{"id":"https://openalex.org/W2331730087","doi":"https://doi.org/10.1109/tie.2016.2538201","title":"Fault-Tolerant Approach for Modular Multilevel Converters Under Submodule Faults","display_name":"Fault-Tolerant Approach for Modular Multilevel Converters Under Submodule Faults","publication_year":2016,"publication_date":"2016-03-03","ids":{"openalex":"https://openalex.org/W2331730087","doi":"https://doi.org/10.1109/tie.2016.2538201","mag":"2331730087"},"language":"en","primary_location":{"id":"doi:10.1109/tie.2016.2538201","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2016.2538201","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5055654426","display_name":"Fujin Deng","orcid":"https://orcid.org/0000-0002-9832-004X"},"institutions":[{"id":"https://openalex.org/I891191580","display_name":"Aalborg University","ror":"https://ror.org/04m5j1k67","country_code":"DK","type":"education","lineage":["https://openalex.org/I891191580"]}],"countries":["DK"],"is_corresponding":true,"raw_author_name":"Fujin Deng","raw_affiliation_strings":["Department of Energy Technology, Aalborg University, Aalborg, Denmark"],"affiliations":[{"raw_affiliation_string":"Department of Energy Technology, Aalborg University, Aalborg, Denmark","institution_ids":["https://openalex.org/I891191580"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5103148531","display_name":"Yanjun Tian","orcid":"https://orcid.org/0000-0002-3079-7343"},"institutions":[{"id":"https://openalex.org/I891191580","display_name":"Aalborg University","ror":"https://ror.org/04m5j1k67","country_code":"DK","type":"education","lineage":["https://openalex.org/I891191580"]}],"countries":["DK"],"is_corresponding":false,"raw_author_name":"Yanjun Tian","raw_affiliation_strings":["Department of Energy Technology, Aalborg University, Aalborg, Denmark"],"affiliations":[{"raw_affiliation_string":"Department of Energy Technology, Aalborg University, Aalborg, Denmark","institution_ids":["https://openalex.org/I891191580"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5068266522","display_name":"Rongwu Zhu","orcid":"https://orcid.org/0000-0002-8030-4738"},"institutions":[{"id":"https://openalex.org/I891191580","display_name":"Aalborg University","ror":"https://ror.org/04m5j1k67","country_code":"DK","type":"education","lineage":["https://openalex.org/I891191580"]}],"countries":["DK"],"is_corresponding":false,"raw_author_name":"Rongwu Zhu","raw_affiliation_strings":["Department of Energy Technology, Aalborg University, Aalborg, Denmark"],"affiliations":[{"raw_affiliation_string":"Department of Energy Technology, Aalborg University, Aalborg, Denmark","institution_ids":["https://openalex.org/I891191580"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100457678","display_name":"Zhe Chen","orcid":"https://orcid.org/0000-0002-2919-4481"},"institutions":[{"id":"https://openalex.org/I891191580","display_name":"Aalborg University","ror":"https://ror.org/04m5j1k67","country_code":"DK","type":"education","lineage":["https://openalex.org/I891191580"]}],"countries":["DK"],"is_corresponding":false,"raw_author_name":"Zhe Chen","raw_affiliation_strings":["Department of Energy Technology, Aalborg University, Aalborg, Denmark"],"affiliations":[{"raw_affiliation_string":"Department of Energy Technology, Aalborg University, Aalborg, Denmark","institution_ids":["https://openalex.org/I891191580"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5055654426"],"corresponding_institution_ids":["https://openalex.org/I891191580"],"apc_list":null,"apc_paid":null,"fwci":11.5736,"has_fulltext":false,"cited_by_count":151,"citation_normalized_percentile":{"value":0.9882763,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":96,"max":100},"biblio":{"volume":"63","issue":"11","first_page":"7253","last_page":"7263"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9531999826431274,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10361","display_name":"Silicon Carbide Semiconductor Technologies","score":0.9523000121116638,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.8429936170578003},{"id":"https://openalex.org/keywords/modular-design","display_name":"Modular design","score":0.7787387371063232},{"id":"https://openalex.org/keywords/fault-tolerance","display_name":"Fault tolerance","score":0.5672229528427124},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5423269271850586},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.4297299087047577},{"id":"https://openalex.org/keywords/parallel-computing","display_name":"Parallel computing","score":0.33652907609939575},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.27310577034950256},{"id":"https://openalex.org/keywords/programming-language","display_name":"Programming language","score":0.21885061264038086},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.21603867411613464},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.17430084943771362},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.1079632043838501}],"concepts":[{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.8429936170578003},{"id":"https://openalex.org/C101468663","wikidata":"https://www.wikidata.org/wiki/Q1620158","display_name":"Modular design","level":2,"score":0.7787387371063232},{"id":"https://openalex.org/C63540848","wikidata":"https://www.wikidata.org/wiki/Q3140932","display_name":"Fault