{"id":"https://openalex.org/W4416429389","doi":"https://doi.org/10.1109/tbcas.2025.3634251","title":"A Neurostimulator for Deep Brain Stimulation With Wide Load Current and Impedance Adaptation Capability","display_name":"A Neurostimulator for Deep Brain Stimulation With Wide Load Current and Impedance Adaptation Capability","publication_year":2025,"publication_date":"2025-11-20","ids":{"openalex":"https://openalex.org/W4416429389","doi":"https://doi.org/10.1109/tbcas.2025.3634251","pmid":"https://pubmed.ncbi.nlm.nih.gov/41264433"},"language":"en","primary_location":{"id":"doi:10.1109/tbcas.2025.3634251","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbcas.2025.3634251","pdf_url":null,"source":{"id":"https://openalex.org/S80299757","display_name":"IEEE Transactions on Biomedical Circuits and Systems","issn_l":"1932-4545","issn":["1932-4545","1940-9990"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Circuits and Systems","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5023287650","display_name":"Cheng\u2010Hsiu Tsai","orcid":"https://orcid.org/0000-0003-3617-366X"},"institutions":[{"id":"https://openalex.org/I25846049","display_name":"National Tsing Hua University","ror":"https://ror.org/00zdnkx70","country_code":"TW","type":"education","lineage":["https://openalex.org/I25846049"]}],"countries":["TW"],"is_corresponding":true,"raw_author_name":"Cheng-Jung Tsai","raw_affiliation_strings":["Neuromorphic and Biomedical Engineering Laboratory, Department of Electrical Engineering, National Tsing Hua University (NTHU), Hsinchu, Taiwan","Department of Electrical Engineering, National Tsing Hua University (NTHU), Hsinchu, Taiwan"],"affiliations":[{"raw_affiliation_string":"Neuromorphic and Biomedical Engineering Laboratory, Department of Electrical Engineering, National Tsing Hua University (NTHU), Hsinchu, Taiwan","institution_ids":["https://openalex.org/I25846049"]},{"raw_affiliation_string":"Department of Electrical Engineering, National Tsing Hua University (NTHU), Hsinchu, Taiwan","institution_ids":["https://openalex.org/I25846049"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5044259295","display_name":"Kea\u2010Tiong Tang","orcid":"https://orcid.org/0000-0002-9689-1236"},"institutions":[{"id":"https://openalex.org/I25846049","display_name":"National Tsing Hua University","ror":"https://ror.org/00zdnkx70","country_code":"TW","type":"education","lineage":["https://openalex.org/I25846049"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Kea-Tiong Tang","raw_affiliation_strings":["Neuromorphic and Biomedical Engineering Laboratory, Department of Electrical Engineering, National Tsing Hua University (NTHU), Hsinchu, Taiwan","Department of Electrical Engineering, National Tsing Hua University (NTHU), Hsinchu, Taiwan"],"affiliations":[{"raw_affiliation_string":"Neuromorphic and Biomedical Engineering Laboratory, Department of Electrical Engineering, National Tsing Hua University (NTHU), Hsinchu, Taiwan","institution_ids":["https://openalex.org/I25846049"]},{"raw_affiliation_string":"Department of Electrical Engineering, National Tsing Hua University (NTHU), Hsinchu, Taiwan","institution_ids":["https://openalex.org/I25846049"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5023287650"],"corresponding_institution_ids":["https://openalex.org/I25846049"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.38258036,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"20","issue":"2","first_page":"242","last_page":"255"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11601","display_name":"Neuroscience and Neural Engineering","score":0.44620001316070557,"subfield":{"id":"https://openalex.org/subfields/2804","display_name":"Cellular and Molecular Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},"topics":[{"id":"https://openalex.org/T11601","display_name":"Neuroscience and Neural Engineering","score":0.44620001316070557,"subfield":{"id":"https://openalex.org/subfields/2804","display_name":"Cellular and Molecular Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},{"id":"https://openalex.org/T10919","display_name":"Neurological disorders and treatments","score":0.36160001158714294,"subfield":{"id":"https://openalex.org/subfields/2728","display_name":"Neurology"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10429","display_name":"EEG and Brain-Computer Interfaces","score":0.0681999996304512,"subfield":{"id":"https://openalex.org/subfields/2805","display_name":"Cognitive Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electrical-impedance","display_name":"Electrical impedance","score":0.6452999711036682},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.603600025177002},{"id":"https://openalex.org/keywords/capacitor","display_name":"Capacitor","score":0.5213000178337097},{"id":"https://openalex.org/keywords/output-impedance","display_name":"Output