{"id":"https://openalex.org/W3197551598","doi":"https://doi.org/10.1109/tie.2021.3106012","title":"A Generalized Open-Circuit Fault-Tolerant Control Strategy for FOC and DTC of Five-Phase Fault-Tolerant Permanent-Magnet Motor","display_name":"A Generalized Open-Circuit Fault-Tolerant Control Strategy for FOC and DTC of Five-Phase Fault-Tolerant Permanent-Magnet Motor","publication_year":2021,"publication_date":"2021-08-25","ids":{"openalex":"https://openalex.org/W3197551598","doi":"https://doi.org/10.1109/tie.2021.3106012","mag":"3197551598"},"language":"en","primary_location":{"id":"doi:10.1109/tie.2021.3106012","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2021.3106012","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100425592","display_name":"Li Zhang","orcid":"https://orcid.org/0000-0002-5308-8988"},"institutions":[{"id":"https://openalex.org/I115592961","display_name":"Jiangsu University","ror":"https://ror.org/03jc41j30","country_code":"CN","type":"education","lineage":["https://openalex.org/I115592961"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Li Zhang","raw_affiliation_strings":["School of Electrical and Information Engineering, Jiangsu University, Zhenjiang, China"],"affiliations":[{"raw_affiliation_string":"School of Electrical and Information Engineering, Jiangsu University, Zhenjiang, China","institution_ids":["https://openalex.org/I115592961"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5047643306","display_name":"Xiaoyong Zhu","orcid":"https://orcid.org/0000-0001-6333-3329"},"institutions":[{"id":"https://openalex.org/I115592961","display_name":"Jiangsu University","ror":"https://ror.org/03jc41j30","country_code":"CN","type":"education","lineage":["https://openalex.org/I115592961"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xiaoyong Zhu","raw_affiliation_strings":["School of Electrical and Information Engineering, Jiangsu University, Zhenjiang, China"],"affiliations":[{"raw_affiliation_string":"School of Electrical and Information Engineering, Jiangsu University, Zhenjiang, China","institution_ids":["https://openalex.org/I115592961"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100425541","display_name":"Ronghua Cui","orcid":"https://orcid.org/0000-0002-3151-5205"},"institutions":[{"id":"https://openalex.org/I78978612","display_name":"Yangzhou University","ror":"https://ror.org/03tqb8s11","country_code":"CN","type":"education","lineage":["https://openalex.org/I78978612"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Ronghua Cui","raw_affiliation_strings":["School of Electrical, Energy and Power Engineering, Yangzhou University, Yangzhou, China"],"affiliations":[{"raw_affiliation_string":"School of Electrical, Energy and Power Engineering, Yangzhou University, Yangzhou, China","institution_ids":["https://openalex.org/I78978612"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5001506788","display_name":"Sai Han","orcid":null},"institutions":[{"id":"https://openalex.org/I115592961","display_name":"Jiangsu University","ror":"https://ror.org/03jc41j30","country_code":"CN","type":"education","lineage":["https://openalex.org/I115592961"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Sai Han","raw_affiliation_strings":["School of Electrical and Information Engineering, Jiangsu University, Zhenjiang, China"],"affiliations":[{"raw_affiliation_string":"School of Electrical and Information Engineering, Jiangsu University, Zhenjiang, China","institution_ids":["https://openalex.org/I115592961"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5100425592"],"corresponding_institution_ids":["https://openalex.org/I115592961"],"apc_list":null,"apc_paid":null,"fwci":3.8103,"has_fulltext":false,"cited_by_count":47,"citation_normalized_percentile":{"value":0.9403404,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":97,"max":99},"biblio":{"volume":"69","issue":"8","first_page":"7825","last_page":"7836"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10504","display_name":"Sensorless Control of Electric Motors","score":0.9988999962806702,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fault-tolerance","display_name":"Fault tolerance","score":0.83612060546875},{"id":"https://openalex.org/keywords/control-reconfiguration","display_name":"Control reconfiguration","score":0.7659578323364258},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.759068489074707},{"id":"https://openalex.org/keywords/torque","display_name":"Torque","score":0.5537647604942322},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.54749596118927},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.4923356771469116},{"id":"https://openalex.org/keywords/direct-torque-control","display_name":"Direct torque control","score":0.4596500098705292},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.44135862588882446},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4254003167152405},{"id":"https://openalex.org/keywords/vector-control","display_name":"Vector control","score":0.4121331572532654},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.38929620385169983},{"id":"https://openalex.org/keywords/induction-motor","display_name":"Induction motor","score":0.3034511208534241},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.2315775752067566},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.11268863081932068},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.07755234837532043},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.05525374412536621}],"concepts":[{"id":"https://openalex.org/C63540848","wikidata":"https://www.wikidata.org/wiki/Q3140932","display_name":"Fault tolerance","level":2,"score":0.83612060546875},{"id":"https://openalex.org/C119701452","wikidata":"https://www.wikidata.org/wiki/Q5165881","display_name":"Control reconfiguration","level":2,"score":0.7659578323364258},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.759068489074707},{"id":"https://openalex.org/C144171764","wikidata":"https://www.wikidata.org/wiki/Q48103","display_name":"Torque","level":2,"score":0.5537647604942322},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.54749596118927},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4923356771469116},{"id":"https://openalex.org/C109871850","wikidata":"https://www.wikidata.org/wiki/Q1227571","display_name":"Direct