{"id":"https://openalex.org/W4387789697","doi":"https://doi.org/10.1109/tbme.2023.3325910","title":"Transcutaneous Magnet Localizer for a Self-Contained Myokinetic Prosthetic Hand","display_name":"Transcutaneous Magnet Localizer for a Self-Contained Myokinetic Prosthetic Hand","publication_year":2023,"publication_date":"2023-10-19","ids":{"openalex":"https://openalex.org/W4387789697","doi":"https://doi.org/10.1109/tbme.2023.3325910","pmid":"https://pubmed.ncbi.nlm.nih.gov/37856259"},"language":"en","primary_location":{"id":"doi:10.1109/tbme.2023.3325910","is_oa":true,"landing_page_url":"https://doi.org/10.1109/tbme.2023.3325910","pdf_url":"https://ieeexplore.ieee.org/ielx7/10/4359967/10287986.pdf","source":{"id":"https://openalex.org/S5240358","display_name":"IEEE Transactions on Biomedical Engineering","issn_l":"0018-9294","issn":["0018-9294","1558-2531"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Engineering","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":true,"oa_status":"hybrid","oa_url":"https://ieeexplore.ieee.org/ielx7/10/4359967/10287986.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5023692191","display_name":"Valerio Ianniciello","orcid":"https://orcid.org/0000-0002-2756-5162"},"institutions":[{"id":"https://openalex.org/I162290304","display_name":"Scuola Superiore Sant'Anna","ror":"https://ror.org/025602r80","country_code":"IT","type":"education","lineage":["https://openalex.org/I162290304"]},{"id":"https://openalex.org/I4210112163","display_name":"IT+Robotics (Italy)","ror":"https://ror.org/023d8gn94","country_code":"IT","type":"company","lineage":["https://openalex.org/I4210112163"]},{"id":"https://openalex.org/I4210116474","display_name":"Center for Micro-BioRobotics","ror":"https://ror.org/02nbgxg43","country_code":"IT","type":"facility","lineage":["https://openalex.org/I30771326","https://openalex.org/I4210116474"]},{"id":"https://openalex.org/I4210116723","display_name":"Robotics Research (United States)","ror":"https://ror.org/020w2fr77","country_code":"US","type":"company","lineage":["https://openalex.org/I4210116723"]},{"id":"https://openalex.org/I4210136571","display_name":"Medrobotics (United States)","ror":"https://ror.org/03z02zc05","country_code":"US","type":"company","lineage":["https://openalex.org/I4210136571"]}],"countries":["IT","US"],"is_corresponding":false,"raw_author_name":"Valerio Ianniciello","raw_affiliation_strings":["BioRobotics Institute and the Department of Excellence in Robotics and AI, Italy","BioRobotics Institute and the Department of Excellence in Robotics and AI, Scuola Superiore Sant'Anna, Pisa, Italy"],"raw_orcid":"https://orcid.org/0000-0002-2756-5162","affiliations":[{"raw_affiliation_string":"BioRobotics Institute and the Department of Excellence in Robotics and AI, Italy","institution_ids":["https://openalex.org/I4210116474","https://openalex.org/I4210112163","https://openalex.org/I4210116723","https://openalex.org/I4210136571"]},{"raw_affiliation_string":"BioRobotics Institute and the Department of Excellence in Robotics and AI, Scuola Superiore Sant'Anna, Pisa, Italy","institution_ids":["https://openalex.org/I162290304"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5051156362","display_name":"Marta Gherardini","orcid":"https://orcid.org/0000-0002-2156-5516"},"institutions":[{"id":"https://openalex.org/I162290304","display_name":"Scuola Superiore Sant'Anna","ror":"https://ror.org/025602r80","country_code":"IT","type":"education","lineage":["https://openalex.org/I162290304"]},{"id":"https://openalex.org/I4210112163","display_name":"IT+Robotics (Italy)","ror":"https://ror.org/023d8gn94","country_code":"IT","type":"company","lineage":["https://openalex.org/I4210112163"]},{"id":"https://openalex.org/I4210116474","display_name":"Center for Micro-BioRobotics","ror":"https://ror.org/02nbgxg43","country_code":"IT","type":"facility","lineage":["https://openalex.org/I30771326","https://openalex.org/I4210116474"]},{"id":"https://openalex.org/I4210116723","display_name":"Robotics Research (United States)","ror":"https://ror.org/020w2fr77","country_code":"US","type":"company","lineage":["https://openalex.org/I4210116723"]},{"id":"https://openalex.org/I4210136571","display_name":"Medrobotics (United States)","ror":"https://ror.org/03z02zc05","country_code":"US","type":"company","lineage":["https://openalex.org/I4210136571"]}],"countries":["IT","US"],"is_corresponding":false,"raw_author_name":"Marta Gherardini","raw_affiliation_strings":["BioRobotics Institute and the Department of Excellence in Robotics and AI, Italy","BioRobotics Institute and the Department of Excellence in Robotics and AI, Scuola Superiore Sant'Anna, Pisa, Italy"],"raw_orcid":"https://orcid.org/0000-0002-2156-5516","affiliations":[{"raw_affiliation_string":"BioRobotics Institute and the Department of Excellence in Robotics and