{"id":"https://openalex.org/W4410738213","doi":"https://doi.org/10.1109/tbcas.2025.3573614","title":"A 96 dB Input Dynamic Range Galvanic Skin Response Readout IC With 3.5 pA<sub>rms</sub> Input-Referred Noise for Mental Stress Monitoring","display_name":"A 96 dB Input Dynamic Range Galvanic Skin Response Readout IC With 3.5 pA<sub>rms</sub> Input-Referred Noise for Mental Stress Monitoring","publication_year":2025,"publication_date":"2025-05-26","ids":{"openalex":"https://openalex.org/W4410738213","doi":"https://doi.org/10.1109/tbcas.2025.3573614","pmid":"https://pubmed.ncbi.nlm.nih.gov/40418611"},"language":"en","primary_location":{"id":"doi:10.1109/tbcas.2025.3573614","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbcas.2025.3573614","pdf_url":null,"source":{"id":"https://openalex.org/S80299757","display_name":"IEEE Transactions on Biomedical Circuits and Systems","issn_l":"1932-4545","issn":["1932-4545","1940-9990"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Circuits and Systems","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5103434646","display_name":"Yi-Jie Lin","orcid":null},"institutions":[{"id":"https://openalex.org/I148366613","display_name":"National Yang Ming Chiao Tung University","ror":"https://ror.org/00se2k293","country_code":"TW","type":"education","lineage":["https://openalex.org/I148366613"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Yi-Jie Lin","raw_affiliation_strings":["Institute of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Hsinchu, Taiwan","Institute of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Taiwan"],"raw_orcid":"https://orcid.org/0009-0008-1593-3037","affiliations":[{"raw_affiliation_string":"Institute of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Hsinchu, Taiwan","institution_ids":["https://openalex.org/I148366613"]},{"raw_affiliation_string":"Institute of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Taiwan","institution_ids":["https://openalex.org/I148366613"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5010423216","display_name":"Lin Chou","orcid":null},"institutions":[{"id":"https://openalex.org/I148366613","display_name":"National Yang Ming Chiao Tung University","ror":"https://ror.org/00se2k293","country_code":"TW","type":"education","lineage":["https://openalex.org/I148366613"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Lin Chou","raw_affiliation_strings":["Institute of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Hsinchu, Taiwan","Institute of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Taiwan"],"raw_orcid":"https://orcid.org/0000-0002-9533-7487","affiliations":[{"raw_affiliation_string":"Institute of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Hsinchu, Taiwan","institution_ids":["https://openalex.org/I148366613"]},{"raw_affiliation_string":"Institute of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Taiwan","institution_ids":["https://openalex.org/I148366613"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5075491678","display_name":"Kun\u2010Ju Tsai","orcid":null},"institutions":[{"id":"https://openalex.org/I4210148468","display_name":"Industrial Technology Research Institute","ror":"https://ror.org/05szzwt63","country_code":"TW","type":"nonprofit","lineage":["https://openalex.org/I4210148468"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Kun-Ju Tsai","raw_affiliation_strings":["Industrial Technology Research Institute, Hsinchu, Taiwan","Industrial Technology Research Institute, Taiwan"],"raw_orcid":"https://orcid.org/0000-0002-4726-1270","affiliations":[{"raw_affiliation_string":"Industrial Technology Research Institute, Hsinchu, Taiwan","institution_ids":["https://openalex.org/I4210148468"]},{"raw_affiliation_string":"Industrial Technology Research Institute, Taiwan","institution_ids":["https://openalex.org/I4210148468"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5066171565","display_name":"Yu\u2010Te Liao","orcid":"https://orcid.org/0000-0002-6868-6729"},"institutions":[{"id":"https://openalex.org/I148366613","display_name":"National Yang Ming Chiao Tung University","ror":"https://ror.org/00se2k293","country_code":"TW","type":"education","lineage":["https://openalex.org/I148366613"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Yu-Te Liao","raw_affiliation_strings":["Institute of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Hsinchu, Taiwan","Institute of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Taiwan"],"raw_orcid":"https://orcid.org/0000-0002-6868-6729","affiliations":[{"raw_affiliation_string":"Institute of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Hsinchu, Taiwan","institution_ids":["https://openalex.org/I148366613"]},{"raw_affiliation_string":"Institute