{"id":"https://openalex.org/W7130430018","doi":"https://doi.org/10.1109/tencon66050.2025.11374924","title":"Smart Temperature Tracker for Thermoregulatory Disorders","display_name":"Smart Temperature Tracker for Thermoregulatory Disorders","publication_year":2025,"publication_date":"2025-10-27","ids":{"openalex":"https://openalex.org/W7130430018","doi":"https://doi.org/10.1109/tencon66050.2025.11374924"},"language":null,"primary_location":{"id":"doi:10.1109/tencon66050.2025.11374924","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tencon66050.2025.11374924","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"TENCON 2025 - 2025 IEEE Region 10 Conference (TENCON)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5116806275","display_name":"Olanrewaju Bola Wojula","orcid":null},"institutions":[{"id":"https://openalex.org/I27765905","display_name":"North-West University","ror":"https://ror.org/010f1sq29","country_code":"ZA","type":"education","lineage":["https://openalex.org/I27765905"]}],"countries":["ZA"],"is_corresponding":false,"raw_author_name":"Olanrewaju Bola Wojula","raw_affiliation_strings":["North-West University,Department of Physics,South Africa"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"North-West University,Department of Physics,South Africa","institution_ids":["https://openalex.org/I27765905"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5120670659","display_name":"Kutlwano Benedict Tigele","orcid":null},"institutions":[{"id":"https://openalex.org/I27765905","display_name":"North-West University","ror":"https://ror.org/010f1sq29","country_code":"ZA","type":"education","lineage":["https://openalex.org/I27765905"]}],"countries":["ZA"],"is_corresponding":false,"raw_author_name":"Kutlwano Benedict Tigele","raw_affiliation_strings":["North-West University,Department of Physics,South Africa"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"North-West University,Department of Physics,South Africa","institution_ids":["https://openalex.org/I27765905"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I27765905"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.81052632,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"903","last_page":"906"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11861","display_name":"Thermal Regulation in Medicine","score":0.5097000002861023,"subfield":{"id":"https://openalex.org/subfields/2706","display_name":"Critical Care and Intensive Care Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T11861","display_name":"Thermal Regulation in Medicine","score":0.5097000002861023,"subfield":{"id":"https://openalex.org/subfields/2706","display_name":"Critical Care and Intensive Care Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T12994","display_name":"Infrared Thermography in Medicine","score":0.18889999389648438,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.03280000016093254,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/human-body-temperature","display_name":"Human body temperature","score":0.5781000256538391},{"id":"https://openalex.org/keywords/power-consumption","display_name":"Power consumption","score":0.552299976348877},{"id":"https://openalex.org/keywords/temperature-measurement","display_name":"Temperature measurement","score":0.5475000143051147},{"id":"https://openalex.org/keywords/skin-temperature","display_name":"Skin temperature","score":0.5397999882698059},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.4973999857902527},{"id":"https://openalex.org/keywords/thermocouple","display_name":"Thermocouple","score":0.4941999912261963},{"id":"https://openalex.org/keywords/hyperthermia","display_name":"Hyperthermia","score":0.4165000021457672},{"id":"https://openalex.org/keywords/thermometer","display_name":"Thermometer","score":0.36899998784065247},{"id":"https://openalex.org/keywords/remote-patient-monitoring","display_name":"Remote patient monitoring","score":0.34549999237060547}],"concepts":[{"id":"https://openalex.org/C20390774","wikidata":"https://www.wikidata.org/wiki/Q16679262","display_name":"Human body temperature","level":2,"score":0.5781000256538391},{"id":"https://openalex.org/C2984118289","wikidata":"https://www.wikidata.org/wiki/Q29954","display_name":"Power consumption","level":3,"score":0.552299976348877},{"id":"https://openalex.org/C72293138","wikidata":"https://www.wikidata.org/wiki/Q909741","display_name":"Temperature measurement","level":2,"score":0.5475000143051147},{"id":"https://openalex.org/C3019079563","wikidata":"https://www.wikidata.org/wiki/Q67173088","display_name":"Skin temperature","level":2,"score":0.5397999882698059},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.4973999857902527},{"id":"https://openalex.org/C168068576","wikidata":"https://www.wikidata.org/wiki/Q190241","display_name":"Thermocouple","level":2,"score":0.4941999912261963},{"id":"https://openalex.org/C2779949491","wikidata":"https://www.wikidata.org/wiki/Q242165","display_name":"Hyperthermia","level":2,"score":0.4165000021457672},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4041999876499176},{"id":"https://openalex.org/C2777155165","wikidata":"https://www.wikidata.org/wiki/Q646","display_name":"Thermometer","level":2,"score":0.36899998784065247},{"id":"https://openalex.org/C175079658","wikidata":"https://www.wikidata.org/wiki/Q7312165","display_name":"Remote