{"id":"https://openalex.org/W2115372265","doi":"https://doi.org/10.1109/tbme.2010.2064774","title":"A Realistic Model for the Analysis of Heart Magnetic Stimulation","display_name":"A Realistic Model for the Analysis of Heart Magnetic Stimulation","publication_year":2010,"publication_date":"2010-08-10","ids":{"openalex":"https://openalex.org/W2115372265","doi":"https://doi.org/10.1109/tbme.2010.2064774","mag":"2115372265","pmid":"https://pubmed.ncbi.nlm.nih.gov/20699204"},"language":"en","primary_location":{"id":"doi:10.1109/tbme.2010.2064774","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbme.2010.2064774","pdf_url":null,"source":{"id":"https://openalex.org/S5240358","display_name":"IEEE Transactions on Biomedical Engineering","issn_l":"0018-9294","issn":["0018-9294","1558-2531"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Engineering","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5028897952","display_name":"Anna Pia Pastore","orcid":null},"institutions":[{"id":"https://openalex.org/I122534668","display_name":"Marche Polytechnic University","ror":"https://ror.org/00x69rs40","country_code":"IT","type":"education","lineage":["https://openalex.org/I122534668"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Anna Pia Pastore","raw_affiliation_strings":["Dipartimento di Ingegneria Biomedica, Elettronicae Telecomunicazioni, Universita Politecnica delle Marche, 60131 Ancona, Italy. a.p.pastore@univpm.it","Dipt. di Ing. Biomedica , Elettron. e Telecomun., Univ. Politec. delle Marche, Ancona, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dipartimento di Ingegneria Biomedica, Elettronicae Telecomunicazioni, Universita Politecnica delle Marche, 60131 Ancona, Italy. a.p.pastore@univpm.it","institution_ids":["https://openalex.org/I122534668"]},{"raw_affiliation_string":"Dipt. di Ing. Biomedica , Elettron. e Telecomun., Univ. Politec. delle Marche, Ancona, Italy","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5040379029","display_name":"Alfredo De Leo","orcid":"https://orcid.org/0000-0002-4235-921X"},"institutions":[{"id":"https://openalex.org/I122534668","display_name":"Marche Polytechnic University","ror":"https://ror.org/00x69rs40","country_code":"IT","type":"education","lineage":["https://openalex.org/I122534668"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Alfredo De Leo","raw_affiliation_strings":["Dipartimento di Ingegneria Biomedica, Universit\u00e1 Politecnica delle Marche, Ancona, Italy","Dipt. di Ing. Biomedica , Elettron. e Telecomun., Univ. Politec. delle Marche, Ancona, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dipartimento di Ingegneria Biomedica, Universit\u00e1 Politecnica delle Marche, Ancona, Italy","institution_ids":["https://openalex.org/I122534668"]},{"raw_affiliation_string":"Dipt. di Ing. Biomedica , Elettron. e Telecomun., Univ. Politec. delle Marche, Ancona, Italy","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5066434888","display_name":"R. De Leo","orcid":"https://orcid.org/0000-0003-3714-6022"},"institutions":[{"id":"https://openalex.org/I122534668","display_name":"Marche Polytechnic University","ror":"https://ror.org/00x69rs40","country_code":"IT","type":"education","lineage":["https://openalex.org/I122534668"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Roberto De Leo","raw_affiliation_strings":["Dipartimento di Ingegneria Biomedica, Universit\u00e1 Politecnica delle Marche, Ancona, Italy","Dipt. di Ing. Biomedica , Elettron. e Telecomun., Univ. Politec. delle Marche, Ancona, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dipartimento di Ingegneria Biomedica, Universit\u00e1 Politecnica delle Marche, Ancona, Italy","institution_ids":["https://openalex.org/I122534668"]},{"raw_affiliation_string":"Dipt. di Ing. Biomedica , Elettron. e Telecomun., Univ. Politec. delle Marche, Ancona, Italy","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5109294893","display_name":"Giuseppe Della Chiara","orcid":null},"institutions":[{"id":"https://openalex.org/I122534668","display_name":"Marche Polytechnic University","ror":"https://ror.org/00x69rs40","country_code":"IT","type":"education","lineage":["https://openalex.org/I122534668"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Giuseppe della Chiara","raw_affiliation_strings":["Dipartimento di Ingegneria Biomedica, Universit\u00e1 Politecnica delle Marche, Ancona, Italy","Dipt. di Ing. Biomedica , Elettron. e Telecomun., Univ. Politec. delle Marche, Ancona, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dipartimento di Ingegneria Biomedica, Universit\u00e1 Politecnica delle Marche, Ancona, Italy","institution_ids":["https://openalex.org/I122534668"]},{"raw_affiliation_string":"Dipt. di Ing. Biomedica , Elettron. e Telecomun., Univ. Politec. delle Marche, Ancona, Italy","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5091873214","display_name":"Valter Mariani Primiani","orcid":"https://orcid.org/0000-0001-5783-2041"},"institutions":[{"id":"https://openalex.org/I122534668","display_name":"Marche