AI, Italy","institution_ids":["https://openalex.org/I4210116474","https://openalex.org/I4210112163","https://openalex.org/I4210116723","https://openalex.org/I4210136571"]},{"raw_affiliation_string":"BioRobotics Institute and the Department of Excellence in Robotics and AI, Scuola Superiore Sant'Anna, Pisa, Italy","institution_ids":["https://openalex.org/I162290304"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5103097503","display_name":"Christian Cipriani","orcid":"https://orcid.org/0000-0003-2108-0700"},"institutions":[{"id":"https://openalex.org/I162290304","display_name":"Scuola Superiore Sant'Anna","ror":"https://ror.org/025602r80","country_code":"IT","type":"education","lineage":["https://openalex.org/I162290304"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Christian Cipriani","raw_affiliation_strings":["BioRobotics Institute and the Department of Excellence in Robotics and AI, Scuola Superiore Sant&#x0027;Anna, Pisa, Italy"],"raw_orcid":"https://orcid.org/0000-0003-2108-0700","affiliations":[{"raw_affiliation_string":"BioRobotics Institute and the Department of Excellence in Robotics and AI, Scuola Superiore Sant&#x0027;Anna, Pisa, Italy","institution_ids":["https://openalex.org/I162290304"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.458,"has_fulltext":true,"cited_by_count":15,"citation_normalized_percentile":{"value":0.80471705,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":"71","issue":"3","first_page":"1068","last_page":"1075"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10784","display_name":"Muscle activation and electromyography studies","score":0.8831999897956848,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10784","display_name":"Muscle activation and electromyography studies","score":0.8831999897956848,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10338","display_name":"Advanced Sensor and Energy Harvesting Materials","score":0.01860000006854534,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10429","display_name":"EEG and Brain-Computer Interfaces","score":0.018400000408291817,"subfield":{"id":"https://openalex.org/subfields/2805","display_name":"Cognitive Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/modular-design","display_name":"Modular design","score":0.6078018546104431},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5300965905189514},{"id":"https://openalex.org/keywords/interface","display_name":"Interface (matter)","score":0.49649864435195923},{"id":"https://openalex.org/keywords/context","display_name":"Context (archaeology)","score":0.4588932991027832},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.45521706342697144},{"id":"https://openalex.org/keywords/magnet","display_name":"Magnet","score":0.42076346278190613},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.21912318468093872},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.21320706605911255},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.12727618217468262},{"id":"https://openalex.org/keywords/biology","display_name":"Biology","score":0.1257447600364685}],"concepts":[{"id":"https://openalex.org/C101468663","wikidata":"https://www.wikidata.org/wiki/Q1620158","display_name":"Modular design","level":2,"score":0.6078018546104431},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5300965905189514},{"id":"https://openalex.org/C113843644","wikidata":"https://www.wikidata.org/wiki/Q901882","display_name":"Interface (matter)","level":4,"score":0.49649864435195923},{"id":"https://openalex.org/C2779343474","wikidata":"https://www.wikidata.org/wiki/Q3109175","display_name":"Context (archaeology)","level":2,"score":0.4588932991027832},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.45521706342697144},{"id":"https://openalex.org/C16389437","wikidata":"https://www.wikidata.org/wiki/Q11421","display_name":"Magnet","level":2,"score":0.42076346278190613},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.21912318468093872},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.21320706605911255},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.12727618217468262},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.1257447600364685},{"id":"https://openalex.org/C129307140","wikidata":"https://www.wikidata.org/wiki/Q6795880","display_name":"Maximum bubble pressure