{"id":"https://openalex.org/W2126825391","doi":"https://doi.org/10.1109/tie.2011.2157295","title":"Analysis and Test of Diode Rectifier Solutions in Grid-Connected Wind Energy Conversion Systems Employing Modular Permanent-Magnet Synchronous Generators","display_name":"Analysis and Test of Diode Rectifier Solutions in Grid-Connected Wind Energy Conversion Systems Employing Modular Permanent-Magnet Synchronous Generators","publication_year":2011,"publication_date":"2011-05-25","ids":{"openalex":"https://openalex.org/W2126825391","doi":"https://doi.org/10.1109/tie.2011.2157295","mag":"2126825391"},"language":"en","primary_location":{"id":"doi:10.1109/tie.2011.2157295","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2011.2157295","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5043146019","display_name":"A. Di Gerlando","orcid":"https://orcid.org/0000-0002-0650-7086"},"institutions":[{"id":"https://openalex.org/I93860229","display_name":"Politecnico di Milano","ror":"https://ror.org/01nffqt88","country_code":"IT","type":"education","lineage":["https://openalex.org/I93860229"]}],"countries":["IT"],"is_corresponding":true,"raw_author_name":"Antonino Di Gerlando","raw_affiliation_strings":["Department of Electrical Engineering, Politecnico di Milano, Milano, Italy","Dept. of Electr. Eng., Politec. di Milano, Milan, Italy"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Politecnico di Milano, Milano, Italy","institution_ids":["https://openalex.org/I93860229"]},{"raw_affiliation_string":"Dept. of Electr. Eng., Politec. di Milano, Milan, Italy","institution_ids":["https://openalex.org/I93860229"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Gianmaria Foglia","orcid":null},"institutions":[{"id":"https://openalex.org/I93860229","display_name":"Politecnico di Milano","ror":"https://ror.org/01nffqt88","country_code":"IT","type":"education","lineage":["https://openalex.org/I93860229"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Gianmaria Foglia","raw_affiliation_strings":["Department of Electrical Engineering, Politecnico di Milano, Milano, Italy","Dept. of Electr. Eng., Politec. di Milano, Milan, Italy"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Politecnico di Milano, Milano, Italy","institution_ids":["https://openalex.org/I93860229"]},{"raw_affiliation_string":"Dept. of Electr. Eng., Politec. di Milano, Milan, Italy","institution_ids":["https://openalex.org/I93860229"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5060994217","display_name":"Matteo F. Iacchetti","orcid":"https://orcid.org/0000-0001-6961-4789"},"institutions":[{"id":"https://openalex.org/I93860229","display_name":"Politecnico di Milano","ror":"https://ror.org/01nffqt88","country_code":"IT","type":"education","lineage":["https://openalex.org/I93860229"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Matteo Felice Iacchetti","raw_affiliation_strings":["Department of Electrical Engineering, Politecnico di Milano, Milano, Italy","Dept. of Electr. Eng., Politec. di Milano, Milan, Italy"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Politecnico di Milano, Milano, Italy","institution_ids":["https://openalex.org/I93860229"]},{"raw_affiliation_string":"Dept. of Electr. Eng., Politec. di Milano, Milan, Italy","institution_ids":["https://openalex.org/I93860229"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5082324261","display_name":"R. Perini","orcid":"https://orcid.org/0000-0002-5721-7521"},"institutions":[{"id":"https://openalex.org/I93860229","display_name":"Politecnico di Milano","ror":"https://ror.org/01nffqt88","country_code":"IT","type":"education","lineage":["https://openalex.org/I93860229"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Roberto Perini","raw_affiliation_strings":["Department of Electrical Engineering, Politecnico di Milano, Milano, Italy","Dept. of Electr. Eng., Politec. di Milano, Milan, Italy"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Politecnico di Milano, Milano, Italy","institution_ids":["https://openalex.org/I93860229"]},{"raw_affiliation_string":"Dept. of Electr. Eng., Politec. di