{"id":"https://openalex.org/W3172129720","doi":"https://doi.org/10.1109/tie.2021.3084165","title":"Air-Core-Transformer-Based Solid-State Fault-Current Limiter for Bidirectional HVdc Systems","display_name":"Air-Core-Transformer-Based Solid-State Fault-Current Limiter for Bidirectional HVdc Systems","publication_year":2021,"publication_date":"2021-06-03","ids":{"openalex":"https://openalex.org/W3172129720","doi":"https://doi.org/10.1109/tie.2021.3084165","mag":"3172129720"},"language":"en","primary_location":{"id":"doi:10.1109/tie.2021.3084165","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2021.3084165","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5091628886","display_name":"Ming Yang","orcid":"https://orcid.org/0000-0001-9907-0364"},"institutions":[{"id":"https://openalex.org/I158842170","display_name":"Chongqing University","ror":"https://ror.org/023rhb549","country_code":"CN","type":"education","lineage":["https://openalex.org/I158842170"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Ming Yang","raw_affiliation_strings":["State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, China","[State Key laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, 47913 Chongqing, China, 400044 (e-mail: cqucee@cqu.edu.cn)]"],"raw_orcid":"https://orcid.org/0000-0001-9907-0364","affiliations":[{"raw_affiliation_string":"State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, China","institution_ids":["https://openalex.org/I158842170"]},{"raw_affiliation_string":"[State Key laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, 47913 Chongqing, China, 400044 (e-mail: cqucee@cqu.edu.cn)]","institution_ids":["https://openalex.org/I158842170"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5008644072","display_name":"Xiaofeng Wang","orcid":"https://orcid.org/0000-0002-8973-7580"},"institutions":[{"id":"https://openalex.org/I158842170","display_name":"Chongqing University","ror":"https://ror.org/023rhb549","country_code":"CN","type":"education","lineage":["https://openalex.org/I158842170"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xiaofeng Wang","raw_affiliation_strings":["State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, China","[State Key laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, 47913 Chongqing, China, (e-mail: xiaofengwang@cqu.edu.cn)]"],"raw_orcid":"https://orcid.org/0000-0002-8973-7580","affiliations":[{"raw_affiliation_string":"State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, China","institution_ids":["https://openalex.org/I158842170"]},{"raw_affiliation_string":"[State Key laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, 47913 Chongqing, China, (e-mail: xiaofengwang@cqu.edu.cn)]","institution_ids":["https://openalex.org/I158842170"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5108615868","display_name":"Wenxia Sima","orcid":"https://orcid.org/0000-0002-1110-9090"},"institutions":[{"id":"https://openalex.org/I158842170","display_name":"Chongqing University","ror":"https://ror.org/023rhb549","country_code":"CN","type":"education","lineage":["https://openalex.org/I158842170"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Wenxia Sima","raw_affiliation_strings":["State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, China","[Chongqing University, 47913 Chongqing, Chongqing, China, (e-mail: cqsmwx@cqu.edu.cn)]"],"raw_orcid":"https://orcid.org/0000-0002-1110-9090","affiliations":[{"raw_affiliation_string":"State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, China","institution_ids":["https://openalex.org/I158842170"]},{"raw_affiliation_string":"[Chongqing University, 47913 Chongqing, Chongqing, China, (e-mail: cqsmwx@cqu.edu.cn)]","institution_ids":["https://openalex.org/I158842170"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5004217039","display_name":"Tao Yuan","orcid":"https://orcid.org/0000-0002-2878-7605"},"institutions":[{"id":"https://openalex.org/I158842170","display_name":"Chongqing University","ror":"https://ror.org/023rhb549","country_code":"CN","type":"education","lineage":["https://openalex.org/I158842170"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Tao Yuan","raw_affiliation_strings":["State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, China","[Chongqing University, 47913 Chongqing, Sichuan, China, (e-mail: yuantao_cq@cqu.edu.cn)]"],"raw_orcid":"https://orcid.org/0000-0002-2878-7605","affiliations":[{"raw_affiliation_string":"State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, China","institution_ids":["https://openalex.org/I158842170"]},{"raw_affiliation_string":"[Chongqing University, 47913 Chongqing, Sichuan, China, (e-mail: yuantao_cq@cqu.edu.cn)]","institution_ids":["https://openalex.org/I158842170"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5037849436","display_name":"Potao Sun","orcid":"https://orcid.org/0000-0002-9155-4302"},"institutions":[{"id":"https://openalex.org/I158842170","display_name":"Chongqing