{"id":"https://openalex.org/W2012856026","doi":"https://doi.org/10.1109/tie.2013.2274417","title":"Loss Definition of Electric Drives by a Calorimetric System With Data Processing","display_name":"Loss Definition of Electric Drives by a Calorimetric System With Data Processing","publication_year":2013,"publication_date":"2013-07-24","ids":{"openalex":"https://openalex.org/W2012856026","doi":"https://doi.org/10.1109/tie.2013.2274417","mag":"2012856026"},"language":"en","primary_location":{"id":"doi:10.1109/tie.2013.2274417","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2013.2274417","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5084978887","display_name":"Antti Kosonen","orcid":"https://orcid.org/0000-0003-0656-8310"},"institutions":[{"id":"https://openalex.org/I63548447","display_name":"Lappeenranta-Lahti University of Technology","ror":"https://ror.org/0208vgz68","country_code":"FI","type":"education","lineage":["https://openalex.org/I63548447"]}],"countries":["FI"],"is_corresponding":true,"raw_author_name":"Antti Kosonen","raw_affiliation_strings":["Department of Electrical Engineering, Lappeenranta University of Technology (LUT), Lappeenranta, Finland","Dept. of Electr. Eng., Lappeenranta Univ. of Technol. (LUT), Lappeenranta, Finland"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Lappeenranta University of Technology (LUT), Lappeenranta, Finland","institution_ids":["https://openalex.org/I63548447"]},{"raw_affiliation_string":"Dept. of Electr. Eng., Lappeenranta Univ. of Technol. (LUT), Lappeenranta, Finland","institution_ids":["https://openalex.org/I63548447"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5062415262","display_name":"Lassi Aarniovuori","orcid":"https://orcid.org/0000-0001-9082-0413"},"institutions":[{"id":"https://openalex.org/I63548447","display_name":"Lappeenranta-Lahti University of Technology","ror":"https://ror.org/0208vgz68","country_code":"FI","type":"education","lineage":["https://openalex.org/I63548447"]}],"countries":["FI"],"is_corresponding":false,"raw_author_name":"Lassi Aarniovuori","raw_affiliation_strings":["Department of Electrical Engineering, Lappeenranta University of Technology (LUT), Lappeenranta, Finland","Dept. of Electr. Eng., Lappeenranta Univ. of Technol. (LUT), Lappeenranta, Finland"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Lappeenranta University of Technology (LUT), Lappeenranta, Finland","institution_ids":["https://openalex.org/I63548447"]},{"raw_affiliation_string":"Dept. of Electr. Eng., Lappeenranta Univ. of Technol. (LUT), Lappeenranta, Finland","institution_ids":["https://openalex.org/I63548447"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5019986727","display_name":"Jero Ahola","orcid":"https://orcid.org/0000-0003-1082-8023"},"institutions":[{"id":"https://openalex.org/I63548447","display_name":"Lappeenranta-Lahti University of Technology","ror":"https://ror.org/0208vgz68","country_code":"FI","type":"education","lineage":["https://openalex.org/I63548447"]}],"countries":["FI"],"is_corresponding":false,"raw_author_name":"Jero Ahola","raw_affiliation_strings":["Department of Electrical Engineering, Lappeenranta University of Technology (LUT), Lappeenranta, Finland","Dept. of Electr. Eng., Lappeenranta Univ. of Technol. (LUT), Lappeenranta, Finland"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Lappeenranta University of Technology (LUT), Lappeenranta, Finland","institution_ids":["https://openalex.org/I63548447"]},{"raw_affiliation_string":"Dept. of Electr. Eng., Lappeenranta Univ. of Technol. (LUT), Lappeenranta, Finland","institution_ids":["https://openalex.org/I63548447"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5069863777","display_name":"Jari Backman","orcid":"https://orcid.org/0000-0001-7593-6581"},"institutions":[{"id":"https://openalex.org/I63548447","display_name":"Lappeenranta-Lahti University of Technology","ror":"https://ror.org/0208vgz68","country_code":"FI","type":"education","lineage":["https://openalex.org/I63548447"]}],"countries":["FI"],"is_corresponding":false,"raw_author_name":"Jari Backman","raw_affiliation_strings":["Department of Energy Engineering, Lappeenranta University of Technology (LUT), Lappeenranta, Finland","[Department of Energy Engineering, Lappeenranta University of Technology (LUT), Lappeenranta, Finland]"],"affiliations":[{"raw_affiliation_string":"Department of Energy Engineering, Lappeenranta University of Technology (LUT), Lappeenranta, Finland","institution_ids":["https://openalex.org/I63548447"]},{"raw_affiliation_string":"[Department of Energy Engineering, Lappeenranta University of Technology (LUT), Lappeenranta, Finland]","institution_ids":["https://openalex.org/I63548447"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5003778700","display_name":"Juha Pyrh\u00f6nen","orcid":"https://orcid.org/0000-0001-6704-1315"},"institutions":[{"id":"https://openalex.org/I63548447","display_name":"Lappeenranta-Lahti University of Technology","ror":"https://ror.org/0208vgz68","country_code":"FI","type":"education","lineage":["https://openalex.org/I63548447"]}],"countries":["FI"],"is_corresponding":false,"raw_author_name":"Juha