method","level":3,"score":0.0},{"id":"https://openalex.org/C157915830","wikidata":"https://www.wikidata.org/wiki/Q2928001","display_name":"Bubble","level":2,"score":0.0},{"id":"https://openalex.org/C151730666","wikidata":"https://www.wikidata.org/wiki/Q7205","display_name":"Paleontology","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D000674","descriptor_name":"Amputees","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000674","descriptor_name":"Amputees","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000674","descriptor_name":"Amputees","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000674","descriptor_name":"Amputees","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000674","descriptor_name":"Amputees","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D001132","descriptor_name":"Arm","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001132","descriptor_name":"Arm","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001132","descriptor_name":"Arm","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001132","descriptor_name":"Arm","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001132","descriptor_name":"Arm","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001186","descriptor_name":"Artificial Limbs","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D001186","descriptor_name":"Artificial Limbs","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D001186","descriptor_name":"Artificial Limbs","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D001186","descriptor_name":"Artificial Limbs","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D001186","descriptor_name":"Artificial Limbs","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D004576","descriptor_name":"Electromyography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D004576","descriptor_name":"Electromyography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D004576","descriptor_name":"Electromyography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D004576","descriptor_name":"Electromyography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D004576","descriptor_name":"Electromyography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D006225","descriptor_name":"Hand","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006225","descriptor_name":"Hand","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006225","descriptor_name":"Hand","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006225","descriptor_name":"Hand","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006225","descriptor_name":"Hand","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011474","descriptor_name":"Prosthesis Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011474","descriptor_name":"Prosthesis Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011474","descriptor_name":"Prosthesis Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011474","descriptor_name":"Prosthesis Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011474","descriptor_name":"Prosthesis Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D018482","descriptor_name":"Muscle, Skeletal","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D018482","descriptor_name":"Muscle, Skeletal","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D018482","descriptor_name":"Muscle, Skeletal","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D018482","descriptor_name":"Muscle, Skeletal","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D018482","descriptor_name":"Muscle, Skeletal","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D059346","descriptor_name":"Magnets","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D059346","descriptor_name":"Magnets","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D059346","descriptor_name":"Magnets","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D059346","descriptor_name":"Magnets","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D059346","descriptor_name":"Magnets","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":3,"locations":[{"id":"doi:10.1109/tbme.2023.3325910","is_oa":true,"landing_page_url":"https://doi.org/10.1109/tbme.2023.3325910","pdf_url":"https://ieeexplore.ieee.org/ielx7/10/4359967/10287986.pdf","source":{"id":"https://openalex.org/S5240358","display_name":"IEEE Transactions on Biomedical Engineering","issn_l":"0018-9294","issn":["0018-9294","1558-2531"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Engineering","raw_type":"journal-article"},{"id":"pmid:37856259","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/37856259","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE transactions on bio-medical engineering","raw_type":null},{"id":"pmh:oai:www.iris.sssup.it:11382/572873","is_oa":true,"landing_page_url":"https://hdl.handle.net/11382/572873","pdf_url":null,"source":{"id":"https://openalex.org/S4377196376","display_name":"CINECA IRIS Institutional Research Information System (Sant'Anna School of Advanced Studies)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I162290304","host_organization_name":"Scuola Superiore Sant'Anna","host_organization_lineage":["https://openalex.org/I162290304"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":{"id":"doi:10.1109/tbme.2023.3325910","is_oa":true,"landing_page_url":"https://doi.org/10.1109/tbme.2023.3325910","pdf_url":"https://ieeexplore.ieee.org/ielx7/10/4359967/10287986.pdf","source":{"id":"https://openalex.org/S5240358","display_name":"IEEE