{"id":"https://openalex.org/W2920071116","doi":"https://doi.org/10.1109/tencon.2018.8650347","title":"A Microreservior-based Drug Delivery Device Using Ionic Polymer Metal Composite (IPMC) Actuator","display_name":"A Microreservior-based Drug Delivery Device Using Ionic Polymer Metal Composite (IPMC) Actuator","publication_year":2018,"publication_date":"2018-10-01","ids":{"openalex":"https://openalex.org/W2920071116","doi":"https://doi.org/10.1109/tencon.2018.8650347","mag":"2920071116"},"language":"en","primary_location":{"id":"doi:10.1109/tencon.2018.8650347","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tencon.2018.8650347","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"TENCON 2018 - 2018 IEEE Region 10 Conference","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5002003207","display_name":"Xi Liang Chang","orcid":"https://orcid.org/0000-0003-2518-3715"},"institutions":[{"id":"https://openalex.org/I931681460","display_name":"Universiti Tunku Abdul Rahman","ror":"https://ror.org/050pq4m56","country_code":"MY","type":"education","lineage":["https://openalex.org/I931681460"]}],"countries":["MY"],"is_corresponding":false,"raw_author_name":"Xi Liang Chang","raw_affiliation_strings":["Department of Electrical and Electronic Engineering, Universiti Tunku Abdul Rahman, Malaysia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Electronic Engineering, Universiti Tunku Abdul Rahman, Malaysia","institution_ids":["https://openalex.org/I931681460"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5020714367","display_name":"Pei Song Chee","orcid":"https://orcid.org/0000-0001-7165-7788"},"institutions":[{"id":"https://openalex.org/I931681460","display_name":"Universiti Tunku Abdul Rahman","ror":"https://ror.org/050pq4m56","country_code":"MY","type":"education","lineage":["https://openalex.org/I931681460"]}],"countries":["MY"],"is_corresponding":false,"raw_author_name":"Pei Song Chee","raw_affiliation_strings":["Department of Electrical and Electronic Engineering, Universiti Tunku Abdul Rahman, Malaysia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Electronic Engineering, Universiti Tunku Abdul Rahman, Malaysia","institution_ids":["https://openalex.org/I931681460"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5045254671","display_name":"Eng-Hock Lim","orcid":"https://orcid.org/0000-0001-5301-1115"},"institutions":[{"id":"https://openalex.org/I931681460","display_name":"Universiti Tunku Abdul Rahman","ror":"https://ror.org/050pq4m56","country_code":"MY","type":"education","lineage":["https://openalex.org/I931681460"]}],"countries":["MY"],"is_corresponding":false,"raw_author_name":"Eng Hock Lim","raw_affiliation_strings":["Department of Electrical and Electronic Engineering, Universiti Tunku Abdul Rahman, Malaysia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Electronic Engineering, Universiti Tunku Abdul Rahman, Malaysia","institution_ids":["https://openalex.org/I931681460"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.3345,"has_fulltext":false,"cited_by_count":6,"citation_normalized_percentile":{"value":0.59642869,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"0899","last_page":"0902"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11608","display_name":"Dielectric materials and actuators","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11608","display_name":"Dielectric materials and actuators","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10338","display_name":"Advanced Sensor and Energy Harvesting Materials","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10412","display_name":"Microfluidic and Capillary Electrophoresis Applications","score":0.9865000247955322,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/polydimethylsiloxane","display_name":"Polydimethylsiloxane","score":0.8428431749343872},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.8369123339653015},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.8081294894218445},{"id":"https://openalex.org/keywords/drug-delivery","display_name":"Drug delivery","score":0.5622999668121338},{"id":"https://openalex.org/keywords/composite-number","display_name":"Composite number","score":0.5611356496810913},{"id":"https://openalex.org/keywords/deflection","display_name":"Deflection (physics)","score":0.5514631271362305},{"id":"https://openalex.org/keywords/polymer","display_name":"Polymer","score":0.5269801616668701},{"id":"https://openalex.org/keywords/nafion","display_name":"Nafion","score":0.5182697176933289},{"id":"https://openalex.org/keywords/electrode","display_name":"Electrode","score":0.5181471109390259},{"id":"https://openalex.org/keywords/composite-material","display_name":"Composite