{"id":"https://openalex.org/W2806568617","doi":"https://doi.org/10.1109/tie.2018.2840496","title":"Analysis and Design of High-Efficiency Hybrid High Step-Up DC\u2013DC Converter for Distributed PV Generation Systems","display_name":"Analysis and Design of High-Efficiency Hybrid High Step-Up DC\u2013DC Converter for Distributed PV Generation Systems","publication_year":2018,"publication_date":"2018-06-01","ids":{"openalex":"https://openalex.org/W2806568617","doi":"https://doi.org/10.1109/tie.2018.2840496","mag":"2806568617"},"language":"en","primary_location":{"id":"doi:10.1109/tie.2018.2840496","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2018.2840496","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5012479770","display_name":"Ant\u00f3nio Manuel Santos Spencer Andrade","orcid":"https://orcid.org/0000-0001-6098-0475"},"institutions":[{"id":"https://openalex.org/I33501960","display_name":"Universidade Federal de Santa Maria","ror":"https://ror.org/01b78mz79","country_code":"BR","type":"education","lineage":["https://openalex.org/I33501960"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Antonio Manuel Santos Spencer Andrade","raw_affiliation_strings":["Power Electronics and Control Research Group, Federal University of Santa Maria, Santa Maria, Brazil"],"raw_orcid":"https://orcid.org/0000-0001-6098-0475","affiliations":[{"raw_affiliation_string":"Power Electronics and Control Research Group, Federal University of Santa Maria, Santa Maria, Brazil","institution_ids":["https://openalex.org/I33501960"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5067032596","display_name":"Luciano Schuch","orcid":"https://orcid.org/0000-0003-2284-3837"},"institutions":[{"id":"https://openalex.org/I33501960","display_name":"Universidade Federal de Santa Maria","ror":"https://ror.org/01b78mz79","country_code":"BR","type":"education","lineage":["https://openalex.org/I33501960"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Luciano Schuch","raw_affiliation_strings":["Power Electronics and Control Research Group, Federal University of Santa Maria, Santa Maria, Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Power Electronics and Control Research Group, Federal University of Santa Maria, Santa Maria, Brazil","institution_ids":["https://openalex.org/I33501960"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5016327958","display_name":"M\u00e1rio L\u00facio da Silva Martins","orcid":"https://orcid.org/0000-0002-0912-3571"},"institutions":[{"id":"https://openalex.org/I33501960","display_name":"Universidade Federal de Santa Maria","ror":"https://ror.org/01b78mz79","country_code":"BR","type":"education","lineage":["https://openalex.org/I33501960"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Mario Lucio da Silva Martins","raw_affiliation_strings":["Power Electronics and Control Research Group, Federal University of Santa Maria, Santa Maria, Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Power Electronics and Control Research Group, Federal University of Santa Maria, Santa Maria, Brazil","institution_ids":["https://openalex.org/I33501960"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I33501960"],"apc_list":null,"apc_paid":null,"fwci":8.9044,"has_fulltext":false,"cited_by_count":174,"citation_normalized_percentile":{"value":0.98273337,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":99,"max":100},"biblio":{"volume":"66","issue":"5","first_page":"3860","last_page":"3868"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9980999827384949,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10663","display_name":"Advanced Battery Technologies Research","score":0.9977999925613403,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/boost-converter","display_name":"Boost converter","score":0.6968293786048889},{"id":"https://openalex.org/keywords/\u0107uk-converter","display_name":"\u0106uk converter","score":0.6325357556343079},{"id":"https://openalex.org/keywords/inductor","display_name":"Inductor","score":0.5967987775802612},{"id":"https://openalex.org/keywords/photovoltaic-system","display_name":"Photovoltaic system","score":0.5746446847915649},{"id":"https://openalex.org/keywords/forward-converter","display_name":"Forward converter","score":0.569208025932312},{"id":"https://openalex.org/keywords/charge-pump","display_name":"Charge pump","score":0.5600569248199463},{"id":"https://openalex.org/keywords/duty-cycle","display_name":"Duty cycle","score":0.5360000729560852},{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.535876989364624},{"id":"https://openalex.org/keywords/flyback-converter","display_name":"Flyback converter","score":0.4984912872314453},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.4851292073726654},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.48212265968322754},{"id":"https://openalex.org/keywords/capacitor","display_name":"Capacitor","score":0.47681137919425964},{"id":"https://openalex.org/keywords/buck-converter","display_name":"Buck converter","score":0.4610629975795746},{"id":"https://openalex.org/keywords/high-voltage","display_name":"High voltage","score":0.42508450150489807},{"id":"https://openalex.org/keywords/buck\u2013boost-converter","display_name":"Buck\u2013boost