{"id":"https://openalex.org/W1996388890","doi":"https://doi.org/10.1109/tie.2013.2290752","title":"Flexible Arrangement of Static Converters for Grid-Connected Wind Energy Conversion Systems","display_name":"Flexible Arrangement of Static Converters for Grid-Connected Wind Energy Conversion Systems","publication_year":2013,"publication_date":"2013-11-19","ids":{"openalex":"https://openalex.org/W1996388890","doi":"https://doi.org/10.1109/tie.2013.2290752","mag":"1996388890"},"language":"en","primary_location":{"id":"doi:10.1109/tie.2013.2290752","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2013.2290752","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5050654271","display_name":"Felipe B. Grigoletto","orcid":"https://orcid.org/0000-0002-1583-3836"},"institutions":[{"id":"https://openalex.org/I72872986","display_name":"Universidade Federal do Pampa","ror":"https://ror.org/003qt4p19","country_code":"BR","type":"education","lineage":["https://openalex.org/I72872986"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Felipe Bovolini Grigoletto","raw_affiliation_strings":["Electronic Systems Research Group (GPSEl), Federal University of Pampa (UNIPAMPA), Alegrete-RS, Brazil","Electron. Syst. Res. Group (GPSEl), Fed. Univ. of Pampa (UNIPAMPA), Alegrete, Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electronic Systems Research Group (GPSEl), Federal University of Pampa (UNIPAMPA), Alegrete-RS, Brazil","institution_ids":["https://openalex.org/I72872986"]},{"raw_affiliation_string":"Electron. Syst. Res. Group (GPSEl), Fed. Univ. of Pampa (UNIPAMPA), Alegrete, Brazil","institution_ids":["https://openalex.org/I72872986"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5088988804","display_name":"Humberto Pinheiro","orcid":"https://orcid.org/0000-0002-5225-6126"},"institutions":[{"id":"https://openalex.org/I33501960","display_name":"Universidade Federal de Santa Maria","ror":"https://ror.org/01b78mz79","country_code":"BR","type":"education","lineage":["https://openalex.org/I33501960"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Humberto Pinheiro","raw_affiliation_strings":["Department of Electrical Energy Conversion (DPEE), Federal University of Santa Maria (UFSM), Santa Maria-RS, Brazil","Dept. of Electr. Energy Conversion (DPEE), Fed. Univ. of Santa Maria (UFSM), Santa Maria, Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Energy Conversion (DPEE), Federal University of Santa Maria (UFSM), Santa Maria-RS, Brazil","institution_ids":["https://openalex.org/I33501960"]},{"raw_affiliation_string":"Dept. of Electr. Energy Conversion (DPEE), Fed. Univ. of Santa Maria (UFSM), Santa Maria, Brazil","institution_ids":["https://openalex.org/I33501960"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":4.5812,"has_fulltext":false,"cited_by_count":17,"citation_normalized_percentile":{"value":0.94198056,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":"61","issue":"9","first_page":"4707","last_page":"4721"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.7396674752235413},{"id":"https://openalex.org/keywords/wind-power","display_name":"Wind power","score":0.57647305727005},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.5673893690109253},{"id":"https://openalex.org/keywords/control-reconfiguration","display_name":"Control reconfiguration","score":0.5643773078918457},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.5478054285049438},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.494260311126709},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4803291857242584},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.47179073095321655},{"id":"https://openalex.org/keywords/harmonic","display_name":"Harmonic","score":0.43916240334510803},{"id":"https://openalex.org/keywords/three-phase","display_name":"Three-phase","score":0.43355751037597656},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.41796964406967163},{"id":"https://openalex.org/keywords/generator","display_name":"Generator (circuit theory)","score":0.41614702343940735},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.40697845816612244},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.40436869859695435},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.38088423013687134},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.35992398858070374},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.10079991817474365},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.07732692360877991}],"concepts":[{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.7396674752235413},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.57647305727005},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.5673893690109253},{"id":"https://openalex.org/C119701452","wikidata":"https://www.wikidata.org/wiki/Q5165881","display_name":"Control