of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Taiwan","institution_ids":["https://openalex.org/I148366613"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.6613,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.63538234,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":97},"biblio":{"volume":"19","issue":"5","first_page":"897","last_page":"907"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10323","display_name":"Analog and Mixed-Signal Circuit Design","score":0.9865000247955322,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10323","display_name":"Analog and Mixed-Signal Circuit Design","score":0.9865000247955322,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11601","display_name":"Neuroscience and Neural Engineering","score":0.9592999815940857,"subfield":{"id":"https://openalex.org/subfields/2804","display_name":"Cellular and Molecular Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},{"id":"https://openalex.org/T11992","display_name":"CCD and CMOS Imaging Sensors","score":0.9036999940872192,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/dynamic-range","display_name":"Dynamic range","score":0.7122323513031006},{"id":"https://openalex.org/keywords/noise","display_name":"Noise (video)","score":0.6068839430809021},{"id":"https://openalex.org/keywords/stress","display_name":"Stress (linguistics)","score":0.5370001196861267},{"id":"https://openalex.org/keywords/skin-conductance","display_name":"Skin conductance","score":0.5364276766777039},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.44446706771850586},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.4373876452445984},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.37244415283203125},{"id":"https://openalex.org/keywords/optoelectronics","display_name":"Optoelectronics","score":0.3525978922843933},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.31163734197616577},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.29659318923950195},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.13114550709724426}],"concepts":[{"id":"https://openalex.org/C87133666","wikidata":"https://www.wikidata.org/wiki/Q1161699","display_name":"Dynamic range","level":2,"score":0.7122323513031006},{"id":"https://openalex.org/C99498987","wikidata":"https://www.wikidata.org/wiki/Q2210247","display_name":"Noise (video)","level":3,"score":0.6068839430809021},{"id":"https://openalex.org/C21036866","wikidata":"https://www.wikidata.org/wiki/Q181767","display_name":"Stress (linguistics)","level":2,"score":0.5370001196861267},{"id":"https://openalex.org/C111902132","wikidata":"https://www.wikidata.org/wiki/Q1326834","display_name":"Skin conductance","level":2,"score":0.5364276766777039},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.44446706771850586},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4373876452445984},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.37244415283203125},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.3525978922843933},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.31163734197616577},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.29659318923950195},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.13114550709724426},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C138885662","wikidata":"https://www.wikidata.org/wiki/Q5891","display_name":"Philosophy","level":0,"score":0.0},{"id":"https://openalex.org/C115961682","wikidata":"https://www.wikidata.org/wiki/Q860623","display_name":"Image (mathematics)","level":2,"score":0.0},{"id":"https://openalex.org/C41895202","wikidata":"https://www.wikidata.org/wiki/Q8162","display_name":"Linguistics","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D000076251","descriptor_name":"Wearable Electronic Devices","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000076251","descriptor_name":"Wearable Electronic Devices","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000076251","descriptor_name":"Wearable Electronic Devices","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000076251","descriptor_name":"Wearable Electronic Devices","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000076251","descriptor_name":"Wearable Electronic Devices","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D005712","descriptor_name":"Galvanic Skin Response","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":true},{"descriptor_ui":"D005712","descriptor_name":"Galvanic Skin Response","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":true},{"descriptor_ui":"D005712","descriptor_name":"Galvanic Skin Response","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":true},{"descriptor_ui":"D005712","descriptor_name":"Galvanic