University","ror":"https://ror.org/023rhb549","country_code":"CN","type":"education","lineage":["https://openalex.org/I158842170"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Potao Sun","raw_affiliation_strings":["State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, China","[Chongqing University, 47913 Chongqing, Chongqing, China, (e-mail: sunpotao@cqu.edu.cn)]"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, China","institution_ids":["https://openalex.org/I158842170"]},{"raw_affiliation_string":"[Chongqing University, 47913 Chongqing, Chongqing, China, (e-mail: sunpotao@cqu.edu.cn)]","institution_ids":["https://openalex.org/I158842170"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5010765894","display_name":"Hui Liu","orcid":"https://orcid.org/0000-0002-0516-0383"},"institutions":[{"id":"https://openalex.org/I158842170","display_name":"Chongqing University","ror":"https://ror.org/023rhb549","country_code":"CN","type":"education","lineage":["https://openalex.org/I158842170"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Hui Liu","raw_affiliation_strings":["State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, China","[State Key laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, 47913 Chongqing, China, (e-mail: cquliuhui@cqu.edu.cn)]"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, China","institution_ids":["https://openalex.org/I158842170"]},{"raw_affiliation_string":"[State Key laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, 47913 Chongqing, China, (e-mail: cquliuhui@cqu.edu.cn)]","institution_ids":["https://openalex.org/I158842170"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":6,"corresponding_author_ids":["https://openalex.org/A5091628886"],"corresponding_institution_ids":["https://openalex.org/I158842170"],"apc_list":null,"apc_paid":null,"fwci":2.5418,"has_fulltext":false,"cited_by_count":37,"citation_normalized_percentile":{"value":0.89746857,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":96,"max":99},"biblio":{"volume":"69","issue":"5","first_page":"4914","last_page":"4925"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.951200008392334,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12598","display_name":"Cardiac Structural Anomalies and Repair","score":0.9340999722480774,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fault-current-limiter","display_name":"Fault current limiter","score":0.9173470139503479},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.563107430934906},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.5583279132843018},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.51717609167099},{"id":"https://openalex.org/keywords/current-limiting","display_name":"Current limiting","score":0.5098325610160828},{"id":"https://openalex.org/keywords/circuit-breaker","display_name":"Circuit breaker","score":0.4946741759777069},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.47887223958969116},{"id":"https://openalex.org/keywords/high-voltage-direct-current","display_name":"High-voltage direct current","score":0.4655642509460449},{"id":"https://openalex.org/keywords/inductance","display_name":"Inductance","score":0.45006194710731506},{"id":"https://openalex.org/keywords/transmission-system","display_name":"Transmission system","score":0.42088523507118225},{"id":"https://openalex.org/keywords/direct-current","display_name":"Direct current","score":0.40518462657928467},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.3923591375350952},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.385018527507782},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.3454970121383667},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3058732748031616},{"id":"https://openalex.org/keywords/transmission","display_name":"Transmission (telecommunications)","score":0.1882328987121582},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.1814655363559723},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.09412255883216858}],"concepts":[{"id":"https://openalex.org/C129187525","wikidata":"https://www.wikidata.org/wiki/Q10858078","display_name":"Fault current limiter","level":4,"score":0.9173470139503479},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.563107430934906},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5583279132843018},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.51717609167099},{"id":"https://openalex.org/C204106720","wikidata":"https://www.wikidata.org/wiki/Q15856134","display_name":"Current limiting","level":3,"score":0.5098325610160828},{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.4946741759777069},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.47887223958969116},{"id":"https://openalex.org/C2781163877","wikidata":"https://www.wikidata.org/wiki/Q370607","display_name":"High-voltage direct