{"id":"https://openalex.org/W2898120682","doi":"https://doi.org/10.1109/tcsii.2018.2878042","title":"Instantaneous Power Consuming Level Shifter for Improving Power Conversion Efficiency of Buck Converter","display_name":"Instantaneous Power Consuming Level Shifter for Improving Power Conversion Efficiency of Buck Converter","publication_year":2018,"publication_date":"2018-10-25","ids":{"openalex":"https://openalex.org/W2898120682","doi":"https://doi.org/10.1109/tcsii.2018.2878042","mag":"2898120682"},"language":"en","primary_location":{"id":"doi:10.1109/tcsii.2018.2878042","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tcsii.2018.2878042","pdf_url":null,"source":{"id":"https://openalex.org/S93916849","display_name":"IEEE Transactions on Circuits & Systems II Express Briefs","issn_l":"1549-7747","issn":["1549-7747","1558-3791"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Circuits and Systems II: Express Briefs","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5067311469","display_name":"Hyunggun Ma","orcid":"https://orcid.org/0000-0002-2976-7315"},"institutions":[{"id":"https://openalex.org/I48566637","display_name":"Ulsan National Institute of Science and Technology","ror":"https://ror.org/017cjz748","country_code":"KR","type":"education","lineage":["https://openalex.org/I48566637"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Hyunggun Ma","raw_affiliation_strings":["School of Electrical and Computer Engineering, Ulsan National Institute of Science and Technology, Ulsan, South Korea"],"raw_orcid":"https://orcid.org/0000-0002-2976-7315","affiliations":[{"raw_affiliation_string":"School of Electrical and Computer Engineering, Ulsan National Institute of Science and Technology, Ulsan, South Korea","institution_ids":["https://openalex.org/I48566637"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5000157558","display_name":"Gyeongho Namgoong","orcid":"https://orcid.org/0000-0001-5326-2897"},"institutions":[{"id":"https://openalex.org/I48566637","display_name":"Ulsan National Institute of Science and Technology","ror":"https://ror.org/017cjz748","country_code":"KR","type":"education","lineage":["https://openalex.org/I48566637"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Gyeongho Namgoong","raw_affiliation_strings":["School of Electrical and Computer Engineering, Ulsan National Institute of Science and Technology, Ulsan, South Korea"],"raw_orcid":"https://orcid.org/0000-0001-5326-2897","affiliations":[{"raw_affiliation_string":"School of Electrical and Computer Engineering, Ulsan National Institute of Science and Technology, Ulsan, South Korea","institution_ids":["https://openalex.org/I48566637"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5001040595","display_name":"Eun-Ho Choi","orcid":"https://orcid.org/0000-0003-3996-6585"},"institutions":[{"id":"https://openalex.org/I48566637","display_name":"Ulsan National Institute of Science and Technology","ror":"https://ror.org/017cjz748","country_code":"KR","type":"education","lineage":["https://openalex.org/I48566637"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Eunho Choi","raw_affiliation_strings":["School of Electrical and Computer Engineering, Ulsan National Institute of Science and Technology, Ulsan, South Korea"],"raw_orcid":"https://orcid.org/0000-0003-3996-6585","affiliations":[{"raw_affiliation_string":"School of Electrical and Computer Engineering, Ulsan National Institute of Science and Technology, Ulsan, South Korea","institution_ids":["https://openalex.org/I48566637"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5058339861","display_name":"Franklin Bien","orcid":"https://orcid.org/0000-0002-9582-295X"},"institutions":[{"id":"https://openalex.org/I48566637","display_name":"Ulsan National Institute of Science and Technology","ror":"https://ror.org/017cjz748","country_code":"KR","type":"education","lineage":["https://openalex.org/I48566637"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Franklin Bien","raw_affiliation_strings":["School of Electrical and Computer Engineering, Ulsan National Institute of Science and Technology, Ulsan, South Korea"],"raw_orcid":"https://orcid.org/0000-0002-9582-295X","affiliations":[{"raw_affiliation_string":"School of Electrical and Computer Engineering, Ulsan National Institute of Science and Technology, Ulsan, South Korea","institution_ids":["https://openalex.org/I48566637"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I48566637"],"apc_list":null,"apc_paid":null,"fwci":0.7857,"has_fulltext":false,"cited_by_count":14,"citation_normalized_percentile":{"value":0.74695987,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":"66","issue":"7","first_page":"1207","last_page":"1211"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11249","display_name":"Wireless Power Transfer Systems","score":0.9980000257492065,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10663","display_name":"Advanced Battery Technologies Research","score":0.9937000274658203,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/logic-level","display_name":"Logic level","score":0.7105523943901062},{"id":"https://openalex.org/keywords/buck-converter","display_name":"Buck