{"id":"https://openalex.org/W2068746480","doi":"https://doi.org/10.1109/tie.2014.2331011","title":"Soft-Switching AC-Link Three-Phase AC\u2013AC Buck\u2013Boost Converter","display_name":"Soft-Switching AC-Link Three-Phase AC\u2013AC Buck\u2013Boost Converter","publication_year":2014,"publication_date":"2014-06-19","ids":{"openalex":"https://openalex.org/W2068746480","doi":"https://doi.org/10.1109/tie.2014.2331011","mag":"2068746480"},"language":"en","primary_location":{"id":"doi:10.1109/tie.2014.2331011","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2014.2331011","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5076579091","display_name":"Mahshid Amirabadi","orcid":"https://orcid.org/0000-0001-5972-8221"},"institutions":[{"id":"https://openalex.org/I39422238","display_name":"University of Illinois Chicago","ror":"https://ror.org/02mpq6x41","country_code":"US","type":"education","lineage":["https://openalex.org/I39422238"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Mahshid Amirabadi","raw_affiliation_strings":["University of Illinois, Chicago, IL, USA","University of Illinois, Chicago, IL. USA"],"affiliations":[{"raw_affiliation_string":"University of Illinois, Chicago, IL, USA","institution_ids":["https://openalex.org/I39422238"]},{"raw_affiliation_string":"University of Illinois, Chicago, IL. USA","institution_ids":["https://openalex.org/I39422238"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5056218990","display_name":"Jeihoon Baek","orcid":"https://orcid.org/0000-0002-1186-3739"},"institutions":[{"id":"https://openalex.org/I4210161173","display_name":"Korea Railroad Research Institute","ror":"https://ror.org/04gzcxt97","country_code":"KR","type":"facility","lineage":["https://openalex.org/I2801339556","https://openalex.org/I4210144908","https://openalex.org/I4210161173","https://openalex.org/I4387152098"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Jeihoon Baek","raw_affiliation_strings":["Korea Railroad Research Institute, Uiwang, Korea","Korea Railroad Research Institute"],"affiliations":[{"raw_affiliation_string":"Korea Railroad Research Institute, Uiwang, Korea","institution_ids":["https://openalex.org/I4210161173"]},{"raw_affiliation_string":"Korea Railroad Research Institute","institution_ids":["https://openalex.org/I4210161173"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5066051337","display_name":"Hamid A. Toliyat","orcid":"https://orcid.org/0000-0002-0730-0677"},"institutions":[{"id":"https://openalex.org/I2801613365","display_name":"Mitchell Institute","ror":"https://ror.org/03ds72003","country_code":"US","type":"nonprofit","lineage":["https://openalex.org/I2801613365"]},{"id":"https://openalex.org/I91045830","display_name":"Texas A&M University","ror":"https://ror.org/01f5ytq51","country_code":"US","type":"education","lineage":["https://openalex.org/I91045830"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Hamid A. Toliyat","raw_affiliation_strings":["Texas A&M University, College Station, TX, USA","Texas A and. M University"],"affiliations":[{"raw_affiliation_string":"Texas A&M University, College Station, TX, USA","institution_ids":["https://openalex.org/I91045830"]},{"raw_affiliation_string":"Texas A and. M University","institution_ids":["https://openalex.org/I2801613365"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5109926296","display_name":"William C. Alexander","orcid":null},"institutions":[{"id":"https://openalex.org/I4210166090","display_name":"Ideal Power (United States)","ror":"https://ror.org/05re5hn81","country_code":"US","type":"company","lineage":["https://openalex.org/I4210166090"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"William C. Alexander","raw_affiliation_strings":["Ideal Power Converters Inc., Spicewood, TX, USA","Ideal Power Converters, Inc"],"affiliations":[{"raw_affiliation_string":"Ideal Power Converters Inc., Spicewood, TX, USA","institution_ids":["https://openalex.org/I4210166090"]},{"raw_affiliation_string":"Ideal Power Converters, Inc","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5076579091"],"corresponding_institution_ids":["https://openalex.org/I39422238"],"apc_list":null,"apc_paid":null,"fwci":3.768,"has_fulltext":false,"cited_by_count":65,"citation_normalized_percentile":{"value":0.93979927,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":"62","issue":"1","first_page":"3","last_page":"14"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10663","display_name":"Advanced