{"id":"https://openalex.org/W1980474073","doi":"https://doi.org/10.1109/tbme.2014.2364139","title":"Toward an Anemia Early Detection Device Based on 50-\u03bcL Whole Blood Sample","display_name":"Toward an Anemia Early Detection Device Based on 50-\u03bcL Whole Blood Sample","publication_year":2014,"publication_date":"2014-10-20","ids":{"openalex":"https://openalex.org/W1980474073","doi":"https://doi.org/10.1109/tbme.2014.2364139","mag":"1980474073","pmid":"https://pubmed.ncbi.nlm.nih.gov/25347870"},"language":"en","primary_location":{"id":"doi:10.1109/tbme.2014.2364139","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbme.2014.2364139","pdf_url":null,"source":{"id":"https://openalex.org/S5240358","display_name":"IEEE Transactions on Biomedical Engineering","issn_l":"0018-9294","issn":["0018-9294","1558-2531"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Engineering","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5088230475","display_name":"Jaime Punter-Villagrasa","orcid":"https://orcid.org/0000-0002-1875-7082"},"institutions":[{"id":"https://openalex.org/I71999127","display_name":"Universitat de Barcelona","ror":"https://ror.org/021018s57","country_code":"ES","type":"education","lineage":["https://openalex.org/I71999127"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Jaime Punter-Villagrasa","raw_affiliation_strings":["Department of Electronics, University of Barcelona, Barcelona, Spain","Department of  Electronics, University of  Barcelona, Barcelona, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electronics, University of Barcelona, Barcelona, Spain","institution_ids":["https://openalex.org/I71999127"]},{"raw_affiliation_string":"Department of  Electronics, University of  Barcelona, Barcelona, Spain","institution_ids":["https://openalex.org/I71999127"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5018652145","display_name":"Joan Cid","orcid":"https://orcid.org/0000-0001-5445-4508"},"institutions":[{"id":"https://openalex.org/I4210115097","display_name":"Hospital Cl\u00ednic de Barcelona","ror":"https://ror.org/02a2kzf50","country_code":"ES","type":"healthcare","lineage":["https://openalex.org/I4210115097"]},{"id":"https://openalex.org/I4210160192","display_name":"Consorci Institut D'Investigacions Biomediques August Pi I Sunyer","ror":"https://ror.org/054vayn55","country_code":"ES","type":"facility","lineage":["https://openalex.org/I4210160192","https://openalex.org/I4387153040"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Joan Cid","raw_affiliation_strings":["Department of Hemotherapy and Hemostasis, CDB, IDIBAPS, Hospital Cl\u00ednic, Barcelona, Spain","Department of Hemotherapy and Hemostasis, CDB, IDIBAPS, Hospital Clinic, Barcelona, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Hemotherapy and Hemostasis, CDB, IDIBAPS, Hospital Cl\u00ednic, Barcelona, Spain","institution_ids":["https://openalex.org/I4210115097","https://openalex.org/I4210160192"]},{"raw_affiliation_string":"Department of Hemotherapy and Hemostasis, CDB, IDIBAPS, Hospital Clinic, Barcelona, Spain","institution_ids":["https://openalex.org/I4210115097","https://openalex.org/I4210160192"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5053163153","display_name":"Jordi Colomer\u2010Farrarons","orcid":"https://orcid.org/0000-0001-9537-5363"},"institutions":[{"id":"https://openalex.org/I71999127","display_name":"Universitat de Barcelona","ror":"https://ror.org/021018s57","country_code":"ES","type":"education","lineage":["https://openalex.org/I71999127"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Jordi Colomer-Farrarons","raw_affiliation_strings":["Department of Electronics, University of Barcelona, Barcelona, Spain","Department of  Electronics, University of  Barcelona, Barcelona, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electronics, University of Barcelona, Barcelona, Spain","institution_ids":["https://openalex.org/I71999127"]},{"raw_affiliation_string":"Department of  Electronics, University of  Barcelona, Barcelona, Spain","institution_ids":["https://openalex.org/I71999127"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5022175592","display_name":"Angeles Iv\u00f3n Rodr\u00edguez-Villarreal","orcid":"https://orcid.org/0000-0001-7563-5113"},"institutions":[{"id":"https://openalex.org/I4210122226","display_name":"Centre de Recerca