{"id":"https://openalex.org/W2571168836","doi":"https://doi.org/10.1109/tie.2017.2650870","title":"Generator Short-Circuit Torque Compensation in Multichannel Wind Turbines","display_name":"Generator Short-Circuit Torque Compensation in Multichannel Wind Turbines","publication_year":2017,"publication_date":"2017-01-10","ids":{"openalex":"https://openalex.org/W2571168836","doi":"https://doi.org/10.1109/tie.2017.2650870","mag":"2571168836"},"language":"en","primary_location":{"id":"doi:10.1109/tie.2017.2650870","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2017.2650870","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5015094298","display_name":"Llu\u00eds Trilla","orcid":"https://orcid.org/0000-0002-7586-3834"},"institutions":[{"id":"https://openalex.org/I4210128520","display_name":"Institut de Recerca en Energia de Catalunya","ror":"https://ror.org/03b6f4629","country_code":"ES","type":"facility","lineage":["https://openalex.org/I4210128520","https://openalex.org/I4387153040"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Lluis Trilla","raw_affiliation_strings":["Electrical Engineering Department, Catalonia Institute for Energy Research, Barcelona, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Engineering Department, Catalonia Institute for Energy Research, Barcelona, Spain","institution_ids":["https://openalex.org/I4210128520"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5102954868","display_name":"Jordi Mal\u00e9 i Pegueroles","orcid":"https://orcid.org/0000-0003-1097-0708"},"institutions":[{"id":"https://openalex.org/I4210128520","display_name":"Institut de Recerca en Energia de Catalunya","ror":"https://ror.org/03b6f4629","country_code":"ES","type":"facility","lineage":["https://openalex.org/I4210128520","https://openalex.org/I4387153040"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Jordi Pegueroles","raw_affiliation_strings":["Electrical Engineering Department, Catalonia Institute for Energy Research, Barcelona, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Engineering Department, Catalonia Institute for Energy Research, Barcelona, Spain","institution_ids":["https://openalex.org/I4210128520"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5044168113","display_name":"Julio Urresty","orcid":null},"institutions":[{"id":"https://openalex.org/I2799729401","display_name":"General Electric (Denmark)","ror":"https://ror.org/03nscjy42","country_code":"DK","type":"company","lineage":["https://openalex.org/I1332737386","https://openalex.org/I2799729401"]}],"countries":["DK"],"is_corresponding":false,"raw_author_name":"Julio Urresty","raw_affiliation_strings":["General Electric Renewable Power, Barcelona"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"General Electric Renewable Power, Barcelona","institution_ids":["https://openalex.org/I2799729401"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5087936884","display_name":"Cesar Muniz","orcid":null},"institutions":[{"id":"https://openalex.org/I4210128520","display_name":"Institut de Recerca en Energia de Catalunya","ror":"https://ror.org/03b6f4629","country_code":"ES","type":"facility","lineage":["https://openalex.org/I4210128520","https://openalex.org/I4387153040"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Cesar Muniz","raw_affiliation_strings":["Electrical Engineering Department, Catalonia Institute for Energy Research, Barcelona, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Engineering Department, Catalonia Institute for Energy Research, Barcelona, Spain","institution_ids":["https://openalex.org/I4210128520"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5091210916","display_name":"Oriol Gomis\u2010Bellmunt","orcid":"https://orcid.org/0000-0002-9507-8278"},"institutions":[{"id":"https://openalex.org/I4210128520","display_name":"Institut de Recerca en Energia de Catalunya","ror":"https://ror.org/03b6f4629","country_code":"ES","type":"facility","lineage":["https://openalex.org/I4210128520","https://openalex.org/I4387153040"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Oriol Gomis-Bellmunt","raw_affiliation_strings":["Electrical Engineering Department, Catalonia Institute for Energy Research, Barcelona, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Engineering Department, Catalonia Institute for Energy Research, Barcelona, Spain","institution_ids":["https://openalex.org/I4210128520"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.5848,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.68495585,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"64","issue":"11","first_page":"8790","last_page":"8798"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/stator","display_name":"Stator","score":0.7376617193222046},{"id":"https://openalex.org/keywords/torque","display_name":"Torque","score":0.7346243858337402},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.6960464715957642},{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.6521302461624146},{"id":"https://openalex.org/keywords/generator","display_name":"Generator (circuit theory)","score":0.6230073571205139},{"id":"https://openalex.org/keywords/wind-power","display_name":"Wind power","score":0.6177803874015808},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.5861955285072327},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.5636254549026489},{"id":"https://openalex.org/keywords/induction-generator","display_name":"Induction generator","score":0.5571070313453674},{"id":"https://openalex.org/keywords/compensation","display_name":"Compensation (psychology)","score":0.5174289345741272},{"id":"https://openalex.org/keywords/direct-torque-control","display_name":"Direct torque control","score":0.49375471472740173},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4788803458213806},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.4406081736087799},{"id":"https://openalex.org/keywords/permanent-magnet-synchronous-generator","display_name":"Permanent magnet synchronous generator","score":0.43215981125831604},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.431412011384964},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.3873938322067261},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.35294631123542786},{"id":"https://openalex.org/keywords/magnet","display_name":"Magnet","score":0.25187692046165466},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.22419047355651855},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.2021026313304901},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.10876736044883728},{"id":"https://openalex.org/keywords/induction-motor","display_name":"Induction