converter","score":0.6647462844848633},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.5898462533950806},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.5620145201683044},{"id":"https://openalex.org/keywords/capacitor","display_name":"Capacitor","score":0.5488120913505554},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.45329752564430237},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.4442768096923828},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3336348831653595},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3268960416316986},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.15229415893554688}],"concepts":[{"id":"https://openalex.org/C146569638","wikidata":"https://www.wikidata.org/wiki/Q173378","display_name":"Logic level","level":3,"score":0.7105523943901062},{"id":"https://openalex.org/C150818752","wikidata":"https://www.wikidata.org/wiki/Q83804","display_name":"Buck converter","level":3,"score":0.6647462844848633},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.5898462533950806},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5620145201683044},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.5488120913505554},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.45329752564430237},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4442768096923828},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3336348831653595},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3268960416316986},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.15229415893554688},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/tcsii.2018.2878042","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tcsii.2018.2878042","pdf_url":null,"source":{"id":"https://openalex.org/S93916849","display_name":"IEEE Transactions on Circuits & Systems II Express Briefs","issn_l":"1549-7747","issn":["1549-7747","1558-3791"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Circuits and Systems II: Express Briefs","raw_type":"journal-article"},{"id":"pmh:oai:scholarworks.unist.ac.kr:201301/25507","is_oa":false,"landing_page_url":"https://scholarworks.unist.ac.kr/handle/201301/25507","pdf_url":null,"source":{"id":"https://openalex.org/S4306401118","display_name":"Scholarworks@UNIST (Ulsan National Institute of Science and Technology)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I48566637","host_organization_name":"Ulsan National Institute of Science and Technology","host_organization_lineage":["https://openalex.org/I48566637"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"ARTICLE"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.9100000262260437,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[{"id":"https://openalex.org/G8457556697","display_name":null,"funder_award_id":"NRF-2017R1A5A1015596","funder_id":"https://openalex.org/F4320322120","funder_display_name":"National Research Foundation of Korea"}],"funders":[{"id":"https://openalex.org/F4320322120","display_name":"National Research Foundation of Korea","ror":"https://ror.org/013aysd81"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":11,"referenced_works":["https://openalex.org/W1964434038","https://openalex.org/W1968198809","https://openalex.org/W2085047061","https://openalex.org/W2127238426","https://openalex.org/W2130324138","https://openalex.org/W2135816270","https://openalex.org/W2151169570","https://openalex.org/W2153430703","https://openalex.org/W2167469160","https://openalex.org/W2275509161","https://openalex.org/W6694503959"],"related_works":["https://openalex.org/W4398198689","https://openalex.org/W2354365353","https://openalex.org/W2811287415","https://openalex.org/W1988437325","https://openalex.org/W2354835317","https://openalex.org/W2171140818","https://openalex.org/W2130152888","https://openalex.org/W2356735381","https://openalex.org/W2163294767","https://openalex.org/W1951306855"],"abstract_inverted_index":{"An":[0,66,83],"instantaneous":[1],"power":[2,25,43,63,105],"consuming":[3],"level":[4,18,40,57,75,98,110,132],"shifter":[5,19,41,58,76,111],"is":[6,20,34,52,70,90,136],"presented":[7],"in":[8,22,36],"this":[9],"brief":[10],"to":[11,28,54,60,72,92,126,161],"increase":[12],"the":[13,30,46,56,62,74,80,94,97,104,108,116,121,139,155],"dc":[14],"converter":[15,89,117,135],"efficiency.":[16],"The":[17,39,134],"used":[21,35,53],"a":[23,130],"high-side":[24],"switch":[26],"driver":[27],"remove":[29],"external":[31],"capacitor":[32],"which":[33],"bootstrap":[37],"technique.":[38],"consumes":[42],"only":[44],"during":[45],"transition":[47],"period.":[48,65],"A":[49],"delay":[50,81],"cell":[51],"turn":[55,73],"off":[59,77],"reduce":[61],"consumption":[64,106],"output":[67,167],"voltage":[68,168],"detector":[69],"added":[71],"even":[78],"before":[79],"time.":[82],"asynchronous":[84],"discontinuous":[85],"conduction":[86],"mode":[87],"buck":[88],"designed":[91],"verify":[93],"performance":[95],"of":[96,107,123,151,169],"shifter.":[99,133],"Simulation":[100],"results":[101,127],"show":[102],"that":[103],"proposed":[109],"decreased":[112],"by":[113,120],"66%,":[114],"while":[115],"efficiency":[118],"increased":[119],"maximum":[122],"9%":[124],"compared":[125],"obtained":[128],"for":[129],"conventional":[131],"fabricated":[137],"using":[138],"TSMC":[140],"0.18-\u03bcm":[141],"BCD":[142],"process":[143],"and":[144,164],"it":[145],"operates":[146],"within":[147],"an":[148,166],"input":[149],"range":[150],"2-5":[152],"V":[153],"when":[154],"current":[156],"varies":[157],"from":[158],"400":[159],"\u03bcA":[160],"18":[162],"mA":[163],"delivers":[165],"1.8":[170],"V.":[171]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":3},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":3},{"year":2021,"cited_by_count":3},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":2}],"updated_date":"2026-06-26T08:34:08.712188","created_date":"2025-10-10T00:00:00"}
