{"id":"https://openalex.org/W2066744005","doi":"https://doi.org/10.1109/tbme.2011.2177268","title":"A New Solution for Camera Calibration and Real-Time Image Distortion Correction in Medical Endoscopy\u2013Initial Technical Evaluation","display_name":"A New Solution for Camera Calibration and Real-Time Image Distortion Correction in Medical Endoscopy\u2013Initial Technical Evaluation","publication_year":2011,"publication_date":"2011-11-23","ids":{"openalex":"https://openalex.org/W2066744005","doi":"https://doi.org/10.1109/tbme.2011.2177268","mag":"2066744005","pmid":"https://pubmed.ncbi.nlm.nih.gov/22127990"},"language":"en","primary_location":{"id":"doi:10.1109/tbme.2011.2177268","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbme.2011.2177268","pdf_url":null,"source":{"id":"https://openalex.org/S5240358","display_name":"IEEE Transactions on Biomedical Engineering","issn_l":"0018-9294","issn":["0018-9294","1558-2531"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Engineering","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5021498625","display_name":"Ricardo Melo","orcid":"https://orcid.org/0000-0002-3186-3752"},"institutions":[{"id":"https://openalex.org/I4210125590","display_name":"Institute for Systems Engineering and Computers","ror":"https://ror.org/033wn8m60","country_code":"PT","type":"nonprofit","lineage":["https://openalex.org/I4210125590"]},{"id":"https://openalex.org/I76903346","display_name":"University of Coimbra","ror":"https://ror.org/04z8k9a98","country_code":"PT","type":"education","lineage":["https://openalex.org/I76903346"]}],"countries":["PT"],"is_corresponding":false,"raw_author_name":"R. Melo","raw_affiliation_strings":["Institute for Systems and Robotics, Faculty of Science and Technology, University of Coimbra, Coimbra, Portugal. rmelo@isr.uc.pt","Institute for Systems and Robotics and Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Coimbra, 3030-290 Coimbra, Portugal"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute for Systems and Robotics, Faculty of Science and Technology, University of Coimbra, Coimbra, Portugal. rmelo@isr.uc.pt","institution_ids":["https://openalex.org/I4210125590","https://openalex.org/I76903346"]},{"raw_affiliation_string":"Institute for Systems and Robotics and Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Coimbra, 3030-290 Coimbra, Portugal","institution_ids":["https://openalex.org/I76903346"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5069598704","display_name":"Jo\u00e3o P. Barreto","orcid":"https://orcid.org/0000-0001-5220-9170"},"institutions":[{"id":"https://openalex.org/I4210125590","display_name":"Institute for Systems Engineering and Computers","ror":"https://ror.org/033wn8m60","country_code":"PT","type":"nonprofit","lineage":["https://openalex.org/I4210125590"]},{"id":"https://openalex.org/I76903346","display_name":"University of Coimbra","ror":"https://ror.org/04z8k9a98","country_code":"PT","type":"education","lineage":["https://openalex.org/I76903346"]}],"countries":["PT"],"is_corresponding":false,"raw_author_name":"J. P. Barreto","raw_affiliation_strings":["Institute for Systems and Robotics and Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Coimbra, Coimbra, Portugal","Institute for Systems and Robotics and Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Coimbra, 3030-290 Coimbra, Portugal"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute for Systems and Robotics and Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Coimbra, Coimbra, Portugal","institution_ids":["https://openalex.org/I4210125590","https://openalex.org/I76903346"]},{"raw_affiliation_string":"Institute for Systems and Robotics and Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Coimbra, 3030-290 Coimbra, Portugal","institution_ids":["https://openalex.org/I76903346"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5088848663","display_name":"Gabriel Falc\u00e3o","orcid":"https://orcid.org/0000-0001-9805-6747"},"institutions":[{"id":"https://openalex.org/I76903346","display_name":"University of Coimbra","ror":"https://ror.org/04z8k9a98","country_code":"PT","type":"education","lineage":["https://openalex.org/I76903346"]}],"countries":["PT"],"is_corresponding":false,"raw_author_name":"G. Falcao","raw_affiliation_strings":["Instituto de Telecommunica\u00e7\u00f5es and Robotics, Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Coimbra, Coimbra, Portugal","Instituto de Telecomunica\u00e7\u00f5es and Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Coimbra, 3030-290 Coimbra, Portugal"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Instituto de Telecommunica\u00e7\u00f5es and Robotics, Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Coimbra, Coimbra, Portugal","institution_ids":["https://openalex.org/I76903346"]},{"raw_affiliation_string":"Instituto de Telecomunica\u00e7\u00f5es and Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Coimbra, 3030-290 Coimbra, Portugal","institution_ids":["https://openalex.org/I76903346"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":10.2236,"has_fulltext":false,"cited_by_count":90,"citation_normalized_percentile":{"value":0.98614015,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":90,"max":100},"biblio":{"volume":"59","issue":"3","first_page":"634","last_page":"644"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10638","display_name":"Optical measurement and interference techniques","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/1707","display_name":"Computer Vision and Pattern Recognition"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10638","display_name":"Optical measurement and interference techniques","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/1707","display_name":"Computer