{"id":"https://openalex.org/W4319865470","doi":"https://doi.org/10.1109/tcst.2023.3239426","title":"Diagnosis and Fault-Tolerant Control of Permanent Magnet Synchronous Motors With Interturn Short-Circuit Fault","display_name":"Diagnosis and Fault-Tolerant Control of Permanent Magnet Synchronous Motors With Interturn Short-Circuit Fault","publication_year":2023,"publication_date":"2023-01-31","ids":{"openalex":"https://openalex.org/W4319865470","doi":"https://doi.org/10.1109/tcst.2023.3239426"},"language":"en","primary_location":{"id":"doi:10.1109/tcst.2023.3239426","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tcst.2023.3239426","pdf_url":null,"source":{"id":"https://openalex.org/S133363738","display_name":"IEEE Transactions on Control Systems Technology","issn_l":"1063-6536","issn":["1063-6536","1558-0865","2374-0159"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Control Systems Technology","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100661885","display_name":"Jiayuan Zhang","orcid":"https://orcid.org/0000-0002-1985-2938"},"institutions":[{"id":"https://openalex.org/I1299951241","display_name":"Caterpillar (United States)","ror":"https://ror.org/01qhm7e49","country_code":"US","type":"company","lineage":["https://openalex.org/I1299951241"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Jiayuan Zhang","raw_affiliation_strings":["Caterpillar, Peoria, IL, USA"],"affiliations":[{"raw_affiliation_string":"Caterpillar, Peoria, IL, USA","institution_ids":["https://openalex.org/I1299951241"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101845516","display_name":"Wei Zhan","orcid":"https://orcid.org/0000-0002-9956-1910"},"institutions":[{"id":"https://openalex.org/I91045830","display_name":"Texas A&M University","ror":"https://ror.org/01f5ytq51","country_code":"US","type":"education","lineage":["https://openalex.org/I91045830"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Wei Zhan","raw_affiliation_strings":["Department of Engineering Technology and Industrial Distribution, Texas A&#x0026;M University, College Station, TX, USA"],"affiliations":[{"raw_affiliation_string":"Department of Engineering Technology and Industrial Distribution, Texas A&#x0026;M University, College Station, TX, USA","institution_ids":["https://openalex.org/I91045830"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5069823705","display_name":"M. Ehsani","orcid":"https://orcid.org/0000-0002-1701-1713"},"institutions":[{"id":"https://openalex.org/I91045830","display_name":"Texas A&M University","ror":"https://ror.org/01f5ytq51","country_code":"US","type":"education","lineage":["https://openalex.org/I91045830"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Mehrdad Ehsani","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Texas A&#x0026;M University, College Station, TX, USA"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Texas A&#x0026;M University, College Station, TX, USA","institution_ids":["https://openalex.org/I91045830"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5100661885"],"corresponding_institution_ids":["https://openalex.org/I1299951241"],"apc_list":null,"apc_paid":null,"fwci":3.1066,"has_fulltext":false,"cited_by_count":17,"citation_normalized_percentile":{"value":0.91479875,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":97,"max":99},"biblio":{"volume":"31","issue":"4","first_page":"1909","last_page":"1916"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.9976999759674072,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9973000288009644,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.7007532119750977},{"id":"https://openalex.org/keywords/fault-tolerance","display_name":"Fault tolerance","score":0.668075442314148},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.6667888164520264},{"id":"https://openalex.org/keywords/torque","display_name":"Torque","score":0.6460930705070496},{"id":"https://openalex.org/keywords/permanent-magnet-synchronous-motor","display_name":"Permanent magnet synchronous motor","score":0.4777851998806},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.46254274249076843},{"id":"https://openalex.org/keywords/short-circuit","display_name":"Short circuit","score":0.46145498752593994},{"id":"https://openalex.org/keywords/direct-torque-control","display_name":"Direct torque control","score":0.45082637667655945},{"id":"https://openalex.org/keywords/magnet","display_name":"Magnet","score":0.44437286257743835},{"id":"https://openalex.org/keywords/synchronous-motor","display_name":"Synchronous motor","score":0.41766321659088135},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3851725161075592},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.37394171953201294},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.32871901988983154},{"id":"https://openalex.org/keywords/induction-motor","display_name":"Induction motor","score":0.2606624960899353},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.16049203276634216},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.14589649438858032},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.12645041942596436},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.07798010110855103},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.07497888803482056}],"concepts":[{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.7007532119750977},{"id":"https://openalex.org/C63540848","wikidata":"https://www.wikidata.org/wiki/Q3140932","display_name":"Fault