{"id":"https://openalex.org/W2734510350","doi":"https://doi.org/10.1109/tcsi.2017.2719283","title":"Parallel Balanced-Bit-Serial Design Technique for Ultra-Low-Voltage Circuits With Energy Saving and Area Efficiency Enhancement","display_name":"Parallel Balanced-Bit-Serial Design Technique for Ultra-Low-Voltage Circuits With Energy Saving and Area Efficiency Enhancement","publication_year":2017,"publication_date":"2017-07-14","ids":{"openalex":"https://openalex.org/W2734510350","doi":"https://doi.org/10.1109/tcsi.2017.2719283","mag":"2734510350"},"language":"en","primary_location":{"id":"doi:10.1109/tcsi.2017.2719283","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tcsi.2017.2719283","pdf_url":null,"source":{"id":"https://openalex.org/S116977442","display_name":"IEEE Transactions on Circuits and Systems I Regular Papers","issn_l":"1549-8328","issn":["1549-8328","1558-0806"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Circuits and Systems I: Regular Papers","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5046442535","display_name":"Bing-Chen Wu","orcid":"https://orcid.org/0000-0002-7451-4261"},"institutions":[{"id":"https://openalex.org/I16733864","display_name":"National Taiwan University","ror":"https://ror.org/05bqach95","country_code":"TW","type":"education","lineage":["https://openalex.org/I16733864"]},{"id":"https://openalex.org/I173093425","display_name":"Chang Gung University","ror":"https://ror.org/00d80zx46","country_code":"TW","type":"education","lineage":["https://openalex.org/I173093425"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Bing-Chen Wu","raw_affiliation_strings":["Graduate Institute of Electrical Engineering, Chang Gung University, Tao-Yuan, Taiwan","Graduate Institute of Electronics Engineering and the Department of Electrical Engineering, National Taiwan University, Taipei, Taiwan"],"raw_orcid":"https://orcid.org/0000-0002-7451-4261","affiliations":[{"raw_affiliation_string":"Graduate Institute of Electrical Engineering, Chang Gung University, Tao-Yuan, Taiwan","institution_ids":["https://openalex.org/I173093425"]},{"raw_affiliation_string":"Graduate Institute of Electronics Engineering and the Department of Electrical Engineering, National Taiwan University, Taipei, Taiwan","institution_ids":["https://openalex.org/I16733864"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5005575420","display_name":"I\u2010Chyn Wey","orcid":"https://orcid.org/0000-0003-3412-6958"},"institutions":[{"id":"https://openalex.org/I141243467","display_name":"Chang Gung University of Science and Technology","ror":"https://ror.org/009knm296","country_code":"TW","type":"education","lineage":["https://openalex.org/I141243467"]},{"id":"https://openalex.org/I3020100970","display_name":"Chang Gung Memorial Hospital","ror":"https://ror.org/02verss31","country_code":"TW","type":"healthcare","lineage":["https://openalex.org/I3020100970"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"I-Chyn Wey","raw_affiliation_strings":["Department of Neurology, Chang Gung Memorial Hospital, Tao-Yuan, Taiwan","Green Technology Research Center, Centre for Reliability Sciences and Technologies, Electrical Engineering Department, Graduate Institute of Electrical Engineering, Chang Gung University, Tao-Yuan, Taiwan"],"raw_orcid":"https://orcid.org/0000-0003-3412-6958","affiliations":[{"raw_affiliation_string":"Department of Neurology, Chang Gung Memorial Hospital, Tao-Yuan, Taiwan","institution_ids":["https://openalex.org/I3020100970"]},{"raw_affiliation_string":"Green Technology Research Center, Centre for Reliability Sciences and Technologies, Electrical Engineering Department, Graduate Institute of Electrical Engineering, Chang Gung University, Tao-Yuan, Taiwan","institution_ids":["https://openalex.org/I141243467"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.5848,"has_fulltext":false,"cited_by_count":6,"citation_normalized_percentile":{"value":0.69765124,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":97},"biblio":{"volume":"65","issue":"1","first_page":"141","last_page":"153"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10363","display_name":"Low-power high-performance VLSI design","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10363","display_name":"Low-power high-performance VLSI design","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10054","display_name":"Parallel Computing and Optimization Techniques","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/1708","display_name":"Hardware and Architecture"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10829","display_name":"Interconnection Networks and Systems","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7487142086029053},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.6338390707969666},{"id":"https://openalex.org/keywords/critical-path-method","display_name":"Critical path