Matem\u00e0tica","ror":"https://ror.org/020s51w82","country_code":"ES","type":"facility","lineage":["https://openalex.org/I4210122226","https://openalex.org/I4387153040"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Ivon Rodriguez-Villarreal","raw_affiliation_strings":["Centre de Recerca Matem\u00e0tica, Campus Bellaterra, UAB, Barcelona, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Centre de Recerca Matem\u00e0tica, Campus Bellaterra, UAB, Barcelona, Spain","institution_ids":["https://openalex.org/I4210122226"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5046396071","display_name":"Pere Ll. Miribel\u2010Catal\u00e0","orcid":"https://orcid.org/0000-0002-2715-6684"},"institutions":[{"id":"https://openalex.org/I71999127","display_name":"Universitat de Barcelona","ror":"https://ror.org/021018s57","country_code":"ES","type":"education","lineage":["https://openalex.org/I71999127"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Pere Ll. Miribel-Catala","raw_affiliation_strings":["Department of Electronics, University of Barcelona, Barcelona, Spain","Department of  Electronics, University of  Barcelona, Barcelona, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electronics, University of Barcelona, Barcelona, Spain","institution_ids":["https://openalex.org/I71999127"]},{"raw_affiliation_string":"Department of  Electronics, University of  Barcelona, Barcelona, Spain","institution_ids":["https://openalex.org/I71999127"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.1543,"has_fulltext":false,"cited_by_count":17,"citation_normalized_percentile":{"value":0.77325798,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":97},"biblio":{"volume":"62","issue":"2","first_page":"708","last_page":"716"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11393","display_name":"Biosensors and Analytical Detection","score":0.9927999973297119,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11393","display_name":"Biosensors and Analytical Detection","score":0.9927999973297119,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11534","display_name":"Erythropoietin and Anemia Treatment","score":0.9873999953269958,"subfield":{"id":"https://openalex.org/subfields/2720","display_name":"Hematology"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11255","display_name":"Microfluidic and Bio-sensing Technologies","score":0.9668999910354614,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hematocrit","display_name":"Hematocrit","score":0.7384018898010254},{"id":"https://openalex.org/keywords/electrical-impedance","display_name":"Electrical impedance","score":0.5444608330726624},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.48742392659187317},{"id":"https://openalex.org/keywords/instrumentation","display_name":"Instrumentation (computer programming)","score":0.4760872423648834},{"id":"https://openalex.org/keywords/robustness","display_name":"Robustness (evolution)","score":0.46552178263664246},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.4517471492290497},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4198800027370453},{"id":"https://openalex.org/keywords/correlation-coefficient","display_name":"Correlation coefficient","score":0.41653239727020264},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.338525652885437},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.19354212284088135},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.17883417010307312},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.17815017700195312},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.1545315682888031},{"id":"https://openalex.org/keywords/statistics","display_name":"Statistics","score":0.11896610260009766}],"concepts":[{"id":"https://openalex.org/C2780959883","wikidata":"https://www.wikidata.org/wiki/Q111146","display_name":"Hematocrit","level":2,"score":0.7384018898010254},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.5444608330726624},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.48742392659187317},{"id":"https://openalex.org/C118530786","wikidata":"https://www.wikidata.org/wiki/Q1134732","display_name":"Instrumentation (computer programming)","level":2,"score":0.4760872423648834},{"id":"https://openalex.org/C63479239","wikidata":"https://www.wikidata.org/wiki/Q7353546","display_name":"Robustness (evolution)","level":3,"score":0.46552178263664246},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.4517471492290497},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4198800027370453},{"id":"https://openalex.org/C2780092901","wikidata":"https://www.wikidata.org/wiki/Q3433612","display_name":"Correlation coefficient","level":2,"score":0.41653239727020264},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.338525652885437},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.19354212284088135},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.17883417010307312},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.17815017700195312},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.1545315682888031},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.11896610260009766},{"id":"https://openalex.org/C104317684","wikidata":"https://www.wikidata.org/wiki/Q7187","display_name":"Gene","level":2,"score":0.0},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C55493867","wikidata":"https://www.wikidata.org/wiki/Q7094","display_name":"Biochemistry","level":1,"score":0.0},{"id":"https://openalex.org/C119857082","wikidata":"https://www.wikidata.org/wiki/Q2539","display_name":"Machine learning","level":1,"score":0.0},{"id":"https://openalex.org/C134018914","wikidata":"https://www.wikidata.org/wiki/Q162606","display_name":"Endocrinology","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000740","descriptor_name":"Anemia","qualifier_ui":"Q000097","qualifier_name":"blood","is_major_topic":false},{"descriptor_ui":"D000740","descriptor_name":"Anemia","qualifier_ui":"Q000097","qualifier_name":"blood","is_major_topic":false},{"descriptor_ui":"D000740","descriptor_name":"Anemia","qualifier_ui":"Q000097","qualifier_name":"blood","is_major_topic":false},{"descriptor_ui":"D000740","descriptor_name":"Anemia","qualifier_ui":"Q000175","qualifier_name":"diagnosis","is_major_topic":false},{"descriptor_ui":"D000740","descriptor_name":"Anemia","qualifier_ui":"Q000175","qualifier_name":"diagnosis","is_major_topic":false},{"descriptor_ui":"D000740","descriptor_name":"Anemia","qualifier_ui":"Q000175","qualifier_name":"diagnosis","is_major_topic":false},{"descriptor_ui":"D001800","descriptor_name":"Blood Specimen Collection","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D001800","descriptor_name":"Blood Specimen Collection","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D001800","descriptor_name":"Blood Specimen Collection","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D003217","descriptor_name":"Conductometry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D003217","descriptor_name":"Conductometry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D003217","descriptor_name":"Conductometry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D003936","descriptor_name":"Diagnosis, Computer-Assisted","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D003936","descriptor_name":"Diagnosis, Computer-Assisted","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D003936","descriptor_name":"Diagnosis, Computer-Assisted","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006400","descriptor_name":"Hematocrit","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D006400","descriptor_name":"Hematocrit","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D006400","descriptor_name":"Hematocrit","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015374","descriptor_name":"Biosensing Techniques","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D015374","descriptor_name":"Biosensing Techniques","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D015374","descriptor_name":"Biosensing Techniques","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":2,"locations":[{"id":"doi:10.1109/tbme.2014.2364139","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbme.2014.2364139","pdf_url":null,"source":{"id":"https://openalex.org/S5240358","display_name":"IEEE Transactions on Biomedical Engineering","issn_l":"0018-9294","issn":["0018-9294","1558-2531"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Engineering","raw_type":"journal-article"},{"id":"pmid:25347870","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/25347870","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE transactions on bio-medical