{"id":"https://openalex.org/W2588679294","doi":"https://doi.org/10.1109/tbme.2017.2668612","title":"A Review of In-Body Biotelemetry Devices: Implantables, Ingestibles, and Injectables","display_name":"A Review of In-Body Biotelemetry Devices: Implantables, Ingestibles, and Injectables","publication_year":2017,"publication_date":"2017-02-14","ids":{"openalex":"https://openalex.org/W2588679294","doi":"https://doi.org/10.1109/tbme.2017.2668612","mag":"2588679294","pmid":"https://pubmed.ncbi.nlm.nih.gov/28212074"},"language":"en","primary_location":{"id":"doi:10.1109/tbme.2017.2668612","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbme.2017.2668612","pdf_url":null,"source":{"id":"https://openalex.org/S5240358","display_name":"IEEE Transactions on Biomedical Engineering","issn_l":"0018-9294","issn":["0018-9294","1558-2531"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Engineering","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5090831914","display_name":"Asimina Kiourti","orcid":"https://orcid.org/0000-0002-7111-9442"},"institutions":[{"id":"https://openalex.org/I52357470","display_name":"The Ohio State University","ror":"https://ror.org/00rs6vg23","country_code":"US","type":"education","lineage":["https://openalex.org/I52357470"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Asimina Kiourti","raw_affiliation_strings":["ElectroScience Laboratory, Department of Electrical and Computer Engineering, The Ohio State University, Columbus, OH, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"ElectroScience Laboratory, Department of Electrical and Computer Engineering, The Ohio State University, Columbus, OH, USA","institution_ids":["https://openalex.org/I52357470"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5082313849","display_name":"Konstantina S. Nikita","orcid":"https://orcid.org/0000-0001-8255-4354"},"institutions":[{"id":"https://openalex.org/I174458059","display_name":"National Technical University of Athens","ror":"https://ror.org/03cx6bg69","country_code":"GR","type":"education","lineage":["https://openalex.org/I174458059"]}],"countries":["GR"],"is_corresponding":false,"raw_author_name":"Konstantina S. Nikita","raw_affiliation_strings":["School of Electrical and Computer Engineering, National Technical University of Athens"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Electrical and Computer Engineering, National Technical University of Athens","institution_ids":["https://openalex.org/I174458059"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":9.0465,"has_fulltext":false,"cited_by_count":268,"citation_normalized_percentile":{"value":0.98766645,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":98,"max":100},"biblio":{"volume":"64","issue":"7","first_page":"1422","last_page":"1430"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11932","display_name":"Wireless Body Area Networks","score":0.9089999794960022,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11932","display_name":"Wireless Body Area Networks","score":0.9089999794960022,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11249","display_name":"Wireless Power Transfer Systems","score":0.04450000077486038,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10598","display_name":"Cardiac pacing and defibrillation studies","score":0.008799999952316284,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/biotelemetry","display_name":"Biotelemetry","score":0.9870131611824036},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.486970990896225},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3772162199020386},{"id":"https://openalex.org/keywords/telemetry","display_name":"Telemetry","score":0.3005787432193756},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.16463524103164673}],"concepts":[{"id":"https://openalex.org/C192278026","wikidata":"https://www.wikidata.org/wiki/Q4915350","display_name":"Biotelemetry","level":3,"score":0.9870131611824036},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.486970990896225},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3772162199020386},{"id":"https://openalex.org/C183121708","wikidata":"https://www.wikidata.org/wiki/Q209867","display_name":"Telemetry","level":2,"score":0.3005787432193756},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.16463524103164673}],"mesh":[{"descriptor_ui":"D004435","descriptor_name":"Eating","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004435","descriptor_name":"Eating","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004435","descriptor_name":"Eating","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007267","descriptor_name":"Injections","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007267","descriptor_name":"Injections","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007267","descriptor_name":"Injections","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013673","descriptor_name":"Technology