tolerance","level":2,"score":0.668075442314148},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6667888164520264},{"id":"https://openalex.org/C144171764","wikidata":"https://www.wikidata.org/wiki/Q48103","display_name":"Torque","level":2,"score":0.6460930705070496},{"id":"https://openalex.org/C2986944758","wikidata":"https://www.wikidata.org/wiki/Q845675","display_name":"Permanent magnet synchronous motor","level":3,"score":0.4777851998806},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.46254274249076843},{"id":"https://openalex.org/C68583231","wikidata":"https://www.wikidata.org/wiki/Q206907","display_name":"Short circuit","level":3,"score":0.46145498752593994},{"id":"https://openalex.org/C109871850","wikidata":"https://www.wikidata.org/wiki/Q1227571","display_name":"Direct torque control","level":4,"score":0.45082637667655945},{"id":"https://openalex.org/C16389437","wikidata":"https://www.wikidata.org/wiki/Q11421","display_name":"Magnet","level":2,"score":0.44437286257743835},{"id":"https://openalex.org/C71376005","wikidata":"https://www.wikidata.org/wiki/Q845675","display_name":"Synchronous motor","level":2,"score":0.41766321659088135},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3851725161075592},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.37394171953201294},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.32871901988983154},{"id":"https://openalex.org/C80962145","wikidata":"https://www.wikidata.org/wiki/Q207450","display_name":"Induction motor","level":3,"score":0.2606624960899353},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.16049203276634216},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.14589649438858032},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.12645041942596436},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.07798010110855103},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.07497888803482056},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tcst.2023.3239426","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tcst.2023.3239426","pdf_url":null,"source":{"id":"https://openalex.org/S133363738","display_name":"IEEE Transactions on Control Systems Technology","issn_l":"1063-6536","issn":["1063-6536","1558-0865","2374-0159"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Control Systems Technology","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":40,"referenced_works":["https://openalex.org/W2003333103","https://openalex.org/W2003574569","https://openalex.org/W2005580246","https://openalex.org/W2010727011","https://openalex.org/W2020495941","https://openalex.org/W2033802545","https://openalex.org/W2041146270","https://openalex.org/W2062026092","https://openalex.org/W2080179645","https://openalex.org/W2101218171","https://openalex.org/W2104093141","https://openalex.org/W2131789431","https://openalex.org/W2142632891","https://openalex.org/W2145223406","https://openalex.org/W2152128485","https://openalex.org/W2153202281","https://openalex.org/W2163365215","https://openalex.org/W2167610686","https://openalex.org/W2169582464","https://openalex.org/W2175322757","https://openalex.org/W2332197718","https://openalex.org/W2337532410","https://openalex.org/W2399122540","https://openalex.org/W2461185357","https://openalex.org/W2474672191","https://openalex.org/W2518550369","https://openalex.org/W2519223725","https://openalex.org/W2555558587","https://openalex.org/W2592087115","https://openalex.org/W2610954082","https://openalex.org/W2783819238","https://openalex.org/W2788037565","https://openalex.org/W2797944864","https://openalex.org/W2888133611","https://openalex.org/W2969715697","https://openalex.org/W3118143618","https://openalex.org/W4225266513","https://openalex.org/W4233898916","https://openalex.org/W4283012675","https://openalex.org/W6838706888"],"related_works":["https://openalex.org/W2380800335","https://openalex.org/W2367230668","https://openalex.org/W4252156693","https://openalex.org/W2615749722","https://openalex.org/W2355594986","https://openalex.org/W2087042126","https://openalex.org/W4242196303","https://openalex.org/W2144803608","https://openalex.org/W2082330079","https://openalex.org/W2547026369"],"abstract_inverted_index":{"In":[0],"this":[1,30],"brief,":[2],"a":[3,52],"hidden":[4],"Markov":[5],"model":[6],"(HMM)":[7],"is":[8,32,56],"used":[9],"to":[10,58,104],"diagnose":[11],"the":[12,42,50,70,81,92,96],"severity":[13,44],"of":[14,35,49,69,100],"permanent":[15],"magnet":[16],"synchronous":[17],"motors":[18],"(PMSMs)":[19],"with":[20,91],"interturn":[21],"short-circuit":[22],"(SC)":[23],"fault.":[24],"The":[25,67,98],"fault":[26,43],"diagnosis":[27],"result":[28,37],"in":[29,80,95,107],"brief":[31],"an":[33],"extension":[34],"similar":[36],"for":[38,46],"dc":[39],"motors.":[40],"When":[41],"allows":[45],"continuing":[47],"operation":[48],"motor,":[51],"bisecting":[53],"search":[54],"method":[55,75],"proposed":[57],"reduce":[59],"torque":[60,65],"ripples":[61,86],"while":[62],"maintaining":[63],"maximum":[64],"capability.":[66],"advantages":[68],"new":[71],"fault-tolerant":[72],"control":[73],"(FTC)":[74],"over":[76],"other":[77],"existing":[78,93],"methods":[79],"literature":[82],"are":[83,87],"analyzed.":[84],"Torque":[85],"significantly":[88],"reduced":[89],"compared":[90],"FTCs":[94],"literature.":[97],"assumption":[99],"SC":[101],"resistance":[102],"equal":[103],"zero":[105],"made":[106],"another":[108],"paper":[109],"was":[110],"eliminated.":[111]},"counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2025,"cited_by_count":6},{"year":2024,"cited_by_count":5},{"year":2023,"cited_by_count":4}],"updated_date":"2026-04-01T17:29:45.350535","created_date":"2025-10-10T00:00:00"}
