{"id":"https://openalex.org/W2109283950","doi":"https://doi.org/10.1109/tie.2012.2205354","title":"An LVRT Control Strategy Based on Flux Linkage Tracking for DFIG-Based WECS","display_name":"An LVRT Control Strategy Based on Flux Linkage Tracking for DFIG-Based WECS","publication_year":2012,"publication_date":"2012-07-11","ids":{"openalex":"https://openalex.org/W2109283950","doi":"https://doi.org/10.1109/tie.2012.2205354","mag":"2109283950"},"language":"en","primary_location":{"id":"doi:10.1109/tie.2012.2205354","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2012.2205354","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100670804","display_name":"Shuai Xiao","orcid":"https://orcid.org/0000-0002-7314-705X"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Shuai Xiao","raw_affiliation_strings":["Department of Automation, Tsinghua University, Beijing, China","Department of Automation, Tsinghua University, Beijing (China)"],"affiliations":[{"raw_affiliation_string":"Department of Automation, Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]},{"raw_affiliation_string":"Department of Automation, Tsinghua University, Beijing (China)","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100751396","display_name":"Geng Yang","orcid":"https://orcid.org/0000-0002-9296-5664"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Geng Yang","raw_affiliation_strings":["Department of Automation, Tsinghua University, Beijing, China","Department of Automation, Tsinghua University, Beijing (China)"],"affiliations":[{"raw_affiliation_string":"Department of Automation, Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]},{"raw_affiliation_string":"Department of Automation, Tsinghua University, Beijing (China)","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5110246831","display_name":"Honglin Zhou","orcid":null},"institutions":[{"id":"https://openalex.org/I4210091069","display_name":"Dongfang Electric Corporation (China)","ror":"https://ror.org/00az85j53","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210091069"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Honglin Zhou","raw_affiliation_strings":["Research and Development Center, Dongfang Electric Corporation, Chengdu, China","R&DCenter, Dongfang Electr. Corp., Chengdu, China"],"affiliations":[{"raw_affiliation_string":"Research and Development Center, Dongfang Electric Corporation, Chengdu, China","institution_ids":["https://openalex.org/I4210091069"]},{"raw_affiliation_string":"R&DCenter, Dongfang Electr. Corp., Chengdu, China","institution_ids":["https://openalex.org/I4210091069"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5002397251","display_name":"Hua Geng","orcid":"https://orcid.org/0000-0002-8336-6731"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Hua Geng","raw_affiliation_strings":["Department of Automation, Tsinghua University, Beijing, China","Department of Automation, Tsinghua University, Beijing (China)"],"affiliations":[{"raw_affiliation_string":"Department of Automation, Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]},{"raw_affiliation_string":"Department of Automation, Tsinghua University, Beijing (China)","institution_ids":["https://openalex.org/I99065089"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5100670804"],"corresponding_institution_ids":["https://openalex.org/I99065089"],"apc_list":null,"apc_paid":null,"fwci":15.9718,"has_fulltext":false,"cited_by_count":249,"citation_normalized_percentile":{"value":0.99366865,"is_in_top_1_percent":true,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":100},"biblio":{"volume":"60","issue":"7","first_page":"2820","last_page":"2832"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9968000054359436,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9962999820709229,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/flux-linkage","display_name":"Flux linkage","score":0.8918801546096802},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.8097493648529053},{"id":"https://openalex.org/keywords/stator","display_name":"Stator","score":0.6976704597473145},{"id":"https://openalex.org/keywords/rotor","display_name":"Rotor (electric)","score":0.6534299850463867},{"id":"https://openalex.org/keywords/chromatin-structure-remodeling-complex","display_name":"Chromatin structure remodeling (RSC) complex","score":0.5666239857673645},{"id":"https://openalex.org/keywords/low-voltage-ride-through","display_name":"Low voltage ride through","score":0.5426249504089355},{"id":"https://openalex.org/keywords/doubly-fed-electric-machine","display_name":"Doubly fed electric machine","score":0.4982292652130127},{"id":"https://openalex.org/keywords/wind-power","display_name":"Wind power","score":0.47634652256965637},{"id":"https://openalex.org/keywords/linkage","display_name":"Linkage (software)","score":0.45511606335639954},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.42891374230384827},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.40202340483665466},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.35836732387542725},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.3340336084365845},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.22223889827728271},{"id":"https://openalex.org/keywords/direct-torque-control","display_name":"Direct torque control","score":0.1434866487979889},{"id":"https://openalex.org/keywords/induction-motor","display_name":"Induction motor","score":0.11171332001686096}],"concepts":[{"id":"https://openalex.org/C155343825","wikidata":"https://www.wikidata.org/wiki/Q4374882","display_name":"Flux linkage","level":5,"score":0.8918801546096802},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.8097493648529053},{"id":"https://openalex.org/C2776529397","wikidata":"https://www.wikidata.org/wiki/Q190312","display_name":"Stator","level":2,"score":0.6976704597473145},{"id":"https://openalex.org/C17281054","wikidata":"https://www.wikidata.org/wiki/Q193466","display_name":"Rotor (electric)","level":2,"score":0.6534299850463867},{"id":"https://openalex.org/C14519417","wikidata":"https://www.wikidata.org/wiki/Q5113740","display_name":"Chromatin structure remodeling (RSC) complex","level":5,"score":0.5666239857673645},{"id":"https://openalex.org/C2780438294","wikidata":"https://www.wikidata.org/wiki/Q6693052","display_name":"Low voltage ride through","level":4,"score":0.5426249504089355},{"id":"https://openalex.org/C200971846","wikidata":"https://www.wikidata.org/wiki/Q1420518","display_name":"Doubly fed electric machine","level":4,"score":0.4982292652130127},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.47634652256965637},{"id":"https://openalex.org/C31266012","wikidata":"https://www.wikidata.org/wiki/Q6554340","display_name":"Linkage (software)","level":3,"score":0.45511606335639954},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.42891374230384827},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.40202340483665466},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.35836732387542725},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3340336084365845},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.22223889827728271},{"id":"https://openalex.org/C109871850","wikidata":"https://www.wikidata.org/wiki/Q1227571","display_name":"Direct torque control","level":4,"score":0.1434866487979889},{"id":"https://openalex.org/C80962145","wikidata":"https://www.wikidata.org/wiki/Q207450","display_name":"Induction motor","level":3,"score":0.11171332001686096},{"id":"https://openalex.org/C64927066","wikidata":"https://www.wikidata.org/wiki/Q36293","display_name":"Histone","level":3,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C55493867","wikidata":"https://www.wikidata.org/wiki/Q7094","display_name":"Biochemistry","level":1,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C84772758","wikidata":"https://www.wikidata.org/wiki/Q271794","display_name":"Nucleosome","level":4,"score":0.0},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.0},{"id":"https://openalex.org/C104317684","wikidata":"https://www.wikidata.org/wiki/Q7187","display_name":"Gene","level":2,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tie.2012.2205354","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2012.2205354","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.8999999761581421,