{"id":"https://openalex.org/W2269710492","doi":"https://doi.org/10.1109/tie.2015.2494854","title":"The Comprehensive Design and Optimization of the Post-Fault Grid-Connected Three-Phase PWM Rectifier","display_name":"The Comprehensive Design and Optimization of the Post-Fault Grid-Connected Three-Phase PWM Rectifier","publication_year":2015,"publication_date":"2015-10-26","ids":{"openalex":"https://openalex.org/W2269710492","doi":"https://doi.org/10.1109/tie.2015.2494854","mag":"2269710492"},"language":"en","primary_location":{"id":"doi:10.1109/tie.2015.2494854","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2015.2494854","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5022214208","display_name":"Zhiyong Zeng","orcid":"https://orcid.org/0000-0002-4924-241X"},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhiyong Zeng","raw_affiliation_strings":["Coll. of Electr. Eng., Zhejiang Univ., Hangzhou, China","College of Electrical Engineering, Zhejiang University, Hangzhou, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Coll. of Electr. Eng., Zhejiang Univ., Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]},{"raw_affiliation_string":"College of Electrical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5074490550","display_name":"Weiyi Zheng","orcid":null},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Weiyi Zheng","raw_affiliation_strings":["Coll. of Electr. Eng., Zhejiang Univ., Hangzhou, China","College of Electrical Engineering, Zhejiang University, Hangzhou, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Coll. of Electr. Eng., Zhejiang Univ., Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]},{"raw_affiliation_string":"College of Electrical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5075147780","display_name":"Rongxiang Zhao","orcid":"https://orcid.org/0000-0002-9963-1149"},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Rongxiang Zhao","raw_affiliation_strings":["Coll. of Electr. Eng., Zhejiang Univ., Hangzhou, China","College of Electrical Engineering, Zhejiang University, Hangzhou, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Coll. of Electr. Eng., Zhejiang Univ., Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]},{"raw_affiliation_string":"College of Electrical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5034644518","display_name":"Chong Zhu","orcid":"https://orcid.org/0000-0002-6434-6006"},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Chong Zhu","raw_affiliation_strings":["Coll. of Electr. Eng., Zhejiang Univ., Hangzhou, China","College of Electrical Engineering, Zhejiang University, Hangzhou, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Coll. of Electr. Eng., Zhejiang Univ., Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]},{"raw_affiliation_string":"College of Electrical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5033635836","display_name":"Qingwei Yuan","orcid":null},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Qingwei Yuan","raw_affiliation_strings":["Coll. of Electr. Eng., Zhejiang Univ., Hangzhou, China","College of Electrical Engineering, Zhejiang University, Hangzhou, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Coll. of Electr. Eng., Zhejiang Univ., Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]},{"raw_affiliation_string":"College of Electrical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I76130692"],"apc_list":null,"apc_paid":null,"fwci":6.1351,"has_fulltext":false,"cited_by_count":42,"citation_normalized_percentile":{"value":0.96413954,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":95,"max":99},"biblio":{"volume":"63","issue":"3","first_page":"1629","last_page":"1642"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9980999827384949,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9980999827384949,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9977999925613403,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/overmodulation","display_name":"Overmodulation","score":0.781812846660614},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.7683346271514893},{"id":"https://openalex.org/keywords/pulse-width-modulation","display_name":"Pulse-width modulation","score":0.6382303833961487},{"id":"https://openalex.org/keywords/capacitor","display_name":"Capacitor","score":0.5779369473457336},{"id":"https://openalex.org/keywords/modulation","display_name":"Modulation (music)","score":0.4898659884929657},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.4856518507003784},{"id":"https://openalex.org/keywords/power-factor","display_name":"Power factor","score":0.45504581928253174},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.3986942768096924},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3986343741416931},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.39472103118896484},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.376945823431015},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.10208997130393982},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.07883521914482117},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.07183840870857239}],"concepts":[{"id":"https://openalex.org/C3099160","wikidata":"https://www.wikidata.org/wiki/Q7113825","display_name":"Overmodulation","level":4,"score":0.781812846660614},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.7683346271514893},{"id":"https://openalex.org/C92746544","wikidata":"https://www.wikidata.org/wiki/Q585184","display_name":"Pulse-width