impedance","score":0.47760000824928284},{"id":"https://openalex.org/keywords/high-impedance","display_name":"High impedance","score":0.4595000147819519},{"id":"https://openalex.org/keywords/electronic-circuit","display_name":"Electronic circuit","score":0.4399999976158142},{"id":"https://openalex.org/keywords/chip","display_name":"Chip","score":0.40700000524520874},{"id":"https://openalex.org/keywords/power-consumption","display_name":"Power consumption","score":0.37880000472068787},{"id":"https://openalex.org/keywords/system-on-a-chip","display_name":"System on a chip","score":0.3752000033855438},{"id":"https://openalex.org/keywords/slew-rate","display_name":"Slew rate","score":0.3580000102519989}],"concepts":[{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.6452999711036682},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.603600025177002},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.5213000178337097},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.48399999737739563},{"id":"https://openalex.org/C58112919","wikidata":"https://www.wikidata.org/wiki/Q631203","display_name":"Output impedance","level":3,"score":0.47760000824928284},{"id":"https://openalex.org/C174268685","wikidata":"https://www.wikidata.org/wiki/Q769127","display_name":"High impedance","level":3,"score":0.4595000147819519},{"id":"https://openalex.org/C134146338","wikidata":"https://www.wikidata.org/wiki/Q1815901","display_name":"Electronic circuit","level":2,"score":0.4399999976158142},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.43529999256134033},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4131999909877777},{"id":"https://openalex.org/C165005293","wikidata":"https://www.wikidata.org/wiki/Q1074500","display_name":"Chip","level":2,"score":0.40700000524520874},{"id":"https://openalex.org/C2984118289","wikidata":"https://www.wikidata.org/wiki/Q29954","display_name":"Power consumption","level":3,"score":0.37880000472068787},{"id":"https://openalex.org/C118021083","wikidata":"https://www.wikidata.org/wiki/Q610398","display_name":"System on a chip","level":2,"score":0.3752000033855438},{"id":"https://openalex.org/C82517063","wikidata":"https://www.wikidata.org/wiki/Q1591315","display_name":"Slew rate","level":3,"score":0.3580000102519989},{"id":"https://openalex.org/C115051666","wikidata":"https://www.wikidata.org/wiki/Q6522493","display_name":"Ranging","level":2,"score":0.3472999930381775},{"id":"https://openalex.org/C612350","wikidata":"https://www.wikidata.org/wiki/Q1761108","display_name":"Impedance matching","level":3,"score":0.3407000005245209},{"id":"https://openalex.org/C180205008","wikidata":"https://www.wikidata.org/wiki/Q159190","display_name":"Amplitude","level":2,"score":0.3400000035762787},{"id":"https://openalex.org/C46362747","wikidata":"https://www.wikidata.org/wiki/Q173431","display_name":"CMOS","level":2,"score":0.33739998936653137},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3328000009059906},{"id":"https://openalex.org/C39394816","wikidata":"https://www.wikidata.org/wiki/Q939318","display_name":"RC circuit","level":4,"score":0.3276999890804291},{"id":"https://openalex.org/C88182573","wikidata":"https://www.wikidata.org/wiki/Q1139740","display_name":"High voltage","level":3,"score":0.3149999976158142},{"id":"https://openalex.org/C530198007","wikidata":"https://www.wikidata.org/wiki/Q80831","display_name":"Integrated circuit","level":2,"score":0.30059999227523804},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.2919999957084656},{"id":"https://openalex.org/C99844830","wikidata":"https://www.wikidata.org/wiki/Q102441924","display_name":"Scaling","level":2,"score":0.28700000047683716},{"id":"https://openalex.org/C26262908","wikidata":"https://www.wikidata.org/wiki/Q1307489","display_name":"Input impedance","level":3,"score":0.2838999927043915},{"id":"https://openalex.org/C2779918689","wikidata":"https://www.wikidata.org/wiki/Q3771842","display_name":"Stimulus (psychology)","level":2,"score":0.2703999876976013},{"id":"https://openalex.org/C74524168","wikidata":"https://www.wikidata.org/wiki/Q1074539","display_name":"Integrated circuit design","level":2,"score":0.266400009393692},{"id":"https://openalex.org/C117551214","wikidata":"https://www.wikidata.org/wiki/Q6692774","display_name":"Low-power electronics","level":4,"score":0.2653999924659729},{"id":"https://openalex.org/C2776886225","wikidata":"https://www.wikidata.org/wiki/Q1931676","display_name":"500 kHz","level":2,"score":0.26489999890327454},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.26420000195503235},{"id":"https://openalex.org/C137488568","wikidata":"https://www.wikidata.org/wiki/Q5321","display_name":"Resistor","level":3,"score":0.258899986743927},{"id":"https://openalex.org/C2985799443","wikidata":"https://www.wikidata.org/wiki/Q4955838","display_name":"Brain