{"id":"https://openalex.org/W1654411895","doi":"https://doi.org/10.1109/tie.2015.2437357","title":"Cost-Effective Three-Phase PMSM Drive Tolerant to Open-Phase Fault","display_name":"Cost-Effective Three-Phase PMSM Drive Tolerant to Open-Phase Fault","publication_year":2015,"publication_date":"2015-05-25","ids":{"openalex":"https://openalex.org/W1654411895","doi":"https://doi.org/10.1109/tie.2015.2437357","mag":"1654411895"},"language":"en","primary_location":{"id":"doi:10.1109/tie.2015.2437357","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2015.2437357","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5075243253","display_name":"Andra\u017e Kontar\u010dek","orcid":null},"institutions":[{"id":"https://openalex.org/I4210106063","display_name":"Hidria (Slovenia)","ror":"https://ror.org/00yycrh80","country_code":"SI","type":"company","lineage":["https://openalex.org/I4210106063"]}],"countries":["SI"],"is_corresponding":true,"raw_author_name":"Andraz Kontarcek","raw_affiliation_strings":["Hidria AET, Tolmin, Slovenia"],"affiliations":[{"raw_affiliation_string":"Hidria AET, Tolmin, Slovenia","institution_ids":["https://openalex.org/I4210106063"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5030812948","display_name":"P. Bajec","orcid":null},"institutions":[{"id":"https://openalex.org/I4210106063","display_name":"Hidria (Slovenia)","ror":"https://ror.org/00yycrh80","country_code":"SI","type":"company","lineage":["https://openalex.org/I4210106063"]}],"countries":["SI"],"is_corresponding":false,"raw_author_name":"Primoz Bajec","raw_affiliation_strings":["Hidria Rotomatika, Spodnja Idrija, Slovenia"],"affiliations":[{"raw_affiliation_string":"Hidria Rotomatika, Spodnja Idrija, Slovenia","institution_ids":["https://openalex.org/I4210106063"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5036433521","display_name":"Mitja Nemec","orcid":"https://orcid.org/0000-0002-8774-1025"},"institutions":[{"id":"https://openalex.org/I153976015","display_name":"University of Ljubljana","ror":"https://ror.org/05njb9z20","country_code":"SI","type":"education","lineage":["https://openalex.org/I153976015"]}],"countries":["SI"],"is_corresponding":false,"raw_author_name":"Mitja Nemec","raw_affiliation_strings":["Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, Slovenia","Fac. of Electr. Eng., Univ. of Ljubljana, Ljubljana, , Slovenia"],"affiliations":[{"raw_affiliation_string":"Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, Slovenia","institution_ids":["https://openalex.org/I153976015"]},{"raw_affiliation_string":"Fac. of Electr. Eng., Univ. of Ljubljana, Ljubljana, , Slovenia","institution_ids":["https://openalex.org/I153976015"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5071534204","display_name":"V. Ambro\u017ei\u010d","orcid":"https://orcid.org/0000-0002-3468-4581"},"institutions":[{"id":"https://openalex.org/I153976015","display_name":"University of Ljubljana","ror":"https://ror.org/05njb9z20","country_code":"SI","type":"education","lineage":["https://openalex.org/I153976015"]}],"countries":["SI"],"is_corresponding":false,"raw_author_name":"Vanja Ambrozic","raw_affiliation_strings":["Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, Slovenia","Fac. of Electr. Eng., Univ. of Ljubljana, Ljubljana, , Slovenia"],"affiliations":[{"raw_affiliation_string":"Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, Slovenia","institution_ids":["https://openalex.org/I153976015"]},{"raw_affiliation_string":"Fac. of Electr. Eng., Univ. of Ljubljana, Ljubljana, , Slovenia","institution_ids":["https://openalex.org/I153976015"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5079344660","display_name":"D. Nedeljkovic","orcid":"https://orcid.org/0000-0003-2429-3373"},"institutions":[{"id":"https://openalex.org/I153976015","display_name":"University of Ljubljana","ror":"https://ror.org/05njb9z20","country_code":"SI","type":"education","lineage":["https://openalex.org/I153976015"]}],"countries":["SI"],"is_corresponding":false,"raw_author_name":"David Nedeljkovic","raw_affiliation_strings":["Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, Slovenia","Fac. of Electr. Eng., Univ. of