{"id":"https://openalex.org/W2785094812","doi":"https://doi.org/10.1109/tbme.2018.2798812","title":"On the Feasibility of Automated Mechanical Ventilation Control Through EIT","display_name":"On the Feasibility of Automated Mechanical Ventilation Control Through EIT","publication_year":2018,"publication_date":"2018-02-23","ids":{"openalex":"https://openalex.org/W2785094812","doi":"https://doi.org/10.1109/tbme.2018.2798812","mag":"2785094812","pmid":"https://pubmed.ncbi.nlm.nih.gov/29993487"},"language":"en","primary_location":{"id":"doi:10.1109/tbme.2018.2798812","is_oa":true,"landing_page_url":"https://doi.org/10.1109/tbme.2018.2798812","pdf_url":"https://ieeexplore.ieee.org/ielx7/10/8496928/08301569.pdf","source":{"id":"https://openalex.org/S5240358","display_name":"IEEE Transactions on Biomedical Engineering","issn_l":"0018-9294","issn":["0018-9294","1558-2531"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Engineering","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":true,"oa_status":"hybrid","oa_url":"https://ieeexplore.ieee.org/ielx7/10/8496928/08301569.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5015372912","display_name":"Henry F. J. Tregidgo","orcid":"https://orcid.org/0000-0002-3509-8154"},"institutions":[{"id":"https://openalex.org/I28407311","display_name":"University of Manchester","ror":"https://ror.org/027m9bs27","country_code":"GB","type":"education","lineage":["https://openalex.org/I28407311"]}],"countries":["GB"],"is_corresponding":true,"raw_author_name":"Henry F. J. Tregidgo","raw_affiliation_strings":["School of Mathematics, University of Manchester, Manchester, U.K"],"raw_orcid":"https://orcid.org/0000-0002-3509-8154","affiliations":[{"raw_affiliation_string":"School of Mathematics, University of Manchester, Manchester, U.K","institution_ids":["https://openalex.org/I28407311"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5102927075","display_name":"Michael Crabb","orcid":"https://orcid.org/0000-0002-7919-9731"},"institutions":[{"id":"https://openalex.org/I28407311","display_name":"University of Manchester","ror":"https://ror.org/027m9bs27","country_code":"GB","type":"education","lineage":["https://openalex.org/I28407311"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Michael G. Crabb","raw_affiliation_strings":["School of Mathematics, University of Manchester, Manchester"],"raw_orcid":"https://orcid.org/0000-0002-7919-9731","affiliations":[{"raw_affiliation_string":"School of Mathematics, University of Manchester, Manchester","institution_ids":["https://openalex.org/I28407311"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5081452567","display_name":"Andrew L. Hazel","orcid":"https://orcid.org/0000-0003-1130-0554"},"institutions":[{"id":"https://openalex.org/I28407311","display_name":"University of Manchester","ror":"https://ror.org/027m9bs27","country_code":"GB","type":"education","lineage":["https://openalex.org/I28407311"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Andrew L. Hazel","raw_affiliation_strings":["School of Mathematics, University of Manchester, Manchester"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Mathematics, University of Manchester, Manchester","institution_ids":["https://openalex.org/I28407311"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5058599589","display_name":"William Lionheart","orcid":"https://orcid.org/0000-0003-0971-4678"},"institutions":[{"id":"https://openalex.org/I28407311","display_name":"University of Manchester","ror":"https://ror.org/027m9bs27","country_code":"GB","type":"education","lineage":["https://openalex.org/I28407311"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"William R. B. Lionheart","raw_affiliation_strings":["School of Mathematics, University of Manchester, Manchester"],"raw_orcid":"https://orcid.org/0000-0003-0971-4678","affiliations":[{"raw_affiliation_string":"School of Mathematics, University of Manchester, Manchester","institution_ids":["https://openalex.org/I28407311"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5015372912"],"corresponding_institution_ids":["https://openalex.org/I28407311"],"apc_list":null,"apc_paid":null,"fwci":0.7337,"has_fulltext":true,"cited_by_count":10,"citation_normalized_percentile":{"value":0.7257094,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":99},"biblio":{"volume":"65","issue":"11","first_page":"2459","last_page":"2470"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10322","display_name":"Respiratory Support