stimulation","level":3,"score":0.25839999318122864},{"id":"https://openalex.org/C128624480","wikidata":"https://www.wikidata.org/wiki/Q1504817","display_name":"Low voltage","level":3,"score":0.2554999887943268},{"id":"https://openalex.org/C177606310","wikidata":"https://www.wikidata.org/wiki/Q5674297","display_name":"Adaptability","level":2,"score":0.25459998846054077},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.2500999867916107}],"mesh":[{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017097","descriptor_name":"Electric Impedance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017097","descriptor_name":"Electric Impedance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017097","descriptor_name":"Electric Impedance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D046690","descriptor_name":"Deep Brain Stimulation","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D046690","descriptor_name":"Deep Brain Stimulation","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D046690","descriptor_name":"Deep Brain Stimulation","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D058542","descriptor_name":"Implantable Neurostimulators","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D058542","descriptor_name":"Implantable Neurostimulators","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D058542","descriptor_name":"Implantable Neurostimulators","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true}],"locations_count":2,"locations":[{"id":"doi:10.1109/tbcas.2025.3634251","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbcas.2025.3634251","pdf_url":null,"source":{"id":"https://openalex.org/S80299757","display_name":"IEEE Transactions on Biomedical Circuits and Systems","issn_l":"1932-4545","issn":["1932-4545","1940-9990"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Circuits and Systems","raw_type":"journal-article"},{"id":"pmid:41264433","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/41264433","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE transactions on biomedical circuits and systems","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"In":[0,128],"this":[1,79,87],"work,":[2],"a":[3,44,58,90,107,143,180],"biphasic":[4],"and":[5,26,66,75,123,178],"bipolar":[6],"current-controlled":[7],"stimulator":[8,16],"with":[9,167],"high":[10,21,83,140,160],"loading":[11,50,84],"adaptability":[12],"is":[13,151,171],"proposed.":[14],"The":[15,163],"consisted":[17],"of":[18,46,69,138,184,196],"an":[19,27],"on-chip":[20],"voltage":[22,141],"generator,":[23,142],"output":[24,62,110,169],"driver":[25],"8-bit":[28],"current":[29],"DAC":[30],"(Digital-to-Analog":[31],"Converter),":[32],"can":[33],"constantly":[34],"provide":[35],"the":[36,49,64,70,101,133,139,194,197],"required":[37],"stimulus":[38,165,198],"currents":[39],"ranging":[40],"from":[41],"0.1mA":[42],"to":[43,99,114,130,153,192],"maximum":[45],"20mA,":[47],"as":[48,118],"impedance":[51,85],"varied":[52],"within":[53],"0.5k\u03a9":[54],"-":[55],"5k\u03a9.":[56],"With":[57],"nearly":[59],"12":[60],"V":[61],"voltage,":[63],"overstress":[65],"reliability":[67],"issues":[68],"circuits":[71],"are":[72,190],"thoroughly":[73],"considered":[74],"carefully":[76],"addressed":[77],"in":[78,173],"work.":[80],"To":[81],"achieve":[82],"adaptability,":[86],"paper":[88],"proposes":[89],"novel":[91],"PAM":[92],"(Pulse":[93,120,125],"Amplitude":[94],"Modulation)":[95,122],"loop":[96],"control":[97],"architecture":[98],"drive":[100],"charge":[102],"pump":[103],"(CP),":[104],"which":[105],"provides":[106],"significantly":[108],"higher":[109],"dynamic":[111],"range":[112],"compared":[113],"conventional":[115],"methods":[116],"such":[117],"PFM":[119],"Frequency":[121],"PSM":[124],"Skip":[126],"Modulation).":[127],"addition,":[129],"further":[131],"improve":[132],"Power":[134],"Conversion":[135],"Efficiency":[136],"(PCE)":[137],"new":[144],"technique,":[145],"PAM-based":[146],"Dual-Domain":[147],"Voltage":[148],"Scaling":[149],"(PAM-DDVS),":[150],"proposed":[152],"minimize":[154],"unnecessary":[155],"energy":[156],"consumption":[157],"while":[158],"achieving":[159],"adaptive":[161],"range.":[162],"fully-integrated":[164],"chip":[166],"2":[168],"channels":[170],"fabricated":[172],"TSMC":[174],"0.18\u00b5m":[175],"1.8V/3.3V":[176],"process,":[177],"occupies":[179],"core":[181],"die":[182],"area":[183],"approximately":[185],"1.6":[186],"mm<sup>2</sup>.":[187],"Imitation":[188],"tests":[189],"conducted":[191],"validate":[193],"functionality":[195],"chip.":[199]},"counts_by_year":[],"updated_date":"2026-03-31T07:56:22.981413","created_date":"2025-11-20T00:00:00"}