method","score":0.588988184928894},{"id":"https://openalex.org/keywords/adder","display_name":"Adder","score":0.5672906041145325},{"id":"https://openalex.org/keywords/subtractor","display_name":"Subtractor","score":0.5184609293937683},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.488474041223526},{"id":"https://openalex.org/keywords/parallel-computing","display_name":"Parallel computing","score":0.47726815938949585},{"id":"https://openalex.org/keywords/simd","display_name":"SIMD","score":0.46519386768341064},{"id":"https://openalex.org/keywords/serialization","display_name":"Serialization","score":0.44040581583976746},{"id":"https://openalex.org/keywords/register-file","display_name":"Register file","score":0.4345177710056305},{"id":"https://openalex.org/keywords/overhead","display_name":"Overhead (engineering)","score":0.4259808659553528},{"id":"https://openalex.org/keywords/computer-hardware","display_name":"Computer hardware","score":0.40009865164756775},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.32166287302970886},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.20960980653762817},{"id":"https://openalex.org/keywords/instruction-set","display_name":"Instruction set","score":0.1432408094406128},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.13278543949127197},{"id":"https://openalex.org/keywords/latency","display_name":"Latency (audio)","score":0.10843092203140259},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.10206913948059082}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7487142086029053},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.6338390707969666},{"id":"https://openalex.org/C115874739","wikidata":"https://www.wikidata.org/wiki/Q825377","display_name":"Critical path method","level":2,"score":0.588988184928894},{"id":"https://openalex.org/C164620267","wikidata":"https://www.wikidata.org/wiki/Q376953","display_name":"Adder","level":3,"score":0.5672906041145325},{"id":"https://openalex.org/C187805909","wikidata":"https://www.wikidata.org/wiki/Q1142401","display_name":"Subtractor","level":4,"score":0.5184609293937683},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.488474041223526},{"id":"https://openalex.org/C173608175","wikidata":"https://www.wikidata.org/wiki/Q232661","display_name":"Parallel computing","level":1,"score":0.47726815938949585},{"id":"https://openalex.org/C150552126","wikidata":"https://www.wikidata.org/wiki/Q339387","display_name":"SIMD","level":2,"score":0.46519386768341064},{"id":"https://openalex.org/C52723943","wikidata":"https://www.wikidata.org/wiki/Q1127410","display_name":"Serialization","level":2,"score":0.44040581583976746},{"id":"https://openalex.org/C117280010","wikidata":"https://www.wikidata.org/wiki/Q180944","display_name":"Register file","level":3,"score":0.4345177710056305},{"id":"https://openalex.org/C2779960059","wikidata":"https://www.wikidata.org/wiki/Q7113681","display_name":"Overhead (engineering)","level":2,"score":0.4259808659553528},{"id":"https://openalex.org/C9390403","wikidata":"https://www.wikidata.org/wiki/Q3966","display_name":"Computer hardware","level":1,"score":0.40009865164756775},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.32166287302970886},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.20960980653762817},{"id":"https://openalex.org/C202491316","wikidata":"https://www.wikidata.org/wiki/Q272683","display_name":"Instruction set","level":2,"score":0.1432408094406128},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.13278543949127197},{"id":"https://openalex.org/C82876162","wikidata":"https://www.wikidata.org/wiki/Q17096504","display_name":"Latency (audio)","level":2,"score":0.10843092203140259},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.10206913948059082},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C201995342","wikidata":"https://www.wikidata.org/wiki/Q682496","display_name":"Systems engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tcsi.2017.2719283","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tcsi.2017.2719283","pdf_url":null,"source":{"id":"https://openalex.org/S116977442","display_name":"IEEE Transactions on Circuits and Systems I Regular Papers","issn_l":"1549-8328","issn":["1549-8328","1558-0806"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Circuits and Systems I: Regular Papers","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.8999999761581421,"display_name":"Affordable and clean energy"}],"awards":[{"id":"https://openalex.org/G1707810824","display_name":null,"funder_award_id":"MOST104-2220-E-002-003","funder_id":"https://openalex.org/F4320321040","funder_display_name":"National Science Council"},{"id":"https://openalex.org/G45618513","display_name":null,"funder_award_id":"BMRPA77","funder_id":"https://openalex.org/F4320323441","funder_display_name":"Chang Gung Memorial