{"id":"https://openalex.org/W3008815204","doi":"https://doi.org/10.1109/tbme.2020.2976989","title":"PPG Sensor Contact Pressure Should Be Taken Into Account for Cuff-Less Blood Pressure Measurement","display_name":"PPG Sensor Contact Pressure Should Be Taken Into Account for Cuff-Less Blood Pressure Measurement","publication_year":2020,"publication_date":"2020-02-28","ids":{"openalex":"https://openalex.org/W3008815204","doi":"https://doi.org/10.1109/tbme.2020.2976989","mag":"3008815204","pmid":"https://pubmed.ncbi.nlm.nih.gov/32142414"},"language":"en","primary_location":{"id":"doi:10.1109/tbme.2020.2976989","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbme.2020.2976989","pdf_url":null,"source":{"id":"https://openalex.org/S5240358","display_name":"IEEE Transactions on Biomedical Engineering","issn_l":"0018-9294","issn":["0018-9294","1558-2531"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Engineering","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://www.ncbi.nlm.nih.gov/pmc/articles/8856571","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5021878181","display_name":"Anand Chandrasekhar","orcid":"https://orcid.org/0000-0001-9541-8191"},"institutions":[{"id":"https://openalex.org/I87216513","display_name":"Michigan State University","ror":"https://ror.org/05hs6h993","country_code":"US","type":"education","lineage":["https://openalex.org/I87216513"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Anand Chandrasekhar","raw_affiliation_strings":["Dept. of Electrical and Computer Engineering, Michigan State University, East Lansing, MI, USA"],"raw_orcid":"https://orcid.org/0000-0001-9541-8191","affiliations":[{"raw_affiliation_string":"Dept. of Electrical and Computer Engineering, Michigan State University, East Lansing, MI, USA","institution_ids":["https://openalex.org/I87216513"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5038145562","display_name":"Mohammad Yavarimanesh","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Mohammad Yavarimanesh","raw_affiliation_strings":["Department of Electrical and Computer EngineeringMichigan State University"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer EngineeringMichigan State University","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5068943422","display_name":"Keerthana Natarajan","orcid":"https://orcid.org/0000-0002-9311-8192"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Keerthana Natarajan","raw_affiliation_strings":["Department of Electrical and Computer EngineeringMichigan State University"],"raw_orcid":"https://orcid.org/0000-0002-9311-8192","affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer EngineeringMichigan State University","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5057276590","display_name":"Jin\u2010Oh Hahn","orcid":"https://orcid.org/0000-0001-5429-2836"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Jin-Oh Hahn","raw_affiliation_strings":["Department of Mechanical EngineeringUniversity of Maryland"],"raw_orcid":"https://orcid.org/0000-0001-5429-2836","affiliations":[{"raw_affiliation_string":"Department of Mechanical EngineeringUniversity of Maryland","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5076698656","display_name":"Ramakrishna Mukkamala","orcid":"https://orcid.org/0000-0001-8918-4050"},"institutions":[{"id":"https://openalex.org/I87216513","display_name":"Michigan State University","ror":"https://ror.org/05hs6h993","country_code":"US","type":"education","lineage":["https://openalex.org/I87216513"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Ramakrishna Mukkamala","raw_affiliation_strings":["Dept. of Electrical and Computer Engineering, Michigan State University, East Lansing, MI, USA"],"raw_orcid":"https://orcid.org/0000-0001-8918-4050","affiliations":[{"raw_affiliation_string":"Dept. of Electrical and Computer Engineering, Michigan State University, East Lansing, MI, USA","institution_ids":["https://openalex.org/I87216513"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5021878181"],"corresponding_institution_ids":["https://openalex.org/I87216513"],"apc_list":null,"apc_paid":null,"fwci":5.7463,"has_fulltext":false,"cited_by_count":105,"citation_normalized_percentile":{"value":0.97016346,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":97,"max":100},"biblio":{"volume":"67","issue":"11","first_page":"3134","last_page":"3140"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9878000020980835,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9878000020980835,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11700","display_name":"Hemodynamic Monitoring and Therapy","score":0.002099999925121665,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10745","display_name":"Heart Rate Variability and Autonomic Control","score":0.0010999999940395355,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/cuff","display_name":"Cuff","score":0.7395460605621338},{"id":"https://openalex.org/keywords/photoplethysmogram","display_name":"Photoplethysmogram","score":0.7102596759796143},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.6077418327331543},{"id":"https://openalex.org/keywords/pressure-measurement","display_name":"Pressure measurement","score":0.5672257542610168},{"id":"https://openalex.org/keywords/blood-pressure","display_name":"Blood pressure","score":0.5517938137054443},{"id":"https://openalex.org/keywords/waveform","display_name":"Waveform","score":0.5068548321723938},{"id":"https://openalex.org/keywords/pulse","display_name":"Pulse (music)","score":0.5026454925537109},{"id":"https://openalex.org/keywords/diastole","display_name":"Diastole","score":0.45741671323776245},{"id":"https://openalex.org/keywords/plethysmograph","display_name":"Plethysmograph","score":0.4311876893043518},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.42768967151641846},{"id":"https://openalex.org/keywords/cardiology","display_name":"Cardiology","score":0.3438106179237366},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.3377400040626526},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.31049323081970215},{"id":"https://openalex.org/keywords/internal-medicine","display_name":"Internal medicine","score":0.25894662737846375},{"id":"https://openalex.org/keywords/surgery","display_name":"Surgery","score":0.20994305610656738},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.20900151133537292},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.16464009881019592},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.13209819793701172},{"id":"https://openalex.org/keywords/statistics","display_name":"Statistics","score":0.09456202387809753},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.07723048329353333}],"concepts":[{"id":"https://openalex.org/C2780017030","wikidata":"https://www.wikidata.org/wiki/Q368366","display_name":"Cuff","level":2,"score":0.7395460605621338},{"id":"https://openalex.org/C116390426","wikidata":"https://www.wikidata.org/wiki/Q7187885","display_name":"Photoplethysmogram","level":3,"score":0.7102596759796143},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.6077418327331543},{"id":"https://openalex.org/C80264047","wikidata":"https://www.wikidata.org/wiki/Q7424019","display_name":"Pressure measurement","level":2,"score":0.5672257542610168},{"id":"https://openalex.org/C84393581","wikidata":"https://www.wikidata.org/wiki/Q82642","display_name":"Blood pressure","level":2,"score":0.5517938137054443},{"id":"https://openalex.org/C197424946","wikidata":"https://www.wikidata.org/wiki/Q1165717","display_name":"Waveform","level":3,"score":0.5068548321723938},{"id":"https://openalex.org/C2780167933","wikidata":"https://www.wikidata.org/wiki/Q1550652","display_name":"Pulse (music)","level":3,"score":0.5026454925537109},{"id":"https://openalex.org/C57900726","wikidata":"https://www.wikidata.org/wiki/Q492905","display_name":"Diastole","level":3,"score":0.45741671323776245},{"id":"https://openalex.org/C73362275","wikidata":"https://www.wikidata.org/wiki/Q181277","display_name":"Plethysmograph","level":2,"score":0.4311876893043518},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.42768967151641846},{"id":"https://openalex.org/C164705383","wikidata":"https://www.wikidata.org/wiki/Q10379","display_name":"Cardiology","level":1,"score":0.3438106179237366},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.3377400040626526},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.31049323081970215},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.25894662737846375},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.20994305610656738},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.20900151133537292},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.16464009881019592},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.13209819793701172},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.09456202387809753},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.07723048329353333},{"id":"https://openalex.org/C94915269","wikidata":"https://www.wikidata.org/wiki/Q1834857","display_name":"Detector","level":2,"score":0.0},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.0},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.0},{"id":"https://openalex.org/C554190296","wikidata":"https://www.wikidata.org/wiki/Q47528","display_name":"Radar","level":2,"score":0.0}],"mesh":[{"descriptor_ui":"D001794","descriptor_name":"Blood Pressure","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001794","descriptor_name":"Blood Pressure","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001794","descriptor_name":"Blood Pressure","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001795","descriptor_name":"Blood Pressure Determination","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D001795","descriptor_name":"Blood Pressure Determination","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D001795","descriptor_name":"Blood Pressure Determination","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D010991","descriptor_name":"Plethysmography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D010991","descriptor_name":"Plethysmography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D010991","descriptor_name":"Plethysmography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017156","descriptor_name":"Photoplethysmography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017156","descriptor_name":"Photoplethysmography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017156","descriptor_name":"Photoplethysmography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D063177","descriptor_name":"Pulse Wave Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D063177","descriptor_name":"Pulse Wave Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D063177","descriptor_name":"Pulse Wave Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true}],"locations_count":3,"locations":[{"id":"doi:10.1109/tbme.2020.2976989","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbme.2020.2976989","pdf_url":null,"source":{"id":"https://openalex.org/S5240358","display_name":"IEEE