Polytechnic University","ror":"https://ror.org/00x69rs40","country_code":"IT","type":"education","lineage":["https://openalex.org/I122534668"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Valter Mariani Primiani","raw_affiliation_strings":["Dipartimento di Ingegneria Biomedica, Universit\u00e1 Politecnica delle Marche, Ancona, Italy","Dipt. di Ing. Biomedica , Elettron. e Telecomun., Univ. Politec. delle Marche, Ancona, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dipartimento di Ingegneria Biomedica, Universit\u00e1 Politecnica delle Marche, Ancona, Italy","institution_ids":["https://openalex.org/I122534668"]},{"raw_affiliation_string":"Dipt. di Ing. Biomedica , Elettron. e Telecomun., Univ. Politec. delle Marche, Ancona, Italy","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5000313938","display_name":"Franco Moglie","orcid":"https://orcid.org/0000-0003-4421-4396"},"institutions":[{"id":"https://openalex.org/I122534668","display_name":"Marche Polytechnic University","ror":"https://ror.org/00x69rs40","country_code":"IT","type":"education","lineage":["https://openalex.org/I122534668"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Franco Moglie","raw_affiliation_strings":["Dipartimento di Ingegneria Biomedica, Universit\u00e1 Politecnica delle Marche, Ancona, Italy","Dipt. di Ing. Biomedica , Elettron. e Telecomun., Univ. Politec. delle Marche, Ancona, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dipartimento di Ingegneria Biomedica, Universit\u00e1 Politecnica delle Marche, Ancona, Italy","institution_ids":["https://openalex.org/I122534668"]},{"raw_affiliation_string":"Dipt. di Ing. Biomedica , Elettron. e Telecomun., Univ. Politec. delle Marche, Ancona, Italy","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5028774958","display_name":"G. Cerri","orcid":"https://orcid.org/0000-0003-3243-8069"},"institutions":[{"id":"https://openalex.org/I122534668","display_name":"Marche Polytechnic University","ror":"https://ror.org/00x69rs40","country_code":"IT","type":"education","lineage":["https://openalex.org/I122534668"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Graziano Cerri","raw_affiliation_strings":["Dipartimento di Ingegneria Biomedica, Universit\u00e1 Politecnica delle Marche, Ancona, Italy","Dipt. di Ing. Biomedica , Elettron. e Telecomun., Univ. Politec. delle Marche, Ancona, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dipartimento di Ingegneria Biomedica, Universit\u00e1 Politecnica delle Marche, Ancona, Italy","institution_ids":["https://openalex.org/I122534668"]},{"raw_affiliation_string":"Dipt. di Ing. Biomedica , Elettron. e Telecomun., Univ. Politec. delle Marche, Ancona, Italy","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":7,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.1637,"has_fulltext":false,"cited_by_count":6,"citation_normalized_percentile":{"value":0.58751888,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":96},"biblio":{"volume":"58","issue":"2","first_page":"291","last_page":"300"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10429","display_name":"EEG and Brain-Computer Interfaces","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/2805","display_name":"Cognitive Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},"topics":[{"id":"https://openalex.org/T10429","display_name":"EEG and Brain-Computer Interfaces","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/2805","display_name":"Cognitive Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},{"id":"https://openalex.org/T10784","display_name":"Muscle activation and electromyography studies","score":0.9983999729156494,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11601","display_name":"Neuroscience and Neural Engineering","score":0.9973999857902527,"subfield":{"id":"https://openalex.org/subfields/2804","display_name":"Cellular and Molecular Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/biomagnetism","display_name":"Biomagnetism","score":0.7636185884475708},{"id":"https://openalex.org/keywords/waveform","display_name":"Waveform","score":0.7422260046005249},{"id":"https://openalex.org/keywords/magnetic-field","display_name":"Magnetic field","score":0.6546513438224792},{"id":"https://openalex.org/keywords/stimulation","display_name":"Stimulation","score":0.6106799840927124},{"id":"https://openalex.org/keywords/excitation","display_name":"Excitation","score":0.5778883099555969},{"id":"https://openalex.org/keywords/current-density","display_name":"Current density","score":0.5394426584243774},{"id":"https://openalex.org/keywords/electromagnetic-induction","display_name":"Electromagnetic induction","score":0.5135181546211243},{"id":"https://openalex.org/keywords/pulse","display_name":"Pulse (music)","score":0.5124476552009583},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.47339117527008057},{"id":"https://openalex.org/keywords/constraint","display_name":"Constraint (computer-aided design)","score":0.43542179465293884},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.43389198184013367},{"id":"https://openalex.org/keywords/nuclear-magnetic-resonance","display_name":"Nuclear magnetic resonance","score":0.4307442605495453},{"id":"https://openalex.org/keywords/human-heart","display_name":"Human heart","score":0.41415935754776},{"id":"https://openalex.org/keywords/computational-physics","display_name":"Computational physics","score":0.38174793124198914},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.26926159858703613},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2294107973575592},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.22241485118865967},{"id":"https://openalex.org/keywords/electromagnetic-coil","display_name":"Electromagnetic coil","score":0.20147162675857544},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.154514342546463},{"id":"https://openalex.org/keywords/neuroscience","display_name":"Neuroscience","score":0.13574934005737305},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.12192612886428833},{"id":"https://openalex.org/keywords/cardiology","display_name":"Cardiology","score":0.08199289441108704}],"concepts":[{"id":"https://openalex.org/C78902741","wikidata":"https://www.wikidata.org/wiki/Q4915071","display_name":"Biomagnetism","level":3,"score":0.7636185884475708},{"id":"https://openalex.org/C197424946","wikidata":"https://www.wikidata.org/wiki/Q1165717","display_name":"Waveform","level":3,"score":0.7422260046005249},{"id":"https://openalex.org/C115260700","wikidata":"https://www.wikidata.org/wiki/Q11408","display_name":"Magnetic field","level":2,"score":0.6546513438224792},{"id":"https://openalex.org/C24998067","wikidata":"https://www.wikidata.org/wiki/Q4114622","display_name":"Stimulation","level":2,"score":0.6106799840927124},{"id":"https://openalex.org/C83581075","wikidata":"https://www.wikidata.org/wiki/Q1361503","display_name":"Excitation","level":2,"score":0.5778883099555969},{"id":"https://openalex.org/C207740977","wikidata":"https://www.wikidata.org/wiki/Q234072","display_name":"Current density","level":2,"score":0.5394426584243774},{"id":"https://openalex.org/C102130693","wikidata":"https://www.wikidata.org/wiki/Q988780","display_name":"Electromagnetic induction","level":3,"score":0.5135181546211243},{"id":"https://openalex.org/C2780167933","wikidata":"https://www.wikidata.org/wiki/Q1550652","display_name":"Pulse (music)","level":3,"score":0.5124476552009583},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.47339117527008057},{"id":"https://openalex.org/C2776036281","wikidata":"https://www.wikidata.org/wiki/Q48769818","display_name":"Constraint (computer-aided design)","level":2,"score":0.43542179465293884},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.43389198184013367},{"id":"https://openalex.org/C46141821","wikidata":"https://www.wikidata.org/wiki/Q209402","display_name":"Nuclear magnetic resonance","level":1,"score":0.4307442605495453},{"id":"https://openalex.org/C2983437453","wikidata":"https://www.wikidata.org/wiki/Q1072","display_name":"Human heart","level":2,"score":0.41415935754776},{"id":"https://openalex.org/C30475298","wikidata":"https://www.wikidata.org/wiki/Q909554","display_name":"Computational physics","level":1,"score":0.38174793124198914},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.26926159858703613},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2294107973575592},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.22241485118865967},{"id":"https://openalex.org/C30403606","wikidata":"https://www.wikidata.org/wiki/Q2981904","display_name":"Electromagnetic coil","level":2,"score":0.20147162675857544},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.154514342546463},{"id":"https://openalex.org/C169760540","wikidata":"https://www.wikidata.org/wiki/Q207011","display_name":"Neuroscience","level":1,"score":0.13574934005737305},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.12192612886428833},{"id":"https://openalex.org/C164705383","wikidata":"https://www.wikidata.org/wiki/Q10379","display_name":"Cardiology","level":1,"score":0.08199289441108704},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D004554","descriptor_name":"Electric Countershock","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D004554","descriptor_name":"Electric Countershock","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D004554","descriptor_name":"Electric Countershock","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D006321","descriptor_name":"Heart","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006321","descriptor_name":"Heart","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006321","descriptor_name":"Heart","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006329","descriptor_name":"Heart Conduction System","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006329","descriptor_name":"Heart Conduction