Pyrhonen","raw_affiliation_strings":["Department of Electrical Engineering, Lappeenranta University of Technology (LUT), Lappeenranta, Finland","Dept. of Electr. Eng., Lappeenranta Univ. of Technol. (LUT), Lappeenranta, Finland"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Lappeenranta University of Technology (LUT), Lappeenranta, Finland","institution_ids":["https://openalex.org/I63548447"]},{"raw_affiliation_string":"Dept. of Electr. Eng., Lappeenranta Univ. of Technol. (LUT), Lappeenranta, Finland","institution_ids":["https://openalex.org/I63548447"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5014987200","display_name":"Markku Niemel\u00e4","orcid":"https://orcid.org/0000-0002-9359-245X"},"institutions":[{"id":"https://openalex.org/I63548447","display_name":"Lappeenranta-Lahti University of Technology","ror":"https://ror.org/0208vgz68","country_code":"FI","type":"education","lineage":["https://openalex.org/I63548447"]}],"countries":["FI"],"is_corresponding":false,"raw_author_name":"Markku Niemela","raw_affiliation_strings":["Department of Electrical Engineering, Lappeenranta University of Technology (LUT), Lappeenranta, Finland","Dept. of Electr. Eng., Lappeenranta Univ. of Technol. (LUT), Lappeenranta, Finland"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Lappeenranta University of Technology (LUT), Lappeenranta, Finland","institution_ids":["https://openalex.org/I63548447"]},{"raw_affiliation_string":"Dept. of Electr. Eng., Lappeenranta Univ. of Technol. (LUT), Lappeenranta, Finland","institution_ids":["https://openalex.org/I63548447"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":6,"corresponding_author_ids":["https://openalex.org/A5084978887"],"corresponding_institution_ids":["https://openalex.org/I63548447"],"apc_list":null,"apc_paid":null,"fwci":3.0738,"has_fulltext":false,"cited_by_count":31,"citation_normalized_percentile":{"value":0.91843006,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":"61","issue":"8","first_page":"4432","last_page":"4442"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.9973999857902527,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.9973999857902527,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10998","display_name":"Heat Transfer and Optimization","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.995199978351593,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/calorimeter","display_name":"Calorimeter (particle physics)","score":0.7616996765136719},{"id":"https://openalex.org/keywords/measurement-uncertainty","display_name":"Measurement uncertainty","score":0.6836456060409546},{"id":"https://openalex.org/keywords/repeatability","display_name":"Repeatability","score":0.6326823234558105},{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.5529546737670898},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4915846288204193},{"id":"https://openalex.org/keywords/observational-error","display_name":"Observational error","score":0.47721511125564575},{"id":"https://openalex.org/keywords/range","display_name":"Range (aeronautics)","score":0.4691905975341797},{"id":"https://openalex.org/keywords/electric-motor","display_name":"Electric motor","score":0.4649800956249237},{"id":"https://openalex.org/keywords/temperature-measurement","display_name":"Temperature measurement","score":0.45934444665908813},{"id":"https://openalex.org/keywords/electric-power","display_name":"Electric power","score":0.43963387608528137},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.3565182089805603},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.3547835946083069},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3477492928504944},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.34180498123168945},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.2982102632522583},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.2839205861091614},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2717456817626953},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.11272954940795898},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.09589609503746033},{"id":"https://openalex.org/keywords/thermodynamics","display_name":"Thermodynamics","score":0.08462002873420715}],"concepts":[{"id":"https://openalex.org/C18073261","wikidata":"https://www.wikidata.org/wiki/Q1722586","display_name":"Calorimeter (particle physics)","level":3,"score":0.7616996765136719},{"id":"https://openalex.org/C137209882","wikidata":"https://www.wikidata.org/wiki/Q1403517","display_name":"Measurement uncertainty","level":2,"score":0.6836456060409546},{"id":"https://openalex.org/C154020017","wikidata":"https://www.wikidata.org/wiki/Q520171","display_name":"Repeatability","level":2,"score":0.6326823234558105},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.5529546737670898},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4915846288204193},{"id":"https://openalex.org/C19619285","wikidata":"https://www.wikidata.org/wiki/Q196372","display_name":"Observational