reconfiguration","level":2,"score":0.5643773078918457},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5478054285049438},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.494260311126709},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4803291857242584},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.47179073095321655},{"id":"https://openalex.org/C127934551","wikidata":"https://www.wikidata.org/wiki/Q1148098","display_name":"Harmonic","level":2,"score":0.43916240334510803},{"id":"https://openalex.org/C173871940","wikidata":"https://www.wikidata.org/wiki/Q471846","display_name":"Three-phase","level":3,"score":0.43355751037597656},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.41796964406967163},{"id":"https://openalex.org/C2780992000","wikidata":"https://www.wikidata.org/wiki/Q17016113","display_name":"Generator (circuit theory)","level":3,"score":0.41614702343940735},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.40697845816612244},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.40436869859695435},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.38088423013687134},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.35992398858070374},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.10079991817474365},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.07732692360877991},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tie.2013.2290752","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2013.2290752","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.9100000262260437}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":34,"referenced_works":["https://openalex.org/W1409615047","https://openalex.org/W1535774741","https://openalex.org/W1537381581","https://openalex.org/W1749872184","https://openalex.org/W1763243278","https://openalex.org/W1974259851","https://openalex.org/W1978597091","https://openalex.org/W1987163194","https://openalex.org/W2006246155","https://openalex.org/W2011196341","https://openalex.org/W2056736267","https://openalex.org/W2073306308","https://openalex.org/W2078871156","https://openalex.org/W2086507824","https://openalex.org/W2096548501","https://openalex.org/W2102406524","https://openalex.org/W2117435717","https://openalex.org/W2123477187","https://openalex.org/W2126580932","https://openalex.org/W2132755931","https://openalex.org/W2137263702","https://openalex.org/W2138604071","https://openalex.org/W2139047115","https://openalex.org/W2146058304","https://openalex.org/W2151212761","https://openalex.org/W2151327366","https://openalex.org/W2154636565","https://openalex.org/W2155899223","https://openalex.org/W2159170500","https://openalex.org/W2165183557","https://openalex.org/W2170163303","https://openalex.org/W2540003577","https://openalex.org/W2569978589","https://openalex.org/W3211807550"],"related_works":["https://openalex.org/W2371999781","https://openalex.org/W2079861066","https://openalex.org/W4381547739","https://openalex.org/W1551156272","https://openalex.org/W2312997963","https://openalex.org/W2359931330","https://openalex.org/W2047412911","https://openalex.org/W2051965053","https://openalex.org/W2384696981","https://openalex.org/W4205117978"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"a":[3,70],"new":[4],"flexible":[5,37],"arrangement":[6,19,38],"of":[7,34,73,80,105],"static":[8],"converters":[9],"for":[10],"grid-connected":[11],"wind":[12,54],"energy":[13],"conversion":[14],"systems":[15],"(WECS).":[16],"The":[17,31],"proposed":[18,36,107],"uses":[20],"three-phase":[21],"voltage-fed":[22],"back-to-back":[23],"mass-produced":[24],"power":[25,45,59],"converter":[26],"modules":[27],"with":[28],"reconfiguration":[29],"switches.":[30],"main":[32],"features":[33],"the":[35,57,74,81,95,100,106],"are":[39,89],"as":[40,77,79],"follows:":[41],"1)":[42],"expanded":[43],"reactive":[44],"capability":[46],"limits;":[47],"2)":[48],"high":[49],"efficiency,":[50],"mainly":[51],"under":[52],"low":[53,64],"conditions":[55],"where":[56],"active":[58],"is":[60],"reduced;":[61],"and":[62,84,98,103],"3)":[63],"current":[65,86],"harmonic":[66],"content.":[67],"In":[68],"addition,":[69],"detailed":[71],"description":[72],"operating":[75],"modes,":[76],"well":[78],"grid,":[82],"generator,":[83],"circulating":[85],"controller":[87],"design,":[88],"given.":[90],"Finally,":[91],"experimental":[92],"results":[93],"support":[94],"theoretical":[96],"development,":[97],"demonstrate":[99],"good":[101],"performance":[102],"flexibility":[104],"arrangement.":[108]},"counts_by_year":[{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2018,"cited_by_count":4},{"year":2017,"cited_by_count":2},{"year":2016,"cited_by_count":7},{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