Assessment, Biomedical","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013673","descriptor_name":"Technology Assessment, Biomedical","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013673","descriptor_name":"Technology Assessment, Biomedical","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013686","descriptor_name":"Telemetry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D013686","descriptor_name":"Telemetry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D013686","descriptor_name":"Telemetry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D013686","descriptor_name":"Telemetry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D013686","descriptor_name":"Telemetry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D013686","descriptor_name":"Telemetry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D018670","descriptor_name":"Monitoring, Ambulatory","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D018670","descriptor_name":"Monitoring, Ambulatory","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D018670","descriptor_name":"Monitoring, Ambulatory","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D018670","descriptor_name":"Monitoring, Ambulatory","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D018670","descriptor_name":"Monitoring, Ambulatory","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D018670","descriptor_name":"Monitoring, Ambulatory","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D019736","descriptor_name":"Prostheses and Implants","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D019736","descriptor_name":"Prostheses and Implants","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D019736","descriptor_name":"Prostheses and Implants","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D019919","descriptor_name":"Prosthesis Implantation","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D019919","descriptor_name":"Prosthesis Implantation","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D019919","descriptor_name":"Prosthesis Implantation","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D059015","descriptor_name":"Wireless Technology","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D059015","descriptor_name":"Wireless Technology","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D059015","descriptor_name":"Wireless Technology","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false}],"locations_count":2,"locations":[{"id":"doi:10.1109/tbme.2017.2668612","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbme.2017.2668612","pdf_url":null,"source":{"id":"https://openalex.org/S5240358","display_name":"IEEE Transactions on Biomedical Engineering","issn_l":"0018-9294","issn":["0018-9294","1558-2531"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Engineering","raw_type":"journal-article"},{"id":"pmid:28212074","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/28212074","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE transactions on bio-medical engineering","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Good health and well-being","id":"https://metadata.un.org/sdg/3","score":0.4099999964237213}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":93,"referenced_works":["https://openalex.org/W1504641908","https://openalex.org/W1559614777","https://openalex.org/W1927444193","https://openalex.org/W1964943109","https://openalex.org/W1966417316","https://openalex.org/W1968789666","https://openalex.org/W1970635841","https://openalex.org/W1983537203","https://openalex.org/W1994707529","https://openalex.org/W1997321659","https://openalex.org/W2002241646","https://openalex.org/W2002273040","https://openalex.org/W2003945971","https://openalex.org/W2004411875","https://openalex.org/W2004771128","https://openalex.org/W2006821720","https://openalex.org/W2009360164","https://openalex.org/W2014529312","https://openalex.org/W2017762750","https://openalex.org/W2019643737","https://openalex.org/W2021733473","https://openalex.org/W2022478431","https://openalex.org/W2025390763","https://openalex.org/W2025722801","https://openalex.org/W2028472746","https://openalex.org/W2030706847","https://openalex.org/W2033305448","https://openalex.org/W2033787590","https://openalex.org/W2035932410","https://openalex.org/W2035979929","https://openalex.org/W2037315080","https://openalex.org/W2037884469","https://openalex.org/W2043136009","https://openalex.org/W2046114048","https://openalex.org/W2046916004","https://openalex.org/W2048375142","https://openalex.org/W2049260679","https://openalex.org/W2051207264","https://openalex.org/W2059042914","https://openalex.org/W2059183070","https://openalex.org/W2062131241","https://openalex.org/W2065142704","https://openalex.org/W2066811038","https://openalex.org/W2072076450","https://openalex.org/W2073755410","https://openalex.org/W2076890843","