error","level":2,"score":0.47721511125564575},{"id":"https://openalex.org/C204323151","wikidata":"https://www.wikidata.org/wiki/Q905424","display_name":"Range (aeronautics)","level":2,"score":0.4691905975341797},{"id":"https://openalex.org/C176871988","wikidata":"https://www.wikidata.org/wiki/Q72313","display_name":"Electric motor","level":2,"score":0.4649800956249237},{"id":"https://openalex.org/C72293138","wikidata":"https://www.wikidata.org/wiki/Q909741","display_name":"Temperature measurement","level":2,"score":0.45934444665908813},{"id":"https://openalex.org/C40293303","wikidata":"https://www.wikidata.org/wiki/Q27137","display_name":"Electric power","level":3,"score":0.43963387608528137},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3565182089805603},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3547835946083069},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3477492928504944},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.34180498123168945},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.2982102632522583},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.2839205861091614},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2717456817626953},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.11272954940795898},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.09589609503746033},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.08462002873420715},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C94915269","wikidata":"https://www.wikidata.org/wiki/Q1834857","display_name":"Detector","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tie.2013.2274417","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2013.2274417","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.9100000262260437,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":19,"referenced_works":["https://openalex.org/W1592622566","https://openalex.org/W1966749103","https://openalex.org/W1968193198","https://openalex.org/W1968743101","https://openalex.org/W1998436840","https://openalex.org/W2006713512","https://openalex.org/W2008687536","https://openalex.org/W2026517895","https://openalex.org/W2026692071","https://openalex.org/W2034896222","https://openalex.org/W2059885728","https://openalex.org/W2063216900","https://openalex.org/W2083885475","https://openalex.org/W2119285331","https://openalex.org/W2139503821","https://openalex.org/W2153718477","https://openalex.org/W2164226910","https://openalex.org/W2164240552","https://openalex.org/W2169469786"],"related_works":["https://openalex.org/W2220451197","https://openalex.org/W2370122455","https://openalex.org/W4284698423","https://openalex.org/W1600397729","https://openalex.org/W2360832559","https://openalex.org/W1989588780","https://openalex.org/W2386418312","https://openalex.org/W2388364071","https://openalex.org/W2810429778","https://openalex.org/W2379668504"],"abstract_inverted_index":{"An":[0],"accurate":[1],"measurement":[2,35,80,96,140,145,148],"of":[3,8,68,150,184],"power":[4,61,67],"or":[5,89],"heat":[6,33,45,53,135],"losses":[7,24,46,136,183],"high-efficiency":[9],"electrical":[10],"devices":[11,186],"is":[12,42,100,155],"difficult":[13],"with":[14,37,64,179],"input":[15],"and":[16,73,129,142,168,193],"output":[17],"powers.":[18],"In":[19,28],"the":[20,65,95,108,126,139,144,151,176,191],"calorimetric":[21,153,194],"method,":[22],"these":[23,185],"are":[25,114,159,173,187],"measured":[26,134,174,188],"directly.":[27],"this":[29],"paper,":[30],"a":[31,52,85,90,118,122,130,164],"functional":[32],"loss":[34,54],"concept":[36,99,154],"adequate":[38],"data":[39,112],"processing":[40,113],"methods":[41],"suggested":[43],"for":[44,163],"up":[47,69,75],"to":[48,59,70,76,102,107,124,132,137],"2":[49],"kW.":[50,78],"Such":[51],"range":[55],"can":[56],"be":[57],"applied":[58],"present-day":[60],"electronic":[62],"converters":[63],"rated":[66],"110":[71],"kW":[72],"motors":[74],"37":[77],"The":[79,98,147,182],"system":[81],"does":[82],"not":[83],"require":[84],"complex":[86],"mechanical":[87],"structure":[88],"large":[91],"footprint":[92],"area":[93],"on":[94],"site.":[97],"scalable":[101],"different":[103],"sizes.":[104],"New":[105],"features":[106],"balance":[109],"type":[110],"calorimeter":[111],"introduced.":[115],"These":[116,172],"include":[117],"mass":[119],"flow":[120],"correction,":[121],"technique":[123],"detect":[125],"thermal":[127],"equilibrium,":[128],"method":[131],"correct":[133],"improve":[138],"repeatability":[141],"reduce":[143],"uncertainty.":[146],"uncertainty":[149],"proposed":[152],"0.4%.":[156],"Laboratory":[157],"measurements":[158],"carried":[160],"out":[161],"both":[162,189],"commercial":[165],"frequency":[166],"converter":[167],"an":[169],"electric":[170],"motor.":[171],"at":[175],"same":[177],"time":[178],"two":[180],"calorimeters.":[181],"by":[190],"input-output":[192],"methods.":[195]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":3},{"year":2018,"cited_by_count":2},{"year":2017,"cited_by_count":4},{"year":2016,"cited_by_count":5},{"year":2015,"cited_by_count":2},{"year":2014,"cited_by_count":6}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
