{"id":"https://openalex.org/W4405934811","doi":"https://doi.org/10.1109/tbme.2024.3524374","title":"Greedy Optimization of Sensor Array Geometry for Magnetocardiographic Source Localization","display_name":"Greedy Optimization of Sensor Array Geometry for Magnetocardiographic Source Localization","publication_year":2024,"publication_date":"2024-12-31","ids":{"openalex":"https://openalex.org/W4405934811","doi":"https://doi.org/10.1109/tbme.2024.3524374","pmid":"https://pubmed.ncbi.nlm.nih.gov/40030751"},"language":"en","primary_location":{"id":"doi:10.1109/tbme.2024.3524374","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbme.2024.3524374","pdf_url":null,"source":{"id":"https://openalex.org/S5240358","display_name":"IEEE Transactions on Biomedical Engineering","issn_l":"0018-9294","issn":["0018-9294","1558-2531"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Engineering","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://pmc.ncbi.nlm.nih.gov/articles/PMC12233096/","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5112947264","display_name":"Barry Van Veen","orcid":null},"institutions":[{"id":"https://openalex.org/I135310074","display_name":"University of Wisconsin\u2013Madison","ror":"https://ror.org/01y2jtd41","country_code":"US","type":"education","lineage":["https://openalex.org/I135310074"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Barry Van Veen","raw_affiliation_strings":["Department of Electrical and Computer Engineering, University of Wisconsin-Madison, USA","Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, WI, USA"],"raw_orcid":"https://orcid.org/0009-0003-5632-4725","affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Wisconsin-Madison, USA","institution_ids":["https://openalex.org/I135310074"]},{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, WI, USA","institution_ids":["https://openalex.org/I135310074"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5003680020","display_name":"Matti Stenroos","orcid":null},"institutions":[{"id":"https://openalex.org/I9927081","display_name":"Aalto University","ror":"https://ror.org/020hwjq30","country_code":"FI","type":"education","lineage":["https://openalex.org/I9927081"]}],"countries":["FI"],"is_corresponding":false,"raw_author_name":"Matti Stenroos","raw_affiliation_strings":["Department of Neuroscience and Biomedical Engineering, Aalto University, Finland","Department of Neuroscience and Biomedical Engineering, Aalto University, Espoo, Finland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Neuroscience and Biomedical Engineering, Aalto University, Finland","institution_ids":["https://openalex.org/I9927081"]},{"raw_affiliation_string":"Department of Neuroscience and Biomedical Engineering, Aalto University, Espoo, Finland","institution_ids":["https://openalex.org/I9927081"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5043719821","display_name":"Ronald T. Wakai","orcid":"https://orcid.org/0000-0002-9894-0484"},"institutions":[{"id":"https://openalex.org/I135310074","display_name":"University of Wisconsin\u2013Madison","ror":"https://ror.org/01y2jtd41","country_code":"US","type":"education","lineage":["https://openalex.org/I135310074"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Ronald T. Wakai","raw_affiliation_strings":["Department of Medical Physics, University of Wisconsin-Madison, Madison, WI, USA"],"raw_orcid":"https://orcid.org/0000-0002-9894-0484","affiliations":[{"raw_affiliation_string":"Department of Medical Physics, University of Wisconsin-Madison, Madison, WI, USA","institution_ids":["https://openalex.org/I135310074"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.2254,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.51781881,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":97},"biblio":{"volume":"72","issue":"6","first_page":"1848","last_page":"1857"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11993","display_name":"Atomic and Subatomic Physics Research","score":0.986299991607666,"subfield":{"id":"https://openalex.org/subfields/3107","display_name":"Atomic and Molecular Physics, and Optics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11993","display_name":"Atomic and Subatomic Physics Research","score":0.986299991607666,"subfield":{"id":"https://openalex.org/subfields/3107","display_name":"Atomic and Molecular Physics, and Optics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12692","display_name":"Magnetic Field Sensors Techniques","score":0.0020000000949949026,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12405","display_name":"Characterization and Applications of Magnetic Nanoparticles","score":0.0012000000569969416,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/greedy-algorithm","display_name":"Greedy algorithm","score":0.4767797291278839},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.45842069387435913},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.42667290568351746},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.19378355145454407}],"concepts":[{"id":"https://openalex.org/C51823790","wikidata":"https://www.wikidata.org/wiki/Q504353","display_name":"Greedy