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":35,"referenced_works":["https://openalex.org/W1486343125","https://openalex.org/W1973462041","https://openalex.org/W1979577828","https://openalex.org/W2011579856","https://openalex.org/W2060947992","https://openalex.org/W2096429242","https://openalex.org/W2097340349","https://openalex.org/W2100267072","https://openalex.org/W2101401941","https://openalex.org/W2105024249","https://openalex.org/W2105885590","https://openalex.org/W2106077014","https://openalex.org/W2110263331","https://openalex.org/W2114718058","https://openalex.org/W2116398790","https://openalex.org/W2125552290","https://openalex.org/W2132308115","https://openalex.org/W2134746661","https://openalex.org/W2136512037","https://openalex.org/W2140870634","https://openalex.org/W2146002559","https://openalex.org/W2146048275","https://openalex.org/W2148440494","https://openalex.org/W2151910032","https://openalex.org/W2161118814","https://openalex.org/W2161690468","https://openalex.org/W2161832815","https://openalex.org/W2164148699","https://openalex.org/W2167844025","https://openalex.org/W2168306830","https://openalex.org/W2171982351","https://openalex.org/W2349776506","https://openalex.org/W2376671269","https://openalex.org/W2798613942","https://openalex.org/W6678481990"],"related_works":["https://openalex.org/W1935823119","https://openalex.org/W2461685797","https://openalex.org/W2997698370","https://openalex.org/W2113820406","https://openalex.org/W2532403069","https://openalex.org/W4294643717","https://openalex.org/W2945660982","https://openalex.org/W2357151375","https://openalex.org/W2366758958","https://openalex.org/W2792215321"],"abstract_inverted_index":{"For":[0],"doubly":[1],"fed":[2],"induction":[3],"generator":[4],"(DFIG)-based":[5],"wind":[6],"energy":[7],"conversion":[8],"systems":[9],"(WECSs),":[10],"large":[11],"electromotive":[12],"force":[13],"will":[14,33],"be":[15],"induced":[16],"in":[17,121],"the":[18,28,41,61,66,70,82,89,99,118,124,141,144,148,155,158],"rotor":[19,29,63,71],"circuit":[20],"during":[21,94],"grid":[22,95],"faults.":[23,96],"Without":[24],"proper":[25],"protection":[26],"scheme,":[27],"side":[30],"of":[31,81,92,106,143,157,166],"DFIG":[32,172],"suffer":[34],"from":[35],"overcurrents,":[36],"which":[37],"may":[38],"even":[39],"destroy":[40],"rotor-side":[42],"converter":[43],"(RSC).":[44],"To":[45,97],"mitigate":[46],"this":[47],"problem,":[48],"a":[49,78,103,107,127,130,170],"new":[50],"flux-linkage-tracking-based":[51],"low-voltage":[52],"ride-through":[53],"(LVRT)":[54],"control":[55,68,90,101,137,145,149],"strategy":[56],"is":[57,74,112,138,151,161],"proposed":[58,67,100,159],"to":[59,76],"suppress":[60],"short-circuit":[62],"current.":[64],"Under":[65],"strategy,":[69,102],"flux":[72,85],"linkage":[73,86],"controlled":[75],"track":[77],"reduced":[79],"fraction":[80],"changing":[83],"stator":[84],"by":[87,115,164],"switching":[88],"algorithm":[91],"RSC":[93,136],"validate":[98],"case":[104,125],"study":[105],"typical":[108,131],"1.5-MW":[109],"DFIG-based":[110],"WECS":[111],"carried":[113],"out":[114],"simulation":[116],"using":[117],"full-order":[119],"model":[120],"SIMULINK/SimPowerSystems.":[122],"In":[123],"study,":[126],"comparison":[128],"with":[129,169],"LVRT":[132],"method":[133,160],"based":[134],"on":[135,147],"given,":[139],"and":[140],"effect":[142],"parameter":[146],"performance":[150],"also":[152],"investigated.":[153],"Finally,":[154],"validity":[156],"further":[162],"verified":[163],"means":[165],"laboratory":[167],"experiments":[168],"scaled-size":[171],"system.":[173]},"counts_by_year":[{"year":2025,"cited_by_count":9},{"year":2024,"cited_by_count":14},{"year":2023,"cited_by_count":17},{"year":2022,"cited_by_count":12},{"year":2021,"cited_by_count":20},{"year":2020,"cited_by_count":21},{"year":2019,"cited_by_count":23},{"year":2018,"cited_by_count":24},{"year":2017,"cited_by_count":17},{"year":2016,"cited_by_count":27},{"year":2015,"cited_by_count":31},{"year":2014,"cited_by_count":23},{"year":2013,"cited_by_count":10},{"year":2012,"cited_by_count":1}],"updated_date":"2026-03-01T08:55:55.761014","created_date":"2025-10-10T00:00:00"}