engineering","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":32,"referenced_works":["https://openalex.org/W59740843","https://openalex.org/W111698270","https://openalex.org/W1494822764","https://openalex.org/W1564211964","https://openalex.org/W1976149114","https://openalex.org/W1984678825","https://openalex.org/W2001303976","https://openalex.org/W2003462976","https://openalex.org/W2006301078","https://openalex.org/W2011740056","https://openalex.org/W2031683385","https://openalex.org/W2037259160","https://openalex.org/W2039848065","https://openalex.org/W2044643064","https://openalex.org/W2078630936","https://openalex.org/W2085921704","https://openalex.org/W2086670935","https://openalex.org/W2089408283","https://openalex.org/W2107554411","https://openalex.org/W2112842799","https://openalex.org/W2118561029","https://openalex.org/W2121599855","https://openalex.org/W2125740139","https://openalex.org/W2139365628","https://openalex.org/W2160385211","https://openalex.org/W2162296091","https://openalex.org/W2181720777","https://openalex.org/W2319015327","https://openalex.org/W2498903837","https://openalex.org/W4302080842","https://openalex.org/W6678222199","https://openalex.org/W6724167950"],"related_works":["https://openalex.org/W297056630","https://openalex.org/W2994410525","https://openalex.org/W2054060818","https://openalex.org/W84640643","https://openalex.org/W2395601063","https://openalex.org/W3049608659","https://openalex.org/W2924434940","https://openalex.org/W2106083255","https://openalex.org/W1998168842","https://openalex.org/W2146417387"],"abstract_inverted_index":{"A":[0,203],"first":[1],"approach":[2],"to":[3,55,106,144,169,229],"a":[4,40,56,69,80,137,146,163,181,242],"portable":[5,226],"and":[6,46,65,127,176,201,222,241],"compact":[7],"device":[8,20,37,109,228],"for":[9,88,111,124,130,157,165,197],"point-of-care":[10],"(PoC)":[11],"early":[12],"instantaneous":[13],"detection":[14,168,173,205],"of":[15,33,39,62,178,224,239,244,246],"anemia":[16,112,231],"is":[17,77],"described.":[18],"This":[19,36],"works":[21],"directly":[22],"with":[23,68,191,235],"whole":[24,93],"blood":[25,94,115],"samples":[26,116,123,129,187],"relying":[27,207],"on":[28,79,208,215],"hematocrit":[29,158,204],"analysis":[30],"by":[31],"means":[32],"impedance":[34,148,167,183,199,209],"analysis.":[35],"consists":[38],"custom":[41],"electronic":[42],"instrumentation,":[43],"postprocessing":[44],"software":[45,72],"plug-and-play":[47],"disposable":[48,75],"sensor.":[49],"The":[50,74,219],"designed":[51],"electronics":[52],"are":[53],"connected":[54],"remote":[57],"computer,":[58],"which":[59],"allows":[60],"control":[61],"the":[63,108,135,171,216,225],"instrumentation":[64],"results":[66],"displaying":[67],"user":[70],"friendly":[71],"panel.":[73],"sensor":[76,87],"based":[78,214],"low-cost":[81],"label-free":[82],"three":[83],"gold":[84],"electrode":[85],"commercial":[86],"50-\u03bcL":[89],"volume":[90],"samples.":[91],"Forty-eight":[92],"samples,":[95],"randomly":[96],"collected":[97],"from":[98],"hospitalized":[99],"patients":[100],"in":[101,119],"Hospital":[102],"Cl\u00ednic,":[103],"were":[104,117],"used":[105],"validate":[107],"capability":[110],"detection.":[113,159],"Whole":[114],"distributed":[118],"two":[120],"groups:":[121],"10":[122],"system":[125,131,172],"calibration,":[126],"38":[128],"validation.":[132],"To":[133],"calibrate":[134],"device,":[136],"complete":[138],"EIS":[139],"experiment":[140],"has":[141,211],"been":[142,189,212,233],"performed":[143],"get":[145],"full":[147],"spectrum":[149],"analysis,":[150,210],"defining":[151],"an":[152,236],"accurate":[153],"frequency":[154],"working":[155],"range":[156],"Afterward,":[160],"we":[161],"developed":[162,213],"protocol":[164],"instant":[166],"determine":[170],"accuracy,":[174],"sensitivity,":[175],"coefficient":[177,243],"variation.":[179],"As":[180],"result,":[182],"variations":[184],"between":[185],"different":[186],"have":[188,232],"detected":[190],"less":[192,247],"than":[193,248],"2%":[194],"accuracy":[195,237],"error":[196,238],"both":[198],"magnitude":[200],"phase.":[202],"algorithm,":[206],"previous":[217],"studies.":[218],"response,":[220],"effectiveness,":[221],"robustness":[223],"PoC":[227],"detect":[230],"proved":[234],"1.75%":[240],"variation":[245],"5%.":[249]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":4},{"year":2019,"cited_by_count":2},{"year":2017,"cited_by_count":3},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":2}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