current","level":4,"score":0.4655642509460449},{"id":"https://openalex.org/C29210110","wikidata":"https://www.wikidata.org/wiki/Q177897","display_name":"Inductance","level":3,"score":0.45006194710731506},{"id":"https://openalex.org/C113608303","wikidata":"https://www.wikidata.org/wiki/Q1056835","display_name":"Transmission system","level":3,"score":0.42088523507118225},{"id":"https://openalex.org/C2776620479","wikidata":"https://www.wikidata.org/wiki/Q159241","display_name":"Direct current","level":3,"score":0.40518462657928467},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.3923591375350952},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.385018527507782},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.3454970121383667},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3058732748031616},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.1882328987121582},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.1814655363559723},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.09412255883216858},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tie.2021.3084165","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2021.3084165","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.8399999737739563}],"awards":[{"id":"https://openalex.org/G2708510816","display_name":null,"funder_award_id":"51837002","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G6898649259","display_name":null,"funder_award_id":"51977018","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"}],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":30,"referenced_works":["https://openalex.org/W2036456454","https://openalex.org/W2070917720","https://openalex.org/W2077977312","https://openalex.org/W2100945405","https://openalex.org/W2103363136","https://openalex.org/W2107869960","https://openalex.org/W2124881904","https://openalex.org/W2140562988","https://openalex.org/W2140747623","https://openalex.org/W2295482306","https://openalex.org/W2321431764","https://openalex.org/W2593784709","https://openalex.org/W2649277844","https://openalex.org/W2673002214","https://openalex.org/W2768078893","https://openalex.org/W2791814691","https://openalex.org/W2793212376","https://openalex.org/W2890423658","https://openalex.org/W2898927164","https://openalex.org/W2913189616","https://openalex.org/W2914164095","https://openalex.org/W2949851680","https://openalex.org/W2953090384","https://openalex.org/W2983300242","https://openalex.org/W2993901046","https://openalex.org/W2999594400","https://openalex.org/W3002371152","https://openalex.org/W3009289708","https://openalex.org/W3088214624","https://openalex.org/W4245919541"],"related_works":["https://openalex.org/W2120692498","https://openalex.org/W2393419321","https://openalex.org/W3094667972","https://openalex.org/W3003057893","https://openalex.org/W1588147484","https://openalex.org/W2362061239","https://openalex.org/W2043353776","https://openalex.org/W3094785063","https://openalex.org/W4366963057","https://openalex.org/W1543529930"],"abstract_inverted_index":{"Modular":[0],"multilevel":[1],"converter":[2],"(MMC)":[3],"high-voltage":[4],"direct":[5],"current":[6,22],"(HVdc)":[7],"transmission":[8],"is":[9],"a":[10],"promising":[11],"method":[12],"to":[13,51,88,110,137],"integrate":[14],"renewable":[15],"energies.":[16],"However,":[17],"limiting":[18],"the":[19,25,47,61,76,80,84,90,103,107,112,121,124,128],"dc-link":[20],"fault":[21,86,96],"and":[23,55,72,93,117,144],"accelerating":[24],"fault-current":[26,41,53,69],"clearance":[27],"are":[28],"critical":[29],"issues":[30],"for":[31],"MMC-HVdc":[32],"systems.":[33,131],"In":[34],"this":[35],"article,":[36],"we":[37],"propose":[38],"an":[39],"air-core-transformer-based":[40],"limiter":[42,70],"(ACT-FCL)":[43],"in":[44,127],"cooperation":[45],"with":[46,60],"dc":[48,63,85,142,146],"circuit":[49],"breaker":[50],"limit":[52],"rising":[54,91],"decrease":[56,102],"fault-clearing":[57,113],"time.":[58,114],"Compared":[59],"conventional":[62],"reactor,":[64],"hybrid":[65],"current-limiting":[66],"circuit,":[67],"current-commutation-based":[68],"(FCL),":[71],"magnetic":[73],"coupling":[74],"FCL,":[75],"ACT-FCL":[77,99,126,133],"can":[78,100],"increase":[79],"equivalent":[81,104],"inductance":[82,105],"during":[83,106],"stage":[87,109],"reduce":[89,111],"rate":[92],"peak":[94],"of":[95,123],"current.":[97],"The":[98,115,132],"also":[101],"fault-current-clearing":[108],"simulations":[116],"laboratory":[118],"experiments":[119],"verify":[120],"effectiveness":[122],"proposed":[125],"bidirectional":[129],"HVdc":[130],"may":[134],"be":[135],"extended":[136],"more":[138],"fields,":[139],"such":[140],"as":[141],"microgrid":[143],"domestic":[145],"transmission.":[147]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":11},{"year":2024,"cited_by_count":7},{"year":2023,"cited_by_count":12},{"year":2022,"cited_by_count":6}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}