{"id":"https://openalex.org/W2125229331","doi":"https://doi.org/10.1109/tie.2012.2216239","title":"A Novel Distributed Direct-Voltage Control Strategy for Grid Integration of Offshore Wind Energy Systems Through MTDC Network","display_name":"A Novel Distributed Direct-Voltage Control Strategy for Grid Integration of Offshore Wind Energy Systems Through MTDC Network","publication_year":2012,"publication_date":"2012-08-29","ids":{"openalex":"https://openalex.org/W2125229331","doi":"https://doi.org/10.1109/tie.2012.2216239","mag":"2125229331"},"language":"en","primary_location":{"id":"doi:10.1109/tie.2012.2216239","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2012.2216239","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5009055310","display_name":"R. Teixeira Pinto","orcid":"https://orcid.org/0000-0001-7692-868X"},"institutions":[{"id":"https://openalex.org/I98358874","display_name":"Delft University of Technology","ror":"https://ror.org/02e2c7k09","country_code":"NL","type":"education","lineage":["https://openalex.org/I98358874"]}],"countries":["NL"],"is_corresponding":true,"raw_author_name":"Rodrigo Teixeira Pinto","raw_affiliation_strings":["Power Processing Group (EPP), Delft University of Technology, Delft, Netherlands"],"affiliations":[{"raw_affiliation_string":"Power Processing Group (EPP), Delft University of Technology, Delft, Netherlands","institution_ids":["https://openalex.org/I98358874"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5052336847","display_name":"Pavol Bauer","orcid":"https://orcid.org/0000-0002-1171-9972"},"institutions":[{"id":"https://openalex.org/I98358874","display_name":"Delft University of Technology","ror":"https://ror.org/02e2c7k09","country_code":"NL","type":"education","lineage":["https://openalex.org/I98358874"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Pavol Bauer","raw_affiliation_strings":["Power Processing Group (EPP), Delft University of Technology, Delft, Netherlands","Power Process. Group (EPP), Delft Univ. of Technol., Delft, Netherlands"],"affiliations":[{"raw_affiliation_string":"Power Processing Group (EPP), Delft University of Technology, Delft, Netherlands","institution_ids":["https://openalex.org/I98358874"]},{"raw_affiliation_string":"Power Process. Group (EPP), Delft Univ. of Technol., Delft, Netherlands","institution_ids":["https://openalex.org/I98358874"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5109345521","display_name":"S. Rodrigues","orcid":null},"institutions":[{"id":"https://openalex.org/I98358874","display_name":"Delft University of Technology","ror":"https://ror.org/02e2c7k09","country_code":"NL","type":"education","lineage":["https://openalex.org/I98358874"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"S\u00edlvio F. Rodrigues","raw_affiliation_strings":["Power Processing Group (EPP), Delft University of Technology, Delft, Netherlands","Power Process. Group (EPP), Delft Univ. of Technol., Delft, Netherlands"],"affiliations":[{"raw_affiliation_string":"Power Processing Group (EPP), Delft University of Technology, Delft, Netherlands","institution_ids":["https://openalex.org/I98358874"]},{"raw_affiliation_string":"Power Process. Group (EPP), Delft Univ. of Technol., Delft, Netherlands","institution_ids":["https://openalex.org/I98358874"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5067235233","display_name":"E.J. Wiggelinkhuizen","orcid":null},"institutions":[{"id":"https://openalex.org/I2802259095","display_name":"Energy Research Centre of the Netherlands","ror":"https://ror.org/04xa4c474","country_code":"NL","type":"facility","lineage":["https://openalex.org/I2802259095"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Edwin Jan Wiggelinkhuizen","raw_affiliation_strings":["Energy Research Centre of the Netherlands, Petten, Netherlands","Energy Research Center of the Netherlands, Petten, Netherlands"],"affiliations":[{"raw_affiliation_string":"Energy Research Centre of the Netherlands, Petten, Netherlands","institution_ids":["https://openalex.org/I2802259095"]},{"raw_affiliation_string":"Energy Research Center of the Netherlands, Petten, Netherlands","institution_ids":["https://openalex.org/I2802259095"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5082907926","display_name":"J. Pierik","orcid":null},"institutions":[{"id":"https://openalex.org/I2802259095","display_name":"Energy Research Centre of the Netherlands","ror":"https://ror.org/04xa4c474","country_code":"NL","type":"facility","lineage":["https://openalex.org/I2802259095"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Jan Pierik","raw_affiliation_strings":["Energy Research Centre of the Netherlands, Petten, Netherlands","Energy Research Center of the Netherlands, Petten, Netherlands"],"affiliations":[{"raw_affiliation_string":"Energy Research Centre of the Netherlands, Petten, Netherlands","institution_ids":["https://openalex.org/I2802259095"]},{"raw_affiliation_string":"Energy Research Center of the