{"id":"https://openalex.org/W2772997070","doi":"https://doi.org/10.1109/tie.2017.2782200","title":"Offline Interturn Fault Diagnosis Method for Induction Motors by Impedance Analysis","display_name":"Offline Interturn Fault Diagnosis Method for Induction Motors by Impedance Analysis","publication_year":2017,"publication_date":"2017-12-11","ids":{"openalex":"https://openalex.org/W2772997070","doi":"https://doi.org/10.1109/tie.2017.2782200","mag":"2772997070"},"language":"en","primary_location":{"id":"doi:10.1109/tie.2017.2782200","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2017.2782200","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Bon-Gwan Gu","orcid":"https://orcid.org/0000-0002-8538-9320"},"institutions":[{"id":"https://openalex.org/I31419693","display_name":"Kyungpook National University","ror":"https://ror.org/040c17130","country_code":"KR","type":"education","lineage":["https://openalex.org/I31419693"]}],"countries":["KR"],"is_corresponding":true,"raw_author_name":"Bon-Gwan Gu","raw_affiliation_strings":["School of Energy Engineering, Kyungpook National University, Daegu, South Korea"],"raw_orcid":"https://orcid.org/0000-0002-8538-9320","affiliations":[{"raw_affiliation_string":"School of Energy Engineering, Kyungpook National University, Daegu, South Korea","institution_ids":["https://openalex.org/I31419693"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I31419693"],"apc_list":null,"apc_paid":null,"fwci":0.8155,"has_fulltext":false,"cited_by_count":26,"citation_normalized_percentile":{"value":0.75597347,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":99},"biblio":{"volume":"65","issue":"7","first_page":"5913","last_page":"5920"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11222","display_name":"Magnetic Properties and Applications","score":0.9961000084877014,"subfield":{"id":"https://openalex.org/subfields/2504","display_name":"Electronic, Optical and Magnetic Materials"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11062","display_name":"Gear and Bearing Dynamics Analysis","score":0.9936000108718872,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/induction-motor","display_name":"Induction motor","score":0.7279610633850098},{"id":"https://openalex.org/keywords/electrical-impedance","display_name":"Electrical impedance","score":0.7075497508049011},{"id":"https://openalex.org/keywords/electromagnetic-coil","display_name":"Electromagnetic coil","score":0.5948548913002014},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.5849633812904358},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.5736315250396729},{"id":"https://openalex.org/keywords/fast-fourier-transform","display_name":"Fast Fourier transform","score":0.539191484451294},{"id":"https://openalex.org/keywords/impedance-parameters","display_name":"Impedance parameters","score":0.5105041265487671},{"id":"https://openalex.org/keywords/damping-factor","display_name":"Damping factor","score":0.4581517279148102},{"id":"https://openalex.org/keywords/equivalent-circuit","display_name":"Equivalent circuit","score":0.44731104373931885},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.397070050239563},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.3431413769721985},{"id":"https://openalex.org/keywords/input-impedance","display_name":"Input impedance","score":0.3091852366924286},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3010224401950836},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.19996657967567444},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.18023613095283508}],"concepts":[{"id":"https://openalex.org/C80962145","wikidata":"https://www.wikidata.org/wiki/Q207450","display_name":"Induction motor","level":3,"score":0.7279610633850098},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.7075497508049011},{"id":"https://openalex.org/C30403606","wikidata":"https://www.wikidata.org/wiki/Q2981904","display_name":"Electromagnetic coil","level":2,"score":0.5948548913002014},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5849633812904358},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.5736315250396729},{"id":"https://openalex.org/C75172450","wikidata":"https://www.wikidata.org/wiki/Q623950","display_name":"Fast Fourier transform","level":2,"score":0.539191484451294},{"id":"https://openalex.org/C113805353","wikidata":"https://www.wikidata.org/wiki/Q13424600","display_name":"Impedance