{"id":"https://openalex.org/W2918342081","doi":"https://doi.org/10.1109/tencon.2018.8650244","title":"A Study on Modeling and Verification of the Percentage Differential Relay for the Protection of AC Electric Railway Feeding System","display_name":"A Study on Modeling and Verification of the Percentage Differential Relay for the Protection of AC Electric Railway Feeding System","publication_year":2018,"publication_date":"2018-10-01","ids":{"openalex":"https://openalex.org/W2918342081","doi":"https://doi.org/10.1109/tencon.2018.8650244","mag":"2918342081"},"language":"en","primary_location":{"id":"doi:10.1109/tencon.2018.8650244","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tencon.2018.8650244","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"TENCON 2018 - 2018 IEEE Region 10 Conference","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5046476505","display_name":"Gyu\u2010Jung Cho","orcid":"https://orcid.org/0000-0002-2791-5361"},"institutions":[{"id":"https://openalex.org/I848706","display_name":"Sungkyunkwan University","ror":"https://ror.org/04q78tk20","country_code":"KR","type":"education","lineage":["https://openalex.org/I848706"]}],"countries":["KR"],"is_corresponding":true,"raw_author_name":"Gyu-Jung Cho","raw_affiliation_strings":["College of Information and Communication Engineering, Sungkyunkwan University, Suwon, Republic of Korea"],"affiliations":[{"raw_affiliation_string":"College of Information and Communication Engineering, Sungkyunkwan University, Suwon, Republic of Korea","institution_ids":["https://openalex.org/I848706"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100394486","display_name":"Minsung Kim","orcid":"https://orcid.org/0000-0002-3297-9466"},"institutions":[{"id":"https://openalex.org/I848706","display_name":"Sungkyunkwan University","ror":"https://ror.org/04q78tk20","country_code":"KR","type":"education","lineage":["https://openalex.org/I848706"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Min-Sung Kim","raw_affiliation_strings":["College of Information and Communication Engineering, Sungkyunkwan University, Suwon, Republic of Korea"],"affiliations":[{"raw_affiliation_string":"College of Information and Communication Engineering, Sungkyunkwan University, Suwon, Republic of Korea","institution_ids":["https://openalex.org/I848706"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100454667","display_name":"Dong-Hyun Kim","orcid":"https://orcid.org/0000-0002-2239-1757"},"institutions":[{"id":"https://openalex.org/I848706","display_name":"Sungkyunkwan University","ror":"https://ror.org/04q78tk20","country_code":"KR","type":"education","lineage":["https://openalex.org/I848706"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Dong-Hyun Kim","raw_affiliation_strings":["College of Information and Communication Engineering, Sungkyunkwan University, Suwon, Republic of Korea"],"affiliations":[{"raw_affiliation_string":"College of Information and Communication Engineering, Sungkyunkwan University, Suwon, Republic of Korea","institution_ids":["https://openalex.org/I848706"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5018905527","display_name":"Chul\u2010Hwan Kim","orcid":"https://orcid.org/0000-0002-3418-9687"},"institutions":[{"id":"https://openalex.org/I848706","display_name":"Sungkyunkwan University","ror":"https://ror.org/04q78tk20","country_code":"KR","type":"education","lineage":["https://openalex.org/I848706"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Chul-Hwan Kim","raw_affiliation_strings":["College of Information and Communication Engineering, Sungkyunkwan University, Suwon, Republic of Korea"],"affiliations":[{"raw_affiliation_string":"College of Information and Communication Engineering, Sungkyunkwan University, Suwon, Republic of Korea","institution_ids":["https://openalex.org/I848706"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5046476505"],"corresponding_institution_ids":["https://openalex.org/I848706"],"apc_list":null,"apc_paid":null,"fwci":0.4927,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.74909709,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"0752","last_page":"0756"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11568","display_name":"Railway Systems and Energy Efficiency","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2209","display_name":"Industrial and Manufacturing Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11568","display_name":"Railway Systems and Energy Efficiency","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2209","display_name":"Industrial and Manufacturing Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12371","display_name":"Electrical Contact Performance and Analysis","score":0.9983999729156494,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.991599977016449,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/relay","display_name":"Relay","score":0.8102507591247559},{"id":"https://openalex.org/keywords/autotransformer","display_name":"Autotransformer","score":0.8071415424346924},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.7063536643981934},{"id":"https://openalex.org/keywords/differential-protection","display_name":"Differential protection","score":0.6994260549545288},{"id":"https://openalex.org/keywords/protective-relay","display_name":"Protective