patient monitoring","level":2,"score":0.34549999237060547},{"id":"https://openalex.org/C2983363897","wikidata":"https://www.wikidata.org/wiki/Q845339","display_name":"Air temperature","level":2,"score":0.3424000144004822},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3370000123977661},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.33379998803138733},{"id":"https://openalex.org/C167781694","wikidata":"https://www.wikidata.org/wiki/Q6311800","display_name":"Junction temperature","level":3,"score":0.3278999924659729},{"id":"https://openalex.org/C2779222261","wikidata":"https://www.wikidata.org/wiki/Q624587","display_name":"Thermography","level":3,"score":0.326200008392334},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.30970001220703125},{"id":"https://openalex.org/C2778823008","wikidata":"https://www.wikidata.org/wiki/Q3523897","display_name":"Infrared thermometer","level":3,"score":0.30869999527931213},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.3077999949455261},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2930000126361847},{"id":"https://openalex.org/C2776902269","wikidata":"https://www.wikidata.org/wiki/Q5165493","display_name":"Continuous monitoring","level":2,"score":0.29089999198913574},{"id":"https://openalex.org/C536315585","wikidata":"https://www.wikidata.org/wiki/Q7698332","display_name":"Temperature control","level":2,"score":0.2806999981403351},{"id":"https://openalex.org/C2776433176","wikidata":"https://www.wikidata.org/wiki/Q1191065","display_name":"Heat illness","level":2,"score":0.27230000495910645},{"id":"https://openalex.org/C2776890885","wikidata":"https://www.wikidata.org/wiki/Q1067560","display_name":"Vital signs","level":2,"score":0.27059999108314514},{"id":"https://openalex.org/C131321042","wikidata":"https://www.wikidata.org/wiki/Q656685","display_name":"Operating temperature","level":2,"score":0.26489999890327454},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.2612000107765198},{"id":"https://openalex.org/C173018170","wikidata":"https://www.wikidata.org/wiki/Q165678","display_name":"Microcontroller","level":2,"score":0.26010000705718994}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tencon66050.2025.11374924","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tencon66050.2025.11374924","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"TENCON 2025 - 2025 IEEE Region 10 Conference (TENCON)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.4571343958377838,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W2002937150","https://openalex.org/W2543488553","https://openalex.org/W2586366032","https://openalex.org/W2784771454","https://openalex.org/W2947888826","https://openalex.org/W2963218670","https://openalex.org/W3084707924","https://openalex.org/W4236468523","https://openalex.org/W4392134730","https://openalex.org/W4392916627"],"related_works":[],"abstract_inverted_index":{"Monitoring":[0],"body":[1,149],"temperature":[2,15,28,45,73,78,97,115,122,150],"is":[3,30,100],"crucial":[4,31],"for":[5,21,32,37,52,64,113],"detecting":[6],"illness":[7],"and":[8,36,83,88,124,134,145,158],"evaluating":[9],"the":[10,128],"effectiveness":[11],"of":[12],"treatment.":[13],"Particularly,":[14],"monitoring":[16,29,46,98],"plays":[17],"an":[18,118,125],"important":[19],"role":[20],"those":[22],"with":[23,105],"thermoregulatory":[24],"disorders,":[25],"as":[26],"accurate":[27],"managing":[33],"their":[34],"conditions":[35],"preventing":[38],"serious":[39],"complications.":[40],"This":[41],"paper":[42],"proposes":[43],"a":[44,57,65,121],"system":[47,99,129],"that":[48,67],"can":[49],"be":[50],"used":[51],"assisting":[53],"individuals":[54],"experiencing":[55],"such":[56],"disorder.":[58],"We":[59],"also":[60],"present":[61],"test":[62],"results":[63],"prototype":[66,71,140],"we":[68],"developed.":[69],"The":[70,96,138],"monitors":[72],"in":[74,147],"real":[75],"time,":[76],"records":[77],"data":[79],"every":[80],"five":[81],"minutes":[82],"sends":[84],"alerts":[85,112],"to":[86,102,153],"users":[87],"medical":[89],"services":[90],"during":[91],"severe":[92],"hyperthermia":[93],"or":[94],"hypothermia.":[95],"designed":[101,139],"operate":[103],"efficiently":[104],"low":[106],"power":[107],"consumption":[108],"while":[109],"providing":[110],"real-time":[111],"abnormal":[114],"conditions.":[116],"Utilizing":[117],"Arduino":[119],"board,":[120],"sensor,":[123],"OLED":[126],"display,":[127],"integrates":[130],"advanced":[131],"sleep":[132],"modes":[133],"user":[135],"interaction":[136],"features.":[137],"has":[141],"demonstrated":[142],"good":[143],"accuracy":[144],"reliability":[146],"measuring":[148],"when":[151],"compared":[152],"both":[154],"clinical":[155],"digital":[156],"thermometers":[157],"infrared":[159],"gun":[160],"thermometers.":[161]},"counts_by_year":[],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2026-02-19T00:00:00"}