Battery Technologies Research","score":0.9966999888420105,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/buck\u2013boost-converter","display_name":"Buck\u2013boost converter","score":0.78093421459198},{"id":"https://openalex.org/keywords/\u0107uk-converter","display_name":"\u0106uk converter","score":0.7679319381713867},{"id":"https://openalex.org/keywords/galvanic-isolation","display_name":"Galvanic isolation","score":0.7630296945571899},{"id":"https://openalex.org/keywords/boost-converter","display_name":"Boost converter","score":0.6967721581459045},{"id":"https://openalex.org/keywords/buck-converter","display_name":"Buck converter","score":0.6879172921180725},{"id":"https://openalex.org/keywords/forward-converter","display_name":"Forward converter","score":0.6642772555351257},{"id":"https://openalex.org/keywords/flyback-converter","display_name":"Flyback converter","score":0.6532651782035828},{"id":"https://openalex.org/keywords/inductor","display_name":"Inductor","score":0.5211924910545349},{"id":"https://openalex.org/keywords/capacitor","display_name":"Capacitor","score":0.5014157295227051},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.44351261854171753},{"id":"https://openalex.org/keywords/electrolytic-capacitor","display_name":"Electrolytic capacitor","score":0.4413753151893616},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.4323868453502655},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.37737035751342773},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.36616024374961853},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.32170113921165466},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.25821951031684875}],"concepts":[{"id":"https://openalex.org/C42043438","wikidata":"https://www.wikidata.org/wiki/Q1671740","display_name":"Buck\u2013boost converter","level":4,"score":0.78093421459198},{"id":"https://openalex.org/C100329506","wikidata":"https://www.wikidata.org/wiki/Q336439","display_name":"\u0106uk converter","level":4,"score":0.7679319381713867},{"id":"https://openalex.org/C70234604","wikidata":"https://www.wikidata.org/wiki/Q780813","display_name":"Galvanic isolation","level":4,"score":0.7630296945571899},{"id":"https://openalex.org/C78336795","wikidata":"https://www.wikidata.org/wiki/Q760134","display_name":"Boost converter","level":3,"score":0.6967721581459045},{"id":"https://openalex.org/C150818752","wikidata":"https://www.wikidata.org/wiki/Q83804","display_name":"Buck converter","level":3,"score":0.6879172921180725},{"id":"https://openalex.org/C55118286","wikidata":"https://www.wikidata.org/wiki/Q634739","display_name":"Forward converter","level":4,"score":0.6642772555351257},{"id":"https://openalex.org/C103303742","wikidata":"https://www.wikidata.org/wiki/Q1293595","display_name":"Flyback converter","level":4,"score":0.6532651782035828},{"id":"https://openalex.org/C144534570","wikidata":"https://www.wikidata.org/wiki/Q5325","display_name":"Inductor","level":3,"score":0.5211924910545349},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.5014157295227051},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.44351261854171753},{"id":"https://openalex.org/C79100374","wikidata":"https://www.wikidata.org/wiki/Q1326992","display_name":"Electrolytic capacitor","level":4,"score":0.4413753151893616},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4323868453502655},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.37737035751342773},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.36616024374961853},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.32170113921165466},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.25821951031684875}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tie.2014.2331011","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2014.2331011","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.9100000262260437}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":24,"referenced_works":["https://openalex.org/W1515608329","https://openalex.org/W1830123809","https://openalex.org/W1993277740","https://openalex.org/W2003147770","https://openalex.org/W2030973541","https://openalex.org/W2058104621","https://openalex.org/W2072823569","https://openalex.org/W2084706203","https://openalex.org/W2097847386","https://openalex.org/W2110323743","https://openalex.org/W2110497732","https://