Ljubljana, Ljubljana, , Slovenia"],"affiliations":[{"raw_affiliation_string":"Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, Slovenia","institution_ids":["https://openalex.org/I153976015"]},{"raw_affiliation_string":"Fac. of Electr. Eng., Univ. of Ljubljana, Ljubljana, , Slovenia","institution_ids":["https://openalex.org/I153976015"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5075243253"],"corresponding_institution_ids":["https://openalex.org/I4210106063"],"apc_list":null,"apc_paid":null,"fwci":4.143,"has_fulltext":false,"cited_by_count":96,"citation_normalized_percentile":{"value":0.94274181,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":98,"max":100},"biblio":{"volume":"62","issue":"11","first_page":"6708","last_page":"6718"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.9973999857902527,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10504","display_name":"Sensorless Control of Electric Motors","score":0.9940000176429749,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/robustness","display_name":"Robustness (evolution)","score":0.6898068189620972},{"id":"https://openalex.org/keywords/fault-tolerance","display_name":"Fault tolerance","score":0.6681500673294067},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.6391001343727112},{"id":"https://openalex.org/keywords/stator","display_name":"Stator","score":0.6284826397895813},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.5770706534385681},{"id":"https://openalex.org/keywords/fault-indicator","display_name":"Fault indicator","score":0.5711715221405029},{"id":"https://openalex.org/keywords/torque","display_name":"Torque","score":0.5353819131851196},{"id":"https://openalex.org/keywords/stuck-at-fault","display_name":"Stuck-at fault","score":0.48597654700279236},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.446432501077652},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.43478164076805115},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.4290160536766052},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.3377954959869385},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.1896909475326538},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.0952211320400238},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.08767586946487427},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.07041680812835693}],"concepts":[{"id":"https://openalex.org/C63479239","wikidata":"https://www.wikidata.org/wiki/Q7353546","display_name":"Robustness (evolution)","level":3,"score":0.6898068189620972},{"id":"https://openalex.org/C63540848","wikidata":"https://www.wikidata.org/wiki/Q3140932","display_name":"Fault tolerance","level":2,"score":0.6681500673294067},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6391001343727112},{"id":"https://openalex.org/C2776529397","wikidata":"https://www.wikidata.org/wiki/Q190312","display_name":"Stator","level":2,"score":0.6284826397895813},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.5770706534385681},{"id":"https://openalex.org/C21267803","wikidata":"https://www.wikidata.org/wiki/Q5438159","display_name":"Fault indicator","level":4,"score":0.5711715221405029},{"id":"https://openalex.org/C144171764","wikidata":"https://www.wikidata.org/wiki/Q48103","display_name":"Torque","level":2,"score":0.5353819131851196},{"id":"https://openalex.org/C13625343","wikidata":"https://www.wikidata.org/wiki/Q7627418","display_name":"Stuck-at fault","level":4,"score":0.48597654700279236},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.446432501077652},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.43478164076805115},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.4290160536766052},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3377954959869385},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.1896909475326538},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0952211320400238},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.08767586946487427},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.07041680812835693},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C55493867","wikidata":"https://www.wikidata.org/wiki/Q7094","display_name":"Biochemistry","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C104317684","wikidata":"https://www.wikidata.org/wiki/Q7187","display_name":"Gene","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