{"id":"https://openalex.org/W1988031053","doi":"https://doi.org/10.1109/tie.2012.2232256","title":"A Novel Integrated Buck\u2013Flyback Nonisolated PFC Converter With High Power Factor","display_name":"A Novel Integrated Buck\u2013Flyback Nonisolated PFC Converter With High Power Factor","publication_year":2012,"publication_date":"2012-12-08","ids":{"openalex":"https://openalex.org/W1988031053","doi":"https://doi.org/10.1109/tie.2012.2232256","mag":"1988031053"},"language":"en","primary_location":{"id":"doi:10.1109/tie.2012.2232256","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2012.2232256","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101958162","display_name":"Xiaogao Xie","orcid":"https://orcid.org/0000-0003-3466-3841"},"institutions":[{"id":"https://openalex.org/I50760025","display_name":"Hangzhou Dianzi University","ror":"https://ror.org/0576gt767","country_code":"CN","type":"education","lineage":["https://openalex.org/I50760025"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Xiaogao Xie","raw_affiliation_strings":["College of Automation, Hangzhou Dianzi University, Hangzhou, China","[College of Automation, Hangzhou Dianzi University, Hangzhou, China]"],"affiliations":[{"raw_affiliation_string":"College of Automation, Hangzhou Dianzi University, Hangzhou, China","institution_ids":["https://openalex.org/I50760025"]},{"raw_affiliation_string":"[College of Automation, Hangzhou Dianzi University, Hangzhou, China]","institution_ids":["https://openalex.org/I50760025"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101463824","display_name":"Chen Zhao","orcid":"https://orcid.org/0000-0002-4903-0337"},"institutions":[{"id":"https://openalex.org/I50760025","display_name":"Hangzhou Dianzi University","ror":"https://ror.org/0576gt767","country_code":"CN","type":"education","lineage":["https://openalex.org/I50760025"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Chen Zhao","raw_affiliation_strings":["College of Automation, Hangzhou Dianzi University, Hangzhou, China","[College of Automation, Hangzhou Dianzi University, Hangzhou, China]"],"affiliations":[{"raw_affiliation_string":"College of Automation, Hangzhou Dianzi University, Hangzhou, China","institution_ids":["https://openalex.org/I50760025"]},{"raw_affiliation_string":"[College of Automation, Hangzhou Dianzi University, Hangzhou, China]","institution_ids":["https://openalex.org/I50760025"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5037748023","display_name":"Qiang Lu","orcid":"https://orcid.org/0000-0002-1586-5598"},"institutions":[{"id":"https://openalex.org/I50760025","display_name":"Hangzhou Dianzi University","ror":"https://ror.org/0576gt767","country_code":"CN","type":"education","lineage":["https://openalex.org/I50760025"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Qiang Lu","raw_affiliation_strings":["College of Automation, Hangzhou Dianzi University, Hangzhou, China","[College of Automation, Hangzhou Dianzi University, Hangzhou, China]"],"affiliations":[{"raw_affiliation_string":"College of Automation, Hangzhou Dianzi University, Hangzhou, China","institution_ids":["https://openalex.org/I50760025"]},{"raw_affiliation_string":"[College of Automation, Hangzhou Dianzi University, Hangzhou, China]","institution_ids":["https://openalex.org/I50760025"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100672364","display_name":"Shirong Liu","orcid":"https://orcid.org/0000-0002-8357-3116"},"institutions":[{"id":"https://openalex.org/I50760025","display_name":"Hangzhou Dianzi University","ror":"https://ror.org/0576gt767","country_code":"CN","type":"education","lineage":["https://openalex.org/I50760025"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Shirong Liu","raw_affiliation_strings":["College of Automation, Hangzhou Dianzi University, Hangzhou, China","[College of Automation, Hangzhou Dianzi University, Hangzhou, China]"],"affiliations":[{"raw_affiliation_string":"College of Automation, Hangzhou Dianzi