algorithm","level":2,"score":0.4767797291278839},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.45842069387435913},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.42667290568351746},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.19378355145454407}],"mesh":[{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D003198","descriptor_name":"Computer Simulation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D003198","descriptor_name":"Computer Simulation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D003198","descriptor_name":"Computer Simulation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D003198","descriptor_name":"Computer Simulation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D003198","descriptor_name":"Computer Simulation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D003198","descriptor_name":"Computer Simulation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D003198","descriptor_name":"Computer Simulation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006321","descriptor_name":"Heart","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006321","descriptor_name":"Heart","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006321","descriptor_name":"Heart","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006321","descriptor_name":"Heart","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006321","descriptor_name":"Heart","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006321","descriptor_name":"Heart","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006321","descriptor_name":"Heart","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D053798","descriptor_name":"Magnetocardiography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D053798","descriptor_name":"Magnetocardiography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D053798","descriptor_name":"Magnetocardiography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D053798","descriptor_name":"Magnetocardiography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D053798","descriptor_name":"Magnetocardiography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D053798","descriptor_name":"Magnetocardiography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D053798","descriptor_name":"Magnetocardiography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D053798","descriptor_name":"Magnetocardiography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D053798","descriptor_name":"Magnetocardiography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D053798","descriptor_name":"Magnetocardiography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D053798","descriptor_name":"Magnetocardiography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D053798","descriptor_name":"Magnetocardiography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D053798","descriptor_name":"Magnetocardiography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D053798","descriptor_name":"Magnetocardiography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D059629","descriptor_name":"Signal-To-Noise Ratio","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D059629","descriptor_name":"Signal-To-Noise Ratio","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D059629","descriptor_name":"Signal-To-Noise Ratio","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D059629","descriptor_name":"Signal-To-Noise Ratio","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D059629","descriptor_name":"Signal-To-Noise Ratio","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D059629","descriptor_name":"Signal-To-Noise Ratio","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D059629","descriptor_name":"Signal-To-Noise Ratio","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":3,"locations":[{"id":"doi:10.1109/tbme.2024.3524374","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbme.2024.3524374","pdf_url":null,"source":{"id":"https://openalex.org/S5240358","display_name":"IEEE Transactions on Biomedical Engineering","issn_l":"0018-9294","issn":["0018-9294","1558-2531"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Engineering","raw_type":"journal-article"},{"id":"pmid:40030751","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/40030751","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE transactions on bio-medical engineering","raw_type":null},{"id":"pmh:oai:pubmedcentral.nih.gov:12233096","is_oa":true,"landing_page_url":"https://pmc.ncbi.nlm.nih.gov/articles/PMC12233096/","pdf_url":null,"source":{"id":"https://openalex.org/S2764455111","display_name":"PubMed Central","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Trans Biomed Eng","raw_type":"Text"}],"best_oa_location":{"id":"pmh:oai:pubmedcentral.nih.gov:12233096","is_oa":true,"landing_page_url":"https://pmc.ncbi.nlm.nih.gov/articles/PMC12233096/","pdf_url":null,"source":{"id":"https://openalex.org/S2764455111","display_name":"PubMed Central","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Trans