converter","score":0.41211050748825073},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4084044098854065},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.379773885011673},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3275882601737976}],"concepts":[{"id":"https://openalex.org/C78336795","wikidata":"https://www.wikidata.org/wiki/Q760134","display_name":"Boost converter","level":3,"score":0.6968293786048889},{"id":"https://openalex.org/C100329506","wikidata":"https://www.wikidata.org/wiki/Q336439","display_name":"\u0106uk converter","level":4,"score":0.6325357556343079},{"id":"https://openalex.org/C144534570","wikidata":"https://www.wikidata.org/wiki/Q5325","display_name":"Inductor","level":3,"score":0.5967987775802612},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.5746446847915649},{"id":"https://openalex.org/C55118286","wikidata":"https://www.wikidata.org/wiki/Q634739","display_name":"Forward converter","level":4,"score":0.569208025932312},{"id":"https://openalex.org/C114825011","wikidata":"https://www.wikidata.org/wiki/Q440704","display_name":"Charge pump","level":4,"score":0.5600569248199463},{"id":"https://openalex.org/C199822604","wikidata":"https://www.wikidata.org/wiki/Q557120","display_name":"Duty cycle","level":3,"score":0.5360000729560852},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.535876989364624},{"id":"https://openalex.org/C103303742","wikidata":"https://www.wikidata.org/wiki/Q1293595","display_name":"Flyback converter","level":4,"score":0.4984912872314453},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4851292073726654},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.48212265968322754},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.47681137919425964},{"id":"https://openalex.org/C150818752","wikidata":"https://www.wikidata.org/wiki/Q83804","display_name":"Buck converter","level":3,"score":0.4610629975795746},{"id":"https://openalex.org/C88182573","wikidata":"https://www.wikidata.org/wiki/Q1139740","display_name":"High voltage","level":3,"score":0.42508450150489807},{"id":"https://openalex.org/C42043438","wikidata":"https://www.wikidata.org/wiki/Q1671740","display_name":"Buck\u2013boost converter","level":4,"score":0.41211050748825073},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4084044098854065},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.379773885011673},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3275882601737976}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tie.2018.2840496","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2018.2840496","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.8299999833106995,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":23,"referenced_works":["https://openalex.org/W1935902382","https://openalex.org/W1983309199","https://openalex.org/W2049065521","https://openalex.org/W2076054643","https://openalex.org/W2161722474","https://openalex.org/W2203896473","https://openalex.org/W2243207359","https://openalex.org/W2332650409","https://openalex.org/W2489985317","https://openalex.org/W2520546045","https://openalex.org/W2531257039","https://openalex.org/W2534340533","https://openalex.org/W2539324090","https://openalex.org/W2553097211","https://openalex.org/W2593065393","https://openalex.org/W2615546599","https://openalex.org/W2620796339","https://openalex.org/W2740041315","https://openalex.org/W2741173782","https://openalex.org/W2750631510","https://openalex.org/W2751111878","https://openalex.org/W2751507538","https://openalex.org/W6640324870"],"related_works":["https://openalex.org/W2588047361","https://openalex.org/W2783344684","https://openalex.org/W2126740233","https://openalex.org/W1539693063","https://openalex.org/W1497563151","https://openalex.org/W4293193861","https://openalex.org/W2501890988","https://openalex.org/W2971653998","https://openalex.org/W4253126292","https://openalex.org/W2545560698"],"abstract_inverted_index":{"High":[0],"step-up":[1],"converters":[2],"are":[3],"required":[4],"for":[5],"distributed":[6],"photovoltaic":[7,17],"generation":[8],"systems,":[9],"due":[10],"to":[11,71,86],"the":[12,16,34,58,78,88],"low":[13],"voltage":[14,26,64,73],"of":[15,53,77,95],"source.":[18],"In":[19],"this":[20],"paper,":[21],"a":[22,39,47,62,92],"new":[23],"hybrid":[24],"high":[25,63,67],"gain":[27,65],"dc-dc":[28],"converter":[29,37,60],"is":[30],"created":[31],"by":[32],"merging":[33],"standard":[35],"boost":[36],"with":[38],"coupled":[40],"inductor":[41],"and":[42,50,66,74],"different":[43],"switched-capacitor":[44],"techniques.":[45],"With":[46],"single":[48],"switch":[49],"no":[51],"requirement":[52],"higher":[54],"duty":[55],"cycle":[56],"values,":[57],"proposed":[59],"achieves":[61],"efficiency,":[68],"in":[69],"addition":[70],"lowered":[72],"current":[75],"stresses":[76],"components.":[79],"A":[80],"200-W":[81],"prototype":[82],"was":[83],"implemented":[84],"experimentally":[85],"evaluate":[87],"converter,":[89],"which":[90],"reached":[91],"maximum":[93],"efficiency":[94],"97.6%.":[96]},"counts_by_year":[{"year":2026,"cited_by_count":7},{"year":2025,"cited_by_count":23},{"year":2024,"cited_by_count":20},{"year":2023,"cited_by_count":32},{"year":2022,"cited_by_count":24},{"year":2021,"cited_by_count":30},{"year":2020,"cited_by_count":24},{"year":2019,"cited_by_count":14}],"updated_date":"2026-06-26T08:34:08.712188","created_date":"2025-10-10T00:00:00"}