University, Hangzhou, China","institution_ids":["https://openalex.org/I50760025"]},{"raw_affiliation_string":"[College of Automation, Hangzhou Dianzi University, Hangzhou, China]","institution_ids":["https://openalex.org/I50760025"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5101958162"],"corresponding_institution_ids":["https://openalex.org/I50760025"],"apc_list":null,"apc_paid":null,"fwci":3.6826,"has_fulltext":false,"cited_by_count":66,"citation_normalized_percentile":{"value":0.93246012,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":94,"max":99},"biblio":{"volume":"60","issue":"12","first_page":"5603","last_page":"5612"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10361","display_name":"Silicon Carbide Semiconductor Technologies","score":0.9966999888420105,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9955999851226807,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/flyback-converter","display_name":"Flyback converter","score":0.8870208859443665},{"id":"https://openalex.org/keywords/buck\u2013boost-converter","display_name":"Buck\u2013boost converter","score":0.8197651505470276},{"id":"https://openalex.org/keywords/buck-converter","display_name":"Buck converter","score":0.817870020866394},{"id":"https://openalex.org/keywords/flyback-transformer","display_name":"Flyback transformer","score":0.7164602279663086},{"id":"https://openalex.org/keywords/\u0107uk-converter","display_name":"\u0106uk converter","score":0.6559472680091858},{"id":"https://openalex.org/keywords/forward-converter","display_name":"Forward converter","score":0.5335970520973206},{"id":"https://openalex.org/keywords/flyback-diode","display_name":"Flyback diode","score":0.502208948135376},{"id":"https://openalex.org/keywords/power-factor","display_name":"Power factor","score":0.4432958662509918},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.3965785801410675},{"id":"https://openalex.org/keywords/boost-converter","display_name":"Boost converter","score":0.39210405945777893},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.36076194047927856},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.34812772274017334},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.32701796293258667},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.3237053155899048},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.27799469232559204},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.07200855016708374}],"concepts":[{"id":"https://openalex.org/C103303742","wikidata":"https://www.wikidata.org/wiki/Q1293595","display_name":"Flyback converter","level":4,"score":0.8870208859443665},{"id":"https://openalex.org/C42043438","wikidata":"https://www.wikidata.org/wiki/Q1671740","display_name":"Buck\u2013boost converter","level":4,"score":0.8197651505470276},{"id":"https://openalex.org/C150818752","wikidata":"https://www.wikidata.org/wiki/Q83804","display_name":"Buck converter","level":3,"score":0.817870020866394},{"id":"https://openalex.org/C17321440","wikidata":"https://www.wikidata.org/wiki/Q184909","display_name":"Flyback transformer","level":4,"score":0.7164602279663086},{"id":"https://openalex.org/C100329506","wikidata":"https://www.wikidata.org/wiki/Q336439","display_name":"\u0106uk converter","level":4,"score":0.6559472680091858},{"id":"https://openalex.org/C55118286","wikidata":"https://www.wikidata.org/wiki/Q634739","display_name":"Forward converter","level":4,"score":0.5335970520973206},{"id":"https://openalex.org/C166869088","wikidata":"https://www.wikidata.org/wiki/Q888791","display_name":"Flyback diode","level":5,"score":0.502208948135376},{"id":"https://openalex.org/C64424096","wikidata":"https://www.wikidata.org/wiki/Q750454","display_name":"Power factor","level":3,"score":0.4432958662509918},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.3965785801410675},{"id":"https://openalex.org/C78336795","wikidata":"https://www.wikidata.org/wiki/Q760134","display_name":"Boost