{"id":"https://openalex.org/W2069439579","doi":"https://doi.org/10.1109/tbme.2013.2256134","title":"Analysis of the Spatial Sensitivity of Conductance/Admittance Catheter Ventricular Volume Estimation","display_name":"Analysis of the Spatial Sensitivity of Conductance/Admittance Catheter Ventricular Volume Estimation","publication_year":2013,"publication_date":"2013-04-01","ids":{"openalex":"https://openalex.org/W2069439579","doi":"https://doi.org/10.1109/tbme.2013.2256134","mag":"2069439579","pmid":"https://pubmed.ncbi.nlm.nih.gov/23559022"},"language":"en","primary_location":{"id":"doi:10.1109/tbme.2013.2256134","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbme.2013.2256134","pdf_url":null,"source":{"id":"https://openalex.org/S5240358","display_name":"IEEE Transactions on Biomedical Engineering","issn_l":"0018-9294","issn":["0018-9294","1558-2531"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Engineering","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5088340342","display_name":"Erik R. Larson","orcid":null},"institutions":[{"id":"https://openalex.org/I86519309","display_name":"The University of Texas at Austin","ror":"https://ror.org/00hj54h04","country_code":"US","type":"education","lineage":["https://openalex.org/I86519309"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Erik R. Larson","raw_affiliation_strings":["Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, TX 78712, USA. Larson@ece.utexas.edu","Department of Electrical and Computer Engineering, University of Texas, Austin, Austin, TX, USA"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, TX 78712, USA. Larson@ece.utexas.edu","institution_ids":["https://openalex.org/I86519309"]},{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Texas, Austin, Austin, TX, USA","institution_ids":["https://openalex.org/I86519309"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5103434271","display_name":"Marc D. Feldman","orcid":null},"institutions":[{"id":"https://openalex.org/I4210144081","display_name":"South Texas Veterans Health Care System","ror":"https://ror.org/03n2ay196","country_code":"US","type":"healthcare","lineage":["https://openalex.org/I1322918889","https://openalex.org/I2799886695","https://openalex.org/I4210144023","https://openalex.org/I4210144081"]},{"id":"https://openalex.org/I165951966","display_name":"The University of Texas Health Science Center at San Antonio","ror":"https://ror.org/02f6dcw23","country_code":"US","type":"education","lineage":["https://openalex.org/I165951966"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Marc D. Feldman","raw_affiliation_strings":["Department of Veterans Affairs, South Texas Veterans Health Care System, San Antonio, TX, USA","Division of Cardiology, University of Texas Health Science Center at San Antonio, San Antonio, TX, USA"],"affiliations":[{"raw_affiliation_string":"Department of Veterans Affairs, South Texas Veterans Health Care System, San Antonio, TX, USA","institution_ids":["https://openalex.org/I4210144081"]},{"raw_affiliation_string":"Division of Cardiology, University of Texas Health Science Center at San Antonio, San Antonio, TX, USA","institution_ids":["https://openalex.org/I165951966"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5017303849","display_name":"Jonathan W. Valvano","orcid":null},"institutions":[{"id":"https://openalex.org/I86519309","display_name":"The University of Texas at Austin","ror":"https://ror.org/00hj54h04","country_code":"US","type":"education","lineage":["https://openalex.org/I86519309"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Jonathan W. Valvano","raw_affiliation_strings":["Department of Electrical and Computer Engineering, University of Texas, Austin, Austin, TX, USA"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Texas, Austin, Austin, TX, USA","institution_ids":["https://openalex.org/I86519309"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5038309597","display_name":"John A. Pearce","orcid":"https://orcid.org/0000-0002-4840-4560"},"institutions":[{"id":"https://openalex.org/I86519309","display_name":"The University of Texas at Austin","ror":"https://ror.org/00hj54h04","country_code":"US","type":"education","lineage":["https://openalex.org/I86519309"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"John A. Pearce","raw_affiliation_strings":["Department of Electrical and Computer Engineering, University of Texas, Austin, Austin, TX, USA"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Texas, Austin, Austin, TX, USA","institution_ids":["https://openalex.org/I86519309"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5088340342"],"corresponding_institution_ids":["https://openalex.org/I86519309"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":10,"citation_normalized_percentile":{"value":0.12474646,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":"60","issue":"8","first_page":"2316","last_page":"2324"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11778","display_name":"Electrical