Netherlands, Petten, Netherlands","institution_ids":["https://openalex.org/I2802259095"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5023154586","display_name":"Braham Ferreira","orcid":"https://orcid.org/0000-0001-5445-4743"},"institutions":[{"id":"https://openalex.org/I98358874","display_name":"Delft University of Technology","ror":"https://ror.org/02e2c7k09","country_code":"NL","type":"education","lineage":["https://openalex.org/I98358874"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Braham Ferreira","raw_affiliation_strings":["Power Processing Group (EPP), Delft University of Technology, Delft, Netherlands","Power Process. Group (EPP), Delft Univ. of Technol., Delft, Netherlands"],"affiliations":[{"raw_affiliation_string":"Power Processing Group (EPP), Delft University of Technology, Delft, Netherlands","institution_ids":["https://openalex.org/I98358874"]},{"raw_affiliation_string":"Power Process. Group (EPP), Delft Univ. of Technol., Delft, Netherlands","institution_ids":["https://openalex.org/I98358874"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":6,"corresponding_author_ids":["https://openalex.org/A5009055310"],"corresponding_institution_ids":["https://openalex.org/I98358874"],"apc_list":null,"apc_paid":null,"fwci":15.9577,"has_fulltext":false,"cited_by_count":217,"citation_normalized_percentile":{"value":0.99368275,"is_in_top_1_percent":true,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":100},"biblio":{"volume":"60","issue":"6","first_page":"2429","last_page":"2441"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9944000244140625,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12277","display_name":"Frequency Control in Power Systems","score":0.9440000057220459,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/offshore-wind-power","display_name":"Offshore wind power","score":0.78171706199646},{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.5927630662918091},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.567682683467865},{"id":"https://openalex.org/keywords/wind-power","display_name":"Wind power","score":0.5489740967750549},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.5463791489601135},{"id":"https://openalex.org/keywords/high-voltage-direct-current","display_name":"High-voltage direct current","score":0.510115921497345},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.48014897108078003},{"id":"https://openalex.org/keywords/transmission-system","display_name":"Transmission system","score":0.4612269699573517},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.438857764005661},{"id":"https://openalex.org/keywords/transmission","display_name":"Transmission (telecommunications)","score":0.4238811433315277},{"id":"https://openalex.org/keywords/operating-point","display_name":"Operating point","score":0.41712820529937744},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.38134175539016724},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.33940714597702026},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.33240818977355957},{"id":"https://openalex.org/keywords/direct-current","display_name":"Direct current","score":0.1560460925102234}],"concepts":[{"id":"https://openalex.org/C8735168","wikidata":"https://www.wikidata.org/wiki/Q61637704","display_name":"Offshore wind power","level":3,"score":0.78171706199646},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.5927630662918091},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.567682683467865},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.5489740967750549},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.5463791489601135},{"id":"https://openalex.org/C2781163877","wikidata":"https://www.wikidata.org/wiki/Q370607","display_name":"High-voltage direct current","level":4,"score":0.510115921497345},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.48014897108078003},{"id":"https://openalex.org/C113608303","wikidata":"https://www.wikidata.org/wiki/Q1056835","display_name":"Transmission system","level":3,"score":0.4612269699573517},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.438857764005661},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.4238811433315277},{"id":"https://openalex.org/C22762622","wikidata":"https://www.wikidata.org/wiki/Q628904","display_name":"Operating point","level":2,"score":0.41712820529937744},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.38134175539016724},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.33940714597702026},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.33240818977355957},{"id":"https://openalex.org/C2776620479","wikidata":"https://www.wikidata.org/wiki/Q159241","display_name":"Direct