motor","score":0.0884101390838623},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.05245959758758545}],"concepts":[{"id":"https://openalex.org/C2776529397","wikidata":"https://www.wikidata.org/wiki/Q190312","display_name":"Stator","level":2,"score":0.7376617193222046},{"id":"https://openalex.org/C144171764","wikidata":"https://www.wikidata.org/wiki/Q48103","display_name":"Torque","level":2,"score":0.7346243858337402},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6960464715957642},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.6521302461624146},{"id":"https://openalex.org/C2780992000","wikidata":"https://www.wikidata.org/wiki/Q17016113","display_name":"Generator (circuit theory)","level":3,"score":0.6230073571205139},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.6177803874015808},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5861955285072327},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5636254549026489},{"id":"https://openalex.org/C98716924","wikidata":"https://www.wikidata.org/wiki/Q752750","display_name":"Induction generator","level":3,"score":0.5571070313453674},{"id":"https://openalex.org/C2780023022","wikidata":"https://www.wikidata.org/wiki/Q1338171","display_name":"Compensation (psychology)","level":2,"score":0.5174289345741272},{"id":"https://openalex.org/C109871850","wikidata":"https://www.wikidata.org/wiki/Q1227571","display_name":"Direct torque control","level":4,"score":0.49375471472740173},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4788803458213806},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.4406081736087799},{"id":"https://openalex.org/C201320609","wikidata":"https://www.wikidata.org/wiki/Q3274420","display_name":"Permanent magnet synchronous generator","level":3,"score":0.43215981125831604},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.431412011384964},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3873938322067261},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.35294631123542786},{"id":"https://openalex.org/C16389437","wikidata":"https://www.wikidata.org/wiki/Q11421","display_name":"Magnet","level":2,"score":0.25187692046165466},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.22419047355651855},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2021026313304901},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.10876736044883728},{"id":"https://openalex.org/C80962145","wikidata":"https://www.wikidata.org/wiki/Q207450","display_name":"Induction motor","level":3,"score":0.0884101390838623},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.05245959758758545},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0},{"id":"https://openalex.org/C11171543","wikidata":"https://www.wikidata.org/wiki/Q41630","display_name":"Psychoanalysis","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C15744967","wikidata":"https://www.wikidata.org/wiki/Q9418","display_name":"Psychology","level":0,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tie.2017.2650870","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2017.2650870","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.9100000262260437,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":17,"referenced_works":["https://openalex.org/W627673027","https://openalex.org/W1536203303","https://openalex.org/W1973123163","https://openalex.org/W2031283715","https://openalex.org/W2040495112","https://openalex.org/W2073954532","https://openalex.org/W2074273695","https://openalex.org/W2074456052","https://openalex.org/W2135208119","https://openalex.org/W2135291726","https://openalex.org/W2142129448","https://openalex.org/W2145983081","https://openalex.org/W2158382319","https://openalex.org/W2395228928","https://openalex.org/W2514544098","https://openalex.org/W2539984436","https://openalex.org/W3217322655"],"related_works":["https://openalex.org/W631083485","https://openalex.org/W623794290","https://openalex.org/W4313452936","https://openalex.org/W2097026685","https://openalex.org/W2372255233","https://openalex.org/W2361693169","https://openalex.org/W2034890246","https://openalex.org/W2006720941","https://openalex.org/W379375666","https://openalex.org/W2949883251"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"a":[3,14,27,31,75,89,93,128],"control":[4,135,145],"solution":[5,22,73,136],"to":[6,26,126],"damp":[7],"the":[8,51,55,68,71,97,101,107,114,118,124,143,153,160],"torque":[9,99],"oscillations":[10],"that":[11],"appear":[12],"in":[13,74,150],"generator":[15,32,80],"during":[16],"an":[17],"unbalanced":[18],"stator":[19,103],"fault.":[20],"The":[21,42,86,133],"proposed":[23,72,134],"is":[24,36,45,121,131],"applicable":[25],"multichannel":[28,43],"configuration":[29],"where":[30],"with":[33,50,152],"several":[34],"stators":[35],"commanded":[37],"by":[38,47,82,104],"parallel-connected":[39],"power":[40],"converters.":[41,85],"structure":[44],"introduced":[46],"some":[48],"authors":[49],"goal":[52],"of":[53,57,70,100,116,142],"increasing":[54],"reliability":[56],"high-power":[58],"wind":[59],"turbines":[60],"cost":[61],"effectively.":[62],"Experimental":[63],"results":[64],"are":[65],"obtained":[66],"proving":[67],"effectiveness":[69],"nine-phase":[76],"permanent":[77],"magnet":[78],"synchronous":[79],"controlled":[81],"three":[83],"back-to-back":[84],"controller":[87,155],"shows":[88],"good":[90],"performance":[91],"and":[92,156],"rapid":[94],"response":[95],"canceling":[96],"pulsating":[98],"short-circuited":[102],"commanding":[105],"properly":[106],"remaining":[108],"healthy":[109],"stators.":[110],"In":[111],"this":[112],"way":[113],"risk":[115],"damaging":[117],"drive":[119],"train":[120],"minimized":[122],"while":[123],"ability":[125],"perform":[127],"safe":[129],"stop":[130],"guaranteed.":[132],"does":[137],"not":[138],"require":[139],"significant":[140],"modifications":[141],"existing":[144],"system":[146],"since":[147],"it":[148],"acts":[149],"parallel":[151],"regular":[154],"reacts":[157],"instantly":[158],"when":[159],"fault":[161],"triggers.":[162]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