Vision and Pattern Recognition"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10531","display_name":"Advanced Vision and Imaging","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/1707","display_name":"Computer Vision and Pattern Recognition"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11211","display_name":"3D Surveying and Cultural Heritage","score":0.9965999722480774,"subfield":{"id":"https://openalex.org/subfields/1907","display_name":"Geology"},"field":{"id":"https://openalex.org/fields/19","display_name":"Earth and Planetary Sciences"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-vision","display_name":"Computer vision","score":0.8105592727661133},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.7456871271133423},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7115008234977722},{"id":"https://openalex.org/keywords/image-warping","display_name":"Image warping","score":0.6062846779823303},{"id":"https://openalex.org/keywords/camera-resectioning","display_name":"Camera resectioning","score":0.5160865187644958},{"id":"https://openalex.org/keywords/software","display_name":"Software","score":0.46380022168159485},{"id":"https://openalex.org/keywords/robustness","display_name":"Robustness (evolution)","score":0.45291611552238464},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.4233092665672302},{"id":"https://openalex.org/keywords/image-rectification","display_name":"Image rectification","score":0.419254332780838},{"id":"https://openalex.org/keywords/distortion","display_name":"Distortion (music)","score":0.41442179679870605},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.10094267129898071},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.08953121304512024}],"concepts":[{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.8105592727661133},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.7456871271133423},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7115008234977722},{"id":"https://openalex.org/C157202957","wikidata":"https://www.wikidata.org/wiki/Q1659609","display_name":"Image warping","level":2,"score":0.6062846779823303},{"id":"https://openalex.org/C110898773","wikidata":"https://www.wikidata.org/wiki/Q2933935","display_name":"Camera resectioning","level":2,"score":0.5160865187644958},{"id":"https://openalex.org/C2777904410","wikidata":"https://www.wikidata.org/wiki/Q7397","display_name":"Software","level":2,"score":0.46380022168159485},{"id":"https://openalex.org/C63479239","wikidata":"https://www.wikidata.org/wiki/Q7353546","display_name":"Robustness (evolution)","level":3,"score":0.45291611552238464},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.4233092665672302},{"id":"https://openalex.org/C171614847","wikidata":"https://www.wikidata.org/wiki/Q1262415","display_name":"Image rectification","level":4,"score":0.419254332780838},{"id":"https://openalex.org/C126780896","wikidata":"https://www.wikidata.org/wiki/Q899871","display_name":"Distortion (music)","level":4,"score":0.41442179679870605},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.10094267129898071},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.08953121304512024},{"id":"https://openalex.org/C104317684","wikidata":"https://www.wikidata.org/wiki/Q7187","display_name":"Gene","level":2,"score":0.0},{"id":"https://openalex.org/C55493867","wikidata":"https://www.wikidata.org/wiki/Q7094","display_name":"Biochemistry","level":1,"score":0.0},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.0},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.0},{"id":"https://openalex.org/C50942859","wikidata":"https://www.wikidata.org/wiki/Q4967193","display_name":"Rectification","level":3,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.0},{"id":"https://openalex.org/C2776257435","wikidata":"https://www.wikidata.org/wiki/Q1576430","display_name":"Bandwidth (computing)","level":2,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C194257627","wikidata":"https://www.wikidata.org/wiki/Q211554","display_name":"Amplifier","level":3,"score":0.0}],"mesh":[{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D002138","descriptor_name":"Calibration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D002138","descriptor_name":"Calibration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D002138","descriptor_name":"Calibration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007089","descriptor_name":"Image Enhancement","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D007089","descriptor_name":"Image Enhancement","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D007089","descriptor_name":"Image Enhancement","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D011786","descriptor_name":"Quality Control","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011786","descriptor_name":"Quality Control","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011786","descriptor_name":"Quality Control","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012984","descriptor_name":"Software","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D012984","descriptor_name":"Software","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D012984","descriptor_name":"Software","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019723","descriptor_name":"Endoscopes","qualifier_ui":"Q000592","qualifier_name":"standards","is_major_topic":false},{"descriptor_ui":"D019723","descriptor_name":"Endoscopes","qualifier_ui":"Q000592","qualifier_name":"standards","is_major_topic":false},{"descriptor_ui":"D019723","descriptor_name":"Endoscopes","qualifier_ui":"Q000592","qualifier_name":"standards","is_major_topic":false},{"descriptor_ui":"D021621","descriptor_name":"Imaging, Three-Dimensional","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D021621","descriptor_name":"Imaging, Three-Dimensional","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D021621","descriptor_name":"Imaging, Three-Dimensional","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D055095","descriptor_name":"Optics