Milano, Milan, Italy","institution_ids":["https://openalex.org/I93860229"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5043146019"],"corresponding_institution_ids":["https://openalex.org/I93860229"],"apc_list":null,"apc_paid":null,"fwci":7.2941,"has_fulltext":false,"cited_by_count":70,"citation_normalized_percentile":{"value":0.9741941,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":90,"max":99},"biblio":{"volume":"59","issue":"5","first_page":"2135","last_page":"2146"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9980000257492065,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9977999925613403,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/modular-design","display_name":"Modular design","score":0.6232126951217651},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.5503770112991333},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.5388630628585815},{"id":"https://openalex.org/keywords/magnet","display_name":"Magnet","score":0.5114354491233826},{"id":"https://openalex.org/keywords/permanent-magnet-synchronous-generator","display_name":"Permanent magnet synchronous generator","score":0.5055537223815918},{"id":"https://openalex.org/keywords/rectifier","display_name":"Rectifier (neural networks)","score":0.4464777410030365},{"id":"https://openalex.org/keywords/wind-power","display_name":"Wind power","score":0.44015246629714966},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.4344748854637146},{"id":"https://openalex.org/keywords/diode","display_name":"Diode","score":0.41561925411224365},{"id":"https://openalex.org/keywords/ripple","display_name":"Ripple","score":0.41446414589881897},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.39970502257347107},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.3784882724285126},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.21794208884239197}],"concepts":[{"id":"https://openalex.org/C101468663","wikidata":"https://www.wikidata.org/wiki/Q1620158","display_name":"Modular design","level":2,"score":0.6232126951217651},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5503770112991333},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.5388630628585815},{"id":"https://openalex.org/C16389437","wikidata":"https://www.wikidata.org/wiki/Q11421","display_name":"Magnet","level":2,"score":0.5114354491233826},{"id":"https://openalex.org/C201320609","wikidata":"https://www.wikidata.org/wiki/Q3274420","display_name":"Permanent magnet synchronous generator","level":3,"score":0.5055537223815918},{"id":"https://openalex.org/C50100734","wikidata":"https://www.wikidata.org/wiki/Q7303176","display_name":"Rectifier (neural networks)","level":5,"score":0.4464777410030365},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.44015246629714966},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4344748854637146},{"id":"https://openalex.org/C78434282","wikidata":"https://www.wikidata.org/wiki/Q11656","display_name":"Diode","level":2,"score":0.41561925411224365},{"id":"https://openalex.org/C2779599953","wikidata":"https://www.wikidata.org/wiki/Q1776117","display_name":"Ripple","level":3,"score":0.41446414589881897},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.39970502257347107},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3784882724285126},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.21794208884239197},{"id":"https://openalex.org/C147168706","wikidata":"https://www.wikidata.org/wiki/Q1457734","display_name":"Recurrent neural network","level":3,"score":0.0},{"id":"https://openalex.org/C119857082","wikidata":"https://www.wikidata.org/wiki/Q2539","display_name":"Machine learning","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C86582703","wikidata":"https://www.wikidata.org/wiki/Q7617824","display_name":"Stochastic neural network","level":4,"score":0.0},{"id":"https://openalex.org/C50644808","wikidata":"https://www.wikidata.org/wiki/Q192776","display_name":"Artificial neural network","level":2,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/tie.2011.2157295","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tie.2011.2157295","pdf_url":null,"source":{"id":"https://openalex.org/S58031724","display_name":"IEEE Transactions on Industrial Electronics","issn_l":"0278-0046","issn":["0278-0046","1557-9948"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industrial Electronics","raw_type":"journal-article"},{"id":"pmh:oai:pure.atira.dk:openaire_cris_publications/1dca3845-df0a-43e5-aade-73caeeeb2458","is_oa":false,"landing_page_url":"https://research.manchester.ac.uk/en/publications/1dca3845-df0a-43e5-aade-73caeeeb2458","pdf_url":null,"source":{"id":"https://openalex.org/S4306400662","display_name":"Research