openalex.org/W2144226380","https://openalex.org/W2146572462","https://openalex.org/W2151571993","https://openalex.org/W2158332888","https://openalex.org/W2161091302","https://openalex.org/W2172856778","https://openalex.org/W2295580686","https://openalex.org/W2530787756","https://openalex.org/W3106329264","https://openalex.org/W4246552237","https://openalex.org/W4285719527","https://openalex.org/W6681331240","https://openalex.org/W6729074293"],"related_works":["https://openalex.org/W2783344684","https://openalex.org/W2061154986","https://openalex.org/W1497563151","https://openalex.org/W2588047361","https://openalex.org/W1539693063","https://openalex.org/W3008689990","https://openalex.org/W2501890988","https://openalex.org/W3214460120","https://openalex.org/W2126740233","https://openalex.org/W2971653998"],"abstract_inverted_index":{"In":[0,160,175],"this":[1,41,103,139,161,168,180,224,245,268,288,314],"paper,":[2,162],"the":[3,25,50,70,73,77,81,91,117,120,131,142,146,158,163,182,185,190,193,203,206,213,217,226,231,256,260,279,283,291,294,301,304,321,324,329,332],"soft-switching":[4,305],"ac-link":[5,306],"ac-ac":[6,307],"buck-boost":[7,27,39,308],"converter":[8,42,122,140,169,194,207,258,262,309,322],"will":[9,170,195,263,271,297,317,339],"be":[10,30,64,108,126,171,196,235,264,272,298,318,340],"studied":[11,172],"in":[12,20,102,173,201,267,287,313],"more":[13,127,277],"detail.":[14,174],"This":[15,79,198],"single-stage":[16],"converter,":[17,28,40,104,181],"which":[18,148],"is,":[19],"essence,":[21],"an":[22,31,97],"extension":[23],"of":[24,45,76,138,145,167,184,192,205,216,240,244,255,282,293,303,326],"dc-dc":[26],"can":[29,63,107],"excellent":[32],"alternative":[33],"to":[34,116,125,130,157,177],"dc-link":[35,133,261],"converters.":[36],"Being":[37],"a":[38,112,153],"is":[43,96,123,141,149,220,247,285,310],"capable":[44],"both":[46,58,328],"stepping-up":[47],"and":[48,55,60,72,90,165,230,251,331,336],"stepping-down":[49],"voltage.":[51,333],"The":[52,135,242],"link":[53,187,219,227,232],"current":[54,229,280],"voltage":[56],"are":[57],"alternating,":[59],"their":[61],"frequency":[62,233,330],"as":[65,67],"high":[66],"permitted":[68],"by":[69,110,151],"switches":[71,284],"sampling":[74],"time":[75,215],"microcontroller.":[78],"eliminates":[80],"need":[82],"for":[83],"dc":[84,87],"inductors":[85],"or":[86],"electrolytic":[88],"capacitors,":[89],"main":[92],"energy":[93],"storage":[94],"element":[95],"ac":[98],"inductor":[99],"(L).":[100],"Moreover,":[101,290],"galvanic":[105],"isolation":[106],"provided":[109],"adding":[111,152],"single-phase":[113],"high-frequency":[114],"transformer":[115],"link.":[118,159],"Therefore,":[119],"proposed":[121,257],"expected":[124],"compact":[128],"compared":[129],"conventional":[132],"converter.":[134,289],"other":[136],"advantage":[137],"soft":[143],"switching":[144],"switches,":[147,278],"feasible":[150],"small":[154],"capacitor":[155],"(C)":[156],"design":[164],"analysis":[166,199],"order":[176],"accurately":[178],"analyze":[179],"effect":[183],"LC":[186,218],"resonance":[188],"on":[189],"performance":[191,204,302],"studied.":[197],"helps":[200],"evaluating":[202],"at":[208,237],"low":[209],"power":[210],"levels":[211],"when":[212],"resonating":[214],"not":[221],"negligible.":[222],"Using":[223],"analysis,":[225],"peak":[228],"may":[234],"calculated":[236],"any":[238],"point":[239],"operation.":[241],"accuracy":[243],"method":[246],"verified":[248,341],"through":[249,342],"simulations":[250],"experiments.":[252,343],"Detailed":[253],"comparison":[254],"with":[259],"also":[265],"presented":[266],"paper.":[269,315],"It":[270,316],"shown":[273,319],"that,":[274],"despite":[275],"having":[276],"rating":[281],"lower":[286],"efficiencies":[292],"two":[295],"converters":[296],"compared.":[299],"Finally,":[300],"experimentally":[311],"evaluated":[312],"that":[320],"has":[323],"possibility":[325],"changing":[327],"Both":[334],"step-up":[335],"step-down":[337],"operations":[338]},"counts_by_year":[{"year":2025,"cited_by_count":4},{"year":2024,"cited_by_count":4},{"year":2023,"cited_by_count":6},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":9},{"year":2020,"cited_by_count":6},{"year":2019,"cited_by_count":5},{"year":2018,"cited_by_count":11},{"year":2017,"cited_by_count":6},{"year":2016,"cited_by_count":8},{"year":2015,"cited_by_count":3},{"year":2014,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
