{"id":"https://openalex.org/W2042177006","doi":"https://doi.org/10.1109/tbme.2011.2172441","title":"Improved Radiometric Performance Attained by an Elliptical Microwave Antenna With Suction","display_name":"Improved Radiometric Performance Attained by an Elliptical Microwave Antenna With Suction","publication_year":2011,"publication_date":"2011-10-18","ids":{"openalex":"https://openalex.org/W2042177006","doi":"https://doi.org/10.1109/tbme.2011.2172441","mag":"2042177006","pmid":"https://pubmed.ncbi.nlm.nih.gov/22020663"},"language":"en","primary_location":{"id":"doi:10.1109/tbme.2011.2172441","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbme.2011.2172441","pdf_url":null,"source":{"id":"https://openalex.org/S5240358","display_name":"IEEE Transactions on Biomedical Engineering","issn_l":"0018-9294","issn":["0018-9294","1558-2531"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Engineering","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5091128998","display_name":"\u00d8ystein Klemetsen","orcid":null},"institutions":[{"id":"https://openalex.org/I78037679","display_name":"UiT The Arctic University of Norway","ror":"https://ror.org/00wge5k78","country_code":"NO","type":"education","lineage":["https://openalex.org/I78037679"]}],"countries":["NO"],"is_corresponding":true,"raw_author_name":"O. Klemetsen","raw_affiliation_strings":["Dept. of Phys. & Technol., Univ. of Tromso, Troms\u00f8, Norway"],"affiliations":[{"raw_affiliation_string":"Dept. of Phys. & Technol., Univ. of Tromso, Troms\u00f8, Norway","institution_ids":["https://openalex.org/I78037679"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5022139466","display_name":"Sven Jacobsen","orcid":"https://orcid.org/0000-0003-4810-4186"},"institutions":[{"id":"https://openalex.org/I78037679","display_name":"UiT The Arctic University of Norway","ror":"https://ror.org/00wge5k78","country_code":"NO","type":"education","lineage":["https://openalex.org/I78037679"]}],"countries":["NO"],"is_corresponding":false,"raw_author_name":"S. Jacobsen","raw_affiliation_strings":["Department of Physics and Technology, Faculty of Science and Technology, University of Troms\u00f8, Tromso, Norway","Dept. of Phys. & Technol., Univ. of Tromso, Troms\u00f8, Norway"],"affiliations":[{"raw_affiliation_string":"Department of Physics and Technology, Faculty of Science and Technology, University of Troms\u00f8, Tromso, Norway","institution_ids":["https://openalex.org/I78037679"]},{"raw_affiliation_string":"Dept. of Phys. & Technol., Univ. of Tromso, Troms\u00f8, Norway","institution_ids":["https://openalex.org/I78037679"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5091128998"],"corresponding_institution_ids":["https://openalex.org/I78037679"],"apc_list":null,"apc_paid":null,"fwci":0.2233,"has_fulltext":false,"cited_by_count":23,"citation_normalized_percentile":{"value":0.57440489,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":"59","issue":"1","first_page":"263","last_page":"271"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10958","display_name":"Ultrasound and Hyperthermia Applications","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10958","display_name":"Ultrasound and Hyperthermia Applications","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12994","display_name":"Infrared Thermography in Medicine","score":0.9972000122070312,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11932","display_name":"Wireless Body Area Networks","score":0.9966999888420105,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/antenna","display_name":"Antenna (radio)","score":0.6470804810523987},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.506492018699646},{"id":"https://openalex.org/keywords/microwave","display_name":"Microwave","score":0.49883484840393066},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.49755004048347473},{"id":"https://openalex.org/keywords/antenna-measurement","display_name":"Antenna measurement","score":0.48762550950050354},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.4785890579223633},{"id":"https://openalex.org/keywords/suction","display_name":"Suction","score":0.47122490406036377},{"id":"https://openalex.org/keywords/radiation-pattern","display_name":"Radiation pattern","score":0.4518248438835144},{"id":"https://openalex.org/keywords/antenna-factor","display_name":"Antenna factor","score":0.41930148005485535},{"id":"https://openalex.org/keywords/antenna-noise-temperature","display_name":"Antenna noise