and Photonics","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D055095","descriptor_name":"Optics and Photonics","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D055095","descriptor_name":"Optics and Photonics","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true}],"locations_count":2,"locations":[{"id":"doi:10.1109/tbme.2011.2177268","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbme.2011.2177268","pdf_url":null,"source":{"id":"https://openalex.org/S5240358","display_name":"IEEE Transactions on Biomedical Engineering","issn_l":"0018-9294","issn":["0018-9294","1558-2531"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Engineering","raw_type":"journal-article"},{"id":"pmid:22127990","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/22127990","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE transactions on bio-medical engineering","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":31,"referenced_works":["https://openalex.org/W113485662","https://openalex.org/W1494063313","https://openalex.org/W1529711420","https://openalex.org/W1549881972","https://openalex.org/W1555136684","https://openalex.org/W1574937474","https://openalex.org/W1642770566","https://openalex.org/W1762731526","https://openalex.org/W1791880080","https://openalex.org/W2027189170","https://openalex.org/W2033819227","https://openalex.org/W2077629522","https://openalex.org/W2085261163","https://openalex.org/W2092270448","https://openalex.org/W2092360232","https://openalex.org/W2095614026","https://openalex.org/W2105623448","https://openalex.org/W2107192978","https://openalex.org/W2133805565","https://openalex.org/W2140427427","https://openalex.org/W2155799618","https://openalex.org/W2209124607","https://openalex.org/W2398736067","https://openalex.org/W2435209062","https://openalex.org/W2525469020","https://openalex.org/W2766798115","https://openalex.org/W2811290090","https://openalex.org/W6629629120","https://openalex.org/W6634627678","https://openalex.org/W6683079020","https://openalex.org/W6753042126"],"related_works":["https://openalex.org/W2035780481","https://openalex.org/W2143630701","https://openalex.org/W2389828343","https://openalex.org/W2100276092","https://openalex.org/W2541128885","https://openalex.org/W1979149155","https://openalex.org/W2116241442","https://openalex.org/W2006640513","https://openalex.org/W2015577017","https://openalex.org/W2134569597"],"abstract_inverted_index":{"Medical":[0],"endoscopy":[1,74],"is":[2,101,148,172],"used":[3,82],"in":[4,52,72,75,103,118,196],"a":[5,61,108,125],"wide":[6],"variety":[7],"of":[8,20,34,40,86,138,180],"diagnostic":[9],"and":[10,24,48,55,67,93,131,153,182,186,199,211],"surgical":[11],"procedures.":[12],"These":[13],"procedures":[14],"are":[15,122,191],"renowned":[16],"for":[17,166,174,194],"the":[18,22,27,35,41,45,69,116,136,139,151],"difficulty":[19],"orienting":[21],"camera":[23,99,128],"instruments":[25],"inside":[26],"human":[28],"body":[29],"cavities.":[30],"The":[31,97,146,170,189],"small":[32],"size":[33],"lens":[36,141],"causes":[37],"radial":[38,70],"distortion":[39,71],"image,":[42],"which":[43],"hinders":[44],"navigation":[46],"process":[47],"leads":[49],"to":[50,65],"errors":[51],"depth":[53],"perception":[54],"object":[56],"morphology.":[57],"This":[58,161],"article":[59],"presents":[60],"complete":[62],"software-based":[63],"system":[64,79,171],"calibrate":[66],"correct":[68],"clinical":[73],"real":[76],"time.":[77],"Our":[78],"can":[80],"be":[81],"with":[83],"any":[84],"type":[85],"medical":[87],"endoscopic":[88],"technology,":[89],"including":[90,178],"oblique-viewing":[91,114],"endoscopes":[92,115],"HD":[94,167],"image":[95,144,207],"acquisition.":[96],"initial":[98],"calibration":[100,119],"performed":[102],"an":[104,132,156],"unsupervised":[105],"manner":[106],"from":[107],"single":[109],"checkerboard":[110],"pattern":[111],"image.":[112],"For":[113],"changes":[117],"during":[120],"operation":[121],"handled":[123],"by":[124,206],"new":[126],"adaptive":[127],"projection":[129],"model":[130],"algorithm":[133],"that":[134],"infer":[135],"rotation":[137],"probe":[140],"using":[142],"only":[143],"information.":[145],"workload":[147],"distributed":[149],"across":[150],"CPU":[152],"GPU":[154],"through":[155],"optimized":[157],"CPU+GPU":[158],"hybrid":[159],"solution.":[160],"enables":[162],"real-time":[163],"performance,":[164],"even":[165],"video":[168],"inputs.":[169],"evaluated":[173],"different":[175],"technical":[176],"aspects,":[177],"accuracy":[179],"modeling":[181],"calibration,":[183],"overall":[184],"robustness,":[185],"runtime":[187],"profile.":[188],"contributions":[190],"highly":[192],"relevant":[193],"applications":[195],"computer-aided":[197],"surgery":[198],"image-guided":[200],"intervention":[201],"such":[202],"as":[203],"improved":[204],"visualization":[205],"warping,":[208],"3-D":[209],"modeling,":[210],"visual":[212],"SLAM.":[213]},"counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":5},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":4},{"year":2018,"cited_by_count":6},{"year":2017,"cited_by_count":7},{"year":2016,"cited_by_count":10},{"year":2015,"cited_by_count":10},{"year":2014,"cited_by_count":21},{"year":2013,"cited_by_count":11},{"year":2012,"cited_by_count":5}],"updated_date":"2026-08-09T07:27:16.801131","created_date":"2025-10-10T00:00:00"}