converter","level":3,"score":0.39210405945777893},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.36076194047927856},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.34812772274017334},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.32701796293258667},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3237053155899048},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.27799469232559204},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.07200855016708374},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tie.2012.2232256","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2012.2232256","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.8500000238418579,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":28,"referenced_works":["https://openalex.org/W1997575928","https://openalex.org/W2014068408","https://openalex.org/W2043743208","https://openalex.org/W2074221214","https://openalex.org/W2097214191","https://openalex.org/W2103895901","https://openalex.org/W2106882473","https://openalex.org/W2108911666","https://openalex.org/W2115941796","https://openalex.org/W2117998562","https://openalex.org/W2123704305","https://openalex.org/W2126110552","https://openalex.org/W2131375744","https://openalex.org/W2136423090","https://openalex.org/W2143552116","https://openalex.org/W2145090033","https://openalex.org/W2149643249","https://openalex.org/W2150385210","https://openalex.org/W2151662729","https://openalex.org/W2151848653","https://openalex.org/W2152722208","https://openalex.org/W2155343337","https://openalex.org/W2155653368","https://openalex.org/W2158692815","https://openalex.org/W2164940598","https://openalex.org/W2535654461","https://openalex.org/W3139607144","https://openalex.org/W3152324742"],"related_works":["https://openalex.org/W1709769460","https://openalex.org/W2274754534","https://openalex.org/W4323891767","https://openalex.org/W2061154986","https://openalex.org/W2155014956","https://openalex.org/W2392412651","https://openalex.org/W2361442082","https://openalex.org/W2389366188","https://openalex.org/W1970535043","https://openalex.org/W1914259762"],"abstract_inverted_index":{"A":[0,126],"novel":[1],"integrated":[2,74,140],"buck-flyback":[3,75,141],"nonisolated":[4,76,142],"power":[5],"factor":[6],"(PF)":[7],"correction":[8],"(PFC)":[9],"converter":[10,18,26,68,78,106],"is":[11,19,46,107],"proposed":[12,73,105,139],"in":[13,33,64],"this":[14,55],"paper.":[15],"This":[16],"new":[17],"an":[20],"inherent":[21],"integration":[22],"of":[23,60,103,137],"a":[24,28],"buck":[25,38,66,115],"and":[27,88,120],"flyback":[29,35],"converter,":[30],"which":[31],"operates":[32],"either":[34],"mode":[36,39],"or":[37,48],"according":[40],"to":[41,112,132],"whether":[42],"the":[43,51,57,72,96,104,113,134,138],"input":[44,62,86,90],"voltage":[45],"lower":[47],"higher":[49],"than":[50],"output":[52],"voltage.":[53],"In":[54],"way,":[56],"dead":[58],"zones":[59],"ac":[61,85],"current":[63,91],"traditional":[65],"PFC":[67,77,143],"are":[69,124],"eliminated.":[70],"Therefore,":[71],"can":[79,93],"achieve":[80],"high":[81],"PF":[82],"under":[83],"universal":[84],"range,":[87],"its":[89],"harmonics":[92],"easily":[94],"meet":[95],"IEC61000-3-2":[97],"Class":[98],"C":[99],"limits.":[100],"The":[101],"efficiency":[102],"not":[108],"deteriorated":[109],"obviously":[110],"compared":[111],"conventional":[114],"converter.":[116,144],"Detailed":[117],"theoretical":[118,135],"analysis":[119,136],"optimal":[121],"design":[122],"considerations":[123],"presented.":[125],"100-W":[127],"prototype":[128],"was":[129],"built":[130],"up":[131],"verify":[133]},"counts_by_year":[{"year":2025,"cited_by_count":4},{"year":2024,"cited_by_count":5},{"year":2023,"cited_by_count":4},{"year":2022,"cited_by_count":3},{"year":2021,"cited_by_count":3},{"year":2020,"cited_by_count":7},{"year":2019,"cited_by_count":6},{"year":2018,"cited_by_count":8},{"year":2017,"cited_by_count":5},{"year":2016,"cited_by_count":6},{"year":2015,"cited_by_count":6},{"year":2014,"cited_by_count":7},{"year":2013,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
