{"id":"https://openalex.org/W2171448566","doi":"https://doi.org/10.1109/tbme.2009.2016215","title":"Calibration Capacity of the Conductance-to-Volume Conversion Equations for the Mouse Conductance Catheter Measurement System","display_name":"Calibration Capacity of the Conductance-to-Volume Conversion Equations for the Mouse Conductance Catheter Measurement System","publication_year":2009,"publication_date":"2009-03-09","ids":{"openalex":"https://openalex.org/W2171448566","doi":"https://doi.org/10.1109/tbme.2009.2016215","mag":"2171448566","pmid":"https://pubmed.ncbi.nlm.nih.gov/19272973"},"language":"en","primary_location":{"id":"doi:10.1109/tbme.2009.2016215","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbme.2009.2016215","pdf_url":null,"source":{"id":"https://openalex.org/S5240358","display_name":"IEEE Transactions on Biomedical Engineering","issn_l":"0018-9294","issn":["0018-9294","1558-2531"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Engineering","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5070035068","display_name":"Chia\u2010Ling Wei","orcid":"https://orcid.org/0000-0002-0056-4821"},"institutions":[{"id":"https://openalex.org/I91807558","display_name":"National Cheng Kung University","ror":"https://ror.org/01b8kcc49","country_code":"TW","type":"education","lineage":["https://openalex.org/I91807558"]}],"countries":["TW"],"is_corresponding":true,"raw_author_name":"Chia-Ling Wei","raw_affiliation_strings":["Department of Electrical Engineering, National Cheng Kung University, Tainan 70101, Taiwan. clwei@mail.ncku.edu.tw","National Cheng Kung University, Tainan, TW"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, National Cheng Kung University, Tainan 70101, Taiwan. clwei@mail.ncku.edu.tw","institution_ids":["https://openalex.org/I91807558"]},{"raw_affiliation_string":"National Cheng Kung University, Tainan, TW","institution_ids":["https://openalex.org/I91807558"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5043751363","display_name":"Ming-Hsien Shih","orcid":null},"institutions":[{"id":"https://openalex.org/I91807558","display_name":"National Cheng Kung University","ror":"https://ror.org/01b8kcc49","country_code":"TW","type":"education","lineage":["https://openalex.org/I91807558"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Ming-Hsien Shih","raw_affiliation_strings":["Department of Electrical Engineering, National Cheng Kung University, Tainan, Taiwan, Taiwan"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, National Cheng Kung University, Tainan, Taiwan, Taiwan","institution_ids":["https://openalex.org/I91807558"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5070035068"],"corresponding_institution_ids":["https://openalex.org/I91807558"],"apc_list":null,"apc_paid":null,"fwci":1.1963,"has_fulltext":false,"cited_by_count":15,"citation_normalized_percentile":{"value":0.81946435,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":97},"biblio":{"volume":"56","issue":"6","first_page":"1627","last_page":"1634"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11778","display_name":"Electrical and Bioimpedance Tomography","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11778","display_name":"Electrical and Bioimpedance Tomography","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11700","display_name":"Hemodynamic Monitoring and Therapy","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9965000152587891,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/conductance","display_name":"Conductance","score":0.7964761853218079},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.7095848321914673},{"id":"https://openalex.org/keywords/volume","display_name":"Volume (thermodynamics)","score":0.6852868795394897},{"id":"https://openalex.org/keywords/position","display_name":"Position (finance)","score":0.597475528717041},{"id":"https://openalex.org/keywords/nonlinear-system","display_name":"Nonlinear system","score":0.5684403777122498},{"id":"https://openalex.org/keywords/ventricular-volume","display_name":"Ventricular volume","score":0.4340575933456421},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.43256285786628723},{"id":"https://openalex.org/keywords/measure","display_name":"Measure (data warehouse)","score":0.4194630980491638},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.4111875295639038},{"id":"https://openalex.org/keywords/mathematical-analysis","display_name":"Mathematical analysis","score":0.4047110080718994},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.39938583970069885},{"id":"https://openalex.org/keywords/mechanics","display_name":"Mechanics","score":0.3797370493412018},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.35224249958992004},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.3234003484249115},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.20641592144966125},{"id":"https://openalex.org/keywords/thermodynamics","display_name":"Thermodynamics","score":0.1912713348865509},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.1860021948814392},{"id":"https://openalex.org/keywords/statistics","display_name":"Statistics","score":0.16672268509864807},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.16097021102905273},{"id":"https://openalex.org/keywords/cardiology","display_name":"Cardiology","score":0.13845381140708923}],"concepts":[{"id":"https://openalex.org/C121932024","wikidata":"https://www.wikidata.org/wiki/Q5159376","display_name":"Conductance","level":2,"score":0.7964761853218079},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.7095848321914673},{"id":"https://openalex.org/C20556612","wikidata":"https://www.wikidata.org/wiki/Q4469374","display_name":"Volume (thermodynamics)","level":2,"score":0.6852868795394897},{"id":"https://openalex.org/C198082294","wikidata":"https://www.wikidata.org/wiki/Q3399648","display_name":"Position (finance)","level":2,"score":0.597475528717041},{"id":"https://openalex.org/C158622935","wikidata":"https://www.wikidata.org/wiki/Q660848","display_name":"Nonlinear system","level":2,"score":0.5684403777122498},{"id":"https://openalex.org/C3020038371","wikidata":"https://www.wikidata.org/wiki/Q2002035","display_name":"Ventricular volume","level":4,"score":0.4340575933456421},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.43256285786628723},{"id":"https://openalex.org/C2780009758","wikidata":"https://www.wikidata.org/wiki/Q6804172","display_name":"Measure (data warehouse)","level":2,"score":0.4194630980491638},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.4111875295639038},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.4047110080718994},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.39938583970069885},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.3797370493412018},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.35224249958992004},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.3234003484249115},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.20641592144966125},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.1912713348865509},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.1860021948814392},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.16672268509864807},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.16097021102905273},{"id":"https://openalex.org/C164705383","wikidata":"https://www.wikidata.org/wiki/Q10379","display_name":"Cardiology","level":1,"score":0.13845381140708923},{"id":"https://openalex.org/C2778198053","wikidata":"https://www.wikidata.org/wiki/Q181754","display_name":"Heart failure","level":2,"score":0.0},{"id":"https://openalex.org/C77088390","wikidata":"https://www.wikidata.org/wiki/Q8513","display_name":"Database","level":1,"score":0.0},{"id":"https://openalex.org/C162324750","wikidata":"https://www.wikidata.org/wiki/Q8134","display_name":"Economics","level":0,"score":0.0},{"id":"https://openalex.org/C78085059","wikidata":"https://www.wikidata.org/wiki/Q641303","display_name":"Ejection fraction","level":3,"score":0.0},{"id":"https://openalex.org/C114614502","wikidata":"https://www.wikidata.org/wiki/Q76592","display_name":"Combinatorics","level":1,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C10138342","wikidata":"https://www.wikidata.org/wiki/Q43015","display_name":"Finance","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D000818","descriptor_name":"Animals","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000818","descriptor_name":"Animals","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000818","descriptor_name":"Animals","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D002138","descriptor_name":"Calibration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D002138","descriptor_name":"Calibration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D002138","descriptor_name":"Calibration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D003198","descriptor_name":"Computer Simulation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D003198","descriptor_name":"Computer Simulation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D003198","descriptor_name":"Computer Simulation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004553","descriptor_name":"Electric Conductivity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004553","descriptor_name":"Electric Conductivity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004553","descriptor_name":"Electric Conductivity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004567","descriptor_name":"Electrodes, Implanted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004567","descriptor_name":"Electrodes, Implanted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004567","descriptor_name":"Electrodes, Implanted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006321","descriptor_name":"Heart","qualifier_ui":"Q000033","qualifier_name":"anatomy & histology","is_major_topic":false},{"descriptor_ui":"D006321","descriptor_name":"Heart","qualifier_ui":"Q000033","qualifier_name":"anatomy & histology","is_major_topic":false},{"descriptor_ui":"D006321","descriptor_name":"Heart","qualifier_ui":"Q000033","qualifier_name":"anatomy & histology","is_major_topic":false},{"descriptor_ui":"D006328","descriptor_name":"Cardiac Catheterization","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D006328","descriptor_name":"Cardiac Catheterization","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D006328","descriptor_name":"Cardiac Catheterization","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D008279","descriptor_name":"Magnetic