modulation","level":3,"score":0.6382303833961487},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.5779369473457336},{"id":"https://openalex.org/C123079801","wikidata":"https://www.wikidata.org/wiki/Q750240","display_name":"Modulation (music)","level":2,"score":0.4898659884929657},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.4856518507003784},{"id":"https://openalex.org/C64424096","wikidata":"https://www.wikidata.org/wiki/Q750454","display_name":"Power factor","level":3,"score":0.45504581928253174},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3986942768096924},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3986343741416931},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.39472103118896484},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.376945823431015},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.10208997130393982},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.07883521914482117},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.07183840870857239},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tie.2015.2494854","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2015.2494854","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":37,"referenced_works":["https://openalex.org/W1963843066","https://openalex.org/W1968701357","https://openalex.org/W1975478918","https://openalex.org/W1988757962","https://openalex.org/W1992850289","https://openalex.org/W2001262230","https://openalex.org/W2004798970","https://openalex.org/W2007918600","https://openalex.org/W2020032342","https://openalex.org/W2023285254","https://openalex.org/W2024684069","https://openalex.org/W2037266811","https://openalex.org/W2051969659","https://openalex.org/W2055909021","https://openalex.org/W2076863095","https://openalex.org/W2093533572","https://openalex.org/W2099499423","https://openalex.org/W2099883498","https://openalex.org/W2103577661","https://openalex.org/W2122714101","https://openalex.org/W2127554258","https://openalex.org/W2130061926","https://openalex.org/W2132628627","https://openalex.org/W2141359996","https://openalex.org/W2141645835","https://openalex.org/W2142351866","https://openalex.org/W2144081311","https://openalex.org/W2144899323","https://openalex.org/W2150763729","https://openalex.org/W2156740116","https://openalex.org/W2159767840","https://openalex.org/W2160897148","https://openalex.org/W2161021512","https://openalex.org/W2534451465","https://openalex.org/W2546250484","https://openalex.org/W4248350287","https://openalex.org/W6729454184"],"related_works":["https://openalex.org/W2140588266","https://openalex.org/W2347950446","https://openalex.org/W2168411361","https://openalex.org/W2169537318","https://openalex.org/W4245746364","https://openalex.org/W2037635004","https://openalex.org/W3121604558","https://openalex.org/W2070846476","https://openalex.org/W3113816069","https://openalex.org/W2390116128"],"abstract_inverted_index":{"The":[0,34,116,173],"comprehensive":[1,182],"design":[2,183],"and":[3,12,110,127,158,184,200],"optimization,":[4],"including":[5],"the":[6,23,27,37,43,50,53,56,63,74,78,83,91,99,106,123,128,131,135,143,149,160,171,177,180,193,196,201,211,215],"optimized":[7,64,84],"modulation":[8,31,40,65,85,155,203],"approach,":[9,66,86],"detailed":[10],"modeling,":[11],"reliable":[13],"control":[14],"algorithm,":[15],"is":[16,60,68,95,156,167],"presented":[17],"in":[18,214],"this":[19],"paper":[20],"to":[21,72,169],"guarantee":[22],"stable":[24],"operation":[25],"of":[26,36,69,77,130,148,179],"postfault":[28],"three-phase":[29],"pulsewidth":[30],"(PWM)":[32],"rectifier.":[33],"effects":[35],"space":[38],"vector":[39],"approaches":[41],"on":[42,49,98],"capacitor":[44,58,107,198],"current":[45,59,199],"are":[46,112],"investigated.":[47],"Based":[48],"analytical":[51],"results,":[52],"method":[54],"introducing":[55],"smaller":[57],"selected":[61,168],"as":[62],"which":[67],"paramount":[70],"importance":[71],"avoid":[73],"permanent":[75],"failure":[76],"dc-link":[79,197],"capacitors.":[80],"Then,":[81],"with":[82,142],"a":[87,163,187],"control-oriented":[88],"model":[89],"for":[90,153],"post-fault":[92,136,216],"PWM":[93],"rectifiers":[94,137],"derived":[96],"based":[97],"\u03b1":[100],"-":[101],"\u03b2":[102],"stationary":[103],"frame,":[104],"where":[105],"voltage":[108,152,166,213],"oscillation":[109],"deviation":[111],"taken":[113,206],"into":[114,207],"account.":[115],"proposed":[117,161,181],"model-based":[118],"controllers":[119],"do":[120],"not":[121],"require":[122],"phase-locked":[124],"loop":[125],"(PLL),":[126],"elimination":[129],"PLL":[132],"means":[133],"that":[134],"can":[138,189],"never":[139],"lose":[140],"synchronization":[141],"grid.":[144],"Furthermore,":[145],"an":[146],"equation":[147],"required":[150],"dc":[151,165,212],"linear":[154,202],"proposed,":[157],"using":[159],"equation,":[162],"correct":[164],"reject":[170],"overmodulation.":[172],"experimental":[174,194],"results":[175],"validate":[176],"effectiveness":[178],"optimization.":[185],"Finally,":[186],"conclusion":[188],"be":[190,205],"drawn":[191],"from":[192],"results-that":[195],"should":[204],"account":[208],"when":[209],"selecting":[210],"operation.":[217]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2023,"cited_by_count":3},{"year":2022,"cited_by_count":3},{"year":2021,"cited_by_count":3},{"year":2020,"cited_by_count":8},{"year":2019,"cited_by_count":5},{"year":2018,"cited_by_count":6},{"year":2017,"cited_by_count":8},{"year":2016,"cited_by_count":4}],"updated_date":"2026-06-26T08:34:08.712188","created_date":"2025-10-10T00:00:00"}