current","level":3,"score":0.1560460925102234},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tie.2012.2216239","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2012.2216239","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8600000143051147,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":59,"referenced_works":["https://openalex.org/W562646189","https://openalex.org/W568414233","https://openalex.org/W653693514","https://openalex.org/W1489229909","https://openalex.org/W1501333049","https://openalex.org/W1533936327","https://openalex.org/W1571642121","https://openalex.org/W1915509411","https://openalex.org/W1989581855","https://openalex.org/W1993163066","https://openalex.org/W2002159486","https://openalex.org/W2002522387","https://openalex.org/W2008613628","https://openalex.org/W2010101405","https://openalex.org/W2017737565","https://openalex.org/W2042464758","https://openalex.org/W2045174480","https://openalex.org/W2070923681","https://openalex.org/W2072738774","https://openalex.org/W2073887634","https://openalex.org/W2088285481","https://openalex.org/W2097463082","https://openalex.org/W2100648055","https://openalex.org/W2103601587","https://openalex.org/W2110263331","https://openalex.org/W2112242185","https://openalex.org/W2119470727","https://openalex.org/W2120308393","https://openalex.org/W2128126917","https://openalex.org/W2129502301","https://openalex.org/W2134501454","https://openalex.org/W2140075756","https://openalex.org/W2142672517","https://openalex.org/W2143903258","https://openalex.org/W2144384311","https://openalex.org/W2160496229","https://openalex.org/W2162535598","https://openalex.org/W2163501722","https://openalex.org/W2164981794","https://openalex.org/W2167527617","https://openalex.org/W2167836251","https://openalex.org/W2168753575","https://openalex.org/W2503761200","https://openalex.org/W2540951881","https://openalex.org/W2543463584","https://openalex.org/W2545285971","https://openalex.org/W2547385080","https://openalex.org/W2588415315","https://openalex.org/W2609540675","https://openalex.org/W3106461780","https://openalex.org/W3145097763","https://openalex.org/W4210681472","https://openalex.org/W4231693478","https://openalex.org/W6621678019","https://openalex.org/W6630126330","https://openalex.org/W6647735968","https://openalex.org/W6652619593","https://openalex.org/W6678967520","https://openalex.org/W6733897659"],"related_works":["https://openalex.org/W4360995733","https://openalex.org/W3111442364","https://openalex.org/W2803052951","https://openalex.org/W2945179158","https://openalex.org/W3023774549","https://openalex.org/W2347414024","https://openalex.org/W1992197998","https://openalex.org/W2314915483","https://openalex.org/W2372919208","https://openalex.org/W4385734551"],"abstract_inverted_index":{"Although":[0],"HVDC":[1],"transmission":[2,55],"systems":[3],"have":[4,40],"been":[5],"available":[6,144],"since":[7,120],"mid-1950s,":[8],"almost":[9],"all":[10],"installations":[11],"worldwide":[12],"are":[13,118,185],"point-to-point":[14],"systems.":[15,98],"In":[16],"the":[17,19,42,59,62,80,85,126,130,139,189,192],"past,":[18],"lower":[20],"reliability":[21],"and":[22,33,87,141],"higher":[23],"costs":[24],"of":[25,44,51,64,68,79,89,94,108,132,138,143,160,191],"power":[26,164],"electronic":[27],"converters,":[28],"together":[29],"with":[30],"complex":[31],"controls":[32],"need":[34],"for":[35,54,66,92,116,129],"fast":[36],"telecommunication":[37],"links,":[38],"may":[39],"prevented":[41],"construction":[43],"multiterminal":[45],"DC":[46,145,162],"(MTDC)":[47],"networks.":[48,110],"The":[49,76,111,166],"introduction":[50],"voltage-source":[52],"converters":[53],"purposes":[56],"has":[57],"renewed":[58],"interest":[60],"in":[61,178],"development":[63,131],"supergrids":[65],"integration":[67,93],"remote":[69],"renewable":[70],"sources,":[71],"such":[72],"as":[73,125],"offshore":[74,95],"wind.":[75],"main":[77],"focus":[78],"present":[81],"work":[82],"is":[83,122,172],"on":[84],"control":[86,114,147,152,169],"operation":[88],"MTDC":[90,109,180],"networks":[91],"wind":[96],"energy":[97],"After":[99],"a":[100,106,136,150,161],"brief":[101],"introduction,":[102],"this":[103],"paper":[104],"proposes":[105],"classification":[107],"most":[112],"utilized":[113],"structures":[115],"VSC-HVDC":[117],"presented,":[119],"it":[121],"currently":[123],"recognized":[124],"best":[127],"candidate":[128],"supergrids,":[133],"followed":[134],"by":[135,158,175],"discussion":[137],"merits":[140],"shortcomings":[142],"voltage":[146,168],"methods.":[148],"Subsequently,":[149],"novel":[151],"strategy\u2014with":[153],"distributed":[154,167],"slack":[155],"nodes\u2014is":[156],"proposed":[157],"means":[159],"optimal":[163],"flow.":[165],"(DVC)":[170],"strategy":[171],"numerically":[173],"illustrated":[174],"loss":[176],"minimization":[177],"an":[179],"network.":[181],"Finally,":[182],"dynamic":[183],"simulations":[184],"performed":[186],"to":[187],"demonstrate":[188],"benefits":[190],"DVC":[193],"strategy.":[194]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":6},{"year":2023,"cited_by_count":11},{"year":2022,"cited_by_count":12},{"year":2021,"cited_by_count":10},{"year":2020,"cited_by_count":18},{"year":2019,"cited_by_count":24},{"year":2018,"cited_by_count":28},{"year":2017,"cited_by_count":19},{"year":2016,"cited_by_count":22},{"year":2015,"cited_by_count":31},{"year":2014,"cited_by_count":24},{"year":2013,"cited_by_count":9},{"year":2012,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