Skin Response","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":true},{"descriptor_ui":"D005712","descriptor_name":"Galvanic Skin Response","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":true},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013315","descriptor_name":"Stress, Psychological","qualifier_ui":"Q000175","qualifier_name":"diagnosis","is_major_topic":true},{"descriptor_ui":"D013315","descriptor_name":"Stress, Psychological","qualifier_ui":"Q000175","qualifier_name":"diagnosis","is_major_topic":true},{"descriptor_ui":"D013315","descriptor_name":"Stress, Psychological","qualifier_ui":"Q000175","qualifier_name":"diagnosis","is_major_topic":true},{"descriptor_ui":"D013315","descriptor_name":"Stress, Psychological","qualifier_ui":"Q000175","qualifier_name":"diagnosis","is_major_topic":true},{"descriptor_ui":"D013315","descriptor_name":"Stress, Psychological","qualifier_ui":"Q000175","qualifier_name":"diagnosis","is_major_topic":true},{"descriptor_ui":"D013315","descriptor_name":"Stress, Psychological","qualifier_ui":"Q000503","qualifier_name":"physiopathology","is_major_topic":true},{"descriptor_ui":"D013315","descriptor_name":"Stress, Psychological","qualifier_ui":"Q000503","qualifier_name":"physiopathology","is_major_topic":true},{"descriptor_ui":"D013315","descriptor_name":"Stress, Psychological","qualifier_ui":"Q000503","qualifier_name":"physiopathology","is_major_topic":true},{"descriptor_ui":"D013315","descriptor_name":"Stress, Psychological","qualifier_ui":"Q000503","qualifier_name":"physiopathology","is_major_topic":true},{"descriptor_ui":"D013315","descriptor_name":"Stress, Psychological","qualifier_ui":"Q000503","qualifier_name":"physiopathology","is_major_topic":true}],"locations_count":2,"locations":[{"id":"doi:10.1109/tbcas.2025.3573614","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbcas.2025.3573614","pdf_url":null,"source":{"id":"https://openalex.org/S80299757","display_name":"IEEE Transactions on Biomedical Circuits and Systems","issn_l":"1932-4545","issn":["1932-4545","1940-9990"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Circuits and Systems","raw_type":"journal-article"},{"id":"pmid:40418611","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/40418611","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE transactions on biomedical circuits and systems","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W2115969310","https://openalex.org/W2524332325","https://openalex.org/W2744701634","https://openalex.org/W2794007858","https://openalex.org/W2884519067","https://openalex.org/W2927166626","https://openalex.org/W2958197594","https://openalex.org/W3126326356","https://openalex.org/W3135832803","https://openalex.org/W4360606534"],"related_works":["https://openalex.org/W4327518326","https://openalex.org/W2141696378","https://openalex.org/W3167332943","https://openalex.org/W2013850956","https://openalex.org/W2075530399","https://openalex.org/W1995211429","https://openalex.org/W105289849","https://openalex.org/W2081953805","https://openalex.org/W2283463320","https://openalex.org/W2978406538"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"a":[3,40,52,71],"low-noise,":[4],"low-power":[5],"galvanic":[6],"skin":[7,16,21],"response":[8,23],"(GSR)":[9],"sensing":[10],"circuit":[11,30],"capable":[12],"of":[13,48,80],"simultaneously":[14],"measuring":[15],"conductance":[17,22],"level":[18],"(SCL)":[19],"and":[20,39,96,102],"(SCR)":[24],"for":[25,98],"psychological":[26],"stress":[27,100],"monitoring.":[28],"The":[29,68],"incorporates":[31],"second-order":[32],"sub-ten-hertz":[33],"filters":[34],"that":[35],"suppresses":[36],"out-of-band":[37],"interference":[38],"programmable":[41],"gain":[42],"amplifier":[43],"(PGA)":[44],"to":[45],"accommodate":[46],"signals":[47],"varying":[49],"magnitudes.":[50],"Additionally,":[51],"dynamic":[53,74],"range":[54,62,75],"adjustment":[55],"mechanism":[56],"optimizes":[57],"the":[58],"primary":[59],"amplifier\u2019s":[60],"operating":[61],"based":[63],"on":[64],"real-time":[65,103],"SCL":[66],"readings.":[67],"design":[69],"achieves":[70],"96.4":[72],"dB":[73],"with":[76],"an":[77],"input-referred":[78],"noise":[79],"only":[81],"3.47":[82],"pArms":[83],"within":[84],"0.5\u20135":[85],"Hz":[86],"under":[87],"optimal":[88],"conditions.":[89],"These":[90],"advancements":[91],"significantly":[92],"enhance":[93],"measurement":[94],"accuracy":[95],"robustness":[97],"wearable":[99],"monitoring":[101],"biofeedback":[104],"applications.":[105]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":1}],"updated_date":"2026-07-29T09:40:50.615796","created_date":"2025-05-27T00:00:00"}