and Mechanisms","score":0.5867000222206116,"subfield":{"id":"https://openalex.org/subfields/2740","display_name":"Pulmonary and Respiratory Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T10322","display_name":"Respiratory Support and Mechanisms","score":0.5867000222206116,"subfield":{"id":"https://openalex.org/subfields/2740","display_name":"Pulmonary and Respiratory Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11778","display_name":"Electrical and Bioimpedance Tomography","score":0.2939999997615814,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11651","display_name":"Inhalation and Respiratory Drug Delivery","score":0.009200000204145908,"subfield":{"id":"https://openalex.org/subfields/2740","display_name":"Pulmonary and Respiratory Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.46039196848869324},{"id":"https://openalex.org/keywords/automatic-control","display_name":"Automatic control","score":0.4285799562931061},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.362987756729126},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.34036141633987427},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.29120761156082153}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.46039196848869324},{"id":"https://openalex.org/C167123822","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automatic control","level":2,"score":0.4285799562931061},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.362987756729126},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.34036141633987427},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.29120761156082153}],"mesh":[{"descriptor_ui":"D000328","descriptor_name":"Adult","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000328","descriptor_name":"Adult","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000328","descriptor_name":"Adult","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008168","descriptor_name":"Lung","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D008168","descriptor_name":"Lung","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D008168","descriptor_name":"Lung","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D008297","descriptor_name":"Male","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008297","descriptor_name":"Male","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008297","descriptor_name":"Male","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008954","descriptor_name":"Models, Biological","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D008954","descriptor_name":"Models, Biological","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D008954","descriptor_name":"Models, Biological","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D012121","descriptor_name":"Respiration, Artificial","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D012121","descriptor_name":"Respiration, Artificial","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D012121","descriptor_name":"Respiration, Artificial","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D012123","descriptor_name":"Pulmonary Ventilation","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D012123","descriptor_name":"Pulmonary Ventilation","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D012123","descriptor_name":"Pulmonary Ventilation","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D014054","descriptor_name":"Tomography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D014054","descriptor_name":"Tomography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D014054","descriptor_name":"Tomography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D017097","descriptor_name":"Electric Impedance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D017097","descriptor_name":"Electric Impedance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D017097","descriptor_name":"Electric Impedance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true}],"locations_count":5,"locations":[{"id":"doi:10.1109/tbme.2018.2798812","is_oa":true,"landing_page_url":"https://doi.org/10.1109/tbme.2018.2798812","pdf_url":"https://ieeexplore.ieee.org/ielx7/10/8496928/08301569.pdf","source":{"id":"https://openalex.org/S5240358","display_name":"IEEE Transactions on Biomedical Engineering","issn_l":"0018-9294","issn":["0018-9294","1558-2531"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Engineering","raw_type":"journal-article"},{"id":"pmid:29993487","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/29993487","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE transactions on bio-medical engineering","raw_type":null},{"id":"pmh:oai:pure.atira.dk:openaire/ec2f6b36-8285-41db-a2f8-559f06fc800f","is_oa":true,"landing_page_url":"https://research.manchester.ac.uk/en/publications/ec2f6b36-8285-41db-a2f8-559f06fc800f","pdf_url":null,"source":{"id":"https://openalex.org/S4306400662","display_name":"Research Explorer (The University of Manchester)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I28407311","host_organization_name":"University of Manchester","host_organization_lineage":["https://openalex.org/I28407311"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Tregidgo, H, Crabb, M, Hazel, A & Lionheart, W 2018, 'On the feasibility of automated mechanical ventilation control through EIT', IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/TBME.2018.2798812","raw_type":"info:eu-repo/semantics/publishedVersion"},{"id":"pmh:oai:eprints.ucl.ac.uk.OAI2:10056679","is_oa":false,"landing_page_url":"https://discovery.ucl.ac.uk/id/eprint/10056679/","pdf_url":null,"source":{"id":"https://openalex.org/S4306400024","display_name":"UCL Discovery (University College London)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I45129253","host_organization_name":"University College London","host_organization_lineage":["https://openalex.org/I45129253"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"   IEEE Transactions on Biomedical Engineering , 65  (11)   2459 -2470.   (2018)      ","raw_type":"Article"},{"id":"pmh:oai:pure.atira.dk:publications/ec2f6b36-8285-41db-a2f8-559f06fc800f","is_oa":true,"landing_page_url":"https://www.research.manchester.ac.uk/portal/en/publications/on-the-feasibility-of-automated-mechanical-ventilation-control-through-eit(ec2f6b36-8285-41db-a2f8-559f06fc800f).html","pdf_url":null,"source":{"id":"https://openalex.org/S4306400662","display_name":"Research Explorer (The University of Manchester)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I28407311","host_organization_name":"University of Manchester","host_organization_lineage":["https://openalex.org/I28407311"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Tregidgo, H, Crabb, M, Hazel, A & Lionheart, W 2018, 'On the feasibility of automated mechanical ventilation control through EIT', IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/TBME.2018.2798812","raw_type":"info:eu-repo/semantics/publishedVersion"}],"best_oa_location":{"id":"doi:10.1109/tbme.2018.2798812","is_oa":true,"landing_page_url":"https://doi.org/10.1109/tbme.2018.2798812","pdf_url":"https://ieeexplore.ieee.org/ielx7/10/8496928/08301569.pdf","source":{"id":"https://openalex.org/S5240358","display_name":"IEEE Transactions on Biomedical Engineering","issn_l":"0018-9294","issn":["0018-9294","1558-2531"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Engineering","raw_type":"journal-article"},"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G2475154968","display_name":"Robust Repeatable Respiratory Monitoring with EIT","funder_award_id":"EP/L019108/1","funder_id":"https://openalex.org/F4320334627","funder_display_name":"Engineering and Physical Sciences Research Council"},{"id":"https://openalex.org/G3678418704","display_name":null,"funder_award_id":"EP/L019108/1","funder_id":"https://openalex.org/F4320334627","funder_display_name":"Engineering and Physical Sciences Research Council"}],"funders":[{"id":"https://openalex.org/F4320334627","display_name":"Engineering and Physical Sciences Research Council","ror":"https://ror.org/0439y7842"}],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2785094812.pdf","grobid_xml":"https://content.openalex.org/works/W2785094812.grobid-xml"},"referenced_works_count":61,"referenced_works":["https://openalex.org/W34336829","https://openalex.org/W619505969","https://openalex.org/W1499788862","https://openalex.org/W1502789621","https://openalex.org/W1750710754","https://openalex.org/W1777984739","https://openalex.org/W1803784511","https://openalex.org/W1840714420","https://openalex.org/W1868307336","https://openalex.org/W1880776999","https://openalex.org/W1944977254","https://openalex.org/W1964846255","https://openalex.org/W1968027319","https://openalex.org/W1970169011","https://openalex.org/W1978445072","https://openalex.org/W1990028119","https://openalex.org/W1991744090","https://openalex.org/W1994368767","https://openalex.org/W1998762105","https://openalex.org/W2001435563","https://openalex.org/W2008229822","https://openalex.org/W2015202371","https://openalex.org/W2024506048","https://openalex.org/W2027812057","https://openalex.org/W2037118588","https://openalex.org/W2037700964","https://openalex.org/W2040108689","https://openalex.org/W2041556066","https://openalex.org/W2046768434","https://openalex.org/W2052625285","https://openalex.org/W2077485693","https://openalex.org/W2078142761","https://openalex.org/W2082201463","https://openalex.org/W2087637359","https://openalex.org/W2088429582","https://openalex.org/W2093495347","https://openalex.org/W2113752525","https://openalex.org/W2114449024","https://openalex.org/W2115370751","https://openalex.org/W2118656639","https://openalex.org/W2125766343","https://openalex.org/W2127519209","https://openalex.org/W2131900135","https://openalex.org/W2139720540","https://openalex.org/W2142484354","https://openalex.org/W2143169929","https://openalex.org/W2162001089","https://openalex.org/W2163162343","https://openalex.org/W2167431840","https://openalex.org/W2167743972","https://openalex.org/W2170563839","https://openalex.org/W2252935822","https://openalex.org/W2284834937","https://openalex.org/W2286228001","https://openalex.org/W2329807542","https://openalex.org/W2791455276","https://openalex.org/W3100457172","https://openalex.org/W4241391200","https://openalex.org/W6638305679","https://openalex.org/W6638927443","https://openalex.org/W6749187176"],"related_works":["https://openalex.org/W4391375266","https://openalex.org/W2899084033","https://openalex.org/W2748952813","https://openalex.org/W2390279801","https://openalex.org/W4391913857","https://openalex.org/W2358668433","https://openalex.org/W4396701345","https://openalex.org/W2376932109","https://openalex.org/W2001405890","https://openalex.org/W4396696052"],"abstract_inverted_index":{"OBJECTIVE:":[0],"This":[1],"paper":[2],"aims":[3],"to":[4,21,41,51,71,82,97,105,117,138,155,194,223,239],"demonstrate":[5,98],"the":[6,66,90,179,233],"feasibility":[7],"of":[8,16,36,43,56,89,169,181,212,219,235],"coupling":[9],"electrical":[10],"impedance":[11],"tomography":[12],"(EIT)":[13],"with":[14,120,178],"models":[15],"lung":[17,37,174,226,230],"function":[18,38],"in":[19,124,160,189],"order":[20],"recover":[22,72,83],"parameters":[23,101,134,175,184,231],"and":[24,48,63,75,86,129,163,173,217],"inform":[25],"mechanical":[26,202],"ventilation":[27,78,171,203],"control.":[28,111],"METHODS:":[29],"A":[30],"compartmental":[31],"ordinary":[32],"differential":[33],"equation":[34],"model":[35,190],"is":[39,95,153,176,204],"coupled":[40],"simulations":[42],"EIT,":[44],"assuming":[45],"accurate":[46],"modeling":[47],"movement":[49],"tracking,":[50],"generate":[52,106],"time":[53],"series":[54],"values":[55,60,147],"bulk":[57],"conductivity.":[58],"These":[59,77,183],"are":[61,80,115,135,143],"differentiated":[62],"normalized":[64],"against":[65],"total":[67],"air":[68,125],"volume":[69,130],"flux":[70],"regional":[73,84,170,229],"volumes":[74],"flows.":[76],"distributions":[79,114,172],"used":[81,96,104,188],"resistance":[85,146],"elastance":[87],"properties":[88],"lung.":[91],"Linear":[92],"control":[93,151,192],"theory":[94],"how":[99],"these":[100],"may":[102,185],"be":[103,118,139,187],"a":[107,205],"patient-specific":[108,196,236],"pressure":[109,213,220],"mode":[110],"RESULTS:":[112],"Ventilation":[113],"shown":[116,137,154],"recoverable,":[119,140],"Euclidean":[121],"norm":[122],"errors":[123,142],"flow":[126],"below":[127,131],"9%":[128],"3%.":[132],"The":[133,150,167],"also":[136],"although":[141],"higher":[144],"for":[145],"than":[148],"elastance.":[149],"constructed":[152],"have":[156],"minimal":[157,164],"seminorm":[158],"resulting":[159],"bounded":[161],"magnitudes":[162,216],"gradients.":[165],"CONCLUSION:":[166],"recovery":[168],"feasible":[177],"use":[180],"EIT.":[182],"then":[186],"based":[191],"schemes":[193],"provide":[195],"care.":[197],"SIGNIFICANCE:":[198],"For":[199],"pulmonary-intensive-care":[200],"patients":[201],"life":[206],"saving":[207],"intervention,":[208],"requiring":[209],"careful":[210],"calibration":[211],"settings.":[214],"Both":[215],"gradients":[218],"can":[221],"contribute":[222],"ventilator":[224,237],"induced":[225],"injury.":[227,241],"Retrieving":[228],"allows":[232],"design":[234],"controls":[238],"reduce":[240]},"counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2021,"cited_by_count":4}],"updated_date":"2026-04-29T09:16:38.111599","created_date":"2025-10-10T00:00:00"}
