{"id":"https://openalex.org/W2995402913","doi":"https://doi.org/10.1109/tencon.2019.8929246","title":"Fork and D/y/d Connected Transformer Supplied 12-Pulse Uncontrolled Converter fed Retrofit Vector Controlled Induction Motor Drive: A Comparative Study","display_name":"Fork and D/y/d Connected Transformer Supplied 12-Pulse Uncontrolled Converter fed Retrofit Vector Controlled Induction Motor Drive: A Comparative Study","publication_year":2019,"publication_date":"2019-10-01","ids":{"openalex":"https://openalex.org/W2995402913","doi":"https://doi.org/10.1109/tencon.2019.8929246","mag":"2995402913"},"language":"en","primary_location":{"id":"doi:10.1109/tencon.2019.8929246","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tencon.2019.8929246","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"TENCON 2019 - 2019 IEEE Region 10 Conference (TENCON)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5012228647","display_name":"Aekamdeep Kaur","orcid":null},"institutions":[{"id":"https://openalex.org/I4210136518","display_name":"Maharaja Ranjit Singh Punjab Technical University","ror":"https://ror.org/03k7qz240","country_code":"IN","type":"education","lineage":["https://openalex.org/I4210136518"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"Aekamdeep Kaur","raw_affiliation_strings":["Department of Electrical Engineering, Giani Zail Singh Campus College of Engineering and Technology, MRSPTU, Bathinda, India"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Giani Zail Singh Campus College of Engineering and Technology, MRSPTU, Bathinda, India","institution_ids":["https://openalex.org/I4210136518"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5103881923","display_name":"Yugal Gupta","orcid":null},"institutions":[{"id":"https://openalex.org/I94234084","display_name":"Indian Institute of Technology Kanpur","ror":"https://ror.org/05pjsgx75","country_code":"IN","type":"education","lineage":["https://openalex.org/I94234084"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Yugal Gupta","raw_affiliation_strings":["Department of Electrical Engineering, Indian Institue of Technology Kanpur, Kanpur, India"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Indian Institue of Technology Kanpur, Kanpur, India","institution_ids":["https://openalex.org/I94234084"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5037249487","display_name":"Sumit Ghatak Choudhuri","orcid":null},"institutions":[{"id":"https://openalex.org/I154851008","display_name":"Indian Institute of Technology Roorkee","ror":"https://ror.org/00582g326","country_code":"IN","type":"education","lineage":["https://openalex.org/I154851008"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Sumit Ghatak Choudhuri","raw_affiliation_strings":["Department of Electrical Engineering, Indian Institue of Technology Roorkee, Roorkee, India"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Indian Institue of Technology Roorkee, Roorkee, India","institution_ids":["https://openalex.org/I154851008"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5012228647"],"corresponding_institution_ids":["https://openalex.org/I4210136518"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.1411265,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"3","issue":null,"first_page":"1643","last_page":"1648"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10504","display_name":"Sensorless Control of Electric Motors","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fork","display_name":"Fork (system call)","score":0.687788724899292},{"id":"https://openalex.org/keywords/induction-motor","display_name":"Induction motor","score":0.6618116497993469},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.6260788440704346},{"id":"https://openalex.org/keywords/matlab","display_name":"MATLAB","score":0.6166308522224426},{"id":"https://openalex.org/keywords/pulse-width-modulation","display_name":"Pulse-width modulation","score":0.49099066853523254},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.43747588992118835},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.4150150716304779},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.31676357984542847},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.17318248748779297},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.08976250886917114}],"concepts":[{"id":"https://openalex.org/C40523978","wikidata":"https://www.wikidata.org/wiki/Q14675","display_name":"Fork (system call)","level":2,"score":0.687788724899292},{"id":"https://openalex.org/C80962145","wikidata":"https://www.wikidata.org/wiki/Q207450","display_name":"Induction motor","level":3,"score":0.6618116497993469},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.6260788440704346},{"id":"https://openalex.org/C2780365114","wikidata":"https://www.wikidata.org/wiki/Q169478","display_name":"MATLAB","level":2,"score":0.6166308522224426},{"id":"https://openalex.org/C92746544","wikidata":"https://www.wikidata.org/wiki/Q585184","display_name":"Pulse-width modulation","level":3,"score":0.49099066853523254},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.43747588992118835},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4150150716304779},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.31676357984542847},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.17318248748779297},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.08976250886917114},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tencon.2019.8929246","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tencon.2019.8929246","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"TENCON 2019 - 2019 IEEE Region 10 Conference (TENCON)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.6100000143051147,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W605508373","https://openalex.org/W1526341143","https://openalex.org/W1573847156","https://openalex.org/W1576410889","https://openalex.org/W1986841761","https://openalex.org/W2070594546","https://openalex.org/W2102944167","https://openalex.org/W2105725374","https://openalex.org/W2152894944","https://openalex.org/W2155893775","https://openalex.org/W2507034709","https://openalex.org/W3147537413","https://openalex.org/W4255104988","https://openalex.org/W4300423922"],"related_works":["https://openalex.org/W2937118960","https://openalex.org/W2808525305","https://openalex.org/W3132572030","https://openalex.org/W3208656504","https://openalex.org/W3127613622","https://openalex.org/W2808177972","https://openalex.org/W3085385306","https://openalex.org/W4379380002","https://openalex.org/W3201151259","https://openalex.org/W2001279702"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"a":[3,7],"comparative":[4],"investigation":[5,79],"when":[6,41],"12-pulse,":[8],"uncontrolled":[9],"converter":[10],"fed":[11],"retrofit":[12],"Vector":[13],"Controlled":[14],"Induction":[15],"Motor":[16],"Drive":[17],"(VCIMD)":[18],"is":[19,65,80],"supplied":[20],"from":[21],"D/y/d":[22,44],"and":[23,58,69,87],"Fork":[24,31],"transformers,":[25],"respectively.":[26,62],"The":[27,78],"study":[28],"proves":[29],"that":[30],"configuration":[32],"results":[33],"into":[34],"reduction":[35],"of":[36],"total":[37],"transformer":[38],"magnetic":[39],"rating":[40],"compared":[42,66],"to":[43],"configuration,":[45],"at":[46],"almost":[47],"same":[48],"power":[49],"quality":[50],"performance":[51,64],"level,":[52],"observed":[53],"on":[54],"Full":[55],"Load":[56,60],"(FL)":[57],"Light":[59],"(LL),":[61],"VCIMD":[63],"under":[67],"starting":[68],"load":[70],"perturbation":[71],"modes":[72],"suitable":[73],"for":[74],"various":[75],"industrial":[76],"applications.":[77],"realised":[81],"in":[82,93],"MATLAB":[83],"environment":[84],"using":[85],"Simulink":[86],"Sim":[88],"Power":[89],"System":[90],"(SPS)":[91],"toolboxes":[92],"Discrete":[94],"Time":[95],"Frame":[96],"(DTF).":[97]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