System","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006329","descriptor_name":"Heart Conduction System","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008955","descriptor_name":"Models, Cardiovascular","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D008955","descriptor_name":"Models, Cardiovascular","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D008955","descriptor_name":"Models, Cardiovascular","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D013909","descriptor_name":"Thorax","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D013909","descriptor_name":"Thorax","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D013909","descriptor_name":"Thorax","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D053443","descriptor_name":"Visible Human Projects","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D053443","descriptor_name":"Visible Human Projects","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D053443","descriptor_name":"Visible Human Projects","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":3,"locations":[{"id":"doi:10.1109/tbme.2010.2064774","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbme.2010.2064774","pdf_url":null,"source":{"id":"https://openalex.org/S5240358","display_name":"IEEE Transactions on Biomedical Engineering","issn_l":"0018-9294","issn":["0018-9294","1558-2531"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Engineering","raw_type":"journal-article"},{"id":"pmid:20699204","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/20699204","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE transactions on bio-medical engineering","raw_type":null},{"id":"pmh:oai:iris.univpm.it:11566/54452","is_oa":false,"landing_page_url":"http://hdl.handle.net/11566/54452","pdf_url":null,"source":{"id":"https://openalex.org/S4306402571","display_name":"Universit\u00e0 Politecnica delle Marche (Universit\u00e0 Politecnica delle Marche)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I122534668","host_organization_name":"Marche Polytechnic University","host_organization_lineage":["https://openalex.org/I122534668"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":19,"referenced_works":["https://openalex.org/W264431213","https://openalex.org/W1987158034","https://openalex.org/W1996757831","https://openalex.org/W2013586224","https://openalex.org/W2024371105","https://openalex.org/W2030348272","https://openalex.org/W2036008587","https://openalex.org/W2058871194","https://openalex.org/W2059906541","https://openalex.org/W2063955457","https://openalex.org/W2075018075","https://openalex.org/W2075069116","https://openalex.org/W2149509437","https://openalex.org/W2161848814","https://openalex.org/W2167534444","https://openalex.org/W2170430111","https://openalex.org/W2567089383","https://openalex.org/W4285719527","https://openalex.org/W6731476249"],"related_works":["https://openalex.org/W1974895211","https://openalex.org/W2176409448","https://openalex.org/W2129907517","https://openalex.org/W2029594206","https://openalex.org/W2734847834","https://openalex.org/W2121387357","https://openalex.org/W2286977336","https://openalex.org/W2293537622","https://openalex.org/W2507978275","https://openalex.org/W2970185210"],"abstract_inverted_index":{"The":[0,36,115],"aim":[1],"of":[2,8,22,50,111,118,138],"the":[3,6,15,20,47,51,62,67,76,81,99,109,119,125,136,139,144],"paper":[4],"is":[5,88,104,122],"development":[7],"an":[9,30,71],"accurate":[10],"numerical":[11],"model":[12,37],"to":[13,45,80],"compute":[14],"current":[16,63,126],"density":[17,64],"flowing":[18],"through":[19],"heart":[21,52],"a":[23,112,133],"virtual":[24],"human":[25],"body,":[26],"and":[27,42,106,130,143],"induced":[28,65],"by":[29,60,70,124],"external":[31,72],"electric":[32,84],"or":[33],"magnetic":[34,53,73,140],"excitation.":[35],"has":[38,56],"been":[39,57],"experimentally":[40],"validated":[41],"then":[43],"applied":[44],"investigate":[46],"main":[48],"characteristics":[49],"stimulation.":[54],"This":[55],"carried":[58],"out":[59],"comparing":[61],"in":[66,95],"cardiac":[68],"region":[69],"pulse":[74,145],"with":[75,98],"corresponding":[77],"quantity":[78],"due":[79],"more":[82],"traditional":[83],"source.":[85],"Magnetic":[86],"stimulation":[87,110],"studied":[89],"because":[90],"it":[91],"offers":[92],"some":[93],"advantages:":[94],"fact,":[96],"compared":[97],"electrical":[100],"stimulation,":[101],"this":[102],"technique":[103],"contactless":[105],"might":[107],"allow":[108],"dressed":[113],"patient.":[114],"design":[116],"constraint":[117],"whole":[120],"system":[121],"represented":[123],"density,":[127],"whose":[128],"waveform":[129],"intensity":[131],"are":[132],"compromise":[134],"between":[135],"strength":[137],"induction":[141],"field":[142],"rise":[146],"time.":[147]},"counts_by_year":[{"year":2020,"cited_by_count":2},{"year":2016,"cited_by_count":1},{"year":2014,"cited_by_count":2}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