torque control","level":4,"score":0.4596500098705292},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.44135862588882446},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4254003167152405},{"id":"https://openalex.org/C152060993","wikidata":"https://www.wikidata.org/wiki/Q1759392","display_name":"Vector control","level":4,"score":0.4121331572532654},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.38929620385169983},{"id":"https://openalex.org/C80962145","wikidata":"https://www.wikidata.org/wiki/Q207450","display_name":"Induction motor","level":3,"score":0.3034511208534241},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.2315775752067566},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.11268863081932068},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.07755234837532043},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.05525374412536621},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tie.2021.3106012","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2021.3106012","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.6299999952316284}],"awards":[{"id":"https://openalex.org/G1298773689","display_name":null,"funder_award_id":"51937006","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G3054207035","display_name":null,"funder_award_id":"BK20190850","funder_id":"https://openalex.org/F4320322769","funder_display_name":"Natural Science Foundation of Jiangsu Province"},{"id":"https://openalex.org/G3228015892","display_name":null,"funder_award_id":"51907079","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G6385522815","display_name":null,"funder_award_id":"2019TQ0124","funder_id":"https://openalex.org/F4320321543","funder_display_name":"China Postdoctoral Science Foundation"},{"id":"https://openalex.org/G891429326","display_name":null,"funder_award_id":"2019M661748","funder_id":"https://openalex.org/F4320321543","funder_display_name":"China Postdoctoral Science Foundation"}],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"},{"id":"https://openalex.org/F4320321543","display_name":"China Postdoctoral Science Foundation","ror":"https://ror.org/0426zh255"},{"id":"https://openalex.org/F4320322769","display_name":"Natural Science Foundation of Jiangsu Province","ror":"https://ror.org/01h0zpd94"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":28,"referenced_works":["https://openalex.org/W1549747831","https://openalex.org/W2027655811","https://openalex.org/W2057518416","https://openalex.org/W2057946096","https://openalex.org/W2083378724","https://openalex.org/W2101487263","https://openalex.org/W2111225396","https://openalex.org/W2275451103","https://openalex.org/W2303244400","https://openalex.org/W2509345571","https://openalex.org/W2516656687","https://openalex.org/W2521547875","https://openalex.org/W2522261006","https://openalex.org/W2523470359","https://openalex.org/W2622508985","https://openalex.org/W2735538861","https://openalex.org/W2747936290","https://openalex.org/W2761582691","https://openalex.org/W2797580837","https://openalex.org/W2810420451","https://openalex.org/W2890544142","https://openalex.org/W2911545606","https://openalex.org/W2912948894","https://openalex.org/W2974583949","https://openalex.org/W2977359099","https://openalex.org/W2984677819","https://openalex.org/W2991252079","https://openalex.org/W3020690320"],"related_works":["https://openalex.org/W2003389362","https://openalex.org/W2604101721","https://openalex.org/W2134656663","https://openalex.org/W1976520621","https://openalex.org/W2130594209","https://openalex.org/W2351481361","https://openalex.org/W4247153582","https://openalex.org/W2121571705","https://openalex.org/W1546878080","https://openalex.org/W4321063092"],"abstract_inverted_index":{"A":[0],"generalized":[1],"fault-tolerant":[2,18,76,82],"control":[3,9,14,41,105,124,128],"(FTC)":[4],"strategy":[5,129],"for":[6,154],"the":[7,55,58,68,89,119,122,133,165],"field-oriented":[8],"(FOC)":[10],"and":[11,43,49,85,96,136,141,150],"direct":[12],"torque":[13,134],"(DTC)":[15],"of":[16,57,121],"five-phase":[17],"permanent":[19],"magnet":[20],"(FPFTPM)":[21],"motors":[22],"under":[23,109,139],"various":[24,110],"open-circuit":[25,111],"faults":[26,112],"is":[27,71,100],"presented":[28],"in":[29],"this":[30,63],"article.":[31],"Most":[32],"previous":[33],"studies":[34],"regarding":[35],"FTC":[36],"target":[37],"a":[38,65,103,155],"specific":[39],"primary":[40,123],"algorithm":[42],"involve":[44],"different":[45],"reduced-order":[46],"transformation":[47,91],"matrices":[48],"additional":[50,97],"current":[51],"controllers,":[52],"which":[53,78],"increase":[54],"complexity":[56],"entire":[59],"drive":[60,106],"system.":[61],"In":[62],"study,":[64],"solution":[66],"to":[67,116,147,163],"aforementioned":[69],"problems":[70],"devised":[72],"by":[73],"developing":[74],"optimal":[75],"voltages,":[77],"are":[79,161],"derived":[80],"from":[81],"mechanism":[83],"analysis":[84],"steady-healthy":[86],"design.":[87],"Because":[88],"coordinate":[90],"need":[92],"not":[93,101,130],"be":[94,114],"changed":[95],"voltage":[98],"compensation":[99],"required,":[102],"minimal":[104],"system":[107],"reconfiguration":[108],"can":[113],"achieved":[115],"avoid":[117],"accommodating":[118],"change":[120],"algorithm.":[125],"The":[126],"proposed":[127,166],"only":[131],"improves":[132],"performance":[135],"dynamic":[137],"response":[138],"healthy":[140],"fault":[142],"conditions,":[143],"but":[144],"also":[145],"adapts":[146],"both":[148],"FOC":[149],"DTC.":[151],"Experimental":[152],"results":[153],"2":[156],"kW":[157],"FPFTPM":[158],"motor":[159],"prototype":[160],"provided":[162],"evaluate":[164],"strategy.":[167]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":8},{"year":2024,"cited_by_count":12},{"year":2023,"cited_by_count":15},{"year":2022,"cited_by_count":11}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
