{"id":"https://openalex.org/W7130309114","doi":"https://doi.org/10.1109/tencon66050.2025.11375099","title":"Modified INN Control Law for Efficient Flow Regulation with Pneumatic Control Valve","display_name":"Modified INN Control Law for Efficient Flow Regulation with Pneumatic Control Valve","publication_year":2025,"publication_date":"2025-10-27","ids":{"openalex":"https://openalex.org/W7130309114","doi":"https://doi.org/10.1109/tencon66050.2025.11375099"},"language":null,"primary_location":{"id":"doi:10.1109/tencon66050.2025.11375099","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tencon66050.2025.11375099","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"TENCON 2025 - 2025 IEEE Region 10 Conference (TENCON)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5115894771","display_name":"ManMahendra Singh Daksh","orcid":null},"institutions":[{"id":"https://openalex.org/I74796645","display_name":"Birla Institute of Technology and Science, Pilani","ror":"https://ror.org/001p3jz28","country_code":"IN","type":"education","lineage":["https://openalex.org/I74796645"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Manmahendra Singh Daksh","raw_affiliation_strings":["Birla Institute of Technology and Science, Pilani, Pilani campus,Department of Electrical and Electronics Engineering,Rajasthan,India,333031"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Birla Institute of Technology and Science, Pilani, Pilani campus,Department of Electrical and Electronics Engineering,Rajasthan,India,333031","institution_ids":["https://openalex.org/I74796645"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5112956107","display_name":"Puneet Mishra","orcid":null},"institutions":[{"id":"https://openalex.org/I74796645","display_name":"Birla Institute of Technology and Science, Pilani","ror":"https://ror.org/001p3jz28","country_code":"IN","type":"education","lineage":["https://openalex.org/I74796645"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Puneet Mishra","raw_affiliation_strings":["Birla Institute of Technology and Science, Pilani, Pilani campus,Department of Electrical and Electronics Engineering,Rajasthan,India,333031"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Birla Institute of Technology and Science, Pilani, Pilani campus,Department of Electrical and Electronics Engineering,Rajasthan,India,333031","institution_ids":["https://openalex.org/I74796645"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I74796645"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.77063938,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"36","last_page":"40"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11372","display_name":"Hydraulic and Pneumatic Systems","score":0.4178999960422516,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11372","display_name":"Hydraulic and Pneumatic Systems","score":0.4178999960422516,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.09070000052452087,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10791","display_name":"Advanced Control Systems Optimization","score":0.06019999831914902,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/setpoint","display_name":"Setpoint","score":0.8414999842643738},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.7357000112533569},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.5809000134468079},{"id":"https://openalex.org/keywords/process","display_name":"Process (computing)","score":0.5393000245094299},{"id":"https://openalex.org/keywords/process-control","display_name":"Process control","score":0.4887999892234802},{"id":"https://openalex.org/keywords/flow-control","display_name":"Flow control (data)","score":0.44760000705718994},{"id":"https://openalex.org/keywords/control-valves","display_name":"Control valves","score":0.42289999127388},{"id":"https://openalex.org/keywords/pid-controller","display_name":"PID controller","score":0.398499995470047},{"id":"https://openalex.org/keywords/pneumatic-flow-control","display_name":"Pneumatic flow control","score":0.39809998869895935}],"concepts":[{"id":"https://openalex.org/C12302492","wikidata":"https://www.wikidata.org/wiki/Q1752097","display_name":"Setpoint","level":2,"score":0.8414999842643738},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.7357000112533569},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.5809000134468079},{"id":"https://openalex.org/C98045186","wikidata":"https://www.wikidata.org/wiki/Q205663","display_name":"Process (computing)","level":2,"score":0.5393000245094299},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.5128999948501587},{"id":"https://openalex.org/C155386361","wikidata":"https://www.wikidata.org/wiki/Q1649571","display_name":"Process control","level":3,"score":0.4887999892234802},{"id":"https://openalex.org/C186766456","wikidata":"https://www.wikidata.org/wiki/Q612457","display_name":"Flow control (data)","level":2,"score":0.44760000705718994},{"id":"https://openalex.org/C182043768","wikidata":"https://www.wikidata.org/wiki/Q1816388","display_name":"Control valves","level":2,"score":0.42289999127388},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.41510000824928284},{"id":"https://openalex.org/C47116090","wikidata":"https://www.wikidata.org/wiki/Q716829","display_name":"PID controller","level":3,"score":0.398499995470047},{"id":"https://openalex.org/C103578843","wikidata":"https://www.wikidata.org/wiki/Q1816388","display_name":"Pneumatic flow control","level":2,"score":0.39809998869895935},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3935999870300293},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.3871999979019165},{"id":"https://openalex.org/C38349280","wikidata":"https://www.wikidata.org/wiki/Q1434290","display_name":"Flow (mathematics)","level":2,"score":0.3869999945163727},{"id":"https://openalex.org/C176180004","wikidata":"https://www.wikidata.org/wiki/Q356235","display_name":"Flow