Biomed Eng","raw_type":"Text"},"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G1002684251","display_name":null,"funder_award_id":"R43 HL165987","funder_id":"https://openalex.org/F4320337338","funder_display_name":"National Heart, Lung, and Blood Institute"},{"id":"https://openalex.org/G1048193236","display_name":"A Wearable Magnetocardiography Imaging System","funder_award_id":"1r43hl165987-01","funder_id":"https://openalex.org/F4320332161","funder_display_name":"National Institutes of Health"},{"id":"https://openalex.org/G2126252833","display_name":null,"funder_award_id":"R44 HL160257","funder_id":"https://openalex.org/F4320337338","funder_display_name":"National Heart, Lung, and Blood Institute"}],"funders":[{"id":"https://openalex.org/F4320332161","display_name":"National Institutes of Health","ror":"https://ror.org/01cwqze88"},{"id":"https://openalex.org/F4320337338","display_name":"National Heart, Lung, and Blood Institute","ror":"https://ror.org/012pb6c26"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":24,"referenced_works":["https://openalex.org/W1963919378","https://openalex.org/W1973244464","https://openalex.org/W1988483898","https://openalex.org/W2010111760","https://openalex.org/W2016739615","https://openalex.org/W2060366056","https://openalex.org/W2069399786","https://openalex.org/W2070100893","https://openalex.org/W2070183748","https://openalex.org/W2078588218","https://openalex.org/W2082451393","https://openalex.org/W2083005795","https://openalex.org/W2083743713","https://openalex.org/W2087661871","https://openalex.org/W2091765444","https://openalex.org/W2092260964","https://openalex.org/W2104646655","https://openalex.org/W2120078534","https://openalex.org/W2402812596","https://openalex.org/W2771630528","https://openalex.org/W2778737972","https://openalex.org/W2965094608","https://openalex.org/W3000396196","https://openalex.org/W3134664738"],"related_works":["https://openalex.org/W4391375266","https://openalex.org/W4387497383","https://openalex.org/W3183948672","https://openalex.org/W3173606202","https://openalex.org/W3110381201","https://openalex.org/W2948807893","https://openalex.org/W2899084033","https://openalex.org/W2778153218","https://openalex.org/W2758277628","https://openalex.org/W1531601525"],"abstract_inverted_index":{"OBJECTIVE:":[0],"Until":[1],"recently,":[2],"magnetocardiography":[3],"(MCG)":[4],"studies":[5],"were":[6,110,144],"performed":[7,111],"using":[8],"SQUID":[9],"systems,":[10],"consisting":[11],"of":[12,16,23,31,52,62,97,105,117,123,133,138,158,187,195,211,218,224,234,245],"a":[13,43,73,89,127,184,201,208,221],"planar":[14],"array":[15,60,228],"sensors":[17,38,139,188,212,219],"with":[18,126],"uniform":[19],"spacing.":[20],"The":[21,50,136,172,193],"introduction":[22],"optically-pumped":[24],"magnetometers":[25],"(OPMs)":[26],"now":[27],"enables":[28],"the":[29,37,58,95,114,118,131,134,141,155,159,168,215,232],"deployment":[30],"large,":[32],"conformal":[33],"arrays,":[34],"in":[35,149],"which":[36],"can":[39,198,230],"be":[40,178],"mounted":[41],"on":[42,81],"wearable":[44],"vest":[45],"at":[46],"nearly":[47],"any":[48],"location.":[49],"objective":[51],"this":[53,196],"study":[54,197],"was":[55,175],"to":[56,83,93,112,121,177],"optimize":[57],"sensor":[59,107],"geometry":[61,129],"an":[63,101],"OPM":[64],"system":[65],"for":[66,77,163,183,203,207,220,239],"MCG":[67,205,236],"imaging":[68,237],"applications.":[69],"METHODS:":[70],"We":[71,86],"devised":[72],"new":[74],"optimization":[75,91,99,182,229],"criterion":[76],"spatial":[78],"resolution":[79],"based":[80],"sensitivity":[82],"localization":[84,115,173,244],"error.":[85],"also":[87],"implemented":[88],"greedy":[90],"technique":[92],"overcome":[94],"difficulty":[96],"combinatoric":[98],"over":[100,130],"extremely":[102],"large":[103],"number":[104,137,186,210,217],"possible":[106],"configurations.":[108],"Simulations":[109],"compare":[113],"accuracy":[116,174],"optimized":[119,162],"arrays":[120,125,206],"that":[122],"conventional":[124],"regular":[128],"front":[132],"torso.":[135,160],"and":[140,189],"signal-to-noise":[142,190],"ratio":[143],"varied.":[145],"RESULTS:":[146],"Optimization":[147],"resulted":[148],"non-planar,":[150],"irregular":[151],"geometries":[152],"biased":[153],"toward":[154],"left":[156],"half":[157],"Arrays":[161],"posterior":[164],"cardiac":[165],"sources":[166],"showed":[167],"best":[169],"overall":[170],"performance.":[171,225],"shown":[176],"significantly":[179],"improved":[180],"by":[181],"given":[185,209,222],"ratio.":[191],"CONCLUSION:":[192],"results":[194],"serve":[199],"as":[200,242],"guide":[202],"designing":[204],"and/or":[213],"determining":[214],"required":[216],"level":[223],"SIGNIFICANCE:":[226],"Sensor":[227],"improve":[231],"performance":[233],"OPM-based":[235],"systems":[238],"applications,":[240],"such":[241],"non-invasive":[243],"arrhythmogenic":[246],"foci.":[247]},"counts_by_year":[{"year":2026,"cited_by_count":1}],"updated_date":"2026-08-06T08:24:18.245995","created_date":"2025-10-10T00:00:00"}