Transactions on Biomedical Engineering","issn_l":"0018-9294","issn":["0018-9294","1558-2531"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Engineering","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.800000011920929,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4387789697.pdf","grobid_xml":"https://content.openalex.org/works/W4387789697.grobid-xml"},"referenced_works_count":42,"referenced_works":["https://openalex.org/W109542373","https://openalex.org/W1480428586","https://openalex.org/W1981650989","https://openalex.org/W1992176208","https://openalex.org/W2013681472","https://openalex.org/W2047651217","https://openalex.org/W2101843765","https://openalex.org/W2124333487","https://openalex.org/W2125585124","https://openalex.org/W2135648815","https://openalex.org/W2148268262","https://openalex.org/W2160412627","https://openalex.org/W2162891965","https://openalex.org/W2164178698","https://openalex.org/W2180884865","https://openalex.org/W2330280761","https://openalex.org/W2619944123","https://openalex.org/W2627151322","https://openalex.org/W2775075722","https://openalex.org/W2912654229","https://openalex.org/W2944033464","https://openalex.org/W2957934965","https://openalex.org/W2968064715","https://openalex.org/W3082479938","https://openalex.org/W3087462846","https://openalex.org/W3125043125","https://openalex.org/W3134457106","https://openalex.org/W3165882235","https://openalex.org/W3196354977","https://openalex.org/W3198167763","https://openalex.org/W4206051182","https://openalex.org/W4206899070","https://openalex.org/W4220795728","https://openalex.org/W4221075161","https://openalex.org/W4240034171","https://openalex.org/W4283696685","https://openalex.org/W4293764640","https://openalex.org/W4307372403","https://openalex.org/W4362603181","https://openalex.org/W4367319342","https://openalex.org/W4368359873","https://openalex.org/W6797731841"],"related_works":["https://openalex.org/W2381426581","https://openalex.org/W2024370140","https://openalex.org/W2159705349","https://openalex.org/W2378076731","https://openalex.org/W4286888643","https://openalex.org/W2105392727","https://openalex.org/W2081826635","https://openalex.org/W2125678830","https://openalex.org/W3210795196","https://openalex.org/W601048412"],"abstract_inverted_index":{"OBJECTIVE:":[0],"The":[1,128,150],"search":[2],"for":[3,8,142,181],"a":[4,64,73,77,101,107,145,178,185],"physiologically":[5],"appropriate":[6,50],"interface":[7,62],"the":[9,34,40,53,84,88,162,182,194,197,201],"control":[10,30],"of":[11,36,58,87,106,164,184,200,212],"dexterous":[12],"hand":[13],"prostheses":[14],"is":[15],"an":[16,26,92,207],"ongoing":[17],"challenge":[18],"in":[19,39,72,144,161],"bioengineering.":[20],"In":[21,91],"this":[22,61,96],"context,":[23],"we":[24,99],"proposed":[25],"interface,":[27,31,203],"named":[28],"myokinetic":[29,187,202],"based":[32],"on":[33],"localization":[35],"magnets":[37,156],"implanted":[38,213],"residual":[41],"limb":[42,75],"muscles,":[43],"to":[44,52,80,94,111,118,123,154],"monitor":[45],"their":[46],"contractions":[47],"and":[48,135,172],"send":[49],"commands":[51],"artificial":[54,208],"hand.":[55,189],"As":[56],"part":[57],"such":[59],"concept,":[60],"requires":[63],"transcutaneous":[65],"magnet":[66],"localizer":[67],"that":[68],"can":[69],"be":[70,81],"integrated":[71],"self-contained":[74,186],"prosthesis,":[76],"feature":[78],"yet":[79],"realized":[82],"within":[83],"current":[85],"state":[86],"art.":[89],"METHODS:":[90],"attempt":[93],"cover":[95],"gap,":[97],"here":[98],"present":[100],"modular":[102],"embedded":[103],"system":[104,129,151,179],"consisting":[105],"computation":[108,132],"unit":[109],"able":[110,153],"acquire":[112],"synchronized":[113],"samples":[114],"captured":[115],"by":[116,210],"up":[117],"eight":[119],"acquisition":[120],"units,":[121],"so":[122],"localize":[124,155],"multiple":[125],"magnets.":[126,214],"RESULTS:":[127],"exhibits":[130],"short":[131],"times":[133],"(<60ms)":[134],"power":[136],"consumption":[137],"(0.6-1.2W)":[138],"which":[139],"are":[140],"suitable":[141,180],"use":[143],"clinically":[146],"viable":[147],"prosthetic":[148,188],"arm.":[149],"proved":[152],"while":[157],"moving":[158],"at":[159],"speeds":[160],"range":[163],"physiological":[165],"movements":[166],"(<0.24m/s),":[167],"with":[168,204],"high":[169],"accuracy":[170],"(<1mm)":[171],"precision":[173],"(<0.5mm).":[174],"CONCLUSION:":[175],"We":[176],"demonstrated":[177],"implementation":[183,199],"SIGNIFICANCE:":[190],"These":[191],"results":[192],"pave":[193],"way":[195],"towards":[196],"clinical":[198],"amputees":[205],"controlling":[206],"arm":[209],"means":[211]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":8},{"year":2024,"cited_by_count":5},{"year":2023,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