tie.2015.2437357","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2015.2437357","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.5899999737739563,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":27,"referenced_works":["https://openalex.org/W156884164","https://openalex.org/W1555319078","https://openalex.org/W1970115563","https://openalex.org/W1977010324","https://openalex.org/W1983638645","https://openalex.org/W1987912190","https://openalex.org/W2002267693","https://openalex.org/W2014526686","https://openalex.org/W2025255308","https://openalex.org/W2032232674","https://openalex.org/W2037007415","https://openalex.org/W2038938720","https://openalex.org/W2049532493","https://openalex.org/W2060623171","https://openalex.org/W2079590925","https://openalex.org/W2093244782","https://openalex.org/W2107463151","https://openalex.org/W2108361900","https://openalex.org/W2110186366","https://openalex.org/W2111175626","https://openalex.org/W2131789431","https://openalex.org/W2142351866","https://openalex.org/W2157436152","https://openalex.org/W2163656709","https://openalex.org/W2488793338","https://openalex.org/W4242089704","https://openalex.org/W6606306454"],"related_works":["https://openalex.org/W2544222762","https://openalex.org/W2575775159","https://openalex.org/W2577233154","https://openalex.org/W3186790058","https://openalex.org/W2350226881","https://openalex.org/W190707418","https://openalex.org/W2169757786","https://openalex.org/W2380803702","https://openalex.org/W2164489324","https://openalex.org/W2972711000"],"abstract_inverted_index":{"This":[0,101],"paper":[1],"presents":[2],"a":[3,12,68,86],"low-cost":[4],"fault-tolerant":[5,19,150],"system":[6,20],"for":[7,36,49,62,71],"open-phase":[8],"fault":[9,29,123,178],"(OPF)":[10],"in":[11,91,131],"power-converter-fed":[13],"permanent-magnet":[14],"synchronous":[15],"machine.":[16],"The":[17,51,121,142,177],"proposed":[18,52,122,149],"is":[21,39,54,77,89],"based":[22,55],"on":[23,56,117,138],"field":[24],"orientation":[25],"control":[26],"with":[27,42],"additional":[28],"tolerance":[30],"functionality.":[31],"A":[32],"current":[33,61],"predictive":[34],"method":[35,53,70],"OPF":[37],"detection":[38,124,179],"presented,":[40],"together":[41],"an":[43,139],"estimation":[44],"of":[45,59,74,82,98,147,161],"the":[46,57,63,75,83,95,104,114,148],"threshold":[47],"level":[48],"detection.":[50],"prediction":[58],"stator":[60],"next":[64],"sampling":[65],"interval.":[66],"Furthermore,":[67],"new":[69],"postfault":[72,107,126],"operation":[73,127],"machine":[76,119,162],"proposed.":[78],"For":[79],"optimal":[80],"performance":[81],"complete":[84],"drive,":[85],"prefiring":[87],"angle":[88],"introduced":[90],"order":[92],"to":[93],"avoid":[94],"temporary":[96],"generation":[97],"negative":[99],"torque.":[100],"improvement":[102],"increases":[103],"average":[105],"generated":[106],"electromagnetic":[108],"torque,":[109],"and":[110,125,133,167,187],"consequently,":[111],"it":[112,188],"reduces":[113],"mechanical":[115],"stress":[116],"various":[118],"parts.":[120],"solutions":[128],"were":[129,135],"simulated":[130],"MATLAB,":[132],"they":[134],"also":[136],"tested":[137],"experimental":[140],"setup.":[141],"results":[143],"show":[144],"several":[145],"advantages":[146],"solution,":[151],"like":[152],"its":[153],"short":[154],"fault-detection":[155],"time,":[156],"substantial":[157],"robustness":[158],"against":[159],"variation":[160],"parameters":[163],"or":[164],"load":[165],"fluctuations,":[166],"negligible":[168],"implementation":[169],"costs,":[170],"since":[171],"no":[172],"hardware":[173],"modifications":[174],"are":[175],"needed.":[176],"algorithm":[180],"does":[181],"not":[182],"require":[183],"high":[184],"computing":[185],"power,":[186],"operates":[189],"well":[190],"even":[191],"during":[192],"transients.":[193]},"counts_by_year":[{"year":2025,"cited_by_count":8},{"year":2024,"cited_by_count":12},{"year":2023,"cited_by_count":10},{"year":2022,"cited_by_count":12},{"year":2021,"cited_by_count":9},{"year":2020,"cited_by_count":10},{"year":2019,"cited_by_count":14},{"year":2018,"cited_by_count":6},{"year":2017,"cited_by_count":7},{"year":2016,"cited_by_count":8}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