material","score":0.49226608872413635},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.36485666036605835},{"id":"https://openalex.org/keywords/nanotechnology","display_name":"Nanotechnology","score":0.23952335119247437},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.1014399528503418},{"id":"https://openalex.org/keywords/chemistry","display_name":"Chemistry","score":0.07713830471038818},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.0732337236404419}],"concepts":[{"id":"https://openalex.org/C2779849746","wikidata":"https://www.wikidata.org/wiki/Q411955","display_name":"Polydimethylsiloxane","level":2,"score":0.8428431749343872},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.8369123339653015},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.8081294894218445},{"id":"https://openalex.org/C2779820397","wikidata":"https://www.wikidata.org/wiki/Q1392806","display_name":"Drug delivery","level":2,"score":0.5622999668121338},{"id":"https://openalex.org/C104779481","wikidata":"https://www.wikidata.org/wiki/Q50707","display_name":"Composite number","level":2,"score":0.5611356496810913},{"id":"https://openalex.org/C2781355719","wikidata":"https://www.wikidata.org/wiki/Q2080698","display_name":"Deflection (physics)","level":2,"score":0.5514631271362305},{"id":"https://openalex.org/C521977710","wikidata":"https://www.wikidata.org/wiki/Q81163","display_name":"Polymer","level":2,"score":0.5269801616668701},{"id":"https://openalex.org/C2778665636","wikidata":"https://www.wikidata.org/wiki/Q412967","display_name":"Nafion","level":4,"score":0.5182697176933289},{"id":"https://openalex.org/C17525397","wikidata":"https://www.wikidata.org/wiki/Q176140","display_name":"Electrode","level":2,"score":0.5181471109390259},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.49226608872413635},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.36485666036605835},{"id":"https://openalex.org/C171250308","wikidata":"https://www.wikidata.org/wiki/Q11468","display_name":"Nanotechnology","level":1,"score":0.23952335119247437},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.1014399528503418},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.07713830471038818},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.0732337236404419},{"id":"https://openalex.org/C52859227","wikidata":"https://www.wikidata.org/wiki/Q7877","display_name":"Electrochemistry","level":3,"score":0.0},{"id":"https://openalex.org/C147789679","wikidata":"https://www.wikidata.org/wiki/Q11372","display_name":"Physical chemistry","level":1,"score":0.0},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tencon.2018.8650347","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tencon.2018.8650347","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"TENCON 2018 - 2018 IEEE Region 10 Conference","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.6200000047683716,"id":"https://metadata.un.org/sdg/3","display_name":"Good health and well-being"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":19,"referenced_works":["https://openalex.org/W797910959","https://openalex.org/W1983502894","https://openalex.org/W2003543973","https://openalex.org/W2004405943","https://openalex.org/W2116819863","https://openalex.org/W2119784281","https://openalex.org/W2136718114","https://openalex.org/W2138576321","https://openalex.org/W2146821358","https://openalex.org/W2313119575","https://openalex.org/W2334378405","https://openalex.org/W2334881387","https://openalex.org/W2417078810","https://openalex.org/W2548036195","https://openalex.org/W2585812490","https://openalex.org/W2656250965","https://openalex.org/W2791583440","https://openalex.org/W2891934774","https://openalex.org/W6681469768"],"related_works":["https://openalex.org/W3048672776","https://openalex.org/W2463824739","https://openalex.org/W3043268847","https://openalex.org/W3142048519","https://openalex.org/W2347469006","https://openalex.org/W1982946447","https://openalex.org/W30070463","https://openalex.org/W2892390219","https://openalex.org/W2087999094","https://openalex.org/W2900524175"],"abstract_inverted_index":{"This":[0],"paper":[1],"reports":[2],"a":[3,58],"microreservior-based":[4],"drug":[5,42,78],"delivery":[6],"device":[7,38],"that":[8,108],"is":[9,20],"activated":[10],"by":[11],"ionic":[12],"polymer":[13],"metal":[14],"composite":[15],"(IPMC)":[16],"actuator.":[17],"The":[18],"actuator":[19,56,110],"fabricated":[21,54],"with":[22,28,34],"Nafion":[23],"117":[24],"membrane":[25],"and":[26,91,115],"plated":[27],"silver":[29],"layer":[30],"electrodes.":[31],"To":[32,72],"fit":[33],"biocompatible":[35],"properties,":[36],"the":[37,41,53,74,77,81,89,92,104,113,117],"body,":[39],"including":[40],"reservoir,":[43],"was":[44,86,95],"constructed":[45],"using":[46,97],"polydimethylsiloxane":[47],"(PDMS)":[48],"material.":[49],"Experimental":[50],"measurement":[51],"of":[52,62,76,103],"IPMC":[55,109],"shows":[57,107],"maximum":[59],"deflection":[60],"displacement":[61],"0.076":[63],"~":[64],"0.077":[65],"mm":[66],"at":[67],"two":[68],"consecutive":[69],"actuation":[70],"cycles.":[71],"study":[73],"concentration":[75],"released":[79,93],"from":[80],"developed":[82],"device,":[83],"fluorescent":[84,105],"dye":[85],"loaded":[87],"in":[88],"reservoir":[90],"intensity":[94,106],"measured":[96],"well":[98],"plate":[99],"reader.":[100],"An":[101],"increase":[102],"successfully":[111],"unseals":[112],"microreservoir":[114],"achieves":[116],"targeted":[118],"application.":[119]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":2},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