temperature","score":0.415114164352417},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.2886885404586792},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.16995245218276978},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.15857046842575073},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.13761156797409058},{"id":"https://openalex.org/keywords/meteorology","display_name":"Meteorology","score":0.08092039823532104}],"concepts":[{"id":"https://openalex.org/C21822782","wikidata":"https://www.wikidata.org/wiki/Q131214","display_name":"Antenna (radio)","level":2,"score":0.6470804810523987},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.506492018699646},{"id":"https://openalex.org/C44838205","wikidata":"https://www.wikidata.org/wiki/Q127995","display_name":"Microwave","level":2,"score":0.49883484840393066},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.49755004048347473},{"id":"https://openalex.org/C158616128","wikidata":"https://www.wikidata.org/wiki/Q4771260","display_name":"Antenna measurement","level":3,"score":0.48762550950050354},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.4785890579223633},{"id":"https://openalex.org/C23795335","wikidata":"https://www.wikidata.org/wiki/Q1790295","display_name":"Suction","level":2,"score":0.47122490406036377},{"id":"https://openalex.org/C151764478","wikidata":"https://www.wikidata.org/wiki/Q571921","display_name":"Radiation pattern","level":3,"score":0.4518248438835144},{"id":"https://openalex.org/C196931383","wikidata":"https://www.wikidata.org/wiki/Q4771253","display_name":"Antenna factor","level":4,"score":0.41930148005485535},{"id":"https://openalex.org/C72816602","wikidata":"https://www.wikidata.org/wiki/Q1440723","display_name":"Antenna noise temperature","level":5,"score":0.415114164352417},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.2886885404586792},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.16995245218276978},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.15857046842575073},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.13761156797409058},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.08092039823532104}],"mesh":[{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008872","descriptor_name":"Microwaves","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D008872","descriptor_name":"Microwaves","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D008872","descriptor_name":"Microwaves","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D011874","descriptor_name":"Radiometry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D011874","descriptor_name":"Radiometry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D011874","descriptor_name":"Radiometry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013817","descriptor_name":"Thermography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D013817","descriptor_name":"Thermography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D013817","descriptor_name":"Thermography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D014159","descriptor_name":"Transducers","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D014159","descriptor_name":"Transducers","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D014159","descriptor_name":"Transducers","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D014618","descriptor_name":"Vacuum","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014618","descriptor_name":"Vacuum","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014618","descriptor_name":"Vacuum","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D018670","descriptor_name":"Monitoring, Ambulatory","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D018670","descriptor_name":"Monitoring, Ambulatory","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D018670","descriptor_name":"Monitoring, Ambulatory","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":2,"locations":[{"id":"doi:10.1109/tbme.2011.2172441","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbme.2011.2172441","pdf_url":null,"source":{"id":"https://openalex.org/S5240358","display_name":"IEEE Transactions on Biomedical Engineering","issn_l":"0018-9294","issn":["0018-9294","1558-2531"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Engineering","raw_type":"journal-article"},{"id":"pmid:22020663","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/22020663","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE transactions on bio-medical