Hospital, Linkou"},{"id":"https://openalex.org/G5305275294","display_name":null,"funder_award_id":"MOST105-2218-E-002-024","funder_id":"https://openalex.org/F4320321040","funder_display_name":"National Science Council"},{"id":"https://openalex.org/G6237284689","display_name":null,"funder_award_id":"MOST104-2220-E-182-001","funder_id":"https://openalex.org/F4320321040","funder_display_name":"National Science Council"}],"funders":[{"id":"https://openalex.org/F4320321040","display_name":"National Science Council","ror":"https://ror.org/02kv4zf79"},{"id":"https://openalex.org/F4320321524","display_name":"Chang Gung University","ror":"https://ror.org/00d80zx46"},{"id":"https://openalex.org/F4320323441","display_name":"Chang Gung Memorial Hospital, Linkou","ror":"https://ror.org/02dnn6q67"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":41,"referenced_works":["https://openalex.org/W1501488688","https://openalex.org/W1518236483","https://openalex.org/W1897403048","https://openalex.org/W1967171495","https://openalex.org/W1972356182","https://openalex.org/W1974982221","https://openalex.org/W1993093542","https://openalex.org/W2008802978","https://openalex.org/W2008913623","https://openalex.org/W2017216250","https://openalex.org/W2019127714","https://openalex.org/W2058066847","https://openalex.org/W2068372672","https://openalex.org/W2086205576","https://openalex.org/W2087107264","https://openalex.org/W2090853900","https://openalex.org/W2101466451","https://openalex.org/W2102587899","https://openalex.org/W2107103004","https://openalex.org/W2109621823","https://openalex.org/W2111372718","https://openalex.org/W2117648153","https://openalex.org/W2123262270","https://openalex.org/W2127575220","https://openalex.org/W2128748528","https://openalex.org/W2133256259","https://openalex.org/W2155304852","https://openalex.org/W2156667996","https://openalex.org/W2157465781","https://openalex.org/W2159497348","https://openalex.org/W2284377722","https://openalex.org/W2289252105","https://openalex.org/W2289891016","https://openalex.org/W2290132443","https://openalex.org/W2290640736","https://openalex.org/W2292234098","https://openalex.org/W2591811992","https://openalex.org/W4239145761","https://openalex.org/W6675374072","https://openalex.org/W6696451247","https://openalex.org/W6697011429"],"related_works":["https://openalex.org/W4231356583","https://openalex.org/W1593760324","https://openalex.org/W2899905671","https://openalex.org/W2376159383","https://openalex.org/W2351439380","https://openalex.org/W2365228680","https://openalex.org/W2129658276","https://openalex.org/W2069137912","https://openalex.org/W2163611611","https://openalex.org/W2160158100"],"abstract_inverted_index":{"Ultra-low-voltage":[0],"(ULV)":[1],"satisfies":[2],"the":[3,85,92,111,154,171],"energy-constraint":[4],"on-die":[5],"acceleration":[6],"of":[7,65,87,97,117,159],"parallel":[8],"processing":[9,147],"in":[10,104],"battery-powered":[11],"Internet-of-Things":[12],"applications.":[13],"However,":[14],"ULV":[15,50,173],"brings":[16],"serious":[17],"leakage":[18,30],"energy,":[19],"throughput":[20],"reduction,":[21],"and":[22,32,90,94,123,163],"delay":[23,42,75],"variation":[24,43],"issues.":[25],"Parallel":[26],"bit-serialization":[27],"remarkably":[28],"reduces":[29],"energy":[31,115,166],"enhances":[33],"area":[34,93,124,161],"efficiency;":[35],"however,":[36],"extremely":[37],"reduced":[38],"critical":[39],"path":[40],"aggravates":[41],"makes":[44],"bit-serial":[45,113],"operation":[46],"not":[47],"feasible":[48],"to":[49,73,83],"design.":[51],"In":[52,77],"this":[53],"paper,":[54],"we":[55,79,136],"propose":[56,80],"a":[57,62,133,138],"balanced-bit-serial":[58],"adder":[59],"(BBSA)":[60],"as":[61,130,168],"basic":[63],"unit":[64],"parallel-balanced-bit-serialization":[66],"(PBBS)":[67],"operation,":[68],"which":[69],"leverages":[70],"timing":[71,88],"borrowing":[72,89],"mitigate":[74],"variation.":[76],"addition,":[78],"two":[81],"latches":[82],"improve":[84],"effectiveness":[86],"ease":[91],"power":[95],"overhead":[96],"BBSA.":[98],"The":[99,149],"proposed":[100,155],"BBSA":[101,118],"is":[102,119,126],"verified":[103],"TSMC":[105],"40-nm":[106],"CMOS":[107],"technology.":[108],"Compared":[109],"with":[110,170],"flip-flop-based":[112],"adder,":[114],"consumption":[116],"saved":[120],"by":[121,128],"40%":[122],"efficiency":[125,162],"improved":[127],"15%":[129],"well.":[131],"As":[132],"practical":[134],"demonstration,":[135],"present":[137],"reconfigurable":[139],"PBBS":[140],"single":[141],"instruction":[142],"multiple":[143],"data":[144],"(SIMD)":[145],"vector":[146],"tile.":[148,175],"post-layout":[150],"simulation":[151],"shows":[152],"that":[153],"design":[156],"has":[157,164],"advantage":[158],"overall":[160],"significant":[165],"saving":[167],"compared":[169],"state-of-art":[172],"SIMD":[174]},"counts_by_year":[{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":3},{"year":2018,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
