{"id":"https://openalex.org/W2947451194","doi":"https://doi.org/10.1109/tie.2019.2918471","title":"Improved Online Maximum-Torque-Per-Ampere Algorithm for Speed Controlled Interior Permanent Magnet Synchronous Machine","display_name":"Improved Online Maximum-Torque-Per-Ampere Algorithm for Speed Controlled Interior Permanent Magnet Synchronous Machine","publication_year":2019,"publication_date":"2019-05-29","ids":{"openalex":"https://openalex.org/W2947451194","doi":"https://doi.org/10.1109/tie.2019.2918471","mag":"2947451194"},"language":"en","primary_location":{"id":"doi:10.1109/tie.2019.2918471","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2019.2918471","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5071045010","display_name":"Zexiu Han","orcid":null},"institutions":[{"id":"https://openalex.org/I17145004","display_name":"Northwestern Polytechnical University","ror":"https://ror.org/01y0j0j86","country_code":"CN","type":"education","lineage":["https://openalex.org/I17145004"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Zexiu Han","raw_affiliation_strings":["Shaanxi Key Laboratory of Small and Special Electrical Machine and Drive Technology, School of Automation, Nothwestern Polytechnical University, Xi'an, China"],"affiliations":[{"raw_affiliation_string":"Shaanxi Key Laboratory of Small and Special Electrical Machine and Drive Technology, School of Automation, Nothwestern Polytechnical University, Xi'an, China","institution_ids":["https://openalex.org/I17145004"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5065126806","display_name":"Jinglin Liu","orcid":"https://orcid.org/0000-0002-9905-3887"},"institutions":[{"id":"https://openalex.org/I17145004","display_name":"Northwestern Polytechnical University","ror":"https://ror.org/01y0j0j86","country_code":"CN","type":"education","lineage":["https://openalex.org/I17145004"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jinglin Liu","raw_affiliation_strings":["Shaanxi Key Laboratory of Small and Special Electrical Machine and Drive Technology, School of Automation, Nothwestern Polytechnical University, Xi'an, China"],"affiliations":[{"raw_affiliation_string":"Shaanxi Key Laboratory of Small and Special Electrical Machine and Drive Technology, School of Automation, Nothwestern Polytechnical University, Xi'an, China","institution_ids":["https://openalex.org/I17145004"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5033796018","display_name":"Weibin Yang","orcid":"https://orcid.org/0000-0002-6987-9282"},"institutions":[{"id":"https://openalex.org/I40527276","display_name":"Universit\u00e4t der Bundeswehr M\u00fcnchen","ror":"https://ror.org/05kkv3f82","country_code":"DE","type":"education","lineage":["https://openalex.org/I1315109972","https://openalex.org/I40527276","https://openalex.org/I4387152969"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Weibin Yang","raw_affiliation_strings":["Institute for Electrical Drives and Actuators, Universitaet der Bundeswehr, Munich, Germany"],"affiliations":[{"raw_affiliation_string":"Institute for Electrical Drives and Actuators, Universitaet der Bundeswehr, Munich, Germany","institution_ids":["https://openalex.org/I40527276"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5010724001","display_name":"Daniel Bachinski Pinhal","orcid":null},"institutions":[{"id":"https://openalex.org/I40527276","display_name":"Universit\u00e4t der Bundeswehr M\u00fcnchen","ror":"https://ror.org/05kkv3f82","country_code":"DE","type":"education","lineage":["https://openalex.org/I1315109972","https://openalex.org/I40527276","https://openalex.org/I4387152969"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Daniel Bachinski Pinhal","raw_affiliation_strings":["Institute for Electrical Drives and Actuators, Universitaet der Bundeswehr, Munich, Germany"],"affiliations":[{"raw_affiliation_string":"Institute for Electrical Drives and Actuators, Universitaet der Bundeswehr, Munich, Germany","institution_ids":["https://openalex.org/I40527276"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5079596721","display_name":"Nikolaus Reiland","orcid":null},"institutions":[{"id":"https://openalex.org/I40527276","display_name":"Universit\u00e4t der Bundeswehr M\u00fcnchen","ror":"https://ror.org/05kkv3f82","country_code":"DE","type":"education","lineage":["https://openalex.org/I1315109972","https://openalex.org/I40527276","https://openalex.org/I4387152969"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Nikolaus Reiland","raw_affiliation_strings":["Institute for Electrical Drives and Actuators, Universitaet