engineering","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.699999988079071,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":50,"referenced_works":["https://openalex.org/W608603759","https://openalex.org/W1491006673","https://openalex.org/W1564384403","https://openalex.org/W1979512319","https://openalex.org/W1984959895","https://openalex.org/W1985280311","https://openalex.org/W1987293964","https://openalex.org/W1988390438","https://openalex.org/W1995374017","https://openalex.org/W2013434109","https://openalex.org/W2018743450","https://openalex.org/W2035282752","https://openalex.org/W2039084229","https://openalex.org/W2047922146","https://openalex.org/W2057580083","https://openalex.org/W2058871194","https://openalex.org/W2068756118","https://openalex.org/W2073649142","https://openalex.org/W2076084974","https://openalex.org/W2078121922","https://openalex.org/W2091403031","https://openalex.org/W2100687266","https://openalex.org/W2100693022","https://openalex.org/W2103830439","https://openalex.org/W2109629458","https://openalex.org/W2110150748","https://openalex.org/W2111233911","https://openalex.org/W2111299585","https://openalex.org/W2119503040","https://openalex.org/W2132111028","https://openalex.org/W2133643452","https://openalex.org/W2141443936","https://openalex.org/W2151627613","https://openalex.org/W2155362932","https://openalex.org/W2157458514","https://openalex.org/W2163870939","https://openalex.org/W2166632265","https://openalex.org/W2167928131","https://openalex.org/W2169367099","https://openalex.org/W2314135032","https://openalex.org/W2414326714","https://openalex.org/W2474563639","https://openalex.org/W2496318089","https://openalex.org/W2497291658","https://openalex.org/W2798565554","https://openalex.org/W4229594554","https://openalex.org/W4285719527","https://openalex.org/W6618802207","https://openalex.org/W6698627782","https://openalex.org/W6720660431"],"related_works":["https://openalex.org/W2132188259","https://openalex.org/W2343010124","https://openalex.org/W2148610902","https://openalex.org/W1993240873","https://openalex.org/W2145615635","https://openalex.org/W2178819301","https://openalex.org/W2561575527","https://openalex.org/W2107089995","https://openalex.org/W2183561723","https://openalex.org/W2127228721"],"abstract_inverted_index":{"We":[0],"present":[1],"a":[2,8,91,120],"new":[3],"way":[4],"to":[5,35,74,105,136],"securely":[6],"mount":[7],"medical":[9],"microwave":[10,23],"antenna":[11,46,60,84,109,145,162],"onto":[12],"the":[13,41,59,63,66,83,107,124,131,143,153,161],"human":[14],"body":[15,159],"for":[16,170],"improved":[17,55,150,171],"in":[18,87,123],"vivo":[19],"temperature":[20,79],"measurements":[21,80],"by":[22,81],"radiometry.":[24],"A":[25],"low":[26],"cost":[27],"and":[28,62,101,114,149],"simple":[29],"vacuum":[30,48,144],"pressure":[31],"source":[32],"is":[33,71],"used":[34,104],"provide":[36],"suction":[37,108,134],"(negative":[38],"pressure)":[39],"on":[40,90],"aperture":[42],"of":[43,65,77,127,133,152],"an":[44],"elliptical":[45],"with":[47,130],"chamber":[49],"cavity":[50],"backing.":[51],"The":[52,68],"concept":[53,110],"offers":[54],"electromechanical":[56],"coupling":[57],"between":[58],"surface":[61],"skin":[64],"body.":[67],"proposed":[69],"solution":[70],"evaluated":[72],"experimentally":[73],"test":[75,106],"repeatability":[76],"radiometric":[78],"remounting":[82],"many":[85],"times":[86],"one":[88],"sequence":[89],"given":[92],"anatomical":[93,112],"location.":[94],"Four":[95],"representative":[96],"locations":[97],"(hand,":[98],"belly,":[99],"hip,":[100],"chest)":[102],"were":[103],"against":[111],"curvature":[113],"load":[115,156],"variations.":[116],"Statistical":[117],"analysis":[118],"shows":[119,167],"marked":[121],"decrease":[122],"standard":[125],"deviation":[126],"measured":[128],"temperatures":[129],"use":[132],"compared":[135],"conventional":[137],"manual":[138],"fixation.":[139],"At":[140],"repeated":[141],"measurements,":[142],"produces":[146],"less":[147],"uncertainty":[148],"estimate":[151],"true":[154],"lossy":[155],"temperature.":[157],"During":[158],"movement,":[160],"mounted":[163],"at":[164],"bone-filled":[165],"areas":[166],"greatest":[168],"potential":[169],"performance.":[172]},"counts_by_year":[{"year":2024,"cited_by_count":3},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":3},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":4},{"year":2018,"cited_by_count":4},{"year":2017,"cited_by_count":2},{"year":2015,"cited_by_count":1},{"year":2012,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2016-06-24T00:00:00"}