control valve","level":2,"score":0.35420000553131104},{"id":"https://openalex.org/C38858127","wikidata":"https://www.wikidata.org/wiki/Q5441228","display_name":"Feed forward","level":2,"score":0.32179999351501465},{"id":"https://openalex.org/C107354338","wikidata":"https://www.wikidata.org/wiki/Q1937153","display_name":"Servo","level":2,"score":0.3190999925136566},{"id":"https://openalex.org/C170401851","wikidata":"https://www.wikidata.org/wiki/Q1965061","display_name":"Pneumatic actuator","level":3,"score":0.2996000051498413},{"id":"https://openalex.org/C109217959","wikidata":"https://www.wikidata.org/wiki/Q4567087","display_name":"Pneumatic cylinder","level":3,"score":0.29760000109672546},{"id":"https://openalex.org/C173909513","wikidata":"https://www.wikidata.org/wiki/Q645549","display_name":"Valve actuator","level":3,"score":0.2946000099182129},{"id":"https://openalex.org/C2778755073","wikidata":"https://www.wikidata.org/wiki/Q10858537","display_name":"Scale (ratio)","level":2,"score":0.289000004529953},{"id":"https://openalex.org/C177264268","wikidata":"https://www.wikidata.org/wiki/Q1514741","display_name":"Set (abstract data type)","level":2,"score":0.2858999967575073},{"id":"https://openalex.org/C168167062","wikidata":"https://www.wikidata.org/wiki/Q1117970","display_name":"Component (thermodynamics)","level":2,"score":0.28360000252723694},{"id":"https://openalex.org/C159484563","wikidata":"https://www.wikidata.org/wiki/Q628723","display_name":"Dead time","level":2,"score":0.2809999883174896},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.2721000015735626},{"id":"https://openalex.org/C167123822","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automatic control","level":2,"score":0.2705000042915344},{"id":"https://openalex.org/C22762622","wikidata":"https://www.wikidata.org/wiki/Q628904","display_name":"Operating point","level":2,"score":0.2621999979019165},{"id":"https://openalex.org/C31531917","wikidata":"https://www.wikidata.org/wiki/Q915157","display_name":"Robust control","level":3,"score":0.2621000111103058},{"id":"https://openalex.org/C85617194","wikidata":"https://www.wikidata.org/wiki/Q2072794","display_name":"Particle swarm optimization","level":2,"score":0.25189998745918274}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tencon66050.2025.11375099","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tencon66050.2025.11375099","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"TENCON 2025 - 2025 IEEE Region 10 Conference (TENCON)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/16","score":0.5932328701019287,"display_name":"Peace, Justice and strong institutions"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W588399736","https://openalex.org/W1968093301","https://openalex.org/W2064815992","https://openalex.org/W2122250135","https://openalex.org/W2161256670","https://openalex.org/W2785609098","https://openalex.org/W2797423495","https://openalex.org/W2805977520","https://openalex.org/W2919003925","https://openalex.org/W2967448992","https://openalex.org/W3194869541","https://openalex.org/W3209340886","https://openalex.org/W4205129187","https://openalex.org/W4403874593","https://openalex.org/W4408861737","https://openalex.org/W4409185213"],"related_works":[],"abstract_inverted_index":{"In":[0,81,144,179],"the":[1,5,9,14,22,25,31,58,77,85,101,109,112,127,136,150,152,160,170,173,180,183,189,194,214,224,231,247],"industrial":[2],"process":[3,71,88,146,156],"plant,":[4],"control":[6,45,61,79,130,134,142,208,215],"valve":[7,174,216],"is":[8,19,27,106,157],"key":[10],"component":[11],"in":[12,29,149,177,223,230,234],"regulating":[13],"flow":[15,70,75,155,171,212],"of":[16,103,111,147,162,182,226,236,258],"fluid":[17,74,211],"that":[18,47],"done":[20,107],"by":[21,244],"controller.":[23],"Hence,":[24],"controller":[26,91,187,250],"crucial":[28],"improving":[30],"plant's":[32,190],"overall":[33],"efficiency.":[34],"This":[35],"paper":[36],"proposes":[37],"a":[38,67,163,238,255,261],"new":[39],"modified":[40,185],"Inverse":[41],"Neural":[42],"Network":[43],"(INN)":[44],"law":[46,62],"provides":[48],"better":[49],"setpoint":[50],"tracking":[51],"and":[52,90,99,131,169],"disturbance":[53,229],"rejection":[54],"performance":[55,253],"compared":[56,204],"to":[57,72,205,209],"existing":[59,132,206,248],"INN":[60,129,133,186,207,249],"while":[63,126,260],"being":[64],"tested":[65,139],"on":[66],"laboratory":[68,153],"scale":[69,154],"regulate":[73,210],"across":[76,172,213],"pneumatic":[78],"valve.":[80],"this":[82,145],"proposed":[83,184],"work,":[84],"data":[86],"for":[87,95,135,140,217,254],"variables":[89],"outputs":[92],"are":[93,121,138],"taken":[94],"different":[96,218],"set":[97,195],"points,":[98],"then":[100],"identification":[102],"system":[104],"parameters":[105,120],"with":[108,159,198],"help":[110,161],"Particle":[113],"Swarm":[114],"Optimization":[115],"(PSO)":[116],"technique.":[117],"The":[118],"identified":[119],"used":[122],"as":[123,220,222],"initial":[124],"parameters,":[125],"updated":[128],"plant":[137],"optimized":[141],"performance.":[143,269],"hardware":[148],"loop,":[151],"interfaced":[158],"DAQ":[164],"USB":[165],"device,":[166],"NI":[167],"USB-6001,":[168],"gets":[175],"controlled":[176],"real-time.":[178],"case":[181,225],"(MOD-INN),":[188],"actual":[191],"output":[192],"tracks":[193],"point":[196],"precisely":[197],"lower":[199],"Integral":[200],"Absolute":[201],"Error":[202],"(IAE)":[203],"setpoints,":[219],"well":[221],"an":[227],"introduced":[228],"setpoint.":[232],"Quantitatively,":[233],"terms":[235],"IAE,":[237],"13.44":[239],"times":[240,263],"improvement":[241,264],"was":[242,265],"achieved":[243],"MOD-INN":[245],"over":[246],"under":[251,267],"servo":[252],"1.2V":[256],"value":[257],"setpoint,":[259],"10.94":[262],"observed":[266],"regulatory":[268]},"counts_by_year":[],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2026-02-19T00:00:00"}