der Bundeswehr, Munich, Germany"],"affiliations":[{"raw_affiliation_string":"Institute for Electrical Drives and Actuators, Universitaet der Bundeswehr, Munich, Germany","institution_ids":["https://openalex.org/I40527276"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5013155565","display_name":"Dieter Gerling","orcid":"https://orcid.org/0000-0002-1831-154X"},"institutions":[{"id":"https://openalex.org/I40527276","display_name":"Universit\u00e4t der Bundeswehr M\u00fcnchen","ror":"https://ror.org/05kkv3f82","country_code":"DE","type":"education","lineage":["https://openalex.org/I1315109972","https://openalex.org/I40527276","https://openalex.org/I4387152969"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Dieter Gerling","raw_affiliation_strings":["Institute for Electrical Drives and Actuators, Universitaet der Bundeswehr, Munich, Germany"],"affiliations":[{"raw_affiliation_string":"Institute for Electrical Drives and Actuators, Universitaet der Bundeswehr, Munich, Germany","institution_ids":["https://openalex.org/I40527276"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":6,"corresponding_author_ids":["https://openalex.org/A5071045010"],"corresponding_institution_ids":["https://openalex.org/I17145004"],"apc_list":null,"apc_paid":null,"fwci":2.5335,"has_fulltext":false,"cited_by_count":43,"citation_normalized_percentile":{"value":0.89808546,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":99},"biblio":{"volume":"67","issue":"5","first_page":"3398","last_page":"3408"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10504","display_name":"Sensorless Control of Electric Motors","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9988999962806702,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.731837272644043},{"id":"https://openalex.org/keywords/inductance","display_name":"Inductance","score":0.7117872834205627},{"id":"https://openalex.org/keywords/stator","display_name":"Stator","score":0.6645813584327698},{"id":"https://openalex.org/keywords/torque","display_name":"Torque","score":0.6610109806060791},{"id":"https://openalex.org/keywords/ampere","display_name":"Ampere","score":0.6464946269989014},{"id":"https://openalex.org/keywords/compensation","display_name":"Compensation (psychology)","score":0.506515622138977},{"id":"https://openalex.org/keywords/magnet","display_name":"Magnet","score":0.5025680065155029},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4582262933254242},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4406314492225647},{"id":"https://openalex.org/keywords/synchronous-motor","display_name":"Synchronous motor","score":0.42246323823928833},{"id":"https://openalex.org/keywords/point","display_name":"Point (geometry)","score":0.4196832776069641},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.3722778558731079},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.29939961433410645},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.20911851525306702},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.20034706592559814},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.11055964231491089},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.08142781257629395}],"concepts":[{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.731837272644043},{"id":"https://openalex.org/C29210110","wikidata":"https://www.wikidata.org/wiki/Q177897","display_name":"Inductance","level":3,"score":0.7117872834205627},{"id":"https://openalex.org/C2776529397","wikidata":"https://www.wikidata.org/wiki/Q190312","display_name":"Stator","level":2,"score":0.6645813584327698},{"id":"https://openalex.org/C144171764","wikidata":"https://www.wikidata.org/wiki/Q48103","display_name":"Torque","level":2,"score":0.6610109806060791},{"id":"https://openalex.org/C4941483","wikidata":"https://www.wikidata.org/wiki/Q25272","display_name":"Ampere","level":3,"score":0.6464946269989014},{"id":"https://openalex.org/C2780023022","wikidata":"https://www.wikidata.org/wiki/Q1338171","display_name":"Compensation (psychology)","level":2,"score":0.506515622138977},{"id":"https://openalex.org/C16389437","wikidata":"https://www.wikidata.org/wiki/Q11421","display_name":"Magnet","level":2,"score":0.5025680065155029},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4582262933254242},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4406314492225647},{"id":"https://openalex.org/C71376005","wikidata":"https://www.wikidata.org/wiki/Q845675","display_name":"Synchronous motor","level":2,"score":0.42246323823928833},{"id":"https://openalex.org/C28719098","wikidata":"https://www.wikidata.org/wiki/Q44946","display_name":"Point (geometry)","level":2,"score":0.4196832776069641},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.3722778558731079},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.29939961433410645},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.20911851525306702},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.20034706592559814},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.11055964231491089},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.08142781257629395},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C11171543","wikidata":"https://www.wikidata.org/wiki/Q41630","display_name":"Psychoanalysis","level":1,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C15744967","wikidata":"https://www.wikidata.org/wiki/Q9418","display_name":"Psychology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tie.2019.2918471","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2019.2918471","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.8299999833106995}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":28,"referenced_works":["https://openalex.org/W1585977362","https://openalex.org/W1981650602","https://openalex.org/W1995665808","https://openalex.org/W2048063226","https://openalex.org/W2055617902","https://openalex.org/W2080708194","https://openalex.org/W2085322904","https://openalex.org/W2099282970","https://openalex.org/W2101733383","https://openalex.org/W2130469254","https://openalex.org/W2131080316","https://openalex.org/W2135111027","https://openalex.org/W2147693414","https://openalex.org/W2153702697","https://openalex.org/W2154959707","https://openalex.org/W2157097428","https://openalex.org/W2158200547","https://openalex.org/W2164958286","https://openalex.org/W2327621369","https://openalex.org/W2344881401","https://openalex.org/W2541050477","https://openalex.org/W2558304049","https://openalex.org/W2596997902","https://openalex.org/W2765789997","https://openalex.org/W6664294527","https://openalex.org/W6675072260","https://openalex.org/W6682418160","https://openalex.org/W6683244699"],"related_works":["https://openalex.org/W623794290","https://openalex.org/W2372255233","https://openalex.org/W2361693169","https://openalex.org/W2130828945","https://openalex.org/W2360961134","https://openalex.org/W2350949866","https://openalex.org/W2039525340","https://openalex.org/W2325040020","https://openalex.org/W2378651499","https://openalex.org/W4389723183"],"abstract_inverted_index":{"In":[0,62],"order":[1],"to":[2,28,79,89],"improve":[3],"the":[4,30,39,43,54,65,75,81,99,102,112,127,132,149],"performance":[5],"of":[6,42,56,101,114],"interior":[7],"permanent":[8,49],"magnet":[9],"synchronous":[10],"machine":[11],"(IPMSM)":[12],"based":[13,110],"on":[14,111,143],"space":[15],"voltage":[16],"vector":[17],"modulation":[18],"schemes,":[19],"this":[20,63,117],"paper":[21,118],"presents":[22],"a":[23,69,95,120],"highly":[24],"accurate":[25],"online":[26],"method":[27,67,106],"find":[29],"proper":[31],"maximum-torque-per-ampere":[32],"(MTPA)":[33],"angles.":[34],"This":[35],"algorithm":[36],"fully":[37],"considers":[38],"nonlinear":[40],"characteristics":[41],"d-axis":[44],"inductance,":[45,47],"q-axis":[46],"and":[48,135,153],"magnetic":[50],"flux":[51],"together.":[52],"Additionally,":[53],"influences":[55],"temperature":[57],"are":[58],"taken":[59],"into":[60,74],"account.":[61],"paper,":[64],"proposed":[66,150],"injects":[68],"small":[70],"virtual":[71,103],"angle":[72,77,85,129],"signal":[73,104],"current":[76,83,128],"mathematically":[78],"track":[80],"stator":[82],"reference":[84],"that":[86,123],"is":[87,107],"close":[88],"real":[90,136],"MTPA":[91,137],"points.":[92],"Moreover,":[93],"following":[94],"theoretical":[96],"analysis":[97],"method,":[98],"error":[100,115,130],"injection":[105],"analyzed.":[108],"Then,":[109],"results":[113],"analysis,":[116],"proposes":[119],"compensation":[121],"strategy":[122],"can":[124],"significantly":[125],"reduce":[126],"between":[131],"tracking":[133],"point":[134],"point.":[138],"At":[139],"last,":[140],"various":[141],"experiments":[142],"an":[144],"IPMSM":[145],"test":[146],"bench":[147],"verify":[148],"control":[151],"technique":[152],"overall":[154],"performance.":[155]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":6},{"year":2024,"cited_by_count":8},{"year":2023,"cited_by_count":7},{"year":2022,"cited_by_count":8},{"year":2021,"cited_by_count":4},{"year":2020,"cited_by_count":8},{"year":2019,"cited_by_count":1}],"updated_date":"2026-03-27T05:58:40.876381","created_date":"2025-10-10T00:00:00"}