and Bioimpedance Tomography","score":0.9983000159263611,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11778","display_name":"Electrical and Bioimpedance Tomography","score":0.9983000159263611,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10217","display_name":"Cardiac electrophysiology and arrhythmias","score":0.9973000288009644,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10821","display_name":"Cardiovascular Function and Risk Factors","score":0.9966999888420105,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.6954978108406067},{"id":"https://openalex.org/keywords/conductance","display_name":"Conductance","score":0.6365205645561218},{"id":"https://openalex.org/keywords/admittance","display_name":"Admittance","score":0.596329391002655},{"id":"https://openalex.org/keywords/mathematical-analysis","display_name":"Mathematical analysis","score":0.42688053846359253},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.41070273518562317},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.40052884817123413},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.3403714895248413},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.23063620924949646},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.16093841195106506},{"id":"https://openalex.org/keywords/condensed-matter-physics","display_name":"Condensed matter physics","score":0.09329506754875183},{"id":"https://openalex.org/keywords/quantum-mechanics","display_name":"Quantum mechanics","score":0.08980655670166016}],"concepts":[{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.6954978108406067},{"id":"https://openalex.org/C121932024","wikidata":"https://www.wikidata.org/wiki/Q5159376","display_name":"Conductance","level":2,"score":0.6365205645561218},{"id":"https://openalex.org/C108811297","wikidata":"https://www.wikidata.org/wiki/Q214518","display_name":"Admittance","level":3,"score":0.596329391002655},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.42688053846359253},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.41070273518562317},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.40052884817123413},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.3403714895248413},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.23063620924949646},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.16093841195106506},{"id":"https://openalex.org/C26873012","wikidata":"https://www.wikidata.org/wiki/Q214781","display_name":"Condensed matter physics","level":1,"score":0.09329506754875183},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.08980655670166016},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.0}],"mesh":[{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000818","descriptor_name":"Animals","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000818","descriptor_name":"Animals","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000818","descriptor_name":"Animals","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006352","descriptor_name":"Heart Ventricles","qualifier_ui":"Q000033","qualifier_name":"anatomy & histology","is_major_topic":false},{"descriptor_ui":"D006352","descriptor_name":"Heart Ventricles","qualifier_ui":"Q000033","qualifier_name":"anatomy & histology","is_major_topic":false},{"descriptor_ui":"D006352","descriptor_name":"Heart Ventricles","qualifier_ui":"Q000033","qualifier_name":"anatomy & histology","is_major_topic":false},{"descriptor_ui":"D009929","descriptor_name":"Organ Size","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D009929","descriptor_name":"Organ Size","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D009929","descriptor_name":"Organ Size","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D010992","descriptor_name":"Plethysmography, Impedance","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D010992","descriptor_name":"Plethysmography, Impedance","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D010992","descriptor_name":"Plethysmography, Impedance","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013318","descriptor_name":"Stroke Volume","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D013318","descriptor_name":"Stroke Volume","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D013318","descriptor_name":"Stroke Volume","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D016277","descriptor_name":"Ventricular Function, Left","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D016277","descriptor_name":"Ventricular Function, Left","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D016277","descriptor_name":"Ventricular Function, Left","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D017097","descriptor_name":"Electric Impedance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017097","descriptor_name":"Electric