8,81,156,172],"improve":[9],"the":[10,13,19,46,50,53,61,78,91,95,105,109,117,133,140,144,153,169,185],"reliability":[11],"of":[12,143,187],"modular":[14],"multilevel":[15],"converter":[16],"(MMC).":[17],"However,":[18],"conventional":[20],"software-based":[21,42,146],"FDL":[22,43,147],"methods":[23],"usually":[24],"have":[25],"a":[26,31,38,123,138,160],"heavy":[27],"computation":[28,141],"burden":[29,142],"or":[30],"limited":[32],"speed.":[34],"This":[35],"article":[36],"proposes":[37],"simplified":[39],"fast":[41],"approach":[44,148,171],"for":[45],"grid-connected":[47],"MMC.":[48],"First,":[49],"errors":[51,73],"between":[52],"measured":[54],"state":[55],"variables":[56],"(the":[57],"output":[58],"current":[59],"circulating":[62],"current)":[63],"their":[65,75],"estimated":[66],"values":[67],"are":[68,102],"calculated.":[69],"By":[70],"comparing":[71],"these":[72],"with":[74,108],"threshold":[76],"values,":[77],"switch":[79,118],"not":[82],"only":[83],"be":[84,88,157],"detected":[85],"but":[86],"also":[87],"localized":[89,158],"to":[90,131,184],"specific":[92],"arm.":[93],"Then,":[94],"capacitor":[96,111],"voltages":[97],"in":[98,120,159],"this":[99,121],"faulty":[100,154],"arm":[101],"collected,":[103],"submodule":[106],"(SM)":[107],"highest":[110],"voltage":[112,135],"is":[113,129,149,182],"selected.":[114],"To":[115],"confirm":[116],"SM,":[122],"modified":[124],"<italic":[125],"xmlns:mml=\"http://www.w3.org/1998/Math/MathML\"":[126],"xmlns:xlink=\"http://www.w3.org/1999/xlink\">Pauta</i>":[127],"criterion":[128],"presented":[130],"check":[132],"abnormal":[134],"data.":[136],"As":[137],"result,":[139],"proposed":[145,170],"significantly":[150],"reduced,":[151],"SM":[155],"short":[161],"period.":[162],"Simulation":[163],"experimental":[165],"results":[166],"verify":[167],"that":[168],"effectively":[173],"detect":[174],"localize":[176],"different":[177],"faults,":[179],"it":[181],"immune":[183],"step":[186],"power":[188],"references.":[189]},"counts_by_year":[{"year":2026,"cited_by_count":5},{"year":2025,"cited_by_count":24},{"year":2024,"cited_by_count":15},{"year":2023,"cited_by_count":19},{"year":2022,"cited_by_count":7}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