tolerance","level":2,"score":0.5672229528427124},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5423269271850586},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4297299087047577},{"id":"https://openalex.org/C173608175","wikidata":"https://www.wikidata.org/wiki/Q232661","display_name":"Parallel computing","level":1,"score":0.33652907609939575},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.27310577034950256},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.21885061264038086},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.21603867411613464},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.17430084943771362},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.1079632043838501}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/tie.2016.2538201","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2016.2538201","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},{"id":"pmh:oai:pure.atira.dk:publications/e23e1703-3532-4436-b718-f7a0301607b3","is_oa":false,"landing_page_url":"https://vbn.aau.dk/da/publications/e23e1703-3532-4436-b718-f7a0301607b3","pdf_url":null,"source":{"id":"https://openalex.org/S4306401731","display_name":"VBN Forskningsportal (Aalborg Universitet)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I891191580","host_organization_name":"Aalborg University","host_organization_lineage":["https://openalex.org/I891191580"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Deng , F , Tian , Y , Zhu , R &amp; Chen , Z 2016 , ' Fault-Tolerant Approach for Modular Multilevel Converters under Submodule Faults ' , I E E E Transactions on Industrial Electronics , vol. 63 , no. 11 , pp. 7253 - 7263 . https://doi.org/10.1109/TIE.2016.2538201","raw_type":"article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":40,"referenced_works":["https://openalex.org/W1533204364","https://openalex.org/W1915388693","https://openalex.org/W1964350159","https://openalex.org/W1969526018","https://openalex.org/W1985469924","https://openalex.org/W1991440422","https://openalex.org/W1995673130","https://openalex.org/W2007244578","https://openalex.org/W2011113533","https://openalex.org/W2011975264","https://openalex.org/W2015547686","https://openalex.org/W2021871997","https://openalex.org/W2023285254","https://openalex.org/W2030899995","https://openalex.org/W2030973541","https://openalex.org/W2037239418","https://openalex.org/W2039233981","https://openalex.org/W2053515824","https://openalex.org/W2056370486","https://openalex.org/W2061146253","https://openalex.org/W2086647021","https://openalex.org/W2098642821","https://openalex.org/W2108449055","https://openalex.org/W2109665745","https://openalex.org/W2123746471","https://openalex.org/W2129242370","https://openalex.org/W2136509165","https://openalex.org/W2139772385","https://openalex.org/W2154211756","https://openalex.org/W2170998309","https://openalex.org/W2174980551","https://openalex.org/W2178160054","https://openalex.org/W2182278419","https://openalex.org/W2324474112","https://openalex.org/W2334341540","https://openalex.org/W2335086640","https://openalex.org/W6631675364","https://openalex.org/W6654474240","https://openalex.org/W6676313312","https://openalex.org/W6685827281"],"related_works":["https://openalex.org/W631083485","https://openalex.org/W4313452936","https://openalex.org/W2097026685","https://openalex.org/W2480068220","https://openalex.org/W2070883797","https://openalex.org/W4386859288","https://openalex.org/W2102542442","https://openalex.org/W1986220761","https://openalex.org/W2042495646","https://openalex.org/W2047506301"],"abstract_inverted_index":{"The":[0,25,50,119,140],"modular":[1],"multilevel":[2],"converter":[3],"(MMC)":[4],"is":[5,28,65,133],"attractive":[6],"for":[7,34,43],"medium-":[8],"or":[9],"high-power":[10],"applications":[11],"because":[12],"of":[13,16,30,52,60,99,102,146],"the":[14,31,35,44,53,69,71,77,89,97,100,106,117,124,137,144,147],"advantages":[15],"its":[17],"high":[18,22],"modularity,":[19],"availability,":[20],"and":[21,128],"power":[23],"quality.":[24],"fault-tolerant":[26,41],"operation":[27,79],"one":[29],"important":[32],"issues":[33],"MMC.":[36],"This":[37],"paper":[38],"proposed":[39,72,138,148],"a":[40,129],"approach":[42,73],"MMC":[45,54,78,90,131],"under":[46,63,82,92],"submodule":[47],"(SM)":[48],"faults.":[49,84],"characteristic":[51],"with":[55,123,136],"arms":[56],"containing":[57],"different":[58],"number":[59,101],"healthy":[61],"SMs":[62,104],"faults":[64,94],"analyzed.":[66],"Based":[67],"on":[68,111],"characteristic,":[70],"can":[74,86],"effectively":[75,87],"keep":[76],"as":[80],"normal":[81],"SM":[83,93],"It":[85],"improve":[88],"performance":[91],"but":[95],"without":[96,108],"knowledge":[98],"faulty":[103],"in":[105],"arm,":[107],"extra":[109],"demand":[110],"communication":[112],"systems,":[113],"which":[114],"potentially":[115],"increases":[116],"reliability.":[118],"time-domain":[120],"simulation":[121],"studies":[122],"PSCAD/EMTDC":[125],"are":[126],"conducted":[127],"down-scale":[130],"prototype":[132],"also":[134],"tested":[135],"approach.":[139,149],"study":[141],"results":[142],"show":[143],"effectiveness":[145]},"counts_by_year":[{"year":2025,"cited_by_count":10},{"year":2024,"cited_by_count":10},{"year":2023,"cited_by_count":22},{"year":2022,"cited_by_count":18},{"year":2021,"cited_by_count":14},{"year":2020,"cited_by_count":15},{"year":2019,"cited_by_count":22},{"year":2018,"cited_by_count":24},{"year":2017,"cited_by_count":13},{"year":2016,"cited_by_count":3}],"updated_date":"2026-04-04T16:13:02.066488","created_date":"2025-10-10T00:00:00"}