Explorer (The University of Manchester)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I28407311","host_organization_name":"University of Manchester","host_organization_lineage":["https://openalex.org/I28407311"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Di, G A, Foglia, G M, Iacchetti, M F & Perini, R 2012, 'Analysis and Test of Diode Rectifiers Solutions in Grid Connected Wind Energy Conversion Systems Employing Modular Permanent Magnet Synchronous Generators', I E E E Transactions on Industrial Electronics, vol. 59, no. 5, pp. 2135-2146. https://doi.org/10.1109/TIE.2011.2157295","raw_type":"info:eu-repo/semantics/publishedVersion"},{"id":"pmh:oai:re.public.polimi.it:11311/607955","is_oa":false,"landing_page_url":"http://hdl.handle.net/11311/607955","pdf_url":null,"source":{"id":"https://openalex.org/S4306400312","display_name":"Virtual Community of Pathological Anatomy (University of Castilla La Mancha)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I79189158","host_organization_name":"University of Castilla-La Mancha","host_organization_lineage":["https://openalex.org/I79189158"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8999999761581421,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":29,"referenced_works":["https://openalex.org/W1991192350","https://openalex.org/W1996173888","https://openalex.org/W2009828935","https://openalex.org/W2013002519","https://openalex.org/W2026444604","https://openalex.org/W2028570655","https://openalex.org/W2034784405","https://openalex.org/W2062587322","https://openalex.org/W2087180910","https://openalex.org/W2099958911","https://openalex.org/W2108657028","https://openalex.org/W2113251120","https://openalex.org/W2118450933","https://openalex.org/W2118905643","https://openalex.org/W2120444323","https://openalex.org/W2145789942","https://openalex.org/W2146682809","https://openalex.org/W2157413672","https://openalex.org/W2159609577","https://openalex.org/W2162030535","https://openalex.org/W2162448500","https://openalex.org/W2163344008","https://openalex.org/W2168643979","https://openalex.org/W2169799000","https://openalex.org/W2170392676","https://openalex.org/W2170416399","https://openalex.org/W2172211216","https://openalex.org/W6677658821","https://openalex.org/W6684873843"],"related_works":["https://openalex.org/W4229441739","https://openalex.org/W4303411445","https://openalex.org/W4207040089","https://openalex.org/W2384455639","https://openalex.org/W1519622926","https://openalex.org/W3109306766","https://openalex.org/W2944076747","https://openalex.org/W4286587111","https://openalex.org/W2999364115","https://openalex.org/W2358703277"],"abstract_inverted_index":{"This":[0],"paper":[1],"deals":[2],"with":[3,58],"the":[4,33,35,38,49,53],"ac-dc":[5],"interface":[6],"conversion":[7,12],"in":[8],"grid-connected":[9],"wind":[10],"energy":[11],"systems":[13],"based":[14,24],"on":[15,25],"modular":[16],"permanent-magnet":[17],"synchronous":[18],"generators.":[19,55],"In":[20],"particular,":[21],"some":[22],"solutions":[23,76],"diode":[26],"rectifiers":[27],"are":[28,46],"extensively":[29],"analyzed":[30],"as":[31],"for":[32,80],"waveforms,":[34],"efficiency,":[36],"and":[37,82],"torque":[39],"ripple,":[40],"by":[41,48],"considering":[42],"several":[43],"connections,":[44],"which":[45],"allowed":[47],"inherent":[50],"modularity":[51],"of":[52,62],"considered":[54],"Rectifier":[56],"schemes":[57],"a":[59],"high":[60],"number":[61],"pulses":[63],"can":[64,77],"be":[65,78],"easily":[66],"realized":[67],"without":[68],"using":[69],"special":[70],"shifter":[71],"transformers":[72],"so":[73],"that":[74],"these":[75],"attractive":[79],"low-":[81],"medium-power":[83],"applications.":[84]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":3},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":9},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":2},{"year":2018,"cited_by_count":5},{"year":2017,"cited_by_count":4},{"year":2016,"cited_by_count":9},{"year":2015,"cited_by_count":5},{"year":2014,"cited_by_count":12},{"year":2013,"cited_by_count":12},{"year":2012,"cited_by_count":3}],"updated_date":"2026-04-21T08:09:41.155169","created_date":"2025-10-10T00:00:00"}