https://openalex.org/W2082000194","https://openalex.org/W2082222718","https://openalex.org/W2092275513","https://openalex.org/W2096007788","https://openalex.org/W2099353039","https://openalex.org/W2111980142","https://openalex.org/W2120101295","https://openalex.org/W2120182174","https://openalex.org/W2120872564","https://openalex.org/W2121703106","https://openalex.org/W2122360047","https://openalex.org/W2125628414","https://openalex.org/W2126408721","https://openalex.org/W2129690531","https://openalex.org/W2131264294","https://openalex.org/W2134834208","https://openalex.org/W2138551900","https://openalex.org/W2140781853","https://openalex.org/W2141392072","https://openalex.org/W2143404320","https://openalex.org/W2143561486","https://openalex.org/W2144682272","https://openalex.org/W2147256848","https://openalex.org/W2147913932","https://openalex.org/W2148357420","https://openalex.org/W2150078773","https://openalex.org/W2152069319","https://openalex.org/W2152119085","https://openalex.org/W2153438426","https://openalex.org/W2155723826","https://openalex.org/W2156749085","https://openalex.org/W2156848160","https://openalex.org/W2158934976","https://openalex.org/W2165366024","https://openalex.org/W2178696728","https://openalex.org/W2207677685","https://openalex.org/W2210060061","https://openalex.org/W2316104835","https://openalex.org/W2319172388","https://openalex.org/W2319574572","https://openalex.org/W2413204798","https://openalex.org/W2491396199","https://openalex.org/W3163852977","https://openalex.org/W4240629939","https://openalex.org/W4243391510","https://openalex.org/W6649666244","https://openalex.org/W6678309376"],"related_works":["https://openalex.org/W4239362949","https://openalex.org/W2187945040","https://openalex.org/W1520573235","https://openalex.org/W291327229","https://openalex.org/W4298869364","https://openalex.org/W2262552375","https://openalex.org/W2026985513","https://openalex.org/W2409935591","https://openalex.org/W1889770305","https://openalex.org/W2891435724"],"abstract_inverted_index":{"OBJECTIVE:":[0],"We":[1],"present":[2],"a":[3,182,200,206],"review":[4,29],"of":[5,37,92,102,184,191],"wireless":[6],"medical":[7,39,119,145],"devices":[8,43,53,63,86,112,138,162,177],"that":[9,44,54,64,124],"are":[10,45,55,65,87,95,113,139,163,178],"placed":[11],"inside":[12,47],"the":[13,48,68,83,172,188],"human":[14,49,69],"body":[15,50,70],"to":[16,82,153,159,180,198,205],"realize":[17],"many":[18],"and":[19,61,78,108,122,150,167],"different":[20],"sensing":[21],"and/or":[22,130],"stimulating":[23],"functionalities.":[24],"METHODS:":[25],"A":[26,90],"critical":[27],"literature":[28],"analysis":[30],"is":[31],"conducted":[32],"focusing":[33],"on":[34,132],"three":[35],"types":[36],"in-body":[38,85,98,111,161,176],"devices,":[40,99],"i.e.,":[41],"1)":[42],"implanted":[46],"(implantables),":[51],"2)":[52],"ingested":[56],"like":[57],"regular":[58],"pills":[59],"(ingestibles),":[60],"3)":[62],"injected":[66],"into":[67],"via":[71],"needles":[72],"(injectables).":[73],"Design":[74],"considerations,":[75],"current":[76],"status,":[77],"future":[79],"directions":[80],"related":[81],"aforementioned":[84],"discussed.":[88],"RESULTS:":[89],"number":[91],"design":[93,128],"challenges":[94,129],"associated":[96],"with":[97],"including":[100],"selection":[101],"operation":[103],"frequency,":[104],"antenna":[105],"design,":[106],"powering,":[107],"biocompatibility.":[109],"Nevertheless,":[110],"opening":[114],"up":[115],"new":[116,166],"opportunities":[117,170],"for":[118,143],"prevention,":[120],"prognosis,":[121],"treatment":[123],"quickly":[125],"outweigh":[126],"any":[127],"concerns":[131],"their":[133],"invasive":[134],"nature.":[135],"CONCLUSION:":[136],"In-body":[137],"already":[140],"in":[141,171],"use":[142],"several":[144,165],"applications,":[146],"ranging":[147],"from":[148,187,202],"pacemakers":[149],"capsule":[151],"endoscopes":[152],"injectable":[154],"microstimulators.":[155],"As":[156],"technology":[157],"continues":[158],"evolve,":[160],"promising":[164],"hitherto":[168],"unexplored":[169],"healthcare.":[173],"SIGNIFICANCE:":[174],"Unobtrusive":[175],"envisioned":[179],"collect":[181],"multitude":[183],"physiological":[185],"data":[186],"early":[189],"years":[190],"each":[192],"individual.":[193],"This":[194],"big-data":[195],"approach":[196],"aims":[197],"enable":[199],"shift":[201],"symptom-based":[203],"medicine":[204],"proactive":[207],"healthcare":[208],"model.":[209]},"counts_by_year":[{"year":2026,"cited_by_count":6},{"year":2025,"cited_by_count":51},{"year":2024,"cited_by_count":34},{"year":2023,"cited_by_count":33},{"year":2022,"cited_by_count":31},{"year":2021,"cited_by_count":30},{"year":2020,"cited_by_count":31},{"year":2019,"cited_by_count":25},{"year":2018,"cited_by_count":21},{"year":2017,"cited_by_count":6}],"updated_date":"2026-07-15T18:14:33.161393","created_date":"2025-10-10T00:00:00"}