Impedance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017097","descriptor_name":"Electric Impedance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D051379","descriptor_name":"Mice","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D051379","descriptor_name":"Mice","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D051379","descriptor_name":"Mice","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D062211","descriptor_name":"Spatio-Temporal Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D062211","descriptor_name":"Spatio-Temporal Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D062211","descriptor_name":"Spatio-Temporal Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D062906","descriptor_name":"Cardiac Catheters","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D062906","descriptor_name":"Cardiac Catheters","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D062906","descriptor_name":"Cardiac Catheters","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true}],"locations_count":2,"locations":[{"id":"doi:10.1109/tbme.2013.2256134","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbme.2013.2256134","pdf_url":null,"source":{"id":"https://openalex.org/S5240358","display_name":"IEEE Transactions on Biomedical Engineering","issn_l":"0018-9294","issn":["0018-9294","1558-2531"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Engineering","raw_type":"journal-article"},{"id":"pmid:23559022","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/23559022","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE transactions on bio-medical engineering","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320310620","display_name":"University of Texas at Austin","ror":"https://ror.org/00hj54h04"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":15,"referenced_works":["https://openalex.org/W1979724394","https://openalex.org/W2022981781","https://openalex.org/W2042694408","https://openalex.org/W2097364562","https://openalex.org/W2101550277","https://openalex.org/W2102585418","https://openalex.org/W2116504158","https://openalex.org/W2122304789","https://openalex.org/W2123284157","https://openalex.org/W2127923590","https://openalex.org/W2137930751","https://openalex.org/W2149516019","https://openalex.org/W2156041375","https://openalex.org/W2164856839","https://openalex.org/W2281019573"],"related_works":["https://openalex.org/W2367857055","https://openalex.org/W2047335472","https://openalex.org/W2021013760","https://openalex.org/W3180133250","https://openalex.org/W2363278848","https://openalex.org/W2031634947","https://openalex.org/W1999989966","https://openalex.org/W2024162929","https://openalex.org/W2051487156","https://openalex.org/W1984393333"],"abstract_inverted_index":{"Conductance":[0],"catheters":[1,28],"are":[2],"known":[3],"to":[4,11,23,33,59,109,114,127,174],"have":[5],"a":[6,39,72,169],"nonuniform":[7],"spatial":[8,36,57,94],"sensitivity":[9,37,58,95,173],"due":[10],"the":[12,15,35,56,68,86,103,117,122,128,138,144,149,175,187],"distribution":[13],"of":[14,55,62,75,85,96,119],"electric":[16,129],"field.":[17,130],"The":[18,93,179],"Geselowitz":[19,69,145],"relation":[20,70,146],"is":[21,50,100,107,155],"applied":[22],"murine":[24,192],"and":[25,42,89,147,153,193],"multisegment":[26,194],"conductance":[27,77,98,135,185,195],"using":[29,67,111,158],"finite":[30],"element":[31],"models":[32,82],"determine":[34,115],"in":[38,78,164,168,190],"uniform":[40],"medium":[41],"simplified":[43,79],"left":[44,80],"ventricle":[45,81],"models.":[46],"A":[47],"new":[48],"formulation":[49],"proposed":[51],"that":[52,133,148],"allows":[53],"determination":[54],"admittance.":[60],"Analysis":[61],"FEM":[63],"numerical":[64],"modeling":[65],"results":[66,142],"provides":[71],"true":[73],"measure":[74],"parallel":[76,184],"for":[83],"assessment":[84],"admittance":[87,139,162],"method":[88,140,182],"hypertonic":[90,180],"saline":[91,181],"techniques.":[92],"blood":[97,177],"(Gb)":[99],"determined":[101],"throughout":[102,186],"cardiac":[104,188],"cycle.":[105],"Gb":[106,152],"converted":[108],"volume":[110,154],"Wei's":[112,159],"equation":[113],"if":[116],"presence":[118],"myocardium":[120],"alters":[121],"nonlinear":[123],"relationship":[124,150],"through":[125],"changes":[126],"Results":[131],"show":[132],"muscle":[134],"(Gm)":[136],"from":[137,143],"matches":[141],"between":[151],"accurately":[156],"fit":[157],"equation.":[160],"Single-segment":[161],"measurements":[163],"large":[165],"animals":[166],"result":[167],"more":[170],"evenly":[171],"distributed":[172],"LV":[176],"pool.":[178],"overestimates":[183],"cycle":[189],"both":[191],"catheters.":[196]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":1},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":1},{"year":2017,"cited_by_count":1}],"updated_date":"2026-01-13T01:12:25.745995","created_date":"2025-10-10T00:00:00"}
