{"id":"https://openalex.org/W3154987097","doi":"https://doi.org/10.1109/tie.2021.3071678","title":"Comprehensive Broken Damper Bar Fault Detection of Synchronous Generators","display_name":"Comprehensive Broken Damper Bar Fault Detection of Synchronous Generators","publication_year":2021,"publication_date":"2021-04-13","ids":{"openalex":"https://openalex.org/W3154987097","doi":"https://doi.org/10.1109/tie.2021.3071678","mag":"3154987097"},"language":"en","primary_location":{"id":"doi:10.1109/tie.2021.3071678","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2021.3071678","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://hdl.handle.net/11250/3105090","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5075283838","display_name":"Hossein Ehya","orcid":"https://orcid.org/0000-0001-7264-2596"},"institutions":[{"id":"https://openalex.org/I204778367","display_name":"Norwegian University of Science and Technology","ror":"https://ror.org/05xg72x27","country_code":"NO","type":"education","lineage":["https://openalex.org/I204778367"]}],"countries":["NO"],"is_corresponding":false,"raw_author_name":"Hossein Ehya","raw_affiliation_strings":["Department of Electrical Power Engineering, Norwegian University of Science and Technology, Trondheim, Norway"],"raw_orcid":"https://orcid.org/0000-0001-7264-2596","affiliations":[{"raw_affiliation_string":"Department of Electrical Power Engineering, Norwegian University of Science and Technology, Trondheim, Norway","institution_ids":["https://openalex.org/I204778367"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5089628159","display_name":"Arne Nysveen","orcid":"https://orcid.org/0000-0001-5630-5493"},"institutions":[{"id":"https://openalex.org/I204778367","display_name":"Norwegian University of Science and Technology","ror":"https://ror.org/05xg72x27","country_code":"NO","type":"education","lineage":["https://openalex.org/I204778367"]}],"countries":["NO"],"is_corresponding":false,"raw_author_name":"Arne Nysveen","raw_affiliation_strings":["Department of Electrical Power Engineering, Norwegian University of Science and Technology, Trondheim, Norway"],"raw_orcid":"https://orcid.org/0000-0001-5630-5493","affiliations":[{"raw_affiliation_string":"Department of Electrical Power Engineering, Norwegian University of Science and Technology, Trondheim, Norway","institution_ids":["https://openalex.org/I204778367"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I204778367"],"apc_list":null,"apc_paid":null,"fwci":1.8947,"has_fulltext":false,"cited_by_count":20,"citation_normalized_percentile":{"value":0.85372184,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":"69","issue":"4","first_page":"4215","last_page":"4224"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13050","display_name":"Oil and Gas Production Techniques","score":0.9952999949455261,"subfield":{"id":"https://openalex.org/subfields/2212","display_name":"Ocean Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.9948999881744385,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/transient","display_name":"Transient (computer programming)","score":0.7696927785873413},{"id":"https://openalex.org/keywords/damper","display_name":"Damper","score":0.7564857006072998},{"id":"https://openalex.org/keywords/rotor","display_name":"Rotor (electric)","score":0.6564322710037231},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.6125683784484863},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.5689594149589539},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.5564221739768982},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.5404667854309082},{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.4684109091758728},{"id":"https://openalex.org/keywords/bar","display_name":"Bar (unit)","score":0.4195799231529236},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3937728703022003},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.3796449899673462},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.22090932726860046},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.09000349044799805},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.08804699778556824},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.0730588436126709}],"concepts":[{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.7696927785873413},{"id":"https://openalex.org/C140096630","wikidata":"https://www.wikidata.org/wiki/Q3423628","display_name":"Damper","level":2,"score":0.7564857006072998},{"id":"https://openalex.org/C17281054","wikidata":"https://www.wikidata.org/wiki/Q193466","display_name":"Rotor (electric)","level":2,"score":0.6564322710037231},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6125683784484863},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.5689594149589539},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.5564221739768982},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5404667854309082},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.4684109091758728},{"id":"https://openalex.org/C188721877","wikidata":"https://www.wikidata.org/wiki/Q103510","display_name":"Bar (unit)","level":2,"score":0.4195799231529236},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3937728703022003},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3796449899673462},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.22090932726860046},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.09000349044799805},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.08804699778556824},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0730588436126709},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/tie.2021.3071678","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2021.3071678","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},{"id":"pmh:oai:ntnuopen.ntnu.no:11250/3105090","is_oa":true,"landing_page_url":"https://hdl.handle.net/11250/3105090","pdf_url":null,"source":{"id":"https://openalex.org/S4306401716","display_name":"Duo Research Archive (University of Oslo)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I184942183","host_organization_name":"University of Oslo","host_organization_lineage":["https://openalex.org/I184942183"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"4215-4224","raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":{"id":"pmh:oai:ntnuopen.ntnu.no:11250/3105090","is_oa":true,"landing_page_url":"https://hdl.handle.net/11250/3105090","pdf_url":null,"source":{"id":"https://openalex.org/S4306401716","display_name":"Duo Research Archive (University of Oslo)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I184942183","host_organization_name":"University of Oslo","host_organization_lineage":["https://openalex.org/I184942183"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"4215-4224","raw_type":"info:eu-repo/semantics/article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.7099999785423279,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":23,"referenced_works":["https://openalex.org/W1550119813","https://openalex.org/W1593025320","https://openalex.org/W1988381089","https://openalex.org/W2043208150","https://openalex.org/W2064962021","https://openalex.org/W2065610883","https://openalex.org/W2075373489","https://openalex.org/W2099858396","https://openalex.org/W2103155805","https://openalex.org/W2136340500","https://openalex.org/W2165294517","https://openalex.org/W2170051547","https://openalex.org/W2186098267","https://openalex.org/W2479162436","https://openalex.org/W2551256602","https://openalex.org/W2559325958","https://openalex.org/W2945599707","https://openalex.org/W2995836887","https://openalex.org/W2995869986","https://openalex.org/W2999568567","https://openalex.org/W3014631534","https://openalex.org/W6675953153","https://openalex.org/W6729402764"],"related_works":["https://openalex.org/W2376654678","https://openalex.org/W2350459724","https://openalex.org/W2347463828","https://openalex.org/W2368408103","https://openalex.org/W2367633174","https://openalex.org/W2960067299","https://openalex.org/W2040322304","https://openalex.org/W2381958039","https://openalex.org/W2166090182","https://openalex.org/W1946010015"],"abstract_inverted_index":{"Reliable":[0],"operation":[1,32,132],"of":[2,23,54,59,86,141,171],"synchronous":[3,26],"generators":[4,27],"in":[5,52,134,180],"hydroelectric":[6],"power":[7],"plants":[8],"is":[9,39,66,110,145,162],"crucial":[10],"for":[11,68,73],"avoiding":[12],"unplanned":[13],"stoppages":[14],"that":[15,43,95,123],"can":[16,96,124],"incur":[17],"substantial":[18],"costs.":[19],"The":[20,139,159],"damper":[21,62],"winding":[22],"salient":[24],"pole":[25],"(SPSGs)":[28],"contributes":[29],"to":[30,120,164],"machine":[31],"only":[33,100],"during":[34,101,130,174],"transient":[35,102,131,175],"periods;":[36],"however,":[37],"it":[38],"a":[40,55,60,107,114,126,155,166],"critical":[41],"component":[42],"preserves":[44],"the":[45,50,74,87,135,142],"dynamic":[46],"stability":[47],"and":[48,150,168],"protects":[49],"rotor":[51],"case":[53],"fault.":[56],"Consequently,":[57],"detection":[58,76],"broken":[61],"bar":[63],"(BDB)":[64],"fault":[65,128],"vital":[67],"safe":[69],"operation.":[70,103],"Current":[71],"methods":[72],"BDB":[75,98,121,127,172],"depend":[77],"on":[78,113],"visual":[79],"inspection":[80],"or":[81,133,176],"offline":[82],"tests.":[83],"However,":[84],"most":[85],"recently":[88],"proposed":[89,111,143,160],"approaches":[90],"have":[91],"used":[92],"invasive":[93],"sensors":[94],"detect":[97],"faults":[99,122,173],"In":[104],"this":[105],"article,":[106],"novel":[108],"method":[109,144,161],"based":[112],"noninvasive":[115],"sensor":[116],"with":[117],"high":[118],"sensitivity":[119],"identify":[125],"either":[129],"steady-state":[136],"(SS)":[137],"period.":[138],"effectiveness":[140],"validated":[146],"by":[147,151],"finite-element":[148],"modeling":[149],"experimental":[152],"results":[153],"from":[154],"100-kVA":[156],"custom-made":[157],"SPSG.":[158],"confirmed":[163],"provide":[165],"reliable":[167],"sensitive":[169],"diagnosis":[170],"SS":[177],"operation,":[178],"even":[179],"noisy":[181],"environments.":[182]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":5},{"year":2023,"cited_by_count":5},{"year":2022,"cited_by_count":8},{"year":2021,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}