Transactions on Biomedical Engineering","issn_l":"0018-9294","issn":["0018-9294","1558-2531"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Engineering","raw_type":"journal-article"},{"id":"pmid:32142414","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/32142414","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE transactions on bio-medical engineering","raw_type":null},{"id":"pmh:oai:pubmedcentral.nih.gov:8856571","is_oa":true,"landing_page_url":"https://www.ncbi.nlm.nih.gov/pmc/articles/8856571","pdf_url":null,"source":{"id":"https://openalex.org/S2764455111","display_name":"PubMed Central","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Trans Biomed Eng","raw_type":"Text"}],"best_oa_location":{"id":"pmh:oai:pubmedcentral.nih.gov:8856571","is_oa":true,"landing_page_url":"https://www.ncbi.nlm.nih.gov/pmc/articles/8856571","pdf_url":null,"source":{"id":"https://openalex.org/S2764455111","display_name":"PubMed Central","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Trans Biomed Eng","raw_type":"Text"},"sustainable_development_goals":[{"score":0.7799999713897705,"id":"https://metadata.un.org/sdg/3","display_name":"Good health and well-being"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":26,"referenced_works":["https://openalex.org/W1977471369","https://openalex.org/W1981918735","https://openalex.org/W1987949413","https://openalex.org/W1998552922","https://openalex.org/W2041420156","https://openalex.org/W2053239568","https://openalex.org/W2059208589","https://openalex.org/W2071224021","https://openalex.org/W2083872334","https://openalex.org/W2105257471","https://openalex.org/W2143940749","https://openalex.org/W2148325642","https://openalex.org/W2157792753","https://openalex.org/W2162273778","https://openalex.org/W2292374408","https://openalex.org/W2294418644","https://openalex.org/W2323988838","https://openalex.org/W2399174931","https://openalex.org/W2431637923","https://openalex.org/W2519778630","https://openalex.org/W2758839352","https://openalex.org/W2790680409","https://openalex.org/W2889312301","https://openalex.org/W2916533817","https://openalex.org/W4230437288","https://openalex.org/W6815317134"],"related_works":["https://openalex.org/W2732360296","https://openalex.org/W1994871954","https://openalex.org/W2414028099","https://openalex.org/W2414250197","https://openalex.org/W2079556393","https://openalex.org/W1790632686","https://openalex.org/W2985296909","https://openalex.org/W2399968241","https://openalex.org/W2888100659","https://openalex.org/W4289516467"],"abstract_inverted_index":{"OBJECTIVE:":[0],"Photo-plethysmography":[1],"(PPG)":[2],"sensors":[3,50],"are":[4],"often":[5],"used":[6],"to":[7,41,61,137,157,191],"detect":[8,222],"pulse":[9,73],"transit":[10],"time":[11,64,75],"(PTT)":[12],"for":[13,171,186,202,237],"potential":[14],"cuff-less":[15,203],"blood":[16],"pressure":[17,26],"(BP)":[18],"measurement.":[19],"It":[20],"is":[21,51,189],"known":[22],"that":[23,45,212,221],"the":[24,29,34,43,63,84,101,117,124,146,154,182,226,234],"contact":[25],"(CP)":[27],"of":[28,81,115,120],"PPG":[30,35,49,70,85,125,155,194],"sensor":[31,86,195],"markedly":[32],"alters":[33],"waveform":[36],"amplitude.":[37],"The":[38,148],"objective":[39],"was":[40,59,103,159],"test":[42],"hypothesis":[44],"PTT":[46,223],"detected":[47,122,152],"via":[48,206],"likewise":[52],"impacted":[53],"by":[54],"CP.":[55],"METHODS:":[56],"A":[57,167],"device":[58],"built":[60],"measure":[62],"delay":[65],"between":[66],"ECG":[67],"and":[68,83,94,127,131,139,175],"finger":[69,95,164,172],"waveforms":[71],"(i.e.,":[72],"arrival":[74],"(PAT)":[76],"-":[77],"a":[78,112,230],"popular":[79],"surrogate":[80],"PTT)":[82],"CP":[87,90,102,158,196,227,231],"at":[88,123,153],"different":[89],"levels.":[91],"These":[92],"measurements":[93],"cuff":[96],"BP":[97,142,187,204,216],"were":[98,129],"recorded":[99],"while":[100],"slowly":[104],"varied":[105],"in":[106,233],"17":[107],"healthy":[108],"subjects.":[109],"RESULTS:":[110],"Over":[111],"physiologic":[113],"range":[114],"CP,":[116],"maximum":[118],"deviations":[119],"PAT":[121,151],"foot":[126,156],"peak":[128],"22\u00b12":[130],"40\u00b17":[132],"ms":[133],"(p<0.05),":[134],"which":[135],"translate":[136],"\u223c11":[138],"\u223c20":[140],"mmHg":[141],"error":[143,185],"based":[144],"on":[145],"literature.":[147],"curve":[149],"relating":[150],"U-shaped":[160],"with":[161],"minimum":[162],"near":[163],"diastolic":[165],"BP.":[166,239],"conceptual":[168],"model":[169],"accounting":[170],"artery":[173],"viscoelasticity":[174],"nonlinearity":[176],"explained":[177],"this":[178],"curve.":[179],"CONCLUSION:":[180],"Since":[181],"regulatory":[183],"bias":[184],"measurement":[188,205,217,232],"limited":[190],"5":[192],"mmHg,":[193],"should":[197,224],"be":[198],"taken":[199],"into":[200],"account":[201],"PTT.":[207],"SIGNIFICANCE:":[208],"This":[209],"study":[210],"suggests":[211],"widely":[213],"pursued":[214],"PPG-based":[215],"devices":[218],"including":[219],"those":[220],"maintain":[225],"or":[228],"include":[229],"calibration":[235],"equation":[236],"deriving":[238]},"counts_by_year":[{"year":2026,"cited_by_count":4},{"year":2025,"cited_by_count":16},{"year":2024,"cited_by_count":19},{"year":2023,"cited_by_count":24},{"year":2022,"cited_by_count":21},{"year":2021,"cited_by_count":17},{"year":2020,"cited_by_count":4}],"updated_date":"2026-04-29T09:16:38.111599","created_date":"2025-10-10T00:00:00"}
