{"id":"https://openalex.org/W4417169507","doi":"https://doi.org/10.1109/tbcas.2025.3641977","title":"Mm-Wave CMOS Biosensor With Integrated Dielectrophoresis for Single-Cell Detection and Characterization","display_name":"Mm-Wave CMOS Biosensor With Integrated Dielectrophoresis for Single-Cell Detection and Characterization","publication_year":2025,"publication_date":"2025-12-09","ids":{"openalex":"https://openalex.org/W4417169507","doi":"https://doi.org/10.1109/tbcas.2025.3641977","pmid":"https://pubmed.ncbi.nlm.nih.gov/41364563"},"language":"en","primary_location":{"id":"doi:10.1109/tbcas.2025.3641977","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbcas.2025.3641977","pdf_url":null,"source":{"id":"https://openalex.org/S80299757","display_name":"IEEE Transactions on Biomedical Circuits and Systems","issn_l":"1932-4545","issn":["1932-4545","1940-9990"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Circuits and Systems","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5082445255","display_name":"Ali Ameri","orcid":"https://orcid.org/0000-0002-4609-5661"},"institutions":[{"id":"https://openalex.org/I95457486","display_name":"University of California, Berkeley","ror":"https://ror.org/01an7q238","country_code":"US","type":"education","lineage":["https://openalex.org/I95457486"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Ali Ameri","raw_affiliation_strings":["Department of Electrical Engineering and Computer Sciences (EECS), University of California Berkeley, Berkeley, CA, USA"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering and Computer Sciences (EECS), University of California Berkeley, Berkeley, CA, USA","institution_ids":["https://openalex.org/I95457486"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5039764227","display_name":"Ali M. Niknejad","orcid":"https://orcid.org/0000-0002-9246-9791"},"institutions":[{"id":"https://openalex.org/I95457486","display_name":"University of California, Berkeley","ror":"https://ror.org/01an7q238","country_code":"US","type":"education","lineage":["https://openalex.org/I95457486"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Ali M. Niknejad","raw_affiliation_strings":["Department of Electrical Engineering and Computer Sciences (EECS), University of California Berkeley, Berkeley, CA, USA"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering and Computer Sciences (EECS), University of California Berkeley, Berkeley, CA, USA","institution_ids":["https://openalex.org/I95457486"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5082445255"],"corresponding_institution_ids":["https://openalex.org/I95457486"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.38430383,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"20","issue":"2","first_page":"328","last_page":"340"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11255","display_name":"Microfluidic and Bio-sensing Technologies","score":0.9904000163078308,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11255","display_name":"Microfluidic and Bio-sensing Technologies","score":0.9904000163078308,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11455","display_name":"Microbial Inactivation Methods","score":0.0017999999690800905,"subfield":{"id":"https://openalex.org/subfields/1305","display_name":"Biotechnology"},"field":{"id":"https://openalex.org/fields/13","display_name":"Biochemistry, Genetics and Molecular Biology"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},{"id":"https://openalex.org/T12789","display_name":"Planarian Biology and Electrostimulation","score":0.0007999999797903001,"subfield":{"id":"https://openalex.org/subfields/1312","display_name":"Molecular Biology"},"field":{"id":"https://openalex.org/fields/13","display_name":"Biochemistry, Genetics and Molecular Biology"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/dielectrophoresis","display_name":"Dielectrophoresis","score":0.942799985408783},{"id":"https://openalex.org/keywords/microfluidics","display_name":"Microfluidics","score":0.7407000064849854},{"id":"https://openalex.org/keywords/cmos","display_name":"CMOS","score":0.732200026512146},{"id":"https://openalex.org/keywords/biosensor","display_name":"Biosensor","score":0.572700023651123},{"id":"https://openalex.org/keywords/nanosensor","display_name":"Nanosensor","score":0.5519000291824341},{"id":"https://openalex.org/keywords/characterization","display_name":"Characterization (materials science)","score":0.550599992275238},{"id":"https://openalex.org/keywords/lithography","display_name":"Lithography","score":0.515500009059906},{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.46970000863075256}],"concepts":[{"id":"https://openalex.org/C106825181","wikidata":"https://www.wikidata.org/wiki/Q902890","display_name":"Dielectrophoresis","level":3,"score":0.942799985408783},{"id":"https://openalex.org/C8673954","wikidata":"https://www.wikidata.org/wiki/Q138845","display_name":"Microfluidics","level":2,"score":0.7407000064849854},{"id":"https://openalex.org/C46362747","wikidata":"https://www.wikidata.org/wiki/Q173431","display_name":"CMOS","level":2,"score":0.732200026512146},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.6074000000953674},{"id":"https://openalex.org/C160756335","wikidata":"https://www.wikidata.org/wiki/Q669391","display_name":"Biosensor","level":2,"score":0.572700023651123},{"id":"https://openalex.org/C171250308","wikidata":"https://www.wikidata.org/wiki/Q11468","display_name":"Nanotechnology","level":1,"score":0.5694000124931335},{"id":"https://openalex.org/C41858301","wikidata":"https://www.wikidata.org/wiki/Q2327870","display_name":"Nanosensor","level":2,"score":0.5519000291824341},{"id":"https://openalex.org/C2780841128","wikidata":"https://www.wikidata.org/wiki/Q5073781","display_name":"Characterization (materials science)","level":2,"score":0.550599992275238},{"id":"https://openalex.org/C204223013","wikidata":"https://www.wikidata.org/wiki/Q133036","display_name":"Lithography","level":2,"score":0.515500009059906},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.46970000863075256},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3894999921321869},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.3537999987602234},{"id":"https://openalex.org/C192209626","wikidata":"https://www.wikidata.org/wiki/Q190909","display_name":"Focus (optics)","level":2,"score":0.33820000290870667},{"id":"https://openalex.org/C527607","wikidata":"https://www.wikidata.org/wiki/Q175538","display_name":"Microfabrication","level":4,"score":0.336899995803833},{"id":"https://openalex.org/C105487726","wikidata":"https://www.wikidata.org/wiki/Q622938","display_name":"Photolithography","level":2,"score":0.3066999912261963},{"id":"https://openalex.org/C154020017","wikidata":"https://www.wikidata.org/wiki/Q520171","display_name":"Repeatability","level":2,"score":0.29600000381469727},{"id":"https://openalex.org/C198531522","wikidata":"https://www.wikidata.org/wiki/Q485146","display_name":"Sample (material)","level":2,"score":0.28540000319480896},{"id":"https://openalex.org/C111670793","wikidata":"https://www.wikidata.org/wiki/Q16979465","display_name":"Microelectrode","level":3,"score":0.2782000005245209},{"id":"https://openalex.org/C2780077345","wikidata":"https://www.wikidata.org/wiki/Q16891888","display_name":"Spice","level":2,"score":0.2678999900817871},{"id":"https://openalex.org/C138942068","wikidata":"https://www.wikidata.org/wiki/Q633261","display_name":"Lab-on-a-chip","level":3,"score":0.26100000739097595},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.250900000333786}],"mesh":[{"descriptor_ui":"D004586","descriptor_name":"Electrophoresis","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D004586","descriptor_name":"Electrophoresis","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D004586","descriptor_name":"Electrophoresis","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D004586","descriptor_name":"Electrophoresis","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D004586","descriptor_name":"Electrophoresis","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D004586","descriptor_name":"Electrophoresis","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006367","descriptor_name":"HeLa Cells","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006367","descriptor_name":"HeLa Cells","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006367","descriptor_name":"HeLa Cells","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012666","descriptor_name":"Semiconductors","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012666","descriptor_name":"Semiconductors","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012666","descriptor_name":"Semiconductors","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015374","descriptor_name":"Biosensing Techniques","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D015374","descriptor_name":"Biosensing Techniques","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D015374","descriptor_name":"Biosensing Techniques","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D015374","descriptor_name":"Biosensing Techniques","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D015374","descriptor_name":"Biosensing Techniques","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D015374","descriptor_name":"Biosensing Techniques","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D059010","descriptor_name":"Single-Cell Analysis","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D059010","descriptor_name":"Single-Cell Analysis","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D059010","descriptor_name":"Single-Cell Analysis","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D059010","descriptor_name":"Single-Cell Analysis","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D059010","descriptor_name":"Single-Cell Analysis","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D059010","descriptor_name":"Single-Cell Analysis","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true}],"locations_count":2,"locations":[{"id":"doi:10.1109/tbcas.2025.3641977","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbcas.2025.3641977","pdf_url":null,"source":{"id":"https://openalex.org/S80299757","display_name":"IEEE Transactions on Biomedical Circuits and Systems","issn_l":"1932-4545","issn":["1932-4545","1940-9990"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Circuits and Systems","raw_type":"journal-article"},{"id":"pmid:41364563","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/41364563","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE transactions on biomedical circuits and systems","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"an":[3],"injection-locked":[4],"voltage-controlled":[5],"oscillator-based":[6],"sensing":[7],"platform":[8,73],"capable":[9],"of":[10,43,95,114],"detecting":[11],"and":[12,31,41,70,92,110],"characterizing":[13],"single":[14,97],"mammalian":[15],"cells":[16],"at":[17],"114GHz.":[18],"The":[19,46,72],"sensor":[20],"is":[21,55,74],"equipped":[22],"with":[23,35,57],"on-chip":[24],"Dielectrophoresis":[25],"(DEP)":[26],"force":[27],"generators":[28],"that":[29,64],"focus":[30],"align":[32],"the":[33,36,39,44,90],"sample":[34,67],"sensor,":[37],"maximizing":[38],"sensitivity":[40],"repeatability":[42],"measurements.":[45],"chip,":[47],"fabricated":[48],"in":[49,76],"a":[50,60,96,104],"bulk":[51],"28nm":[52],"CMOS":[53],"technology,":[54],"packaged":[56],"microfluidics":[58],"using":[59],"single-mask":[61],"lithography":[62],"technique":[63],"enables":[65],"continuous":[66],"delivery,":[68],"measurement,":[69],"removal.":[71],"demonstrated":[75],"differentiating":[77],"various":[78],"materials,":[79],"three":[80],"cell":[81,98],"lines":[82],"(HeLa":[83],"GFP,":[84],"HCT-116,":[85],"SK-MEL-28),":[86],"and,":[87],"most":[88],"importantly,":[89],"growth":[91],"mitotic":[93],"states":[94],"line.":[99],"These":[100],"unique":[101],"capabilities":[102],"establish":[103],"foundation":[105],"for":[106],"streamlining":[107],"cell-based":[108],"assays":[109],"enabling":[111],"real-time":[112],"monitoring":[113],"drug-cell":[115],"interactions.":[116]},"counts_by_year":[],"updated_date":"2026-03-31T07:56:22.981413","created_date":"2025-12-09T00:00:00"}