parameters","level":3,"score":0.5105041265487671},{"id":"https://openalex.org/C48427663","wikidata":"https://www.wikidata.org/wiki/Q1269719","display_name":"Damping factor","level":4,"score":0.4581517279148102},{"id":"https://openalex.org/C23572009","wikidata":"https://www.wikidata.org/wiki/Q964981","display_name":"Equivalent circuit","level":3,"score":0.44731104373931885},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.397070050239563},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3431413769721985},{"id":"https://openalex.org/C26262908","wikidata":"https://www.wikidata.org/wiki/Q1307489","display_name":"Input impedance","level":3,"score":0.3091852366924286},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3010224401950836},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.19996657967567444},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.18023613095283508},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tie.2017.2782200","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2017.2782200","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G4747877645","display_name":null,"funder_award_id":"NRF-2017R1D1A3B03030254","funder_id":"https://openalex.org/F4320322120","funder_display_name":"National Research Foundation of Korea"},{"id":"https://openalex.org/G5572468446","display_name":null,"funder_award_id":"R15XA03-17","funder_id":"https://openalex.org/F4320326258","funder_display_name":"Korea Electric Power Corporation"}],"funders":[{"id":"https://openalex.org/F4320322120","display_name":"National Research Foundation of Korea","ror":"https://ror.org/013aysd81"},{"id":"https://openalex.org/F4320326258","display_name":"Korea Electric Power Corporation","ror":"https://ror.org/04fperw70"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":20,"referenced_works":["https://openalex.org/W1964375741","https://openalex.org/W2003574569","https://openalex.org/W2026743245","https://openalex.org/W2026753505","https://openalex.org/W2043241963","https://openalex.org/W2097362303","https://openalex.org/W2104988213","https://openalex.org/W2132071458","https://openalex.org/W2164709882","https://openalex.org/W2165451779","https://openalex.org/W2180014248","https://openalex.org/W2180015593","https://openalex.org/W2247177755","https://openalex.org/W2293986360","https://openalex.org/W2294908019","https://openalex.org/W2399122540","https://openalex.org/W2474672191","https://openalex.org/W2572727817","https://openalex.org/W2668549309","https://openalex.org/W4239795001"],"related_works":["https://openalex.org/W4385220972","https://openalex.org/W1981255793","https://openalex.org/W2358750504","https://openalex.org/W2115579461","https://openalex.org/W4387426556","https://openalex.org/W1964527951","https://openalex.org/W1994269915","https://openalex.org/W2148839020","https://openalex.org/W4210809443","https://openalex.org/W2123069234"],"abstract_inverted_index":{"In":[0],"this":[1],"paper,":[2],"a":[3,102],"new":[4],"offline":[5],"interturn":[6],"fault":[7,47],"(ITF)":[8],"diagnosis":[9],"method":[10,18],"for":[11,127],"induction":[12,36,129],"motors":[13],"is":[14,19,39],"presented.":[15],"The":[16],"proposed":[17,117],"based":[20],"on":[21,61],"impedance":[22,33,51,76,84],"imbalance":[23],"in":[24,53,78],"the":[25,32,54,62,74,79,82,89,91,94,107,116],"stationary":[26,55],"d-q":[27,56,80],"plane.":[28],"First,":[29],"to":[30,73],"show":[31],"imbalance,":[34],"an":[35,42,128,132],"motor":[37,130],"model":[38],"presented":[40,126],"with":[41],"ITF":[43,92],"circuit":[44],"loop":[45],"and":[46,93,122],"resistance.":[48],"Then,":[49],"six":[50,75],"components":[52,77],"plane":[57],"are":[58,86,125],"defined,":[59],"depending":[60],"excited":[63],"phase":[64,96,109],"windings.":[65],"With":[66],"fast":[67],"Fourier":[68],"transform":[69],"(FFT)":[70],"filtering":[71],"applied":[72],"plane,":[81],"second-order":[83],"magnitudes":[85],"obtained.":[87],"From":[88],"magnitude,":[90],"faulty":[95,104,108],"can":[97,111],"easily":[98],"be":[99,112],"detected.":[100],"Moreover,":[101],"specific":[103],"winding":[105],"among":[106],"windings":[110],"identified.":[113],"To":[114],"verify":[115],"method,":[118],"finite-element":[119],"analysis":[120],"(FEA)":[121],"experimental":[123],"results":[124],"having":[131],"ITF.":[133]},"counts_by_year":[{"year":2025,"cited_by_count":4},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":3},{"year":2022,"cited_by_count":7},{"year":2021,"cited_by_count":7},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