Resonance Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008279","descriptor_name":"Magnetic Resonance Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008279","descriptor_name":"Magnetic Resonance Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008955","descriptor_name":"Models, Cardiovascular","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D008955","descriptor_name":"Models, Cardiovascular","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D008955","descriptor_name":"Models, Cardiovascular","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D017711","descriptor_name":"Nonlinear Dynamics","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017711","descriptor_name":"Nonlinear Dynamics","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017711","descriptor_name":"Nonlinear Dynamics","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D020342","descriptor_name":"Finite Element Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D020342","descriptor_name":"Finite Element Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D020342","descriptor_name":"Finite Element Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D025802","descriptor_name":"Electric Capacitance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D025802","descriptor_name":"Electric Capacitance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D025802","descriptor_name":"Electric Capacitance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D051379","descriptor_name":"Mice","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D051379","descriptor_name":"Mice","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D051379","descriptor_name":"Mice","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":2,"locations":[{"id":"doi:10.1109/tbme.2009.2016215","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbme.2009.2016215","pdf_url":null,"source":{"id":"https://openalex.org/S5240358","display_name":"IEEE Transactions on Biomedical Engineering","issn_l":"0018-9294","issn":["0018-9294","1558-2531"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Engineering","raw_type":"journal-article"},{"id":"pmid:19272973","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/19272973","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE transactions on bio-medical engineering","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.49000000953674316,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":23,"referenced_works":["https://openalex.org/W1509267336","https://openalex.org/W1963771304","https://openalex.org/W1966265144","https://openalex.org/W1984225869","https://openalex.org/W2022981781","https://openalex.org/W2033279521","https://openalex.org/W2058871194","https://openalex.org/W2076063695","https://openalex.org/W2091678174","https://openalex.org/W2097364562","https://openalex.org/W2102585418","https://openalex.org/W2107263417","https://openalex.org/W2124615399","https://openalex.org/W2124799177","https://openalex.org/W2127923590","https://openalex.org/W2129526506","https://openalex.org/W2155027729","https://openalex.org/W2159539825","https://openalex.org/W2217188422","https://openalex.org/W2537846602","https://openalex.org/W2971244461","https://openalex.org/W6630426404","https://openalex.org/W6728745580"],"related_works":["https://openalex.org/W2035271760","https://openalex.org/W2144661048","https://openalex.org/W166353894","https://openalex.org/W4255837520","https://openalex.org/W2030970284","https://openalex.org/W2055385333","https://openalex.org/W2061523378","https://openalex.org/W2124181728","https://openalex.org/W2387011115","https://openalex.org/W2067124413"],"abstract_inverted_index":{"The":[0,64,87],"conductance":[1,22,31],"catheter":[2,32,61,69],"system":[3,33],"is":[4,15,53,116],"used":[5],"to":[6,23,105],"measure":[7],"instantaneous":[8],"ventricular":[9,13,85],"conductance,":[10],"and":[11,40,82,89,102],"real-time":[12],"volume":[14,50,99],"then":[16],"determined":[17],"by":[18,55],"converting":[19],"the":[20,30,46,60,67,73,93,106,109,112],"measured":[21],"volume.":[24],"Two":[25],"conductance-to-volume":[26],"conversion":[27,95,114],"equations":[28,96],"for":[29,97],"have":[34],"been":[35],"proposed:":[36],"Baan's":[37],"linear":[38],"equation":[39,115],"Wei's":[41],"nonlinear":[42,113],"equation.":[43],"In":[44],"fact,":[45],"accuracy":[47,88],"of":[48,66,92,111],"this":[49],"estimation":[51],"method":[52],"limited":[54],"several":[56],"factors,":[57],"such":[58],"as":[59],"position":[62,70],"deviation.":[63],"effects":[65],"mouse":[68,83],"deviations":[71],"on":[72],"volume-conductance":[74],"relationships":[75],"are":[76,100],"investigated":[77],"with":[78],"cylindrical":[79],"finite-element":[80],"models":[81],"left":[84],"models.":[86],"calibration":[90],"capacity":[91],"two":[94],"estimating":[98],"evaluated":[101],"compared.":[103],"According":[104],"comparison":[107],"results,":[108],"performance":[110],"better.":[117]},"counts_by_year":[{"year":2024,"cited_by_count":2},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":2},{"year":2014,"cited_by_count":3},{"year":2013,"cited_by_count":3},{"year":2012,"cited_by_count":2}],"updated_date":"2026-01-13T01:12:25.745995","created_date":"2025-10-10T00:00:00"}