relay","score":0.6399503350257874},{"id":"https://openalex.org/keywords/current-transformer","display_name":"Current transformer","score":0.5964056253433228},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.5346720814704895},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.46352487802505493},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.44320595264434814},{"id":"https://openalex.org/keywords/single-phase-electric-power","display_name":"Single-phase electric power","score":0.4259589612483978},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.3605912923812866},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.33902961015701294},{"id":"https://openalex.org/keywords/distribution-transformer","display_name":"Distribution transformer","score":0.3034060001373291},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.2168133556842804},{"id":"https://openalex.org/keywords/power-factor","display_name":"Power factor","score":0.10580387711524963},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.096363365650177}],"concepts":[{"id":"https://openalex.org/C2778156585","wikidata":"https://www.wikidata.org/wiki/Q174053","display_name":"Relay","level":3,"score":0.8102507591247559},{"id":"https://openalex.org/C22958824","wikidata":"https://www.wikidata.org/wiki/Q565668","display_name":"Autotransformer","level":5,"score":0.8071415424346924},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.7063536643981934},{"id":"https://openalex.org/C2986957705","wikidata":"https://www.wikidata.org/wiki/Q1756067","display_name":"Differential protection","level":4,"score":0.6994260549545288},{"id":"https://openalex.org/C2412688","wikidata":"https://www.wikidata.org/wiki/Q503732","display_name":"Protective relay","level":4,"score":0.6399503350257874},{"id":"https://openalex.org/C133770746","wikidata":"https://www.wikidata.org/wiki/Q856535","display_name":"Current transformer","level":4,"score":0.5964056253433228},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5346720814704895},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.46352487802505493},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.44320595264434814},{"id":"https://openalex.org/C50825304","wikidata":"https://www.wikidata.org/wiki/Q260295","display_name":"Single-phase electric power","level":4,"score":0.4259589612483978},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3605912923812866},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.33902961015701294},{"id":"https://openalex.org/C117323899","wikidata":"https://www.wikidata.org/wiki/Q1907989","display_name":"Distribution transformer","level":4,"score":0.3034060001373291},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.2168133556842804},{"id":"https://openalex.org/C64424096","wikidata":"https://www.wikidata.org/wiki/Q750454","display_name":"Power factor","level":3,"score":0.10580387711524963},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.096363365650177},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tencon.2018.8650244","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tencon.2018.8650244","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"TENCON 2018 - 2018 IEEE Region 10 Conference","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":11,"referenced_works":["https://openalex.org/W1967164724","https://openalex.org/W2008603248","https://openalex.org/W2033830424","https://openalex.org/W2054553437","https://openalex.org/W2085764105","https://openalex.org/W2090501296","https://openalex.org/W2121345140","https://openalex.org/W2167830456","https://openalex.org/W2531809907","https://openalex.org/W3216219169","https://openalex.org/W4240682246"],"related_works":["https://openalex.org/W3111144073","https://openalex.org/W2159213599","https://openalex.org/W2000393691","https://openalex.org/W2766679694","https://openalex.org/W2004160601","https://openalex.org/W2012956716","https://openalex.org/W2168125565","https://openalex.org/W2393057729","https://openalex.org/W2913881086","https://openalex.org/W1826827391"],"abstract_inverted_index":{"In":[0,19,42],"general,":[1],"a":[2,27,44,106],"Scott-transformer":[3],"is":[4,48,73,112],"used":[5],"to":[6,31,101,105],"supply":[7],"the":[8,12,21,55,63,66,85,109],"single-phase":[9],"power":[10],"for":[11,53,62,89],"Korean":[13,22,67],"AC":[14,68,90],"electric":[15,69,91],"railway":[16,70,92],"feeding":[17,24,71,93],"system.":[18],"particular,":[20],"Autotransformer":[23],"system":[25,72,94],"has":[26,38],"different":[28],"configuration":[29],"compared":[30],"those":[32],"of":[33,108],"other":[34],"countries,":[35],"therefore,":[36],"it":[37],"certain":[39],"distinctive":[40],"characteristics.":[41],"addition,":[43],"percentage":[45,86],"differential":[46,87],"relay":[47,64,88],"widely":[49],"and":[50,60,83],"globally":[51],"utilized":[52],"protecting":[54,65],"transformers.":[56],"However,":[57],"detailed":[58],"modeling":[59],"simulation":[61],"not":[74],"performed":[75],"enough.":[76],"Thus,":[77],"in":[78],"this":[79],"paper,":[80],"we":[81],"modeled":[82],"verified":[84],"by":[95],"using":[96],"PSCAD/EMTDC.":[97],"A":[98],"simple":[99],"method":[100],"prevent":[102],"malfunction":[103],"due":[104],"saturation":[107],"current":[110],"transformer":[111],"suggested":[113],"as":[114],"well.":[115]},"counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2020,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
